FEIT ELECTRIC 8000 Lumens Commercial Single Head LED Flood Light User Guide
- August 25, 2024
- Feit Electric
Table of Contents
- FEIT ELECTRIC 8000 Lumens Commercial Single Head LED Flood Light User
- Safety Information
- Care and Maintenance
- Limited Warranty
- Pre-Installation
- Installation Preparation
- J-Box or Post Mount Installation
- Wiring for a Standard Wall Switch
- Wiring for 0-10V Dimmer
- Troubleshooting
- Operation
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
FEIT ELECTRIC 8000 Lumens Commercial Single Head LED Flood Light User
Guide
Model #S8.6FL/5CCT/LSDD/BZ
DUSK TO DAWN OPERATION
READ BEFORE INSTALLATION
SAVE THESE INSTRUCTIONS
Questions, problems, missing parts? Before returning to the store, call Feit
Electric Customer Service
8 a.m. – 5 p.m., PST, Monday – Friday
1-866-326-BULB (2852)
FEIT.COM
THANK YOU
We appreciate the trust and confidence you have placed in Feit Electric
through the purchase of this LED yard light fixture.
We strive to continually create quality products designed to enhance your
home. Visit us online to see our full line of products available for your home
improvement needs. Thank you for choosing Feit Electric!
DUSK TO DAWN OPERATION:
The light will turn on at dusk and remain on through the night until dawn.
The light will remain off throughout the day, until dusk.
NOTICE: To make sure this function works properly, always keep the wall switch
in the “ON” position (including daytime).
NOTICE: A sensor cover (DD) is provided which can be used to block out light
and bypass the sensor. This will keep the light continuous on and fixture can
be controlled to turn on/off through the wall switch or a master photocell.
Safety Information
For your safety, always remember to:
- Turn off the power supply at the fuse or circuit breaker box before you install the fixture.
- Ground the fixture to avoid potential electric shock and to ensure reliable starting.
- Double-check all connections to be sure they are tight and correct.
- Wear rubber soled shoes and work on a sturdy wooden ladder.
- Account for small parts and destroy packing material, as these may be hazardous to children.
This fixture is designed for use in a circuit protected by a fuse or circuit
breaker. It is also designed to be installed in accordance with local
electrical codes. If you are unsure about your wiring, consult a qualified
electrician or local electrical inspector, and check your local electrical
code.
Account for small parts and destroy packing material, as these may be
hazardous to children.
Product Specifications:
- 120/277 VAC, 50/60Hz, 80W max
- Suitable for wet locations
- Dimmable with 0-10V dimmers only
- Suitable for mounting within 4 ft. (1.2 m) of the ground
NOTICE: All electrical connections must be in accordance with local and
National
Electrical Code (N.E.C.) standards. If you are unfamiliar with proper
electrical wiring connections obtain the services of a qualified electrician.
Remove the fixture and the mounting package from the box and make sure that no parts are missing by referencing the illustrations on the installation instructions.
Supplier’s Declaration of Conformity:
47 CFR § 2.1077 Compliance Information
Responsible Party:
Feit Electric Company
4901 Gregg Road,
Pico Rivera, CA 90660, USA
562-463-2852
Unique Identifier:
S8.6FL/5CCT/LSDD/BZ
FCC STATEMENT: This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
Care and Maintenance
Periodically clean the fixture and diffuser using a mild, non-abrasive cleaner and soft cloth. When cleaning the fixture, make sure the power is turned off. Do not spray cleaner directly onto any part of the fixture or LEDs.
Limited Warranty
This product is warrantied to be free from defects in workmanship and materials for up to 5 years from date of purchase. If the product fails within the warranty period, please contact Feit Electric at info@feit.com, visit feit.com/contact-us or call 1-866-326-BULB (2852) for instructions on replacement or refund. REPLACEMENT OR REFUND IS YOUR SOLE REMEDY. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW, ANY IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IS HEREBY EXPRESSLY EXCLUDED. Some states and provinces do not allow the exclusion of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state or province to province.
Pre-Installation
TOOLS REQUIRED (NOT INCLUDED)
PACKAGE CONTENTS
Installation Preparation
The fixture must be mounted using the Swivel Knuckle into a domed cover plate (not provided) on a junction box or via a landscape post (sold separately).
J-Box or Post Mount Installation
Wiring for a Standard Wall Switch
Wiring for 0-10V Dimmer
Troubleshooting
Operation
FEIT ELECTRIC COMPANY I PICO RIVERA, CA | 800-543-3348 | FAX 562-908-6360 | www.feit.com
Read More About This Manual & Download PDF:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>