BRISTAN MPL EFSNK SS Maple Easyfit Mono Sink Mixe
Specifications
- Dynamic Water Pressure:
- Min: 0.3 bar
- Max: 5.0 bar
- Inlet Water Temperature: MPL EFSNK SS (D2) Outlet
- Inlet Connections: 1/2 BSP
- Maximum Static Pressure: 10.0 bar
Product Usage Instructions
Features
- Eco Start
- Temperature Control.
Installation
- Remove the protective cap from the base assembly.
- Feed the base through the sink hole from the top.
- Ensure the base is centralised when viewed from the front of the tap.
- Turn the hexagonal key clockwise until the base is secured.
- Screw the flexible tails into the base. DO NOT OVER-TIGHTEN.
- Connect the hot and cold water connections.
- Grease the O-Rings using the provided Molykote Grease.
- Place your desired tap onto the base.
- Secure in place with the grub screws using the tool provided.
- Thread the hexagonal key through the EasyFit tool and tighten the grub screws with an extra 1/2 turn.
Maintenance
- General Cleaning
- Maintenance – Replacing Cartridge
FAQ
- Q: Where can I find full Installation Requirements & Notes?
A: For full Installation Requirements & Notes (IRN) please visit www.wrasapprovals.co.uk/approvals-directory
Installation Instructions & User Guide
Please leave these instructions with the end user
Specifications
Prior to Installation
-
All products manufactured and supplied by Bristan are safe to use provided that they are installed, operated and receive regular maintenance in accordance with these instructions.
This product needs to be installed in accordance with, and meet the requirements of The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009 and The Water Supply (Water Fittings) (Scotland) Byelaws 2014. For full Installation Requirements & Notes (IRN) please visit www.wrasapprovals.co.uk/approvals-directory -
Isolation valves must be fitted to the inlet water supplies to ensure ease of future maintenance.
-
Before installing this product the water supply must be thoroughly flushed in order to remove any swarf, solder etc. Full access must be made available for future maintenance/servicing purposes.
-
This product must not be modified in any way as this will invalidate the guarantee.
Spare Parts
To replace any spare parts for your tap, why not scan the QR Code or visit www.bristan.com and search for your product.
Installation
General Cleaning
- Bristan products are made from premium materials, with hand polished, PVD, EPD or electroplated finishes.
- Your tap should be regularly cleaned with warm water, a mild pH-neutral liquid soap, and polished with a soft cloth. Any residues from soap, toothpaste, shampoos and shower gels can cause blemishes if not rinsed off straight after use.
- Household bleaches and cleaners contain harsh chemicals and may damage the surface finish. Avoid using abrasive cloths, scouring pads, scrub sponges, steel wool or anything similar.
- Some surfaces such as nickel and pewter may be affected by the dye found in some cloths, so it is also important to avoid hanging cloths on spouts.
Maintenance – Replacing Cartridge
Alternative Installation for Surfaces Out of Tolerance/Extra Stability
Troubleshooting
Troubleshooting|
---|---
Symptom| Cause(s)| Remedy
No flow or low flow rate| Partially closed isolation valve.| Open isolation
valve.
Head of water is below the minimum distance required.| Refer to your the
Specification for the minimum working pressure/distance required.
Hot or cold water being drawn off elsewhere causing pressure changes or
instantaneous boiler temperature changes.| Do not use other water outlets when
using the taps.
Airlock or partial blockage in the supply pipework or hoses.| Flush through
pipework to ensure removal of debris and any airlocks.
Water supply failure| Investigate water supply. Check your plumbing and
heating systems for any faults.
Water dripping from taps| This is normal for a short time after using the
taps.| This is caused by residual water tension, the build up of water in the
tap body.
If water continues to drip, possibly due to the ceramic disc valves/cartridge|
Refer to the Maintenance section to replace the valves/cartridge.
Taps do not turn on| Closed isolation valve.| Open isolation valve.
Mains water supply turned off.| Turn on mains water supply.
Wobbly Tap| Grub screws are not tight enough at the base| Ensure the grub
screws are fully tightened against the base
Extra security may be required depending on the surface the tap is fitted on
to.| Refer to the Alternative Installation steps in order to fit the
Reinforcing Plate.
Maintenance – Clean/Replace Outlet
Contact Us
Bristan Group Ltd.
UK: Bristan Group, B78 1SG.
EU: Masco Europe S.à.r.l.
14 Rue Strachen
6933 Mensdorf
Luxembourg
Customer Service: +44330 026 6273
Web: www.bristan.com
Email: enquire@bristan.com
A Masco Company
Our Guarantee
- At Bristan, we want to make things as easy as possible for our customers. That’s why we offer solid guarantees on all our products, effective from the date of purchase, to give you peace of mind.
- To start your free guarantee simply scan the QR code and register your product.
- Alternatively visit www.bristan.com/register
- For any other queries, please call our Customer Service on 0330 026 6273 where our expert team of advisors will be able to offer you any help and advice.
- For full guarantee terms and conditions visit www.bristan.com/service-centre/guarantees.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>