PACKAGE CONTENTS

  • These components are subject to change without prior notice.
  • The appearance of the product may differ from the image.

FRONT PANEL

INSTRUCTIONS OF USE

  1.  Connect the power supply via the rear panel.
  2.  Connect the accessories properly in the lateral panel.
  3.  Select the proper glass electrode pipe and insert the metal cap end into the output mouthpiece of the handle (try not to touch the glass electrode with your hands or any metal objects).
    • a. Mushroom-shaped electrode pipe: used for large areas of skin (face, forehead, neck, etc).
    • b. Ladle-shaped electrode pipe: used for medium areas of skin (chin, etc).
    • c. Ball-like electrode pipe: used for small areas of skin (nose, etc).
    • d. Straight electrode pipe: used for indirect treatment.
  4.  Switch the unit on by pressing the “POWER” button and make sure the “ENERGY” is set to the minimum.
  5.  Select the desired treatment time by adjusting “TIME”.
  6.  Press the “START/PAUSE” button to start the treatment.
  7.  Make sure you put your index finger on the glass electrode before you touch the client’s skin. Afterwards touch the treatment area with the glass electrode. You can then slowly adjust the output using “ENERGY”.
  8.  During the course of the treatment, when changing electrodes you should return the output to the minimum level before swapping the electrodes, and then slowly adjust the energy level and return in to the appropriate intensity required.
  9.  At the end of the treatment, slowly reduce the “ENERGY” level to the minimum output and then switch the “POWER” button off before removing the electrode from the customer’s face.

INDIRECT USAGE

  1.  Select the straight glass electrode and insert the metal cap end into the output mouthpiece of the handle.
  2.  Give the handset to the customer, making sure they hold the glass electrode and not the handset.
  3.  Switch on the unit by pressing the “POWER” button and make sure the “ENERGY” is set to the minimum.
  4.  Select the desired treatment time by adjusting “TIME”.
  5.  Press the “START/STOP” button to start the treatment.
  6.  Slowly adjust the output using “ENERGY”.
  7.  Carry out the facial massage or treatment using the prescribed product as required. During the whole treatment process, make sure you do not touch or come into contact with the glass electrode being held by the customer.
  8.  At the end of the treatment, slowly reduce the “ENERGY” level to the minimum output and then switch the “POWER” button off.

CAUTIONS

  • The glass electrode pole will sparkle when it is still less than one inch away from the skin with the instrument switched on. In this case, reduce the energy of the high frequency unit. If the customer still feels the sparkle, they may cover their face with a small, dry cotton towel but never with a nylon or synthetic one.
  • Before removing the glass electrode from the skin, decrease the “ENERGY” to its minimum setting, then switch the power off before removing it from the skin.
  • Customers should not be allowed to wear any metal objects or jewelry; all items must be removed prior to beginning any treatment.
  • High-frequency treatments should not be carried out on pregnant women, or any persons using a pace-maker (or any electrical or rhythmic heart-regulating device).
  • The products used with the high-frequency treatment must not contain any alcohol or spirit-based substances in order to prevent accidental combustion from arcing.
  • Never touch the inner eye (eyeball) area with any high-frequency electrode.
  • Only hold the handle of the high-frequency handset.

MAINTENANCE

  • Glass electrode pipes must be kept clean and dry, and should be sterilized before or after each use.

ACCESSORIES

  • 10009 ELECTRODE 1
  • 10010 ELECTRODE 2
  • 10011 ELECTRODE 3
  • 10012 ELECTRODE 4
  • 10024 SPECIAL ELECTRODE 1
  • 10025 SPECIAL ELECTRODE 2
  • 10026 SPECIAL ELECTRODE 3
  • 10040 HIGH-FREQUENCY HANDLE

TECHNICAL SHEET

weelko F314A Electronic Beauty Instruments-12

WARNING

  • Never under any circumstances attempt to open or inspect the internal components or accessories of the machine. If an inspection becomes necessary, please contact your supplier or a suitably competent technician.
  • Never use the unit in humid or poorly ventilated environments, such as wet rooms, bathrooms etc. to prevent damage to the electrical components of your unit.
  • Never use the unit outdoors; exposure to the elements can cause damage.
  • If the power cord was destroyed, please ask a professional to service and replace it to avoid hazards, or contact the dealer for service.

EC-DECLARATION OF COMPLIANCE

This product meets the following requirements:

  1.  Conditions set out in the Low Voltage Directive: 2014/35/EU.
  2.  Conditions set out in the Electromagnetic Compatibility Directive: 2014/30/EU.

RECYCLING
Whenever any of our electrical products or their presentation packaging bear this symbol, it means that these products should not be treated as conventional household waste in Europe. To ensure proper treatment of this waste, dispose of it in accordance with local laws or as required for the disposal of electrical equipment. This initiative will help preserve save natural resources and improve standards of environmental protection in regard to the treatment of electrical waste.

© 2019 Weelko
Visit our website at www.weelko.com for more information
Importer : Weelko Barcelona, S.L

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals