beamZ Pro BTK200C Fresnel Zoom Toneelspot 200W LED Warm User Manual

August 24, 2024
beamz Pro

beamZ-Pro-Logo

beamZ Pro BTK200C Fresnel Zoom Stage Spot 200W LED Warm

beamZ-Pro-BTK200C-Fresnel-Zoom-Stage-Spot-200W-LED-Warm-
Product

Product Information

Product Specifications:

  • Model: BTK200C
  • Version: 155.108 V1.0
  • Power Requirements: Check mains voltage and frequency before connecting
  • DMX Compatibility: Standard DMX controller
  • Fuse Type: Replaceable, same type and value

Product Usage Instructions

Setup and Installation:

  1. Read the instruction manual carefully before proceeding with any operations.
  2. Ensure mains voltage and frequency match the values ​​specified on the equipment.
  3. If using a DMX controller, connect the DMX output to the DMX input of the first fixture in the chain.
  4. Connect subsequent fixtures by linking the output of one unit to the input of the next fixture until all are connected.

Maintenance and Troubleshooting:

  1. If the power cord or fuse is defective, replace it with the appropriate type and value.
  2. For fuse replacement, unplug the mains lead, open the fuse holder, remove the old fuse, install the new fuse, and close the holder.
  3. If exposed to drastic temperature changes, allow the device to reach room temperature before switching it on to prevent damage.

Safety Guidelines:

  • Always connect the device to a protected circuit with appropriate electrical grounding to avoid risks of electrocution or fire.
  • Comply with European and national guidelines for installation and safety issues.
  • Ensure proper disposal of the product at recycling facilities to minimize environmental impact.

Frequently Asked Questions

Q: What should I do if my power cord does not fit my wall outlet?

A: Contact your electrician for assistance in finding a suitable solution for connecting the equipment safely.

Q: How do I properly dispose of this product?

A: Follow local regulations for recycling electronic equipment or contact your Civic Office for guidance on proper disposal methods.

Q: What should I do if I encounter issues with DMX connectivity?

A: Ensure proper connection between fixtures in the DMX chain and use terminating resistors as instructed in the manual for optimal performance.

SAFETY INSTRUCTION

  • WARNING! Before carrying out any operations with the unit, carefully read this instruction manual and keep it with care for future reference. It contains important information about the installation, usage, and maintenance of the unit.
    • Unpack and check carefully that there is no transportation damage before using the unit
    • Please read these instructions carefully and follow the instructions.
    • Observe all safety warnings. Never remove safety warnings or other information from the equipment.
    • Be sure that no ventilation slots are blocked; otherwise, the unit will overheat.
  • CAUTION: Before connecting the equipment to the power outlet, first verify that the mains voltage and frequency match the values specified on the equipment. If the equipment has a voltage selection switch, connect the equipment to the power outlet only if the equipment values and the main power values match. If the included power cord or power adapter does not fit in your wall outlet, contact your electrician.
    • After connecting the unit, check all cables to prevent damage or accidents, e.g., due to tripping hazards.
    • Make sure that the power cord is never crimped or damaged. Check the device and the power cord from time to time.
    • Always disconnect power from the mains, when the device is not used or before cleaning! Only handle the power cord by the plug. Never pull out the plug by tugging the power cord.
    • Unplug the power cord and power adapter from the power outlet if there is a risk of a lightning strike or before extended periods of disuse.
    • Do not switch the unit on and off in short intervals.
    • Do not connect the unit to a dimmer pack.
    • Install the unit in a well-ventilated place.
    • Never place any material over the lens.
    • Always allow free air space of at least 50 cm around the unit for ventilation.
    • Make sure that the area below the installation place is blocked when rigging, de-rigging, or servicing the fixture.
    • For mounting height >100 cm, always fix the fixture with an appropriate safety rope. Fix the safety rope at the correct fixation points only. The safety rope must never be fixed at the transport handles!
    • Never look directly at the light beam. Please note that fast changes in lighting, e. g. flashing light, may trigger epileptic seizures in photosensitive persons or persons with epilepsy.
    • This unit is not designed for permanent operation. Consistent operation breaks will ensure that the device will serve you for a long time without defects.
  • CAUTION: If the power cord of the device is equipped with an earthing contact, then it must be connected to an outlet with a protective ground. Never deactivate the protective ground of a power cord.
    • Make sure that the unit is not exposed to extreme heat, moisture, or dust.
    • Clean the unit using a dry cloth.
    • Do not touch the fixture bare-handed during its operation (housing becomes very hot). Allow the fixture to cool for at least 5 minutes before handling.
    • This unit is designed exclusively for indoor use, do not use this equipment near fluid (does not apply to special outdoor equipment – in this case, observe the special instructions noted below). Do not expose this unit to flammable materials, fluids, or gases.
    • If the unit has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The rising condensation water might damage your unit. Leave the unit switched off until it has reached room temperature.
    • Never attempt to bypass the thermostatic switch or fuses.
    • Do not dismantle or modify the unit.
    • For replacement use fuses/bulbs of the same type and rating only.
    • Repairs, servicing, and electric connection must be carried out by a qualified technician.
    • The ambient temperature must always be between -5° C and +45° C.
    • If this unit is operated in any other way, than the one described in this manual, the product may suffer damages and the warranty becomes void.
    • Plastic bags must be kept out of reach of children.
    • The unit must be installed out of the reach of children. Never leave the unit running unattended.
    • This symbol on the product or its packaging indicates that this product shall not be treated as household waste. Instead, it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.

