ASSURED DAQ-PACK M Series Multi Channel High Speed Analog I/O Family User Guide

August 27, 2024
ASSURED

DAQ-PACK M Series Multi Channel High Speed Analog I/O Family

Specifications:

  • Product Name: ACCES I/O DPK-AIO/DPK-AI-XX-XXXX
  • Model: DAQ-PACK M Series
  • Type: Multi-Channel High-Speed Analog I/O Family
  • Enclosure: Rugged steel enclosure
  • Manufacturer: ACCES

Product Usage Instructions:

1. Safety Precautions:

It is crucial to follow these safety precautions to avoid damage
to the DAQ-PACK and ensure warranty validity:

  • Always connect and disconnect field cabling with the computer
    power off.

  • Turn power off before connecting and disconnecting cables.

  • Do not open the enclosure as it will void the warranty.

2. Warranty Information:

ACCES provides warranty coverage for its equipment. Here are the
key points:

  • First Three Years: Repair or replacement at no charge for labor
    or parts not excluded by warranty.

  • Following Years: On-site or in-plant service available at
    reasonable rates.

  • Equipment Not Manufactured by ACCES: Repaired according to
    respective manufacturer’s warranty.

3. Introduction and Installation:

The DAQ-PACK M Series is a fully factory configured and
integrated multi-function data acquisition model. Follow these
steps for installation:

  1. Refer to the comprehensive manuals for technical details.

  2. Ensure the computer power is off before connecting or
    disconnecting cabling.

  3. Do not open the enclosure to maintain warranty validity.

FAQ:

Q: What should I do if my DAQ-PACK encounters equipment

failure?

A: In case of equipment failure, contact ACCES for prompt
service and support. The equipment is covered under warranty for
repair or replacement based on the warranty terms.

Q: Can I open the enclosure of the DAQ-PACK?

A: No, opening the enclosure will void the warranty. The
DAQ-PACK is fully factory configured, and any interference with the
enclosure may lead to damage and warranty voidance.

ACCES I/O DPK-AIO/DPK-AI-XX-XXXX Get Quote
10623 Roselle Street, San Diego, CA 92121 y 858-550-9559 y Fax 858-550-7322 contactus@accesio.com y www.accesio.com
DAQ-PACK M SERIES MULTI-CHANNEL HIGH-SPEED
ANALOG I/O FAMILY USER GUIDE

File: DAQ-PACK M Series Guide.A1a

www.assured-systems.com | sales@assured-systems.com

Page 1/15

ACCES I/O DPK-AIO/DPK-AI-XX-XXXX Get Quote

Notice
The information in this document is provided for reference only. ACCES does not assume any liability arising out of the application or use of the information or products described herein. This document may contain or reference information and products protected by copyrights or patents and does not convey any license under the patent rights of ACCES, nor the rights of others. IBM PC, PC/XT, and PC/AT are registered trademarks of the International Business Machines Corporation. Copyright by ACCES I/O Products, Inc. 10623 Roselle Street, San Diego, CA 92121. All rights reserved.
WARNING!! ALWAYS CONNECT AND DISCONNECT YOUR FIELD CABLING WITH THE
COMPUTER POWER OFF. ALWAYS TURN POWER OFF BEFORE CONNECTING AND DISCONNECTING CABLES, FAILURE TO DO SO MAY CAUSE DAMAGE TO THE DAQ-PACK AND WILL VOID ALL WARRANTIES,
IMPLIED OR EXPRESSED.
CAUTION!! THE DAQ-PACK SERIES IS A FULLY FACTORY CONFIGURED AND INTEGRATED INSTRUMENT, DO NOT OPEN THE ENCLOSURE, DOING SO
WILL VOID YOUR WARRANTY
Warranty
Prior to shipment, ACCES equipment is thoroughly inspected and tested to applicable specifications. However, should equipment failure occur, ACCES assures its customers that prompt service and support will be available. All equipment originally manufactured by ACCES which is found to be defective will be repaired or replaced subject to the following considerations.
Terms and Conditions If a unit is suspected of failure, contact ACCES’ Customer Service department. Be prepared to give the unit model number, serial number, and a description of the failure symptom(s). We may suggest some simple tests to confirm the failure. We will assign a Return Material Authorization (RMA) number which must appear on the outer label of the return package. All units/components should be properly packed for handling and returned with freight prepaid to the ACCES designated Service Center, and will be returned to the customer’s/user’s site freight prepaid and invoiced.
Coverage First Three Years: Returned unit/part will be repaired and/or replaced at ACCES option with no charge for labor or parts not excluded by warranty. Warranty commences with equipment shipment. Following Years: Throughout your equipment’s lifetime, ACCES stands ready to provide on-site or in-plant service at reasonable rates similar to those of other manufacturers in the industry.
Equipment Not Manufactured by ACCES Equipment provided but not manufactured by ACCES is warranted and will be repaired according to the terms and conditions of the respective equipment manufacturer’s warranty.
General Under this Warranty, liability of ACCES is limited to replacing, repairing or issuing credit (at ACCES discretion) for any products which are proved to be defective during the warranty period. In no case is ACCES liable for consequential or special damage arriving from use or misuse of our product. The customer is responsible for all charges caused by modifications or additions to ACCES equipment not approved in writing by ACCES or, if in ACCES opinion the equipment has been subjected to abnormal use. “Abnormal use” for purposes of this warranty is defined as any use to which the equipment is exposed other than that use specified or intended as evidenced by purchase or sales representation. Other than the above, no other warranty, expressed or implied, shall apply to any and all such equipment furnished or sold by ACCES.
DAQ-PACK M Series Modules User Guide 2

www.assured-systems.com | sales@assured-systems.com

Page 2/15

ACCES I/O DPK-AIO/DPK-AI-XX-XXXX Get Quote
TABLE OF CONTENTS
Chapter 1: Introduction and Installation ……………………………………………………………………………………………… 4 Included with your DAQ-PACK M Series Module ……………………………………………………………………………… 4 Optional Mounting Accessories ………………………………………………………………………………………………………. 4 Figure 1-1: Block Diagram……………………………………………………………………………………………………………. 5
Chapter 2: Mechanical Drawings ………………………………………………………………………………………………………… 6 Figure 2-1: DAQ-PACK M Series Enclosure ………………………………………………………………………………….. 6 Figure 2-2: DAQ-PACK Mounting Provisions………………………………………………………………………………… 6 Figure 2-3: DPK-DIN-CLIP…………………………………………………………………………………………………………….. 7 Figure 2-4: DPK-MOUNT ………………………………………………………………………………………………………………. 7
Chapter 3: USB Address Information………………………………………………………………………………………………….. 8 Table 3-1: Product ID to Model Number………………………………………………………………………………………… 8
Chapter 4: Programming ……………………………………………………………………………………………………………………. 9 Chapter 5: Connector Pin Assignments ……………………………………………………………………………………………. 10
Table 5-1: J1 Connector Pin Assignments (DB37F) …………………………………………………………………….. 10 Table 5-2: J2 Connector Pin Assignments (DB37F) …………………………………………………………………….. 11 Table 5-3: J1 and J2 Signal Names and Descriptions ………………………………………………………………….. 11 Table 5-4: J3 Connector Pin Assignments (DB25F) …………………………………………………………………….. 12 Table 5-5: J3 Signal Names and Descriptions……………………………………………………………………………… 12 Chapter 6: Primary Specifications …………………………………………………………………………………………………….. 13 Customer Comments ……………………………………………………………………………………………………………………….. 14

3
www.assured-systems.com | sales@assured-systems.com

DAQ-PACK M Series Modules User Guide
Page 3/15

ACCES I/O DPK-AIO/DPK-AI-XX-XXXX Get Quote

Chapter 1: Introduction and Installation

This guide describes the DAQ-PACK M Series of Enclosed Multi-function Data Acquisition Models. These are fully factory configured and integrated into a rugged steel enclosure.

This guide provides all of the information most users will need. For full technical details and specifications, refer to the following comprehensive manuals:

z USB-AIO Series.PDF z USB Software Reference.pdf

USB Multi-Channel High-Speed Analog I/O Family Models USB-AIO16-xxx and USB- AIO12-xxx USB Software Reference Manual

As the DAQ-PACK M Series is factory integrated into the enclosure, there should be no need for users to open the box. Doing so may void your warranty. For technical assistance, please contact us toll-free at 800-326-1649 and a technician will be happy to help you.

Included with your DAQ-PACK M Series Module

The following components are included with your shipment depending on model and options ordered. Please take time now to ensure that no items are damaged or missing.

z DAQ-PACK M Series Module installed in an enclosure with an anti-skid bottom z 6′ USB 2.0 Type A to B cable z Software Master CD (PDF reference manuals installed with product package) z Printed DAQ-PACK Series User Guide

Optional Mounting Accessories

Drawings of these accessories are in Chapter 2 of this guide.

DPK-DIN-CLIP DPK-MOUNT

DIN rail mounting clip w/3 x 8/32 FHP 3/8″ SS screws Panel mounting plate w/3 x 8/32 FHP 3/8″ SS screws

4
www.assured-systems.com | sales@assured-systems.com

DAQ-PACK M Series Modules User Guide
Page 4/15

ACCES I/O DPK-AIO/DPK-AI-XX-XXXX Get Quote

Figure 1-1: Block Diagram

5
www.assured-systems.com | sales@assured-systems.com

DAQ-PACK M Series Modules User Guide
Page 5/15

ACCES I/O DPK-AIO/DPK-AI-XX-XXXX Get Quote
Chapter 2: Mechanical Drawings

Figure 2-1: DAQ-PACK M Series Enclosure

Figure 2-2: DAQ-PACK Mounting Provisions
DAQ-PACK M Series Modules User Guide 6

www.assured-systems.com | sales@assured-systems.com

Page 6/15

ACCES I/O DPK-AIO/DPK-AI-XX-XXXX Get Quote Figure 2-3: DPK-DIN-CLIP

Figure 2-4: DPK-MOUNT

7
www.assured-systems.com | sales@assured-systems.com

DAQ-PACK M Series Modules User Guide
Page 7/15

ACCES I/O DPK-AIO/DPK-AI-XX-XXXX Get Quote

Chapter 3: USB Address Information
Use the provided driver to access the DAQ-PACK M Series. This driver will allow you to determine how many supported USB devices are currently installed, and each device’s type. This information is returned as a Vendor ID (VID), Product ID (PID) and Device Index.
The VID is “0x1605” and the PID is listed in the following table.

8045 8046 8047 8048 8049

USB-AI16-64MA USB-AI16-64ME USB-AI12-64MA USB-AI12-64M USB-AI12-64ME

8145 8146 8147 8148 8149

USB-AIO16-64MA USB-AIO16-64ME USB-AIO12-64MA USB-AIO12-64M USB-AIO12-64ME

Table 3-1: Product ID to Model Number

8
www.assured-systems.com | sales@assured-systems.com

DAQ-PACK M Series Modules User Guide
Page 8/15

ACCES I/O DPK-AIO/DPK-AI-XX-XXXX Get Quote
Chapter 4: Programming
The driver software provided with the board uses a 32-bit .dll front end compatible with any Windows programming language. Samples provided in Borland C++Builder, Borland Delphi, Microsoft Visual Basic, and Microsoft Visual C++ demonstrate the use of the driver.
The easiest way to begin taking analog input data is using the following API call, but often can’t achieve more than several hundred Hz, slower depending on options.
unsigned long ADC_GetScanV( – This simple function takes one scan of A/D data and converts it to voltage. It also averages oversamples for each channel. The array must contain one entry per A/D channel on the board, though only entries [start channel] through [end channel] are altered. On boards with A/D that don’t support ADC_SetConfig(), it scans all channels, without oversampling. unsigned long DeviceIndex – number from 0-31 indicating from which device you wish to get a scan of data double *pBuf – a pointer to the first of an array of double precision IEEE floating point numbers which will each receive the value read from one channel )
For full programming details see the USB Software Reference Manual installed on your system along with the product software package.

9
www.assured-systems.com | sales@assured-systems.com

DAQ-PACK M Series Modules User Guide
Page 9/15

ACCES I/O DPK-AIO/DPK-AI-XX-XXXX Get Quote

Chapter 5: Connector Pin Assignments

The DAQ-PACK M Series is available in five basic flavors, always consisting of the USB interface and A/D board and one AIMUX-64 multiplexer board. The A/D board may also have two 16-bit analog outputs (specify at time of ordering). Signals present on these connectors are as follows:

Connectors P1 USB Type B J1 DB37 Female
J2 DB37 Female J3 DB25 Female DC POWER

High Retention Connector for reliable USB Interface Ch 0-15 differential & S.E. Ch 32-47 S.E. analog inputs and temp sensor Ch 16-31 differential & S.E. Ch 48-63 S.E. analog inputs A/D control and digital I/O Optional External Regulated 5V Power Input

Pin Signal Name

1 CH0(SE) / CH0+(DIFF)

2 CH1(SE) / CH1+(DIFF)

3 CH2(SE) / CH2+(DIFF)

4 CH3(SE) / CH3+(DIFF)

5 CH4(SE) / CH4+(DIFF)

6 CH5(SE) / CH5+(DIFF)

7 CH6(SE) / CH6+(DIFF)

8 CH7(SE) / CH7+(DIFF)

9 AGND

10 CH8(SE) / CH8+(DIFF)

11 CH9(SE) / CH9+(DIFF)

12 CH10(SE) / CH10+(DIFF)

13 CH11(SE) / CH11+(DIFF)

14 CH12(SE) / CH12+(DIFF)

15 CH13(SE) / CH13+(DIFF)

16 CH14(SE) / CH14+(DIFF)

17

CH15(SE) / CH15+(DIFF) / LM335+ term.

18 AGND / LM335- terminal

19 AGND

Pin Signal Name 20 CH32(SE) / CH0-(DIFF) 21 CH33(SE) / CH1-(DIFF) 22 CH34(SE) / CH2-(DIFF) 23 CH35(SE) / CH3-(DIFF) 24 CH36(SE) / CH4-(DIFF) 25 CH37(SE) / CH5-(DIFF) 26 CH38(SE) / CH6-(DIFF) 27 CH39(SE) / CH7-(DIFF) 28 CH40(SE) / CH8-(DIFF) 29 CH41(SE) / CH9-(DIFF) 30 CH42(SE) / CH10-(DIFF) 31 CH43(SE) / CH11-(DIFF) 32 CH44(SE) / CH12-(DIFF) 33 CH45(SE) / CH13-(DIFF) 34 CH46(SE) / CH14-(DIFF) 35 CH47(SE) / CH15-(DIFF) 36 AGND
37 AGND(AI) / DAC0 (AIO)

Table 5-1: J1 Connector Pin Assignments (DB37F)

DAQ-PACK M Series Modules User Guide 10

www.assured-systems.com | sales@assured-systems.com

Page 10/15

ACCES I/O DPK-AIO/DPK-AI-XX-XXXX Get Quote

Pin Signal Name

1 CH16(SE) / CH16+(DIFF)

2 CH17(SE) / CH17+(DIFF)

3 CH18(SE) / CH18+(DIFF)

4 CH19(SE) / CH19+(DIFF)

5 CH20(SE) / CH20+(DIFF)

6 CH21(SE) / CH21+(DIFF)

7 CH22(SE) / CH22+(DIFF)

8 CH23(SE) / CH23+(DIFF)

9 AGND

10 CH24(SE) / CH24+(DIFF)

11 CH25(SE) / CH25+(DIFF)

12 CH26(SE) / CH26+(DIFF)

13 CH27(SE) / CH27+(DIFF)

14 CH28(SE) / CH28+(DIFF)

15 CH29(SE) / CH29+(DIFF)

16 CH30(SE) / CH30+(DIFF)

17

CH31(SE) / CH31+(DIFF) / LM335 + terminal

18 AGND / LM335 ­ terminal

19 AGND

Pin Signal Name 20 CH48(SE) / CH16-(DIFF) 21 CH49(SE) / CH17-(DIFF) 22 CH50(SE) / CH18-(DIFF) 23 CH51(SE) / CH19-(DIFF) 24 CH52(SE) / CH20-(DIFF) 25 CH53(SE) / CH21-(DIFF) 26 CH54(SE) / CH22-(DIFF) 27 CH55(SE) / CH23-(DIFF) 28 CH56(SE) / CH24-(DIFF) 29 CH57(SE) / CH25-(DIFF) 30 CH58(SE) / CH26-(DIFF) 31 CH59(SE) / CH27-(DIFF) 32 CH60(SE) / CH28-(DIFF) 33 CH61(SE) / CH29-(DIFF) 34 CH62(SE) / CH30-(DIFF) 35 CH63(SE) / CH31-(DIFF) 36 AGND
37 AGND (AI) / DAC1(AIO)

Table 5-2: J2 Connector Pin Assignments (DB37F)

Signal Name
Ch0 thru Ch31(SE)/Ch0+ thru Ch31+ (DIFF) Ch32 thru Ch63(SE)/Ch0- thru Ch31(DIFF)
LM335 + terminal
LM335 – terminal
AGND
TEMP+ (LM335) (CH8+) DAC0 / DAC1 AGND / DAC0 / DAC1 return

I/O Description

I

Channel 0 thru Channel 31 single-ended or Channel 0 thru Channel 31 differential non-inverting input

I

Channel 32 thru Channel 63 single-ended or Channel 0 thru Channel 31 differential inverting input

Temperature sensor + lead for reference junction or cold-junction compensation. When this option is

I

ordered, Channel 1 is factory configured to provide a + bias to a provided LM335 precision temperature sensor, which should be connected to the also provided screw terminal adapter model

UTBK-50.

I

When this option is ordered, connect the ­ lead of the provided LM335 precision temperature sensor to the also provided screw terminal adapter model UTBK-50.

x

Analog Ground, All single-ended AND differential signals must have a ground reference connected on one of these pins.

I

Temperature sensor input circuit (LM335 + lead) when TEMP1 jumper is installed. Connected to channel 8 differential non-inverting input

O Digital to Analog Output 0 / 1

x DAC0 or 1’s ground when installed. Otherwise, Analog Ground

Table 5-3: J1 and J2 Signal Names and Descriptions

DAQ-PACK M Series Modules User Guide 11

www.assured-systems.com | sales@assured-systems.com

Page 11/15

ACCES I/O DPK-AIO/DPK-AI-XX-XXXX Get Quote

Pin Signal Name Pin Signal Name

1 DIO0

14 DIO12

2 DIO1

15 DIO13

3 DIO2

16 DIO14

4 DIO3

17 DIO15

5 DIO4

18 GND

6 DIO5

19 External Trigger

7 DIO6

20 A/D Start Enable

8 DIO7

21 Counter Gate

9 GND

22 Counter Clock

10 DIO8

23 Counter Output

11 DIO9

24 GND

12 DIO10

25 GND

13 DIO11

Table 5-4: J3 Connector Pin Assignments (DB25F)

Signal Name DIO0 ­ DIO15 AGND GND Counter Gate External Trigger A/D Start Enable Counter Clock Counter Output

I/O Description I/O Digital Input and Digital Output lines (SW configurable, pulled-up) x Analog Ground x Ground (power and digital signaling) I External A/D Enable / Counter Gate Input (pulled-up, active-high) I Ext A/D Conversion Start Trigger (pulled-up, SW selectable for rising or falling edge) I External A/D Conversion Start Enable (pulled-up, active-high) I 8254 Counter/Timer Clock Input (pulled-up) O 8254 Counter/Timer Output (pulled-up)

