weelko 2246EBS Beauty Beds Instruction Manual

August 26, 2024
weelko

weelko 2246EBS Beauty Beds

weelko-2246EBS-Beauty-Beds-PRODUCT

 About This Manual

This manual shall only be used for the reference of operation of this particular model. If the manual
is used for other purposes, SILVERFOX will not undertake any according consequences and responsibility. All information of this manual shall be protected by copyright and shall not be copied and translated in any part of this specification without the written consent of our company SILVERFOX.

Warning

  • Power supply must be cut off when changing electrical components or maintaining and cleaning machines.
  • The plug must be plugged into an outlet that is properly installed and grounded, to prevent the risk of fire and electric shock.
  • Do not stand on this equipment.
  • Do not allow children to play with and place the equipment in a place where children can touch. Please adjust the backrest to the highest position when you leave.
  • Please do not place the equipment in wet places such as bathroom to avoid electric shock or other failure; Also keep the controllers away from water.
  • Please do not place and operate the equipment in places where Is painting/coating or supplying oxygen.
  • Unless being monitored or Instructed by personnel who can be responsible for their personal safety, the people who have physical obstacles, tactile disorders, mental disorders, lack of experience, common sense or children, are not allowed to use the equipment.
  • Please contact distributor, service center or related personal with appropriate skill and experience for repairing if the plug is damaged, in case of any danger.
  • Please make sure there is no accessible thing within the stroke during any operation of the chairs.
  • Operation should be processed by trained professionals.
  • The ME EQUIPMENT that are not serviced or maintained while in use with the patient.
  • Do not use the device near electromagnetic transmitters.
  • Read and follow the “information about Electromagnetic compatibility (EMC).
  • Instructions provided indicating not to position ME EQUIPMENT to make it difficult to operate the disconnetion device.
  • The third conductor in the POWER SUPPLY CORD is only afunctional earth.
  • The maximum load of this chair is 175kg. There are safety risks associated with being overweight.
  • If the user/patient is aware of any serious incident related to the device, they shall report it to the competent authority and manufacturer of the user and/or the patient’s member state.
  • No contraindications at present.
  • To avoid the risk of electric shoe!\, this equipment must only be connected to a supply mains with protective earth.
  • The device and accessories are to be disposed of according to local regulations after their service lives. Alternatively, they can be returned to the dealer or che manufacturer for recycling or proper disposal.
  • No modification of this equipment is allowed.
  • Do not touch the Signal 1/0 ports if in contact with the patient, otherwise patient injury may result.
  • This product can only be operated by medical practitioners with professional qualifications, and patients should not operate by themselves.

Precautions

  • The equipment should be used by an experienced person who must be Familiar with the product structure. performance and instructions. And make the regular maintenance work.
  • Read this manual carefully before Installation, operation and adjustment. And please keep it well.
  • This product shall not be used for single side or single point loading work.
  • Comply with safety operation rules, do not overload the use of products, to ensure that the product safety protection equipment is complete and reliable, eliminates unsafe factors on time.
  • Tighten bolts and nuts regularly to avoid failure caused by loose, sliding, vibration and falling parts.
  • During the maintenance, the operator shall not disassemble any parts of the chair at will.
  • This product is not allowed to operate when it’s with fault. If abnormal phenomenon or abnormal sound Is found, It must be stopped for Inspection immediately, and work can be resumed after troubleshooting.
  • The operator must be familiar with the precautions descrichair in each section of the manual to ensure the safety of person and product.
  • This electric beauty chair is equipped with a three-wire power cord. The power cord must be plugged into a three-hole outlet which is properly installed and grounded. This is not only co prevent the risk of electric shock. but also ensure chair work properly.
  • Please operate the equipment strict accordance with the warning label pasted to the products.
  • While controlling the lifting of the whole chair, the button must be pressed continuously until the chair in a suitable position.
  • Replacement must be carried out by trained professionals. Our company can provide circuit diagrams, troubleshooting guidelines, or other materials that are helpful for maintenance to professional maintenance personnel
  • Please pay attention that the continuous working times should be Max. 2Min. ON; 1 BMln. OFF, when operating the motor.
  • Protection against electric shock: Class I
  • Maintenance should be processed by trained professionals.
  • After each treatment, please use neutral reagent to clear the dust, stains on leather.
  • When adjusting each part, please keep your hands, feet and head away from the position indicated by the arrow. (As shown in the photo)

Applicable Range

This product is suitable to be used in medical institutions, nursing homes and rehabilitation centers. This product is used for multi-position support operation of patients in medical procedures such as examination or day treatment by medical staff in the clinic.

 Installation

  1. Put the product to a proper location, according to the overall layout, the daylighting or artificial lightings and operation condition of the salon’s or the home. And keep it in the clean, dry and cool environment.

  2. Open the packing carton to check if the product is intact and whether the accessories or spares are complete. Please contact distributor or us if there’s any problem.