By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of the product. The recycling of materials will help to conserve natural resources. For more detailed information about recycling this product, please contact your local Civic Office, your household waste disposal service, or the shop where you purchased the product.

UNPACKING INSTRUCTION

CAUTION!
Immediately upon receiving the product, carefully unpack the carton, and check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain the packing material for inspection if any parts appear damaged from shipping or the package itself shows signs of mishandling. Save the package and all packing materials. If the product must be returned to the factory, the product must be returned in the original factory box and packing.

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The rising condensation water might damage your device. Leave the device switched off until it has reached room temperature.

POWERSUPPLY

The label on the backside of the product indicates that this type of power supply must be connected. Check that the mains voltage corresponds to this, all other voltages than specified, the light effect can be irreparably damaged. The product must also be directly connected to the mains and may be used. No dimmer or adjustable power supply.

  • Always connect the device to a protected circuit (circuit breaker or fuse). Make sure the device has an appropriate electrical ground to avoid the risk of electrocution or fire.

RIGGING

The fixture may be set up on a stable and even surface. Employing the fixing facilities of the baseplate, the unit can also be mounted upside down to a truss, see the below picture. For fixing, certified clamps with the correct save working load are required. According to the figure, the quick lock bolts of the omega brackets are placed into the openings provided in the base plate and turned clockwise until they lock (to the stop). The mounting place must be of sufficient stability and be able to support a weight of 10 times the unit’s weight. Secure the fixture with a safety cable so that it cannot fall.

When carrying out any installation, always comply with European and national guidelines concerning rigging, truss, and all other safety issues. Always let the installation be checked out by an authorized dealer!

beamZ-Pro-BTK200C-Fresnel-Zoom-Stage-Spot-200W-LED-Warm-Fig-
\(1\)

DMX512 CONTROL

If you are using a standard DMX controller, you can connect the DMX output of the controller directly to the DMX input of the first fixture in a DMX chain. Always connect the output of one unit with the input of the next fixture until all fixtures are connected.

beamZ-Pro-BTK200C-Fresnel-Zoom-Stage-Spot-200W-LED-Warm-Fig-
\(2\)

