HARVEST TEC 201SS H2O Moisture Sensing Kit Owner’s Manual

August 30, 2024
HARVEST TEC

HARVEST TEC 201SS H2O Moisture Sensing Kit

HARVEST-TEC-201SS-H2O-Moisture-Sensing-Kit-PRODUCT

Product Information

Specifications:

  • Model: 201SS & 200DM
  • Product Type: Small Square Baler Precision Moisture Sensing Kit
  • Moisture Reading Range: 5-33%

Product Usage Instructions

Requirements:

The Harvest Tec H2O Moisture Sensing Kit Model 201SB system requires the following:

  • Compatible operating system for Apple and Android devices
  • Original phone/tablet power cable for proper communication

Tools Needed:

  • SAE wrench set
  • Standard screwdriver
  • Side cutter
  • Hammer
  • Measuring tape
  • SAE socket set
  • Drill bit set
  • Center punch

Installation of Star Wheels:

Two-Tie Balers:

The star wheels should be mounted on the bottom side of the bale chute as close to the front as possible. Ensure they are at least 3/8 inches away from any metal and a safe distance from the twine.

Follow these steps for mounting the star wheels:

  1. Drill two holes per block, keeping the wheel square to the bale chamber.
  2. Use supplied bolts to attach the star wheels with washers and nuts.
  3. Connect the star wheel sensor wire through the grommet and secure it tightly.

Three-Tie Balers:

For three-tie balers, mount the star wheels on the top of the bale chamber near the knotters following the same installation steps as for two-tie balers.

Frequently Asked Questions

  • Q: What is the moisture reading range of the Harvest Tec H2O Moisture Sensing Kit?
    • A: The system is designed to read moisture levels between 5-33%.
  • Q: What tools are required for installing the star wheels on the baler?
    • A: You will need an SAE wrench set, standard screwdriver, side cutter, hammer, measuring tape, SAE socket set, drill bit set, and a center punch.

Introduction

Congratulations and thank you for purchasing a Harvest Tec H2O Moisture Sensing Kit Model 201SB system. Please read this manual carefully to ensure correct steps are taken to attach the system to the baler. This system is designed to read moisture at levels of 5-33%.

Requirements

The app will support operation of the current operating system and one previous version for both Apple and Android devices.
**It is recommended for proper communication that the original phone/tablet power cable is used. Many lower cost power cables do not meet requirements to properly charge and communicate to the Harvest Tec H2O module

Tools Needed

  • SAE wrench set
  • Hammer
  • Drill bit set
  • Standard screw driver
  • Measuring tape
  • Center punch
  • Side cutter
  • SAE socket set

Installation of Star Wheels

Two-Tie Balers Only

The pair of star wheels will need to mount on the bottom side as close to the front of the bale chute as possible and at least 3/8” (10mm) away from any metal. They will need to maintain a safe distance away from the twine.
Depending on the baler model the star wheels can mount in front of the needle arm Option A (below) if there is space available. When there is not enough room for the star wheel use Option B
The star wheels will require two holes to be drilled per block, when drilling make sure to keep the wheel square to the bale chamber. Any angle will cause stress on the wheel and will eventually cause the wheel to work itself out of the block. Some balers may require a notch cut on the bottom of the bale chamber to mount the star wheels as close to the front of the chamber as possible. Use the supplied bolts and place the head inside of the bale chamber. Next attach 001-6707ES to the outside of the chamber. Then attach the star wheels to the bolts followed by the flat washer, lock washer, and nut. First, remove the cover from the star wheel block and use a 1/4” (7mm) nut driver to remove the nut from the electronic swivel. Next, run the star wheel sensor wire through the black grommet and place the eye terminal on the star wheel sensor. Tighten the eye loop with the nut on the sensor and put the star wheel cover back on the base. Next, tighten the grommet to form a tight seal around the wire. Secure the harness to the baler to avoid moving parts.

HARVEST-TEC-201SS-H2O-Moisture-Sensing-Kit-FIG \(1\)

Three-Tie Balers Only

When using a three-tie baler the star wheels will need to be mounted on the top of the bale chamber as close to the knotters as possible (shown below). Use the instructions above for proper star wheel installation

HARVEST-TEC-201SS-H2O-Moisture-Sensing-Kit-FIG \(2\)

Control Box Installation

Locate a safe location in the cab of the tractor to place the control box (006-2473RB) in a location to connect a USB cable ending in a USB-A plug to connect to display device. Connect the Power Harness (006-2470P) and the Baler Power Communication Harness (006-2470SS). The control box (006-2473SB) is equipped with a green light to indicated both power and connection.

Plug the tablet/phone cord into the communication port (closest to light) and indicated by:

  • Slow Blink – System has power but not connected to phone or tablet.
  • Solid Green – Device is connected.

**It is recommended for proper communication that the original phone/tablet power cable is used. Many lower cost power cables do not meet requirements to properly charge and communicate to the Harvest Tec H2O module.

End of Bale Sensor Installation – 200FCA (Optional)

The end of bale sensor is used to determine when the baler needle arm moves. With this information the system is able to show the average moisture of the previous bale. Part number for kit is 200FCA
Mount the 006-7400 sensor to the mounting bracket 001-4648RB as shown below. Mount the assembly on the right side of the baler chamber. The face of the sensor needs to be parallel to the arm attached to the needles. *Note: The bracket may need to be slightly bent for the proper positioning.
Mark and drill two 3/8” (10mm) holes. Install the sensor using two 5/16” x 1“ allen head bolts, locks, and nuts. The end of the sensor needs to be no greater than 1/4” (7mm) away from the needle arm. Tighten nuts on sensor after adjustment. The harness will need to be routed toward the harness at the tongue of the baler. Secure with cable ties and take care to avoid pinch points. The harness extension (006-7400EXT) may need to be used.HARVEST-TEC-
201SS-H2O-Moisture-Sensing-Kit-FIG \(5\)

Dye Marker Installation – 200DM (Optional)

Locate the dye marking kit tank and pump assembly (005-9015). Identify a suitable mounting location for the tank away from moving parts and hydraulic lines on the baler. Be sure to mount the tank within 10’ of the connection on the Baler Pwr/Comm Harness (006-2470SS), wiring details in the wiring diagram. Note: The mounting location will potentially be different for the tank on each baler model. Due to various baler designs and modifications, Harvest Tec does not offer a specific mounting location for each baler model. Once a mounting location has been identified, mount the tank vertically as shown (right) with the tank lid on the top using the included hardware. Next locate the dye marking spray assemblies shown (below).

Nozzle straps should be placed directly above star wheels so spray will be applied on the top of the bale in the twine grooves. *Small square and Large square balers must us the brass tip (004-TX-5) Mount the second tip assembly on the left side of the baler in a similar position to allow the tip to spray the bale.

HARVEST-TEC-201SS-H2O-Moisture-Sensing-Kit-FIG \(8\)

Routing the Hose

Using the supplied 1/4” hose (002-9006) connect to the pump and secure with the hose clamps (003-9002). Route the hose to each tip assembly by using the 1/4″ Barbed Tee (003-T1414) to go to each side of the baler. Be sure to avoid moving parts.

Wiring Diagram

  1. Connect the power harness (006-2470P) to the tractor convenience outlet keyed power switch using the red wire with fuse to the positive side and the black wire to the negative. a. Any modifications of the power harness will void the warranty. Contact Harvest Tec before modifications are made.
  2. The power harness (006-2470P) will mount on the tractor connected to the control box (006-2473SB) with the 12-pin male deutsch connection and the opposite end down to the draw bar.
  3. Connect the Baler Pwr/Comm Harness (006-2470SB) to the power harness (006-2470P).
  4. Route the Pwr/Comm Harness (006-2470SS) on the baler to each moisture sensor on both sides of bale chamber, sensors are pn 030-4642UX.
  5. Connect the USB charging/comm cord for the phone or tablet being used to that device and the 201 control box (006-2473SB).
  6. When using a Dye Marker, the End of Bale Sensor kit will need to be added to the system in order to see when needle arm cycles. Part number (200FCA). Connect the sensor to the End of Bale (EOB) connection on the Baler Pwr/Comm Harness (006-2470SS).
  7. When using the optional Dye Marker (200DM) connect 4 pin round end of the H2O harness (006-2470C) to the Dye Marker (DM) connection on the (006-2470SS) harness. Then connect the two straight spade connections with only the white wire to the push switch (006-2850). The remaining two connections with 90-degree female spades will connect to the pump.

System wiring diagramHARVEST-TEC-201SS-H2O-Moisture-Sensing-Kit-FIG
\(9\)

*If needed an optional 8’ Pwr/Comm harness extension is available (not included), part number 006-2470BL2.

Downloading H2O App

The H2O App is available on any Apple or Android device running with the current operating system software and one previous version. Download the app by searching for H2O Sensor. App icon shown right.

Screen Definitions

Main Screen

HARVEST-TEC-201SS-H2O-Moisture-Sensing-Kit-FIG \(10\)

Settings ScreenHARVEST-TEC-201SS-H2O-Moisture-Sensing-Kit-FIG
\(11\)

Operation

After installation of the H2O app, turn the system on by turning the key in the tractor on. When the connection is made the green light on the control box will illuminate

Reading Moisture

Moisture Range 5-33%HARVEST-TEC-201SS-H2O-Moisture-Sensing-Kit-FIG
\(13\)

Dye Marker System

  • When using the dye marker turn on the setting as shown and select the desired moisture to mark a bale. *Bales at or above this moisture level will be marked.
  • Dye Marker icon will now appear on the home screen. The last bale moisture will be highlighted in red and the bale will be marked at or above the set moisture.

Dye Marker Notes

  • When the Dye Marker is activated by the moisture setting it will spray 3 seconds once per End of Bale (EOB) cycle. After an EOB signal the dye marker is then reset to be able to spray again for 3 seconds once on the next bale.
  • A full tank of dye is estimated to mark 50-60 bales.

Dye Marker Override

If you would like to mark a bale for any reason, press the bale icon which will cause it to turn green. When the manual override is used the last bale moisture will not highlight in red. The manual spray function can be used on a bale as many times as preferred in 3 second intervals

H2O Firmware Update through App

When there is an update available for the H2O system the following information will appear, and the steps listed will need to be followed. Once an operator downloads the app update (internet connection required) the “update available” symbol will appear along with the version number of the available update once connected to the system. At this point the system can run without updating if the operator chooses. The icon will simply remain on the screen. Once the operator decides to perform the software update, they will press the version number or upload arrow to begin. Internet connection is not required to perform the update to the module once the app is downloaded

  • Once the update is initiated, the system will enter update mode The status light will turn red
  • A green loading symbol will begin to circulate on the screen A status bar with then appear to show the update progress This can take 3-5 minutes to load software
  • Once the status bar load completely, the system will boot back up The status light will again turn green The updated version number will be shown at the bottom of the screenHARVEST-TEC-201SS-H2O-Moisture-Sensing-Kit-FIG \(18\)

It is recommended for proper communication that the original phone/tablet power cable is used. Many lower cost power cables do not meet requirements to properly charge and communicate to the Harvest Tec H2O module.

H2O Tractor Module 006-2473SB

Pin 1     Red                  Module Power Pin 2                  Red/Black EOB +

Pin 3     Black                EOB –

Pin 4     Grey                 Left Moisture Sensor

Pin 5     Brown               Right Moisture Sensor

Pin 6     Purple               EOB Signal

Pin 7     Yellow              CAN +

Pin 8     Green               CAN –

Pin 9 Red/White   Dye Marker 12V + Pin 10 Black/White  Dye Marker 12V – Pin 11 Blue                   Dye Marker Prime

Pin 12 Black                 Ground

| ****


---|---
H2O Tractor Harness 006-2470P at Module Plug

Pin 1     Red                  Module Power Pin 2                  Red/Black EOB +

Pin 3     Black                EOB –

Pin 4  Grey                 Left Moisture Sensor

Pin 5  Brown               Right Moisture Sensor

Pin 6     Purple               EOB Signal

Pin 7  Yellow              Not Used

Pin 8  Green               Not Used

Pin 9 Red/White   Dye Marker 12V + Pin 10 Black/White  Dye Marker 12V – Pin 11 Blue                   Dye Marker Prime

Pin 12 Black                 Ground

| ****



Baler Communication Harness 006-2470SS at hitch

Pin 1     Red/Black            EOB + Pin 2            Black EOB –

Pin 3     Grey                 Left Moisture Sensor

Pin 4     Brown               Right Moisture Sensor

Pin 5     Purple               EOB Signal

Pin 6 Red/White  Dye Marker 12V + Pin 7 Black/White  Dye Marker 12V – Pin 8 Blue                  Dye Marker Prime

| ****





End of Bale Sensor (EOB) 006-2471B

Pin 1     Brown               EOB +

Pin 2     Blue                  EOB –

Pin 3     N/A                   Not Used

Pin 4     Black                EOB Signal

| ****



HARVEST-TEC-201SS-H2O-Moisture-Sensing-Kit-FIG \(22\)


Dye Marker H2O Harness 006-2470C

Pin 1     Red                  DS +

Pin 2     Black                DS –

Pin 3     White                DS Prime

Pin 4     N/A                   Not Used

| ****



Parts Breakdowns

Star Wheel assembly 030-4642UX

HARVEST-TEC-201SS-H2O-Moisture-Sensing-Kit-FIG \(24\)