Table 5-5: J3 Signal Names and Descriptions

DAQ-PACK M Series Modules User Guide 12

www.assured-systems.com | sales@assured-systems.com

Page 12/15

ACCES I/O DPK-AIO/DPK-AI-XX-XXXX Get Quote

Chapter 6: Primary Specifications

PRIMARY SPECIFICATIONS (full specs in USB-AIO Series manual)

Analog Inputs

Successive approximation

Resolution

16-bit or 12-bit

Sampling rate

100k – 500ksps, depending on model

Channels

32 differential, or 64 single ended inputs

Uni, Bipolar(±) ranges

100mV, 200mV, 400mV, 500mV, 1V, 2V, 2.5V, 5V, 10V

Uni-, bipolar ranges of 1mV, 5mV, 10mV, 20mV, 50mV

Calibration Hardware

“16-, 12-A” versions Two on-board ref’s + calibrated real-time output

“16-E” version

Two on-board references

“12-xxx” version

Two on-board references

“12-xxxE” version

None

System Calibration

Program provided to calibrate entire system

Accuracy

Uncalibrated

0.094% Full-Scale (FS)

Calibrated(1)

0.0015% FS

Input impedance

1M

A/D Start Sources

Software, Timer, External Start Trigger

(1) For best accuracy, one must calibrate to their own standard.

Analog Outputs Type / Resolution Uni, Bipolar(±) Ranges Conv. / Settling Drive Current

2 Single-ended, 16-bit 5V, 10V (factory installed) 4kHz / 4us typ, 7us max; ¼-¾ scale to ±2LSBs ±25mA per channel

Digital I/O Input volts/current
Output volts/current

16 inputs or outputs in groups of 8 (pulled-up)

Logic low:

0V(min) to 0.8V(max) ±20µA

Logic high:

2V(min) to 5V(max) ±20µA

Logic low:

0V(min) to 0.55V(max) 64mA sink

Logic high:

2V(min) to 5V(max) 32mA source

Counter/Timer Available Counters Input Frequency Counter size Clock

82C54 programmable interval counter CTR0 (CTR1, CTR2 dedicated to A/D starts) 10MHz (max) 16-bit Internal 10MHz or Externally supplied

Environmental Operating Temp. Storage Temp. Humidity

0° to +70°C, optional -40° to +85°C -40° to +105°C 5% to 90% RH, without condensation

Enclosure Dimensions -64

(L x W x H) in inches 4.680 x 3.660 x 2.720

Power Required

+5V at 320mA

DAQ-PACK M Series Modules User Guide 13

www.assured-systems.com | sales@assured-systems.com

Page 13/15

ACCES I/O DPK-AIO/DPK-AI-XX-XXXX Get Quote
Customer Comments
If you experience any problems with this manual or just want to give us some feedback, please email us at: manuals@accesio.com. Please detail any errors you find and include your mailing address so that we can send you any manual updates.

10623 Roselle Street, San Diego CA 92121 Tel. (858)550-9559 FAX (858)550-7322 www.accesio.com

DAQ-PACK M Series Modules User Guide 14

www.assured-systems.com | sales@assured-systems.com

Page 14/15

ACCES I/O DPK-AIO/DPK-AI-XX-XXXX Get Quote
Assured Systems
Assured Systems is a leading technology company with over 1,500 regular clients in 80 countries, deploying over 85,000 systems to a diverse customer base in 12 years of business. We offer high-quality and innovative rugged computing, display, networking and data collection solutions to the embedded, industrial, and digital-out-of-home market sectors.
US
sales@assured-systems.com
Sales: +1 347 719 4508 Support: +1 347 719 4508
1309 Coffeen Ave Ste 1200 Sheridan WY 82801 USA
EMEA
sales@assured-systems.com
Sales: +44 (0)1785 879 050 Support: +44 (0)1785 879 050
Unit A5 Douglas Park Stone Business Park Stone ST15 0YJ United Kingdom
VAT Number: 120 9546 28 Business Registration Number: 07699660

www.assured-systems.com | sales@assured-systems.com

Page 15/15

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

ASSURED User Manuals

Related Manuals