Caution:
At the last fixture, you must close the DMX line with a terminating resistor. Take an XLR connector and solder a 120 Ohm resistor between signal (-) and signal (+) and connect it to the DMX output of the last fixture in the line.

beamZ-Pro-BTK200C-Fresnel-Zoom-Stage-Spot-200W-LED-Warm-Fig-
\(3\)

CLEANING

  • The buildup of dust, dirt and other airborne particles will reduce the fixture’s light output. It will also prevent the fixture from cooling correctly, and this will reduce the fixture’s lifetime. The rate of dirt buildup will vary depending on environmental factors such as airborne dust, use of smoke machines, airflow from ventilation systems, etc. The fixture’s cooling fans will accelerate buildup, and any smoke particles that are present in the atmosphere will increase the tendency for dirt to clog.
  • To get the best performance and lifetime from the fixture, inspect it regularly and clean it as soon as you see signs of dirt buildup.
  • Assess the operating environment each time you begin to use the fixture. In dusty or smoky conditions, inspect the fixture after a few hours and check it frequently the fixture may attract dirt faster than you expect. Draw up a cleaning schedule that will make sure that dirt is removed before it can build up.

Use the following guidelines:

  • Disconnect the fixture from power and allow it to cool completely before cleaning.
  • Do not use solvents, abrasives or any other aggressive product to clean the fixture.
  • Vacuum or use low-pressure compressed air to remove dust and loose particles from surfaces and air vents. Prevent the blades of cooling fans from turning before you aim a vacuum or air jet at the fan, or you may spin the fan too fast and damage it.
  • Clean glass components by wiping gently with a soft, clean, lint-free cloth moistened with a weak detergent solution. Put the solution on the cloth and not on the surface to be cleaned. Avoid rubbing glass surfaces.
  • Dry the fixture with a soft, clean, lint-free cloth or low-pressure compressed air before reapplying power.

REPLACING THE FUSE.

If the fuse is defective, replace the fuse with a fuse of the same type and value. Before replacing the fuse, unplug the main lead.

Procedure:

  • Step 1: Open the fuse holder on the rear panel with a fitting screwdriver.
  • Step 2: Remove the old fuse from the fuse holder.
  • Step 3: Install the new fuse in the fuse holder.
  • Step 4: Replace the fuse holder in the housing.

TROUBLESHOOTING

The checklist below may help you troubleshoot in the unlikely event that a problem occurs while using the product:

Symptom

| Possible cause|

Suggested action

---|---|---
No response from the fixture.| No power to the fixture.| Check that the power is turned on. Check cables and connections.
 | Fuse blown or internal fault.| Replace the mean fuse or contact Beamz support or Beamz authorized service partner. Do not remove the base or yoke covers. Do not attempt to replace a fuse or carry out any repairs or services that are not described in this User Manual unless you have authorization from Beamz support or Beamz authorized service partner.
The fixture resets correctly but does not respond (or does not respond correctly) to the controller.| The controller is not connected.| Connect controller.
Bad DMX-line.| Inspect connections and cables. Correct poor connections. Repair or replace damaged cables.
 | DMX-line has no end resistance.| Insert DMX terminator plugin DMX output socket of the last fixture on DMX-line.
 | Incorrect fixture addressing.| Check fixture address and DMX mode settings.
 | A fixture is defective and is disturbing data transmission on the DMX line.| Unplug DMX IN and OUT connectors and connect them directly together to bypass one fixture at a time until normal operation is

regained. Have defective fixture serviced by an authorized technician.

 | Pin 2 and 3 are reversed in the XLR connection.| Inspect connections and cables. Install a phase-reversing cable between the fixtures or swap pins 2 and 3 in the fixture, that behaves erratically.
Error after fixture reset.| The effect requires mechanical adjustment.| Check the fixture’s software version and error messages for more information. Contact Beamz support or Beamz authorized service partner.
Light output cuts out intermittently.| The fixture is too hot.| Allow mixture to cool. Reduce ambient temperature. Ensure free airflow around the fixture. Clean fixture if necessary.
 | LEDs damaged| Disconnect the fixture and contact Beamz support or Beamz authorized service partner.
 | The power supply settings do not match the local AC voltage and frequency.| Disconnect fixture. Check settings and correct them if necessary.

CONTROL MENU

MENU   DESCRIPTION
DMX06 OK 001-512 “OK” represents the signal received;

“! !” represents no signal received;

“DMX06” represents the current channel channel 6;

“DMX02” represents the current channel as channel 2.

DMX CHX| 06CH| 06ch: Channel 6

02ch: Channel 2

 | 02CH
WORK MODE| DMX| Dmx512 console dimming mode
 | Rotate| Potentiometer dimming mode
 | Manual| Manual dimming mode
LED CCT| 4000K| Under manual mode, the CCT selected 2800k → 6000k
DIMMER| 100%| Under manual mode, the dimmer selected 000% → 100%
WW| 100%| Under rotate mode, console Warm White to select low CCT luminance (0%-100%)
CW| 100%| Under rotate mode, console Cool White to select high CCT luminance (0%-100%)
LED MODE| Smooth/Fast| Smooth: smooth dimming Fast: fast dimming
LCD BACK| Off/Open| Off: display turned off automatically after 30s without button operation Open: display always on
FAN MODE| High/Auto| High: The cooling fan is working at high speed

Auto: The cooling fan is working in an intelligent mode, the corresponding operation will be turned on automatically when reaching the appropriate temperature.

LED TEMP| 060C| Temperature in Celsius

DMX CHANNELS

6 Channels

CHANNEL FUNCTION VALUE DESCRIPTION
1 DIMMING 000-255 0 → 100%
2 STROBE 000-255 Slow → Fast
3 LOW CCT 000-255 0 → 100%
4 HIGH CCT 000-255 0 → 100%
5 0 000-039 Standard CCT
  2800K 040-079
  3200K 080-119
  4000K 120-159
  4800K 160-199
  5600K 200-239
  6000K 240-255
6 LOW CCT→HIGH CCT 000-255 No polar CCT

2 Channels

CHANNEL FUNCTION VALUE DESCRIPTION
1 DIMMING 000-255 0 → 100%
2 LOW CCT→HIGH CCT 000-255 No polar CCT

TECHNICAL SPECIFICATIONS

  • Product color Black
  • Light source Single color LED
  • Color temperature 2800K – 6000K
  • LED colours Cool White, Warm White
  • Quantity of LEDs 1
  • Beam angle: Min 15°
  • Beam angle: Max 40°
  • Illuminance 55.013 lx @ 1m
  • Flash rate per second 1 – 14Hz
  • DMX channels 2, 6
  • DMX connection 3-pin XLR
  • Modes DMX, Manual
  • IP rating IP20
  • Cooling Temperature-controlled fan
  • Display LCD
  • Power plug Power-connector
  • Power consumption 0.681A
  • Power supply 100-240VAC 50/60Hz
  • Dimensions (L x W x H) 355 x 395 x 210 mm
  • Weight 6,35
  • Included accessories Mounting bracket, Power cable, XLR cable

Design and product specifications are subject to change without prior notice.

The products referred to in this manual conform to the European Community Directives to which they are subject:

European Union

Tronios B.V.,
Bedrijvenpark Twente Noord 18, 7602KR Almelo, The Netherlands

  • 2014/35/EU
  • 2014/30/EU
  • 2011/65/EC

United Kingdom

Tronios Ltd.,
130 Harley Street, London W1G 7JU, United Kingdom

  • S.I. 2016:1101
  • S.I. 2016:1091
  • S.I. 2012:3032

offers a wide range of high-performance lighting equipment and related accessories for the rental, entertainment, and architectural lighting markets. BeamZ Pro stands for performance, innovation, and value pricing!

BEAMZLIGHTING.COM.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals