VOLTECH SCP50 Solar Charge Controller Installation Guide
- August 30, 2024
- VOLTECH
Table of Contents
SCP50 Solar Charge Controller
“`html
Product Information
Specifications
-
Model: SCP-050
-
Controller Type: MPPT
-
Maximum Current: 50A
-
Features: Battery state of charge monitoring, Charging process
control -
Display: LCD screen
-
LED Indicators: Green (charging status), Red
(error/alarms) -
USB Output: 2 x 3.4A
-
Other Ports: Temperature Sensor, PV, Battery, Load, RJ45 (for
remote control)
Product Usage Instructions
Safety Precautions
Ensure the solar charge controller is not used in dusty or
flammable environments. Adequate ventilation is necessary.
Regularly monitor the charging process and follow battery
manufacturer’s instructions.
In case of acid splashes, rinse immediately with soap water or
plenty of water for skin and eyes respectively. Seek medical advice
if needed.
If the controller shows fault behavior or damage, disconnect it
from the panels and battery immediately.
Functionality
The controller monitors battery charge status, controls
charging, and ensures proper functioning of the solar system.
Operating Instructions
-
Use the up and down buttons to navigate through menus on the
LCD screen. -
Green LED indicates charging status (off/not charging,
flashing/charging, on/fully charged). -
Red LED indicates error or alarms (off/no error,
on/error). -
Utilize the USB output for external device charging.
-
Do not use the RJ45 port as it is reserved for remote
control.
Frequently Asked Questions (FAQ)
Q: What should I do if the controller emits smoke?
A: Immediately disconnect the controller from the solar panels
and battery and ensure safety measures are in place.
Q: How do I know if the battery is fully charged?
A: The green LED light on the controller will be on when the
battery is fully charged.
“`
50A MPPT Controller SCP-050
Installation and Operating Instructions Solar System Controller SCP050
ABOUT THIS MANUAL
These operating instructions come with the product and should be kept with it
as a reference to all user’s of the product.
Read these operating instructions carefully before use, Keep them over the
entire life of the product, And pass then on to any future owner or user of
this product.
This manual describes the installation, function, operation and maintenance of
the solar system controller SCP050.
These operating instructions are intended for end customers. A technical
expert must be consulted in cases of uncertainty.
SAFETY
1. The solar controller may only be used in PV systems for charging STD, AGM,
LiFePO4 battery. Note; User’s should always refer to battery
manufacturer/supplier’s recommended values for battery charging settings and
float voltage setting. 2. No energy source other than a solar panel (PV) may
be connected to the solar charge controller. 3. Do not connect any defective
or damaged measuring equipment. 4. Follow the general and national safety and
accident prevention regulation. 5. Never alter or remove the factory plates
and identification labels. 6. Keep children away from PV & Battery systems. 7.
Never open the device. (No user serviceable parts inside) 8. One set solar
module can connect with one controller only. 9. Never touch bare cables.
OTHER RISKS
Danger of fire and explosion Do not use the solar charge controller in dusty
environments, in the vicinity of solvents or where inflammable gases and
vapors can occur. No open fires, flames or sparks in the vicinity of the
batteries. Ensure that the room is adequately ventilated. Check the charging
process regularly. Follow the charging instructions of the battery
manufacturer.
Battery acid Acid splashes on skin or clothing should be immediately treated
with soap water and rinsed with plenty of water. If acid splashes into the
eyes, immediately rinse with plenty of water. Seek medical advice
Fault behavior Operating the solar charge controller is dangerous in the
following situations:
The solar charge controller does not appear to function at all. The solar
charge controller or connected cables are visibly damaged. Emission of smoke
or fluid penetration. When parts are loose. If any of these occur, immediately
disconnect the solar charge controller from the solar panels and battery.
2
Function
This solar system controller is designed to Monitor the state of charge of the
battery; Controls the charging process, Make sure Solar system works at proper
condition.
OPERATING THE CONTROLLER
The display shows a variety of system data by symbols and digits. Both buttons
control all settings and display windows.
1. Display and operation elements:
50A MPPT Controller SCP-050
1
2
8
3
7
4
6
5
1. Up for toggling through the menus 2. LCD screen 3. Down for toggling through the menus 4. Green LED light (off when not charging,flashing during charging, on when fully charged) 5. Red LED light (off when no error,on when error/alarms) 6. USB output 2 x 3.4A 7. Enter/OK button 8. MENU
9
16
10 11 12 13 14 15
9. Temperature Sensor connecting point 10. PV+ 11. PV12. Battery+ 13.
Battery14. Load+ 15. Load16. RJ45 port. Connected to remote control board
through the network cable (This port is reserved. Do no use)
3
2.Display window:
A. Sun icon, displayed when solar panel is connected. B. Sunlight icon, 8 in
total, display according to the charging current C. MPPT/PWM indication. D.
WIFI icon; turn on WIFI through button settings, read product data and control
load output through APP. E. Remote control icon; displayed when the remote
control is connected (remote control optional). F. Settings icon; turn on when
entering the setting parameters, and turn off when exit. G. Load function
ON/OFF icon; Load ON/OFF optional, default ON. H. Battery level icon; display
the corresponding icon according to the battery voltage. I. Load icon; turn on
when the load is turned on, synchronized with the load switch ON. J.
Connections: Three segments. Top corresponding to PV, middle corresponding to
battery, down corresponding to load. K. Currently identified battery type
(12V/24V/36V/48V). L. Protection icon. When this icon appears, it indicates
that the machine has some protection, such as load overcurrent, short circuit
protection, under-voltage protection, etc. (Refer to the fault code). M. Load
timing clock 2. N. Load timing clock 1. O. Daytime and Night Icons. When PV >
12V it show half sun icon. When PV<12V it show half moon icon. P. Numerical
Display (8888 characters). Can be switched by the mode button to display
Battery Voltage/Load Voltage/PV voltage/time
4
3. Menu Setting:
Menu
Enter
Press the MENU button once, and press again to hold the Menu button for 2 seconds to enter the
setting interface. Press the Menu button again to toggle the mode selection. Press the Enter button to confirm the setting.
Battery Type Selection: There are 3 battery types to select from. S = Standard
lead Acid. L=LiFePO4. A = AGM battery. Us MENU button to toggle and use the
ENTER button to confirm
Wifi On/Off: Default setting is Wifi On. Please use the MENU button to toggle
and press ENTER to confirm
Low voltage protection cut off: When your battery goes down to this voltage
level, the output load will be cut off. Use the UP/DOWN button to toggle
through the voltages and press ENTER to confirm. Setting range of 12V
batteries: 10-11.5V, default 10V; setting range of 24V batteries:
20-23V,default 20V;Setting range of 36V batteries: 30-34.5V,default
30V;setting range of 48V batteries: 40-46V,default 40V.
Low Voltage recovery re-engage: When your battery voltage charged up to this
level, the output load will be re-activate. Setting range of 12V batteries:
12-13V, default 12.5V; setting range of 24V batteries: 24-26V,default
25V;setting range of 36V batteries: 36-39V,default 37.5V;setting range of 48V
batteries: 48-52V,default 50V.
Time setting: This is the time setting in 24 hour format Use UP/DOWN button to
set and press ENTER to confirm.
Factory Reset:
- Remove the battery positive cable that connects the regulator to the battery. Screen should be turned off
- Press and hold the MENU button whilst reconnecting the positive battery cable, the screen shall be lighted up.
- Then, you will see from the display “FFFF”
- Now, all settings should be restored to default
5
4. Load Timing Setting:
Lo Mode: Load On/Off based on the PV input voltage (Day and Night)
When the PV input voltage drops below 10V (during the night time/bad
OFF
weather) you can set the regulator to activate the load output automatically.
Set the Off/On bar to ON by using the UP/DOWN and ENTER button
Clock 1 symbol on. The default is 60 minutes. This means when the PV input voltage drops below 10V, after 60 minutes and load output will be activated. Clock 1 is a power on timer, ranged from 0 120 minutes. Press ENTER to confirm
Next screen you will see the Clock 2 symbol on. The default is 30 minutes.