  3. Installation
    Place the product to the proper position. Please note that It is unnecessary to install extra screw on the floor to fasten the chair, because the original design has taken the stability into consideration.
    But please ensure the product is placed on a firm and flat ground, so as to prevent any accident. If the product rotates or slant due to rough ground, please adjust the four pieces of plastic feet (M10x30) and nuts (M10) by hexagon open-end wrench, which are fasten on the bottom panel. so as to ensure the product is stable.

  4. Connect the plug of product with power supply properly. (As shown in the photo)

  5. Installation for foot support of 2246EBweelko-2246EBS-Beauty-Beds- \(4\)

  6.  hexagan socket countersunk head screws.

  7. guide ways of foot support.

  8. Bushing.

  9. spring washer.

  10. . Please note the installation location as the picture shown 1 2 3 4. 3).

  11. Installation and fixing A firscly then B.

  12. Installation guide ways of foot support on both side.

Structure of products

  1. angle adjustment of the backrest
  2. lifting actuator
  3. stirrups
  4. angle adjustment of the seat
  5. angle adjustment of the footrest

Operation Instruction

Standard Configuration (Button Panel) weelko-2246EBS-Beauty-Beds-
\(6\) weelko-2246EBS-Beauty-Beds- \(7\)

  1. Standard Configuration (Built-In Foot Controller)
  2. Optional Configuration (Hand Controller)
  3. Optional Configuration (Hand Controller)weelko-2246EBS-Beauty-Beds- \(8\) weelko-2246EBS-Beauty-Beds- \(9\) weelko-2246EBS-Beauty-Beds- \(10\)

Notes

  1. The memory position setting is only available for the models with memory function.
  2. The heating function is only available for the models with heating function.
  3. Different hand controllers should be chosen according to different configuration.

Operation Cautions

  • If you find the headrest support rod became loose, please follow the above steps to fix it.
  • Not allowed to operate seat cushion to tilt when chair is at lowest position.
  • The position of sliding guide is forbidden to be used for handling assistance.so as not to fracture

weelko-2246EBS-Beauty-Beds- \(11\)

This product graphic is only for display, the specific product structure please refer to the actual product.

Emergency Switch
Allows the operator co Immediately stop the bed in case of an unexpected situation

Instruction for Tightening the Braking Block
(This it to tighten the broking block which tho geor Is rroyod.) weelko-
2246EBS-Beauty-Beds- \(13\)

Instruction for Replacing Braking Block
(This is  collect ii the gear block is absolute,’ywom  and It  work any more,) weelko-2246EBS-Beauty-Beds- \(14\)

This product graphic is only for display, the specific product structure please refer to the actual product.

Technical Parameters

weelko-2246EBS-Beauty-Beds- \(15\)

The maximum load capacity of this chair is 175kg.
There are safety risks associated with being overweight.
weelko-2246EBS-Beauty-Beds- \(16\)

Maintenance

  1. After every treatment, please only use a neutral solution to clear the dust, and stains on leather, metal part or other parts. Disinfecting solutions like alcohol, acid or alkaline solution are forbidden.
    This is to prevent the lifetime of the components from being shortened.

  2. Please lubricate the moving parts regularly (once a year)

Circuit System Connection Diagram

weelko-2246EBS-Beauty-Beds- \(17\)

Troubleshooting

weelko-2246EBS-Beauty-Beds- \(18\)

If problem is still not solved after above operations, please contact maintenance center or supplier to solve it.

Disposal
Contact its local authorities to determine the proper method of disposal.

 Symbols explanation

weelko-2246EBS-Beauty-Beds- \(19\)

EMC Guidance

  • Warning: Don’t use near active HF surgical equipment and the RF shielded room of an ME system  for magnetic resonance imaging, where the intensity of EM disturbances is high.
  • Warning: Use of this equipment adjacent to or stacked with other equipment should be avoided  because it could result in improper operation. If such use is necessary, this equipment  and the other equipment should be observed to verify that they are operating normally. Warning: Use of accessories, transducers. and cables other than those specified or provided by the manufacturer of  this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.
  • Warning: Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 12 in (30 cm) to any part of the equipment, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment could result.

weelko-2246EBS-Beauty-Beds- \(20\) weelko-2246EBS-
Beauty-Beds- \(21\) weelko-2246EBS-Beauty-Beds-
\(22\)

SILVERFOX CORPORATION LIMITED
Address: No.18, 1st Tongle Road,TangXia Town, PengJiang District,Jiangmen City,
Guangdong Province.China
Sales Tel: +86 750-2633320 2633816, +86 20-87514019
After-sales Tel: 020-87514052
E-mail: medical@silverfox.cn
Website: sliverfox.cn

Lotus NL 8.V.
Koninginjulianaple,n 10, le Verd, 2595M The Hague. The Netherlands.
Tel: +31644168999 E-mail: peter@lotusnl.com

  • Do not dispose of old or defective appliances in domestic garbage; this should only be done through public collection points.

  • Please check the product specification before use. This manual is for reference only. Specifications are subject to change without prior notice.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals