BUILTBRIGHT BB6010B Work BAR STROBE 4 Installation Guide
- August 28, 2024
- BUILTBRIGHT
Table of Contents
BUILT RIGHT BB6010B Work BAR STROBE 4
SPECIFICATIONS
- Input Voltage: 12-24VDC
- Operating Current: 0.84A @ 12VDC
- Operating Temperature: -40° to 149°F (-40° to 65°C)
INCLUDED
- 1x LED light bar
- 1x Mounting Bezel
- 1x 3M VHB tape
- 1x Mounting Gasket
- Mounting hardware
INSTALLATION
- Mount to a flat surface or one with minimal curvature.
- Mark drill hole locations on the mounting surface using the gasket or VHB tape as a template.
- Drill a 9/16” (14mm) hole for the wires protruding from the rear of the unit at the correct location. Deburr any sharp edges from this hole.
- Mount the light along with the mounting gasket. Use the self-tapping screws provided to secure.
WIRING
- Apply YELLOW wire to +VDC:
- Less than 1 second for the next pattern
- 2-4 seconds for the previous pattern
- 5-7 seconds for the default pattern
- 7+ seconds for steady burn
- Synchronization: After setting each light in the right pattern, connect the yellow wires of all light heads.
- Phase Operation: Phase 1 flashes simultaneously with Phase 1, Phase 2 flashes simultaneously with Phase 2, Phase 1 alternates with Phase 2 (Up to 8 units can be synchronized.)
FLASH PATTERNS
FLASH PATTERNS
1| (Amber) Single Flash, ECE R65 Phase 1#| 27| (Amber) Strobe
2| (Amber) Single Flash, California Title 13 Phase 1| 28| (Amber) Cruise
(20%)
3| (Amber) Double Flash Phase 1| 29| (Color 2) Single Flash, ECE R65 Phase 2
4| (Amber) Triple Flash Phase 1| 30| (Color 2) Single Flash, California Title
13 Phase 1
5| (Alt. Amber-Color 2) Single Flash| 31| (Color 2) Single Flash, California
Title 13 Phase 2
6| (Alt. Amber-Color 2) Double Flash| 32| (Color 2) Double Flash Phase 1
7| (Alt. Amber-Color 2) Quadruple Flash| 33| (Color 2) Double Flash Phase 2
8| (Alt. Amber-Color 2) Faster Full Bar| 34| (Color 2) Triple Flash Phase 1
9| (Split Amber-Color 2) Left/Right| 35| (Color 2) Triple Flash Phase 2
10| (Split Amber-Color 2) Fast Left/Right| 36| (Color 2) Quadruple Flash
Phase 1
11| (Alt. Amber-Color 2) Combination*| 37| (Color 2) Quadruple Flash Phase 2
12| (Amber) Single Flash, ECE R65 Phase 2| 38| (Color 2) Quintuple Flash Phase
1
13| (Amber) Single Flash, California Title 13 Phase 2| 39| (Color 2) Quintuple
Flash Phase 2
14| (Amber) Double Flash Phase 2| 40| (Color 2) Combo Single/Double Flash
Phase 1
15| (Amber) Triple Flash Phase 2| 41| (Color 2) Combo Single/Double Flash
Phase 2
16| (Amber) Quadruple Flash Phase 1| 42| (Color 2) Combo Single/Triple Flash
Phase 1
17| (Amber) Quadruple Flash Phase 2| 43| (Color 2) Combo Single/Triple Flash
Phase 2
18| (Amber) Quintuple Flash Phase 1| 44| (Color 2) Combo Single/Quintuple
Flash Phase 1
19| (Amber) Quintuple Flash Phase 2| 45| (Color 2) Combo Single/Quintuple
Flash Phase 2
20| (Amber) Combo Single/Double Flash Phase 1| 46| (Color 2) Single Flash
Left/Right Split
21| (Amber) Combo Single/Double Flash Phase 2| 47| (Color 2) Strobe
22| (Amber) Combo Single/Triple Flash Phase 1| 48| (Color 2) Cruise (20%)
23| (Amber) Combo Single/Triple Flash Phase 2| 49| (Amber) Steady Burn
24| (Amber) Combo Single/Quintuple Flash Phase 1| 50| (Split Amber – Color 2)
Quadruple Flash
25| (Amber) Combo Single/Quintuple Flash Phase 2| 51| (Alt. Amber – Color 2)
Single Flash
26| (Amber) Single Flash Left/Right Split|
- Sync w/ 6002X Series Mini Bar # Default pattern
- Color 2: White (BB6010B) Blue (BB6010C) Green (BB6010D)
WARRANTY
ARC Lighting provides a 5-year warranty against manufacturing defects from the date of purchase. If warranty service is needed, please contact the authorized dealer where your product(s) were originally purchased.
Customer Support
- Phone: 888-608-2220
- Email: support@arc.lighting
- Website: www.arc.lighting/warranty-claim
- WARNING: CANCER AND REPRODUCTIVE HARM WWW.P65WARNINGS.CA.GOV