When the PV input voltage rise up to 10.5V (Morning time), after 30 minutes
the output load will be cut off. It is a power off timer, ranged from 0-120
minutes
Ld Mode: Load On/Off based on a set length of time
It can allow you to set the load output to be activate for a set length of
time
Clock 1 symbol on. The default is 3 hours. When the PV input voltage drops to
10V, the output load will be activate for 3 hours, ranged from 0 12 hours
Clock 2 symbol on. The timer will begin after the Clock 1 counting finished.
In this case, after the PV input voltage drop to 10V (night time), the output
load will power on for 3 hours, and then switch off for 4 hours, then it will
on again until the PV input voltage rise to 10.5V, the load will be cut off.
To mode: Load On/Off based on the real time
It can allow you to set the load on/off based on the real time
Clock 1 symbol on. It is a power on timer, the output load will be activated
at 18:00. Press ENTER to confirm. It is a 24 hour format.
Clock 2 symbol on. It is a power off timer, the output load will cut off at
6:00. Press ENTER to confirm. It is a 24 hour format.
6
TECHNICAL INFORMATION
PV Input
Max. PV Array Power@12V Max. PV Array Power @24V/36V/48V PV Array Voc max. PV Array MPPT Voltage range PV Array open circuit Voltage Range @12V PV Array open circuit Voltage Range @24V PV Array open circuit Voltage Range @36V PV Array open circuit Voltage Range @48V MPPT efficiency Suggested PV cable
Battery Rated Voltage
Battery
Max. Charging Current Max. Charging Voltage
Suggested battery cable Max. Load Burrent
Low Battery Protection Voltage Range (programmable )
DC load & Output
Low Battery Recover Voltage (programmable )
USB Output Voltage Single USB Port Output Current Total Output Current for 2 USB USB Low Battery Protection Voltage USB Low Battery Recover Voltage Standy Current (Wifi off mode) Standy Current (Wifi on mode) Operation Temperature Range Other Function Product Dimension Net Weight
700W 1400W 135VDC 16~108VDC 16~80VDC 32~80VDC 48~108VDC 64~108VDC 99%
8AWG~10AWG 12V STD/AGM/ LiFePO4 24V/36V/48V STD/AGM/50A
STD:14.4V/28.8V/43.2V/57.6V LiFePO4:14.5V/AGM:14.6V/29.2V/43.8V/58.4V 6AWG min
, length <2metre 50A 12V Battery: 10V~11.5V 24V Battery: 20V~23V 36V Battery:
30V~34.5V 48V Battery: 40V~46V
12V Battery: 12V~13V 24V Battery: 24V~26V 36V Battery: 36V~39V 48V Battery:
48V~52V 5V 3A 3.4A 10.5V 11.0V
60mA 160mA -10°C/+50°C WIFI/Cloud 238x177x73mm 2.3kg
7
CHARGING CURVE
Bulk: This is the first stage (MPPT) where the battery is in a low charge
state. During this stage the controller delivers all of the available solar
power to the Battery system. Absorption: In this stage (Constant Voltage) the
controller charges at a constant voltage as the amount of current required to
charge the battery is decreasing. The constant voltage regulation prevents
overheating and excessive battery out-gassing; this stage will end when the
battery charge current reduces to below 4 Amps OR after 4 hours of entering
absorption mode. Float (Maintenance): After the battery is fully charged, the
controller reduces to a lower Constant Voltage setting to maintain the Battery
(also called trickle charge).
