ARGOS Cone 2L Bar EVE Ceiling Pendent Bar Light Brass Instruction Manual
- August 24, 2024
- Argos
Table of Contents
ARGOS Cone 2L Bar EVE Ceiling Pendent Bar Light Brass
Specifications
- Product Name: Cone 2L Bar
- Model Number: 3371688
- Dimensions: Width-83.0cm, Depth-30.0cm, Height-62.0cm
FAQs
- Q: Can I use incandescent bulbs instead of LED bulbs for replacement?
- A: No, only LED bulbs are compatible with this fitting for bulb replacement.
Dimensions
- Width- 83.0cm
- Depth- 30.0cm
- Height- 62.0cm
For household and indoor use only Please read and retain these instructions for future reference
IMPORTANT SAFETY INSTRUCTIONS
- For your safety, this product must be installed according to wiring regulations from the Institute of Engineering and Technology (IET) and current local Building Regulations.
- If in any doubt, or where required by the law, consult a competent person who is registered with an electrical self-certification scheme. Further information is available online or from your Local Authority.
- To prevent electrocution, switch off the mains supply before installing or maintaining this fitting.
- Ensure other persons cannot restore the electricity, supply without your knowledge.
- To avoid damage to concealed wiring during installation, establish the direction of the supply cable before drilling holes.
- Always be sure to use the correct type and wattage of bulbs as indicated on the fitting. Never exceed the wattage stated.
- When changing the bulb, always switch off at the mains and allow the old bulb to cool down before handling. Dispose of used bulbs carefully.
- This fitting is a Class II appliance. It should be fitted to a lighting supply protected by a 5 amp fuse or equivalent breaker. The input supply cord must be double-insulated.
- The luminaire is designed for indoor use only.
- Not suitable for use with a dimmer switch.
Instruction for use
- The drop is adjustable before electrical installation:
- a. Thread the cable through the stem(s) and screw the stem to the bar, add stem(s) until the desired drop is achieved (Total 3 stems, at least 1 stem is used) (Fig.1)
- b. Thread the cable through the canopy, screw the canopy to the stem, and pull any excess cable into the canopy void (Fig.2)
- c. Attach the cable’s live (L) and neutral (N) to the product side L/N port of the terminal box (without sleeve side) and ensure no live and neutral inner cable is left out of the terminal box (Fig.5)
- Switch off the electricity supply at the fuse board.
- Remove the mounting bracket from the fitting by removing the 2 screws. (Fig. 3)
- Using the mounting bracket as a template, mark, and drill fixing holes in the ceiling. Ensure the holes are drilled into a joist or other suitable mounting surface and not just into plaster.
- Attach the mounting bracket to the ceiling using suitable fixings. (Fig. 3)
- The input supply cord of life (L) and neutral (N) need to be fully covered by the small sleeving (provided) and fastened by the plastic belt (provided) to make sure the small sleeving is fixed well on the cables (Fig. 4)
- Ensure the electrical connections are covered with suitable insulation tape.
- The weight of the fitting must be supported whilst making the electrical connections as follows: (Fig 3)
- a. Connect supply live (normally brown or red) to fitting live (marked “L”) on the terminal block.
- b. Connect supply neutral (normally blue or black) to fitting neutral (marked “N”) on the terminal block.
- Note: Ensure electrical connections are tight and no loose strands of wire are left out of the terminal block.
- Place the fitting onto the mounting bracket and push any excess cable into the canopy void. Secure the fitting into position using the 2 screws removed earlier. Take care not to trap or damage wiring.
- Fit the lampshade. (Fig. 6)
- Fit the bulb: Type and wattage as indicated on the fitting. The wattage indicated must not be exceeded.
- Switch on the electricity supply at the fuse board.
Maintenance
This fitting is designed for internal use only and must be fitted to a DRY SURFACE as any dampness in plaster or paint can damage the finish. Do not use polish or abrasive cleaner-just a soft dry cloth.
Bulb Replacement
- Switch off the mains power supply.
- Before replacing the bulb, allow it to cool down for at least 10 minutes.
- Never touch the bulb with your fingers directly, cover it with a cloth.
- Loosen the bulb and remove it from the lamp.
- Replace a new bulb with the same voltage and wattage (Max.8W E27 LED bulb).
- Only compatible with LED bulbs.
Wall Mounting & Fixings
A Guide to: Wall Mounting & Fixings
IMPORTANT: When drilling into walls always check that there are no hidden wires or pipes etc. Make sure that the screws and wall plugs being used are suitable for supporting your unit. Consult a qualified tradesperson if you are unsure.
HINTS:
- General Rule Always use a larger screw and wall plug if you are not sure.
- Ensure you use the recommended drill bit to match the wall plug and hole size.
- Ensure you drill the hole horizontally, do not force the drill or enlarge the hole.
- Take extra care when drilling high walls, ceilings, and ceramic tiles. Ensure the plug is fitting below the ceramic tile to avoid splitting or cracking.
- Ensure wall plugs are well fitted and are a tight fit in the drilled hole.
Types Of Walls
You can use one of the following types of wall plugs if your walls are made of brick, breeze block, concrete, stone, wood, or plasterboard.
- No.1 “Standard” Wall Plug General Wall Materials
- These come in various sizes and are made from plastic or sometimes wood fiber.
- No.2 “General Purpose” Wall Plug Aerated / Breeze Block
- Generally, aerated blocks should not be used to support heavy loads, use a specialist fitting in this case.
- For light loads, a General Purpose Plug can be used.
- No.3 “Shield Anchor” Wall Plug Heavy Loads
- For use with heavier loads such as TV & HiFi Speakers and Satellite Dishes etc.
- No.4 “Cavity Fixing” Wall Plug
- For use with plasterboard partitions or hollow wooden doors.
- No.5 “Cavity Fixing – Heavy Duty” Wall Plug
- For use when fitting or supporting heavy loads such as shelving, wall cabinets, and coat racks.
- No.6 “Hammer Fixing” Wall Plug
- For use with walls stuck with plasterboard.
- The hammer fixing allows it to be fixed to the wall rather than the plaster board.
- Always check the fixing is secure to the retaining wall.
CARE & MAINTENANCE
- SAFETY Always check the fitting and location to ensure your safety in and around the home.
- FITTING From time to time check the fitting to ensure the wall plugs or screws do not become loose.
Recycling electrical products
- You should now recycle your waste electrical goods and in doing so help the environment.
- This symbol means an electrical product should not be disposed of with normal household waste.
- Please ensure it is taken to a suitable facility for disposal.
- Visit www.recycle-more.co.uk, click on “bank locator” and enter your postcode to find your nearest recycling site.
- We care about our quality and what you think, If you have any comments, good or bad, Please call our Careline0345 640 2020
- Or visit Habitat.co.uk
- Your statutory rights are not affected.
- Made in China for Habitat, Argos Limited, London,
- EC1N 2HT, UK. Argos (N.I.) Ltd,
- Forestside Shopping Centre,
- Upper Galwally, Belfast, BT8 6FX, UK.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>