ASSURED SYSTEMS PCI-COM-1S PCI Cards User Manual
- August 8, 2024
- ASSURED SYSTEMS
Table of Contents
- ASSURED SYSTEMS PCI-COM-1S PCI Cards
- Product Information
- Product Usage Instructions
- Warranty
- Introduction
- Specifications
- Installation
- Option Selection
- Address Selection
- Programming
- Connector Pin Assignments
- Application Considerations
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ASSURED SYSTEMS PCI-COM-1S PCI Cards
Product Information
Specifications
- Model: PCI-COM-1S
- Manufacturer: ACCES I/O Products Inc
- Interface: PCI
- Number of Ports: 1
- Compatibility: IBM PC, PC/XT, PC/AT
Product Usage Instructions
-
Installation
Before installing the PCI-COM-1S card, ensure the computer power is turned off. Follow the installation instructions provided in Chapter 2 of the user manual. -
Option Selection
Refer to Chapter 3 for option selection guidelines. Use the Option Selection Map (Figure 3-1) to configure the card based on your requirements. -
Address Selection
Chapter 4 covers address selection details. Follow the instructions to set the appropriate address for the PCI-COM-1S card. -
Programming
For programming the PCI-COM-1S card, refer to Chapter 5 of the user manual. Follow the programming instructions provided to integrate the card into your system effectively.
FAQ
-
Q: Can I install the PCI-COM-1S card with the computer power on?
A: No, it is strongly advised to always connect and disconnect cables and install cards with the computer powered off to prevent damage to the I/O card and voiding of warranties. -
Q: What is the warranty coverage for ACCES equipment?
A: ACCES provides a three-year warranty where defective units/parts will be repaired or replaced at no charge for labor or parts not excluded by warranty. Additional service is available throughout the equipment’s lifetime at reasonable rates.
Notice
The information in this document is provided for reference only. ACCES does
not assume any liability arising out of the application or use of the
information or products described herein. This document may contain or
reference information and products protected by copyrights or patents and does
not convey any license under the patent rights of ACCES, nor the rights of
others.
- IBM PC, PC/XT, and PC/AT are registered trademarks of the International Business Machines Corporation.
- Printed in USA. Copyright 1995, 2005 by ACCES I/O Products Inc, 10623 Roselle Street, San Diego, CA 92121. All rights reserved.
WARNING!
ALWAYS CONNECT AND DISCONNECT YOUR FIELD CABLING WITH THE COMPUTER POWER OFF.
ALWAYS TURN THE COMPUTER POWER OFF BEFORE INSTALLING A CARD. CONNECTING AND
DISCONNECTING CABLES, OR INSTALLING CARDS INTO A SYSTEM WITH THE COMPUTER OR
FIELD POWER ON MAY CAUSE DAMAGE TO THE I/O CARD AND WILL VOID ALL WARRANTIES,
IMPLIED OR EXPRESSED.
Warranty
Prior to shipment, ACCES equipment is thoroughly inspected and tested to applicable specifications. However, should equipment failure occur, ACCES assures its customers that prompt service and support will be available. All equipment originally manufactured by ACCES that is found to be defective will be repaired or replaced subject to the following considerations.
Terms and Conditions
If a unit is suspected of failure, contact ACCES’ Customer Service department.
Be prepared to give the unit model number, serial number, and a description of
the failure symptom(s). We may suggest some simple tests to confirm the
failure. We will assign a Return Material Authorization (RMA) number which
must appear on the outer label of the return package. All units/components
should be properly packed for handling and returned with freight prepaid to
the ACCES designated Service Center and will be returned to the
customer’s/user’s site freight prepaid and invoiced.
Coverage
- First Three Years: Returned unit/part will be repaired and/or replaced at ACCES option with no charge for labor or parts not excluded by warranty. Warranty commences with equipment shipment.
- Following Years: Throughout your equipment’s lifetime, ACCES stands ready to provide on-site or in-plant service at reasonable rates similar to those of other manufacturers in the industry.
Equipment Not Manufactured by ACCES
Equipment provided but not manufactured by ACCES is warranted and will be
repaired according to the terms and conditions of the respective equipment
manufacturer’s warranty.
General
Under this Warranty, the liability of ACCES is limited to replacing,
repairing, or issuing credit (at ACCES discretion) for any products that are
proved to be defective during the warranty period. In no case is ACCES liable
for consequential or special damage arriving from the use or misuse of our
product. The customer is responsible for all charges caused by modifications
or additions to ACCES equipment not approved in writing by ACCES or if, in
ACCES’s opinion, the equipment has been subjected to abnormal use. “Abnormal
use” for purposes of this warranty is defined as any use to which the
equipment is exposed other than that use specified or intended as evidenced by
purchase or sales representation. Other than the above, no other warranty,
expressed or implied, shall apply to any such equipment furnished or sold by
ACCES.
Introduction
This Serial Communications Card was designed for use in PCI-Bus computers and provides effective communication in either RS422 (EIA422) or RS485 (EIA485) over long communication lines. The card is 4.80 inches long (122 mm) and may be installed in any 5-volt PCI slot in IBM or compatible computers. A type 16550 buffered UART is used and, for Windows compatibility, automatic control is included to transparently enable/disable the transmission drivers.
Balanced Mode Operation and Load Termination
- In RS422 mode, the card uses differential (or balanced) line drivers for noise immunity and to increase the maximum distance to 4000 feet. The RS485 mode improves on RS422 with switchable transceivers and the ability to support multiple devices on a single “party line”. The number of devices served on a single line can be expanded by using “repeaters”.
- RS422 operation permits multiple receivers on the communications lines and RS485 operation permits up to 32 transmitters and receivers on the same set of data lines. Devices at the ends of these networks should be terminated to avoid “ringing”. The user has the option to terminate the transmitter and/or the receiver lines.
- RS485 communications require that a transmitter supply a bias voltage to ensure a known “zero” state when no device is transmitting. This card supports biasing by default. If your application requires the transmitter to be unbiased, please contact the factory.
COM Port Compatibility
- A 16550 UART is used as the Asynchronous Communication Element (ACE). It includes 16-byte transmit/receive FIFO buffers to protect against lost data in multitasking operating systems while maintaining 100 percent compatibility with the original IBM serial port. PCI bus architecture allows addresses between 0000 and FFF8 hex to be assigned to the cards.
- The crystal oscillator on the card permits precise selection of baud rates up to 115,200 or, by changing a jumper, up to 460,800 baud with the standard crystal oscillator. Baud rate is program selected and rates available are listed in a table in the Programming section of this manual.
- The driver/receiver used, the 75ALS176, is capable of driving extremely long communication lines at high baud rates. It can drive up to +60 mA on balanced lines and receive inputs as low as 200 mV differential signal superimposed on common mode noise of +12 V or -7 V. In case of communication conflict, the driver/receivers feature a thermal shutdown.
Communication Modes
The cards support Simplex, Half-Duplex, and Full-Duplex communications in a
variety of two and four-wire cable connections. Simplex is the simplest form
of communication with transmission occurring only in one direction. Half-
Duplex allows traffic to travel in both directions, but only one way at a
time. In Full-Duplex operation, data travels in both directions at the same
time. Most RS485 communications use the Half-Duplex mode because only a single
pair of wires need to be used and installation costs are dramatically reduced.
Auto-RTS Transceiver Control
In Windows applications the driver must be enabled and disabled as needed,
allowing all cards to share a two-wire or four-wire cable. This card controls
the driver automatically. With automatic control, the driver is enabled when
data are ready to be transmitted. The driver remains enabled for the
transmission time of one additional character after the data transfer is
complete and then is disabled. The receiver is normally enabled but is
disabled during transmission and then re-enabled after transmission is
completed. The card automatically adjusts its timing to the baud rate of the
data.
Specifications
Communications Interface
- I/O Connection: Shielded male D-sub 9-pin IBM AT style connector compatible with RS422 and RS485 specifications.
- Character length: 5, 6, 7, or 8 bits.
- Parity: Even, odd, or none.
- Stop Interval: 1, 1.5, or 2 bits.
- Serial Data Rates: Up to 115,200 baud, Asynchronous. Faster rates, up to 460,800 baud, are achieved by jumper selection on the card. Type 16550 buffered UART.
RS422/RS485 Differential Communication Mode
- Receiver Input Sensitivity: +200 mV, differential input.
- Common Mode Rejection: +12V to -7V
- Drive Capability: 60 mA transmit output with thermal shutdown.
- Multipoint: Compatible with RS422 and RS485 specifications.
Note
Up to 32 drivers and receivers are allowed online. The serial communications
ACE used is type 16550. Driver/Receivers used are type 75ALS176.
Environmental
- Operating Temperature Range: 0 to +60 °C
- Humidity: 5% to 95%, non-condensing.
- Storage Temperature Range: -50 to +120 °C
- Size: 4.80″ long (122mm) by 1.80″ high (46 mm).
- Power Required: +5VDC at 175 mA typical
Installation
- A printed Quick-Start Guide (QSG) is packed with the card for your convenience. If you’ve already performed the steps from the QSG, you may find this chapter to be redundant and may skip forward to begin developing your application.
- The software provided with this card is on CD and must be installed onto your hard disk prior to use. To do this, perform the following steps as appropriate for your operating system.
Configure Card Options via Jumper Selection
Before installing the card into your computer, carefully read Chapter 3:
Option Selection of this manual, then configure the card according to your
requirements and protocol (RS-232, RS-422, RS-485, 4-wire 485, etc.). Our
Windows-based setup program can be used in conjunction with Chapter 3 to
assist in configuring jumpers on the card, as well as provide additional
descriptions for usage of the various card options (such as termination, bias,
baud rate range, RS-232, RS-422, RS-485, etc.).
CD Software Installation
The following instructions assume the CD-ROM drive is drive “D”. Please
substitute the appropriate drive letter for your system as necessary.
DOS
- Place the CD into your CD-ROM drive.
- Type to change the active drive to the CD-ROM drive.
- Type to run the install program.
- Follow the on-screen prompts to install the software for this board.
WINDOWS
- Place the CD into your CD-ROM drive.
- The system should automatically run the install program. If the install program does not run promptly, click START | RUN and type , click OK, or press .
- Follow the on-screen prompts to install the software for this board.
LINUX
Please refer to linux.htm on the CD-ROM for information on installing under
Linux.
Note:
COM boards can be installed in virtually any operating system. We do support
installation in earlier versions of Windows and are very likely to support
future versions as well.
Caution!
ESD A single static discharge can damage your card and cause premature
failure! Please follow all reasonable precautions to prevent a static
discharge such as grounding yourself by touching any grounded surface before
touching the card.
Hardware Installation
- Make sure to set switches and jumpers from either the Option Selection section of this manual or from the suggestions of SETUP.EXE.
- Do not install the card into the computer until the software has been fully installed.
- Turn OFF computer power AND unplug AC power from the system.
- Remove the computer cover.
- Carefully install the card in an available 5V or 3.3V PCI expansion slot (you may need to remove a backplate first).
- Inspect for proper fit of the card and tighten screws. Make sure that the card mounting bracket is properly screwed into place and that there is a positive chassis ground.
- Install an I/O cable onto the card’s bracket-mounted connector.
- Replace the computer cover and turn ON the computer. Enter the CMOS setup program of your system and verify that the PCI plug-and-play option is set appropriately for your system. Systems running Windows 95/98/2000/XP/2003 (or any other PNP-compliant operating system) should set the CMOS option to OS. Systems running under DOS, Windows NT, Windows 3.1, or any other non-PNP-compliant operating system should set the PNP CMOS option to BIOS or Motherboard. Save the option and continue booting the system.
- Most computers should auto-detect the card (depending on the operating system) and automatically finish installing the drivers.
- Run PCIfind.exe to complete installing the card into the registry (for Windows only) and to determine the assigned resources.
- Run one of the provided sample programs that was copied to the newly created card directory (from the CD) to test and validate your installation.
Option Selection
Four configuration options are determined by jumper position as described in the following paragraphs. Locations of the jumpers are shown in Figure 3-1, Option Selection Map.
422/485
This jumper selects either RS422 or RS485 communications mode.
Termination and Bias
- A transmission line should be terminated at the receiving end in its characteristic impedance to avoid “ringing”. Installing a jumper at the location labeled TERMIN applies a 120Ω load across the input for RS422 mode. Similarly, installing a jumper at the location labeled TERMOUT applies 120Ω across the transmit/receive input/output for RS485 operation.
- In RS485 operations, where there are multiple terminals, only the RS485 ports at each end of the network should have terminating resistors as described above. Also, for RS485 operation, there must be a bias on the RX+ and RX- lines. The 422/485 feature provides this bias.
Baud Rate
The x1/x4 jumper selects either the standard 1.8432MHz clock or the 7.3728MHz
clock for input to the UART. The x4 position provides capability for baud
rates up to 460,800 KHz.
Interrupts
The IRQ number is assigned by the system. Use PCIFind.EXE to determine the IRQ
that was assigned to the card by the BIOS or Operating System. Alternately, in
Windows 95/98/NT the Device Manager can be used. The card is listed under the
Data Acquisition class. Selecting the card, clicking Properties, then
selecting the Resources tab will show the base address and IRQ assigned to the
card.
Address Selection
- The PCI architecture is Plug-and-Play. This means the BIOS or Operating System determines the resources assigned to PCI cards, rather than the user selecting these resources with switches or jumpers.
- As a result, the card’s base address cannot be changed, it can only be determined. It’s possible to use the Windows95/98/NT device manager to specify system resources but that method is beyond the scope of this manual.
- To determine the base address that has been assigned to the card, run the provided PCIFind.EXE utility program. This utility will display a list of all of the cards detected on the PCI bus, the addresses assigned to each function on each of the cards, and the respective IRQs and DMAs (if any) allotted.
- Alternately, some operating systems (Windows 95/98/2000) can be queried to determine which resources were assigned. In these operating systems, you can use either PCIFind or the Device Manager utility from the System Properties Applet of the control panel. These cards are installed in the Data Acquisition class of the Device Manager list. Selecting the card then clicking Properties, then selecting the Resources Tab will display a list of the resources allocated to the card.
- The PCI bus supports a minimum of 64K of I/O space, your card’s address may be located anywhere in the 0400 to FFF8 hex range. PCIFind uses the Vendor ID and the Device ID to search for your card then reads the base address and IRQ assigned. If you want to determine the base address and IRQ assigned, use the following information:
- The Vendor ID code for the card is 494F (ASCII for “IO”).
- The Device ID code for the card is 10C9.
Programming
Sample Programs
There are sample programs provided with the card in C, Pascal, QuickBASIC,
and several Windows languages. DOS samples are located in the DOS directory
and Windows samples are located in the WIN32 directory.
Windows Programming
The card installs into Windows as COM ports. Thus the Windows standard API
functions can be used. In particular:
- CreateFile() and CloseHandle() for opening and closing a port.
- SetupComm(), SetCommTimeouts(), GetCommState(), and SetCommState() to set and change a port’s settings.
- ReadFile() and WriteFile() for accessing a port.
- See the documentation for your chosen language for details.
- Under DOS, the process is very different. The remainder of this chapter describes DOS programming.
Initialization
Initializing the chip requires knowledge of the UART’s register set. The first step is to set the baud rate divisor. You do this by first setting the DLAB (Divisor Latch Access Bit) high. This bit is Bit 7 at Base Address +3. In C code, the call would be:
outport b (BASEADDR +3,0×80);
You then load the divisor into Base Address +0 (low byte) and Base Address +1
(high byte). The following equation defines the relationship between baud rate
and divisor:
- Desired Baud Rate = (UART clock frequency) ÷ (32 * divisor)
When the Baud jumper is in the X1 position, the UART clock frequency is 1.8432 Mhz. When the jumper is in the X4 position, the clock frequency is 7.3728 Mhz. The following table lists popular divisor frequencies. Note that there are two columns to consider depending on the position of the Baud jumper.
Baud Rate| Divisor x1| Divisor x4| Max
Diff. Cable **Length***
---|---|---|---
460800| –| 1| 550 ft
230400| –| 2| 1400 ft
153600| –| 3| 2500 ft
115200| 1| 4| 3000 ft
57600| 2| 8| 4000 ft
38400| 3| 12| 4000 ft
28800| 4| 16| 4000 ft
19200| 6| 24| 4000 ft
14400| 8| 32| 4000 ft
9600| 12| 48 – Most Common| 4000 ft
4800| 24| 96| 4000 ft
2400| 48| 192| 4000 ft
1200| 96| 384| 4000 ft
Recommended maximum distances for differentially driven data cables (RS422 or RS485) are for typical conditions.
Table 5-1: Baud Rate Divisor Values
In C, the code to set the chip to 9600 baud is:
- outport b(BASEADDR, 0x0C);
- outport b(BASEADDR +1,0);
The second initializing step is to set the Line Control Register at Base Address + 3. This register defines word length, stop bits, parity, and the DLAB. Bits 0 and 1 control word length and allow word lengths from 5 to 8 bits. Bit settings are extracted by subtracting 5 from the desired word length. Bit 2 determines the number of stop bits. There can be either one or two stop bits. If Bit 2 is set to 0, there will be one stop bit. If Bit 2 is set to 1, there will be two stop bits. Bits 3 through 6 control parity and break enable. They are not commonly used for communications and should be set to zero. Bit 7 is the DLAB discussed earlier. It must be set to zero after the divisor is loaded or else there will be no communication.
The C command to set the UART for an 8-bit word, no parity, and one stop bit is:
outport b(BASEADDR +3, 0x03)
The final initialization step is to flush the receiver buffers. You do this
with two reads from the receiver buffer at Base Address +0. When done, the
UART is ready to use.
Reception
Reception can be handled in two ways: polling and interrupt-driven. When
polling, reception is accomplished by constantly reading the Line Status
Register at Base Address +5. Bit 0 of this register is set high whenever data
are ready to be read from the chip. A simple polling loop must continuously
check this bit and read in data as it becomes available. The following code
fragment implements a polling loop and uses a value of 13, (ASCII Carriage
Return) as an end-of-transmission marker:
- do
- {
- while (!(inportb(BASEADDR +5) & 1)); /Wait until data ready/data[i++]= inportb(BASEADDR);
- }while (data[i]!=13); /Reads the line until null character rec’d/
Interrupt-driven communications should be used whenever possible and is required for high data rates. Writing an interrupt-driven receiver is not much more complex than writing a polled receiver but care should be taken when installing or removing your interrupt handler to avoid writing the wrong interrupt, disabling the wrong interrupt, or turning interrupts off for too long a period.
The handler would first read the Interrupt Identification Register at Base Address +2. If the interrupt is for Received Data Available, the handler then reads the data. If no interrupt is pending, control exits the routine. A sample handler, written in C, is as follows:
- readback = inport b(BASEADDR +2);
- if (readback & 4) /Readback will be set to 4 if data are available/data[i++]=inportb(BASEADDR);
- outport b(0x20,0x20); /Write EOI to 8259 Interrupt Controller/return;
Transmission
RS485 transmission is simple to implement. The AUTO feature in RS485 mode automatically enables the transmitter when data are ready to send, so no software enabling is required. The following software example is for non-AUTO operation in RS422 mode. First, the RTS line should be set high by writing a 1 to Bit 1 of the Modem Control Register at Base Address +4. The RTS line is used to toggle the transceiver from receive mode to transmit mode and vice versa.
After the above is done, the card is ready to send data. To transmit a string of data, the transmitter must first check Bit 5 of the Line Status Register at Base Address +5. That bit is the transmitter-holding-register-empty flag. If it is high, the transmitter has sent the data. The process of checking the bit until it goes high followed by a write is repeated until no data remains. After all data has been transmitted, the RTS bit should be reset by writing a 0 to Bit 1 of the Modem Control Register.
The following C code fragment demonstrates this process:
-
outport b(BASEADDR +4, inport b(BASEADDR +4)|0x02);
-
/Set RTS bit without altering states of other bits/
-
while(data[i]); /While there is data to send/
{ -
while(!(inportb(BASEADDR +5)&0x20)); /Wait until transmitter is empty/
-
outportb(BASEADDR,data[i]);
i++;
} -
outport b(BASEADDR +4, inport b(BASEADDR +4)&0xFD);
- /Reset RTS bit without altering states of other bits/
Caution
The OUT2 bit of the UART must be set to ‘TRUE’ for proper interrupt-driven
communication. Legacy software uses this bit to gate interrupts and the card
may not communicate if bit 3 of register 4 (Modem Control Register) is not
set.
Connector Pin Assignments
The popular 9-pin D subminiature connector is used for interfacing with communication lines. The connector is equipped with 4-40 threaded standoffs (female screw lock) to provide strain relief.
Pin No. | Assignment |
---|---|
1 | Rx– (Receive Data) |
2 | Tx+ (Transmit Data) |
3 | Tx– (Transmit Data) |
4 | |
5 | GND (Signal Ground) |
6 | |
7 | |
8 | |
9 | Rx+ (Receive Data) |
Table 6-1: Connector Pin Assignments
Data Cable Wiring
The following table shows pin connections between two devices for Simplex,
Half -Duplex and Full- Duplex operations.
Mode | Card 1 | Card 2 |
---|---|---|
Simplex, 2-wire, receive only, RS422 | Rx+ pin 9 | Tx+ pin 2 |
Rx- pin 1 | Tx- pin 3 | |
Simplex, 2-wire, transmit only, RS422 | Tx+ pin 2 | Rx+ pin 9 |
Tx- pin 3 | Rx- pin 1 | |
Half-Duplex, 2-wire, RS485 | Tx+ pin 2 | Tx+ pin 2 |
Tx- pin 3 | Tx- pin 3 | |
Full-Duplex, 4-wire, RS422 | Tx+ pin 2 | Rx+ pin 9 |
Tx- pin 3 | Rx- pin 1 | |
Rx+ pin 9 | Tx+ pin 2 | |
Rx- pin 1 | Tx- pin 3 |
Application Considerations
Introduction
Working with RS422 and RS485 devices is not much different from working
with standard RS232 serial devices and these two standards overcome
deficiencies in the RS232 standard. First, the cable length between two RS232
devices must be short; less than 50 feet. Second, many RS232 errors are the
result of noise-induced by the cables. The RS422 standard permits cable
lengths up to 5000 feet and, because it operates in differential mode, it is
more immune to induced noise.
Connections between two RS422 devices (with CTS ignored) should be as follows:
Device #1 | Device #2 |
---|---|
Signal | 9 pin |
Gnd | 5 |
TX+ | 2 |
TX– | 3 |
RX+ | 9 |
RX– | 1 |
Table A-1: Connections Between Two RS422 Devices
A third deficiency of RS232 is that more than two devices cannot share the same cable. This is also true for RS422 but RS485 offers all the benefits of RS422 plus allows up to 32 devices to share the same twisted pairs. An exception to the foregoing is that multiple RS422 devices can share a single cable if only one will talk and the others will always receive.
Balanced Differential Signals
The reason that RS422 and RS485 devices can drive longer lines with more
noise immunity than RS232 devices is that a balanced differential drive method
is used. In a balanced differential system, the voltage produced by the driver
appears across a pair of wires. A balanced line driver will produce a
differential voltage from +2 to +6 volts across its output terminals. A
balanced line driver can also have an input “enable” signal that connects the
driver to its output terminals. If the “enable” signal is OFF, the driver is
disconnected from the transmission line. This disconnected or disabled
condition is usually referred to as the “tristate” condition and represents a
high impedance. RS485 drivers must have this control capability. RS422 drivers
may have this control but it is not always required.
A balanced differential line receiver senses the voltage state of the transmission line across the two signal input lines. If the differential input voltage is greater than +200 mV, the receiver will provide a specific logic state on its output. If the differential voltage input is less than -200 mV, the receiver will provide the opposite logic state on its output. The maximum operating voltage range is from +6V to -6V allowing for voltage attenuation that can occur on long transmission cables.
A maximum common mode voltage rating of +7V provides good noise immunity from voltages induced on the twisted pair lines. The signal ground line connection is necessary in order to keep the common mode voltage within that range. The circuit may operate without the ground connection but may not be reliable.
Parameter | Conditions | Min. | Max. |
---|---|---|---|
Driver Output Voltage (unloaded) | 4V | 6V | |
-4V | -6V | ||
Driver Output Voltage (loaded) | TERM | 2V | |
jumpers in | -2V | ||
Driver Output Resistance | 50Ω | ||
Driver Output Short-Circuit Current | +150 mA | ||
Driver Output Rise Time | 10% unit interval | ||
Receiver Sensitivity | +200 mV | ||
Receiver Common Mode Voltage Range | +7V | ||
Receiver Input Resistance | 4KΩ |
Table A-2: RS422 Specification Summary
To prevent signal reflections in the cable and to improve noise rejection in both the RS422 and RS485 modes, the receiver end of the cable should be terminated with a resistance equal to the characteristic impedance of the cable.
Note
You do not have to add a terminator resistor to your cables when you use the
card. Termination resistors for the RX+ and RX- lines are provided on the card
and are placed in the circuit when you install the TERM jumpers. (See the
Option Selection section of this manual.)
RS485 Data Transmission
The RS485 Standard allows a balanced transmission line to be shared in a
party-line mode. As many as 32 driver/receiver pairs can share a two-wire
party line network. Many characteristics of the drivers and receivers are the
same as in the RS422 Standard. One difference is that the common mode voltage
limit is extended and is +12V to -7V. Since any driver can be disconnected (or
tristated) from the line, it must withstand this common mode voltage range
while in the tristate condition.
RS485 Two-Wire Multidrop Network
The following illustration shows a typical multidrop or party line network.
Note that the transmission line is terminated on both ends of the line but not
at drop points in the middle of the line.
RS485 Four-Wire Multidrop Network
An RS485 network can also be connected in a four-wire mode. In a four-wire
network, it’s necessary that one node be a master node and all others be
slaves. The network is connected so that the master communicates to all slaves
and all slaves communicate only with the master. This has advantages in
equipment that uses mixed protocol communications. Since the slave nodes never
listen to another slave’s response to the master, a slave node cannot reply
incorrectly.
Customer Comments
If you experience any problems with this manual or just want to give us some
feedback, please email us at:
manuals@accesio.com.. Please detail any errors
you find and include your mailing address so that we can send you any manual
updates.
Assured Systems
Assured Systems is a leading technology company with over 1,500 regular
clients in 80 countries, deploying over 85,000 systems to a diverse customer
base in 12 years of business. We offer high-quality and innovative rugged
computing, display, networking, and data collection solutions to the embedded,
industrial, and digital-out-of-home market sectors.
US
- sales@assured-systems.com
- Sales: +1 347 719 4508
- Support: +1 347 719 4508
- 1309 Coffeen Ave Ste 1200 Sheridan WY 82801 USA
EMEA
- sales@assured-systems.com
- Sales: +44 (0)1785 879 050
- Support: +44 (0)1785 879 050
- Unit A5 Douglas Park Stone Business Park Stone ST15 0YJ United Kingdom
- VAT Number: 120 9546 28
- Business Registration Number: 07699660
www.assured-systems.com | sales@assured- systems.com.
References
- Industrial Embedded Computers and Displays - Assured Systems
- Industrial Embedded Computers and Displays - Assured Systems
- Industrial Embedded Computers and Displays - Assured Systems
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>