PROTECTION FUNCTIONS
Overcharge protection Battery under-voltage protection Solar panel reverse
current protection The following installation faults do not destroy the
controller. After correcting the fault, the device will continue to operate
correctly: Overcharge protection Reverse polarity protection of panel and
battery Automatic electronic fuse Open circuit protection without battery
Reverse current protection at night
MAINTANANCE
The controller is maintenance-free. We strong suggest that all components of
the PV system must be checked at least annually,
Ensure adequate ventilation of the cooling element Check the cable strain
relief Check that all cable connections are secure Tighten screws if necessary
Terminal corrosion
ERROR MESSAGES
Caution! Please do not open the controller or attempt to replace components
when troubleshooting. Improper maintenance can be hazardous to the user and
the system. If the controller detects errors or unauthorized operating states,
it shows error codes on the display. Error codes can generally be
differentiated, whether there is a temporary malfunction, e.g. regulator
overload or a more serious system error that can be remedied by appropriate
external measures. Since not all errors can be simultaneously displayed, the
error with the highest error number (priority) is displayed. If several errors
are present, the second error code is displayed after remedying the more
significant error.
The following meaning is assigned to the different error codes:
8
Fault Codes:
E1 Battery reverse connection / reverse polarity (please correct). E2 Battery
open circuit protection / low DC voltage (battery not connected / or battery
voltage too low,
<8V/18V) E3 Battery over current protection (circuit has constant current
function; the machine may be damaged
if there is a problem). E4 Load over current / short circuit protection (error
10S, turn on the load after eliminating the error). E5 Battery over voltage
(battery damaged or battery voltage too high,>15V/31V/45V/60V). E6 PV (solar)
input over voltage protection. (PV voltage exceed the limit) E7 Over
temperature protection, automatically stop charging when heat sink temperature
90°C;
resume when temperature 60°C. E8 PV reverse connection (please check voltage
and fix) – please ensure polarity is correct. Remark: Please eliminate the
fault according to the error code. If the regulator does not respond after the
error is eliminated remove the power source (battery). If the error still
persists the device may be damaged and may need after sales service.
Temperature Compensation/Temp sensor:
(Only for STD /Lead Acid battery)
1. The system will automatically adjust the float voltage according to the
ambient temperature. If the external temperature probe is not connected (or
the external temperature is <40°C), use (temperature 20°C – 5°C) by default.
2. The voltage may vary when the input energy is insufficient to stabilize the
energy required for the float charging. i. For 12V/24V/36V/48V batteries, when
the external probe temperature 0°C, the float charging voltage
is 14.1V/28.2V/42.3V/56.4V ii. For 12V/24V/36V/48V batteries, when the
external probe temperature is 0°C~20°C, the float charging
voltage is 13.8V/27.6V/41.4V/55.2V iii. For 12V/24V/36V/48V batteries, when
the external probe temperature 20°C, the float charging voltage
is 13.5V/27V/40.5V/54V Remark: If internal head sink temperature exceeds 75
Deg C, the device shall go into approximately half power mode. Shall resume
normal operation when internal head sink drops below 70 Deg C. If internal
head sink exceeds 90 Deg C, the device shall turn off. Shall resume charging
again when temperature drops below 60 Deg C.
9
ECO Solar App
Download the APP by searching ECO SOLAR in Google play/IOS APP store.
1. Main Interface
Main Interface 1. Click Local to enter Local mode 2. Click Cloud to enter
Cloud mode
2. Local
default
disconnected
connected
1. Turn on WiFi according to the prompt, and manually or automatically
connect the WiFi of the device (some mobile phones need to manually connect
the device, password is 12345678)
2. The weather is the current location of the phone 3. After connecting the
device, click V/A/W of PV/Battery/Load for details 4. After connecting the
device, click the OFF/ON switch to control the load switch 5. There are
differences between Android and iOS versions (as follows)
Android
IOS
2.1 Firmware Update
picture1
picture 2 (android)
picture3IOS
1. Click Firmware Upgrade to enter the offline Upgrade interface 2. In the
upgrade interface, switch to the available network (mobile network or
normal WiFi) and click DOWNLOAD FW to DOWNLOAD the latest upgrade package 3.
After downloading the UPGRADE package, connect the device WiFi and click FW
UPGRADE to UPGRADE. There will be corresponding prompts if
the UPGRADE fails or cannot be upgraded 4. If you don’t download the latest
Update package, you can’t click the Update of
IOS version and click the Update of Android version
2.2 Device WiFi Config
Note: this feature is only available near the device 1. Click the search
button to search the WiFi near the phone, or manually input
the corresponding WiFi name (not the WiFi of the device). 2. Due to
permissions, iOS only supports manual input of WiFi name, and
does not support selection of WiFi 3. After entering the corresponding WiFi
password, approach the device
according to the prompt and turn on the bluetooth switch (if the phone has
already turned on the bluetooth switch, there is no hint). Click SMART LINK to
bring the device online to the cloud 4. If you enter the wrong WiFi name or
password, click connect and the device will restart automatically. You need to
wait for the device to restart and re-enter the correct WiFi name and password
5. The device cannot be connected to 5G WiFi, only 2.4GWiFi can be connected
6. After entering the password, it can be saved automatically. Next time, the
password can be displayed automatically by entering or selecting the
corresponding WiFi name 7. When the device is connected to the cloud (check
the WiFi icon of the device is always on), enter the correct WiFi name and
password to switch the device to connect to WiFi (PS: this function is not
available on some phones, please refer to special circumstances for details)
8. When the device is connected to the cloud (check the WiFi icon of the
device
is always on), and the WiFi name or password is incorrectly entered, the
device will not restart, and manual restart is required; Or re-enter the
correct WiFi name and password (PS: this function is not available on some
phones, please refer to special circumstances for details)
2.3 Settings/Version
Android
iOS
1. Click Device ID(Android)/Mac (iOS) to copy the Device address 2. You can check the latest version of the chip and the latest version of the APP
2.4 Log OutOnly iOS
Click to exit to the main screen
3. Cloud
3.1 Register
login interface
register form
1. Click the registration button on the bottom right foot to enter the registration
interface 2. According to the prompt, enter the correct email address as the
login account, and
enter any password as the login password to register
3.1 Forget Password
Forget password interface Enter the correct login email address, verification
code and modified password according to the prompt to modify the password.
There are corresponding prompts for input errors
3.2 Login In
Enter the correct account password to log in successfully, input errors have
corresponding prompts
3.3 Cloud Interface
Cloud function interface 1. After login, bind the Device (Device can connect
WiFi to enter cloud mode through
Device WiFi Config). When the Device is online, the Device functions can be
remotely controlled 2. After the device is online, click the OFF/ON switch to
control the load switch 3. Click the left and right date button to view the
latest date data; You can also click the date directly to select the
corresponding date to view the data 4. UI differences between android and IOS
(as shown below)
Android1
Android2
IOS
3.4.1 Bind Device
You can bind the device by directly entering or clicking the icon on the right
to scan the QR code
3.4.2 Device WiFi Config
Device WiFi Config for local mode
3.4.3 Set Local Mode/Set Device Local Mode
Click and a prompt box will pop up. Click OK to set the device to local mode.
Click CANCEL and it will do nothing
3.4.4 Firmware Update/Device Upgrade
Click and a prompt box will pop up. Click OK and the device will be
automatically updated to the latest version. Click CANCEL and it will do
nothing
3.3.5 System Settings
1. Load voltage can be viewed, not selected and modified 2. Select the
appropriate Battery Type for the loaded Battery 3. Turn on or off the switch
to control whether the timer function is enabled; After
opening the switch, you can select different time types and modify the time
period to enable different timer functions 4. When there is an error in
modifying low-voltage protection data and overvoltage recovery data, the
corresponding range prompt will pop up
3.4.6 VersioniOS
Consistent with local mode functionality
3.4.7 logout
Click and return to the cloud login interface
4. Special Situation
Due to unstable bluetooth connection when the device is in cloud mode, some
mobile phones cannot connect to the device via bluetooth 1. When the device is
in local mode, if WIFI can not be connected by using the Device
WiFi Config function, please restart the device manually so that you can re-
set the device to the local mode. Then, re-use the Device WiFi Config function
to bring the device to the cloud. 2. The device is in the cloud mode. When
WiFi connection is unavailable, restart the device and the device cannot be
set to local mode. Please forcibly reset the device and reconnect to the new
WiFi
Read User Manual Online (PDF format)