Ref Description Part# Qty
1 Star Wheel with insert (includes 1, 8, & hardware) 006-4642US 1
  Hardware Kit (items 2,5,6,7) 006-4642UK
2 Dust Seal Gasket (some pre 2024 blocks use 2 seals) 006-4642UG 1
  Spacer (used in some pre 2024 blocks) 006-4642UBS 1
3 3/8” Wiring Grommet 008-0821A 1
  3/8” Wiring Grommet Nut 008-0821B 1
4 Block (available in 2024 style only) 006-4642UB 1
5 Thrust Washer 006-4642TA 2
6 Thrust Bearing 006-4642TB 1
7 3/4″ Short Nut 006-4642U 1
8 Swivel Insert 006-4642B 1
9 Rotary Swivel 006-4642A 1
10 Star Wheel Block Gasket- for 2024 block style 006-4642UG2 1
  Star Wheel Block Gasket- for pre 2024 blocks 006-4642UG
11 Block Cover- for 2024 block style 006-4642UC2 1
  Block Cover- for pre 2024 block style 006-4642UC
  Complete Star Wheel Assembly 030-4642UX 2
  Optional* Twine Guard Diverter-Left 001-4645
  Optional* Twine Guard Diverter-Right 001-4644

Control Box & HarnessesHARVEST-TEC-201SS-H2O-Moisture-Sensing-Kit-FIG
\(26\)

Fixed Chamber End of Bale Sensor KitHARVEST-TEC-201SS-H2O-Moisture-
Sensing-Kit-FIG \(28\)

H2O Dye MarkerHARVEST-TEC-201SS-H2O-Moisture-Sensing-Kit-FIG
\(29\)

Ref| Description| Part #| Qty| Ref| Description| Part #| Qty
---|---|---|---|---|---|---|---
1| H2O Harness (10’)| 006-2470C| 1| 8| 1/4″ Street Elbow| 003-SE14F| 2
2| Tank & Pump| 005-9015| 1| 9| Check Valve| 007-1207VB| 2
3| Nozzle Cap| 004-4723| 4| 10| 1/4″ Straight Fitting| 003-A1414VB| 2
4| Tip – Brass| 004-TX-5| 2| 11| Push Switch| 006-2850| 1
5| Tip Strainer (Green)| 004-1203-100| 2| 12| 1/4″ All Barb Tee| 003-T1414| 1
6| Nozzle Body| 004-4722| 2| 13| Mini Hose Clamp| 003-9002| 6
7| Nozzle Holder| 001-4215| 2| 14| 1/4″ Hose| 002-9006| 40
 |  |  |  | NP| Red Dye| 009-0800| 1
 |  |  |  | NP| End of Bale Sensor Kit| 200FCA| 1
 |  |  |  | Complete Assembly| 030-200DM|

Harvest Tec LLC. Warranty and Liability Agreement

Harvest Tec, LLC. will repair or replace components that are found to be defective within 12 months from the date of manufacture. Under no circumstances does this warranty cover any components which in the opinion of Harvest Tec, LLC. have been subjected to negligent use, misuse, alteration, accident, or if repairs have been made with parts other than those manufactured and obtainable from Harvest Tec, LLC. Our obligation under this warranty is limited to repairing or replacing free of charge to the original purchaser any part that in our judgment shows evidence of defective or improper workmanship, provided the part is returned to Harvest Tec, LLC. within 30 days of the failure. If it is determined that a non-Harvest Tec branded hay preservative has been used inside the Harvest Tec applicator system where the failure occurred, then Harvest Tec reserves the right to deny the warranty request at their discretion. Parts must be returned through the selling dealer and distributor, and transportation charges prepaid. This warranty shall not be interpreted to render Harvest Tec, LLC. liable for injury or damages of any kind, direct, consequential, or contingent, to persons or property. Furthermore, this warranty does not extend to loss of crop, losses caused by delays or any expense prospective profits or for any other reason. Harvest Tec, LLC. shall not be liable for any recovery greater in amount than the cost or repair of defects in workmanship. There are no warranties, either expressed or implied, of merchantability or fitness for particular purpose intended or fitness for any other reason. This warranty cannot guarantee that existing conditions beyond the control of Harvest Tec, LLC. will not affect our ability to obtain materials or manufacture necessary replacement parts. Harvest Tec, LLC. reserves the right to make design changes, improve design, or change specifications, at any time without any contingent obligation to purchasers of machines and parts previously sold. Revised 6/22

Contact

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

HARVEST TEC User Manuals

Related Manuals