AcuityBrands LED Lithonia TruWrap Wrap Linear Flush Mount Instruction Manual
- August 29, 2024
- AcuityBrands
Table of Contents
AcuityBrands LED Lithonia TruWrap Wrap Linear Flush Mount
Product Information
Specifications
- Brand: Lithonia
- Model: TruWrap
- Installation: Ceiling-mounted luminaire
- Usage: Indoor lighting fixture
Product Usage Instructions
- If the ceiling junction box does not have mounting screws, use the provided #10 screws to secure the fixture.
- Align and secure the luminaire to the ceiling junction box by following the provided steps.
- Connect the wires from the luminaire to the junction box wires, ensuring proper color-coding.
- Secure all connections with wire nuts and reinstall the luminaire to the ceiling, ensuring it is properly aligned and tightened.
- Attach the diffuser by aligning one edge with the housing flange and wrapping it securely around the housing.
FAQ
- Q: What should I do if I encounter difficulties during installation?
- A: If you face challenges during installation, refer to the detailed installation instructions provided in the manual. If issues persist, contact customer support for assistance.
- Q: Can this luminaire be used outdoors?
- A: No, this product is designed for indoor use only. Outdoor usage may result in damage to the luminaire.
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
- Installation and service of luminaires should be performed by a qualified licensed electrician.
- Maintenance of the luminaires should be performed by a person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended
- It will occasionally be necessary to clean the outside of the refractor/lens. The frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to the user. The refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water, and wiped dry. Should the optical assembly become dirty on the inside, wipe the refractor/lens and clean in the above manner, replacing damaged gaskets as necessary.
- DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
- Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise that are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING
RISK OF ELECTRIC SHOCK
- Disconnect or turn off power before installation or servicing.
- Verify that the supply voltage is correct by comparing it with the luminaire label information.
- Make all electrical and grounded connections per the National Electrical Code (NEC) and any applicable local code requirements.
- All wiring connections should be capped with UL approved recognized wire connectors.
WARNING
RISK OF BURN
- Allow lamp/fixture to cool before handling.
- Do not touch the enclosure or light source.
- Do not exceed the maximum wattage marked on the luminaire label.
- Follow all manufacturer’s warnings, recommendations, and restrictions for driver type, burning position, mounting locations/methods, replacement and recycling.
CAUTION
RISK OF INJURY
- Wear gloves and safety glasses at all times when removing luminaire from cartons, installing, servicing or performing maintenance.
- Avoid direct eye exposure to the light source while it is on.
CAUTION
RISK OF FIRE
- Keep combustible and other materials that can burn, away from lamp/lens.
- Do not operate close to persons, combustible materials or substances affected by heat or drying.
CAUTION: RISK OF PRODUCT DAMAGE
- Never connect components under load.
- Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
- Controls for dimming, auto-sensing, or remote control of a luminaire that are not factory-wired to the luminaire must be checked for compatibility with the luminaire before installation. LED fixtures must be powered directly off a switched circuit.
- Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around the fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
- Unless individual product specifications deem otherwise: Do not exceed fixtures’ maximum ambient temperature.
- Only use fixture in its intended location.
- LED products are Polarity Sensitive. Ensure proper Polarity before installation.
- Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
- Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
- Some components inside the fixture may not be serviceable. In the unlikely event, your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
- Always read the fixture’s complete installation instructions before installation for any additional fixture-specific warnings.
- Always ensure that the electrical distribution system is up to NEC (and any applicable local code) requirements.
- Verify that the power distribution system has proper grounding. Lack of proper earth ground can lead to fixture failure and may void the warranty.
FCC STATEMENT
Choose either Port 15 OR Part 18 and move to Page 3 Installation Instructions
under Delivery. Lithonia Outdoor will always use Part 15.
All luminaires that contain electronic devices that generate frequencies above
9kHz from any component within the luminaire comply with Part 15 of the FCC
Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference
- This device must accept any interference received, including interference that may cause undesired operation
This device complies with Part 18 of the FCC Rules but may cause interference with cordless and cell phones, radios, televisions, and other electronic devices. To correct the problem, move the device away from the luminaire or plug into a different outlet. This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communications equipment operating between 0.45-30MHz.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.
Our Brands
- Indoor/Outdoor
- Lithonia Lighting
- Carandini
- Holophane
- RELOC
- light Concepts
- Indoor Lighting
- Aculux
- Gotham
- Indy
- Junc
- Mark Architectural Lighting
- Peeress
- Renaissance Lighting
- Winona Lighting
- Outdoor Lighting
- American Electric Lighting
- Antique Street Lamps
- Hydrel
- Terser
- Controls
- DARK TO LIGHT
- ICSD
- ROAM
- Sensor Switch
- Synergy
- Daylighting
- Synaptics
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out
of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203 © 2010, 2016 Acuity Brands
Lighting, Inc. All rights reserved. 12/01/10
THIS PRODUCT MUST BE INSTALLED UNDER THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED
Installation Instructions
Caution: MAKE SURE LUMINAIRE IS MOUNTED TO A SECURE STRUCTURE. USE
APPROPRIATE MOUNTING HARDWARE TO INSTALL FIXTURE RATED FOR YOUR APPLICATION.
FAILURE TO MOUNT THE FIXTURE CORRECTLY COULD RESULT IN SERIOUS INJURY.
KEEP THESE INSTALLATION INSTRUCTIONS / CONSERVEZ CES INSTRUCTIONS
D’INSTALLATION
STEP 1
- A: Place the luminaire on a flat surface with the diffuser facing up towards the ceiling. Slide the fingertips of both hands between the diffuser and the surface the luminaire is laying on.
- Grip the edge of the diffuser and gently pry it away from the housing while simultaneously pulling up to disengage it from the housing. As the diffuser starts to disengage, walk your fingertips down the length of the diffuser, repeating the same prying and pulling motion until the entire side of the diffuser detaches from the housing. Once one side is detached, the opposite side of the diffuser will pull away from the housing by itself. Follow these steps carefully to ensure the diffuser is removed without damage.
STEP 2
- A: If the ceiling junction box does not already have existing mounting screws installed, follow these steps to secure the fixture:
- Find the two #10 screws provided with the fixture. Position the screws over the mounting holes in the junction box. Start inserting the screws into the mounting holes of the junction box.
- Secure the screws to the junction box, leaving 1/4 inch of each screw exposed. This exposed portion will be used for mounting the fixture securely.
STEP 3
- To secure the luminaire to the ceiling junction box, follow these steps: Align the two center keyhole slots on the housing with the two #10 screws fastened to the ceiling junction box. Turn the luminaire a quarter turn to lock it in place, ensuring both #10 screws engage with the keyhole slots as shown. Do not tighten screws at this point, this is just a means to free up both hands to connect the luminaire wires to the supply lines.
- Connect the white wire from the luminaire to the neutral wire (usually white) from the junction box.
- Connect the black wire from the luminaire to the line wire (usually black) from the junction box. Connect the bare copper wire from the luminaire to the ground wire (usually bare or green) from the junction box.
STEP 4
- Ensure all connections are secure and use wire nuts to cover each connection. After connecting the wires, carefully remove the luminaire from the junction box tuck the wire into the junction box.
- Reinstall the luminaire to the ceiling making sure both #10 screws are engaged in the key hole slots as shown. Tighten the keyhole screws to ensure the luminaire is secured in place.
STEP 4
To ensure the luminaire sits flush with the mounting surface, follow these steps to secure it with the appropriate fasteners: Locate the four standoff bosses on the luminaire housing. Choose appropriate fasteners based on the ceiling surface:
- Wood screws for wooden surfaces
- Anchored screws for drywall or plaster
- Toggle bolts for hollow ceilings
- Masonry screws for concrete or brick surfaces
Tighten the fasteners to ensure the luminaire is securely mounted and sits
flush with the ceiling surface.
Double-check that the luminaire is stable and properly aligned before
finishing the installation.
Fasteners supplied by others
STEP 5
Align one edge of the diffuser with the housing flange. Rest the other edge of the diffuser on the housing. Wrap your fingertips around the diffuser edge. Gently pull one end of the diffuser away from and over the housing flange. Continue this wrapping and pulling motion down the full length of the diffuser until it is securely wrapped around the housing flange.
STEP 6
- C: Ensure that the diffuser is evenly and securely wrapped around the housing flange on both sides. Once secured, the full length of the diffus- er on both sides freely rests on the housing flange, as shown.
STEP 7
- CCT: Luminaire’s default color temperature is set to 4000K. The CCT can be manually changed to 3000K, 4000K or 5000K using the switch located on the left side of the endcap as shown.
- ALO: The luminaires default adjustable Lumen out- put is set to high. The Lumen level can manually be changed to low, medium or high using the switch located on the right side of the endcap as shown.
Contractor Resources
- Check out helpful programs, tools, installation videos and more!
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>