Glastender C1RL48 Remote Back Bar Coolers Instruction Manual
- August 22, 2024
- Glastender
Table of Contents
Glastender C1RL48 Remote Back Bar Coolers
Specifications
- Manufactured by: A Family Company in the USA Since 1969
- Year of Manufacture: 2017 and after
- Serial Number Range: 134169912 / 404169912 and above
- C1RL48 : Compressor hook up left, black vinyl-clad doors, stainless top
- C1RB48 : Compressor hook up right, black vinyl-clad doors, stainless top
- CP1RB48 : Refrigeration hook up left, stainless doors, no finished top
Utility Requirements and Connections
Uncrating and Start-Up Instructions:
- If legs are included, bolt them to the base with provided bolts.
- Position and level the unit, seal as required.
- Arrange for a licensed refrigeration contractor for refrigerant line routing and connections.
- Make field wire connections following local and national electrical codes.
- Plumb drain lines according to plumbing codes.
- Place shelves, set thermostat, load with product, and allow cooling time.
- Your equipment is now ready for use.
Cleaning Instructions
- Cleaning Time : 5-10 minutes daily, 45 minutes quarterly
- Cleaning Frequency : Daily exterior & gasket cleaning, quarterly interior & shelves cleaning.
Procedure:
- Use non-chlorine-based cleaner or mild detergent with warm water on contact surfaces.
- Rinse with warm water and dry with a soft cloth immediately.
Notes:
- Avoid harsh cleaners on stainless steel, always clean with the grain direction.
- Remove food deposits promptly to prevent rusting.
- Use appropriate product for black-vinyl-clad surfaces.
- Clean cooler door gaskets regularly to prevent premature failure.
*Cooler Serial Number Information
This manual is specific to remote coolers listed below manufactured in 2017
and after and beginning with serial number 134169912 / 404169912
- Back Bar – BB24, BB48, BB72, BB96
- Narrow Door – ND40, ND60, ND80, LN40, LN60, LN80
- Low Profile – LP48, LP72, LP96, LPT48, LPT72, LPT96
- Pass Thru – PT48, PT72, PT96, NP40, NP60, NP80
- Shallow Depth – NS40, NS60, NS80
- Bar Profile – C1RB24, C1RB40, C1RB48, C1RB60, C1RB72, C1RB80, C1RB96
- Low Profile – C1RL24, C1RL40, C1RL48, C1RL60, C1RL72, C1RL80, C1RL96
- Pass Thru – CP1RB24, CP1RB40, CP1RB48, CP1RB60, CP1RB72
- Pass Thru Low Profile – CP1RL24, CP1RL40, CP1RL48, CP1RL60, CP1RL72
- Shallow Depth – CS1RB40, CS1RB48, CS1RB60, CS1RB72, CS1RB80
Wiring Diagram
Installation
Introduction
This manual describes the operational features of the remote coolers listed on
the front of this manual. Please review this information before attempting
installation and operation. Long term, trouble-free service will follow if
good housekeeping and maintenance procedures are followed. Thank you for
selecting Glastender, Inc. products.
Utility Requirements and Connections
• Electrical : 120 Volt AC, 1 Phase, 60 Hz. A separate 15 Amp circuit is
recommended. Junction box is provided for field wire connections.
• Plumbing : Evaporator drain requires plumbing to a suitable vented drain
external to the cooler.
Uncrating and Start-Up Instructions
All models are shipped in one carton. These steps should be followed:
- If legs are included, bolt them to the base with the bolts provided.
- Position unit and level and/or seal as required (see pages 4 and 5).
- Arrange for a licensed refrigeration contractor to route the refrigerant lines and make the necessary refrigeration connections.
- Make field wire connections in accordance with applicable local and national electrical codes.
- Plumb evaporator drain line and/or beer tower drain line provided to a suitable external drain in accordance with applicable local and national plumbing codes.
- Place shelves in desired location.
- Set thermostat to desired temperature setting.
- Load with product and allow time to cool.
- Your Glastender equipment is now ready for use.
Operation
The operating temperature range is 34°F (1°C) to 40°F (5°C).
Cleaning Instructions
Cleaning is essential to sustaining the integrity of your equipment and
preventing corrosion.
- ESTIMATED CLEANING TIME : 5 to 10 minutes per unit daily, 45 minutes quarterly
- FREQUENCY : Daily cleaning of exterior & door gaskets. Quarterly cleaning of interior, including shelves.
PROCEDURE:
- A non-chlorine based cleaner or mild detergent and warm water applied with a soft cloth or sponge to all contact surfaces.
- Immediately rinse off cleaning agent(s), using clean warm water, clean soft cloth or sponge.
- Dry with a soft clean cloth, removing standing water as soon as possible.
NOTES:
- Never use hydrochloric acid, wire brushes, steel wool, scrapers, or chlorine based cleaners on stainless steel surfaces, since they will break down the passivity layer and allow corrosion to occur.
- On stainless steel surfaces, you may use a soft bristle brush or Scotch-Brite® pad for more stubborn stains. Always scrub with the direction of the grain. Follow with a thorough cleaning as described above.
- Deposits from food preparation must be properly removed. Even hard water deposits will rust stainless steel, if not removed.
- Repeated cleaning may dry up black-vinyl-clad steel (exterior) surfaces of the cooler. Armor All® or similar product can bring back the shine. Apply the product to a cloth and then rub into the surface, rather than spraying it directly onto the black-vinyl-clad surface.
- The cooler door gaskets are most often overlooked when cleaning. Failure to clean them regularly will lead to premature failure, since alcohol and moisture build-up breaks down the gasket material.
Sealing Vertical Door Cooler to Floor
To establish proper sanitation operation and to comply with NSF & health
codes, the cooler base must be sealed to the surface to which it is mounted
using an NSF listed sealant. Place a bead of sealant along outer edges of the
base and remove any excessive amount. Make sure there are no gaps in the
sealant as the intent is to prevent liquid spillage from adjacent surfaces
from passing under inaccessible portions of the equipment. This sealing
procedure does not apply to models that include legs or casters.
Attention Installer: WARNING!!
Failure to level this cooler WILL VOID THE FACTORY WARRANTY. Doors will not
close properly caus-ing damage to hinges, handles, and/or gaskets which will
adversely affect the refrigeration systems.
Cooler Installation Checklist
- Is the unit evenly and solidly supported, either upon legs, or flat on the base; check for high spots?If the unit was designed for legs, are they attached?
- Is the unit level at the base, from end to end?
- Do the doors open and close freely, without touching any other part of the unit in travel?
- Are there open holes to the outside of the cabinet which are not plugged or insulated?
- Are there obstructions of any kind to air flow into or out of the condensing unit?
- Is product tubing or are other lines installed in such a manner to not allow shelf access?
Special Instructions for Beer Tower Installation
Before you begin:
- Disassemble the tower into three parts, stiffener, skin, and top plate, by unscrewing the top two screws.
- Mount the column stiffener with the provided four 1/4″-20×1-1/2″ bolts.
- Install insulation provided into the bottom of the column stiffener.
- Place the column skin over the stiffener. Run the beer lines through the hole at the same time.
- Install insulation provided into the top of the tower assembly.
- Mount the column top plate to the column stiffener with the two #10-32×1/2″ phillips flat head s/s machine screws provided.
- Apply a bead of silicone sealant around the perimeter of the column. Use your finger to smooth out the bead.
- Wash tapping device and faucet with detergent and water. Flush beer tapping device and faucet lines.
Terms and Conditions
-
Prices:
All prices are LIST. Applicable taxes will be added. -
Quotations:
Unless otherwise stated, quotations are effective for 30 days only. -
Acceptance:
All orders are subject to acceptance by Glastender, Inc.’s headquarters in Saginaw, Michigan. Possession of the Product Directory and Price List is not an offer to sell. -
Shipments:
F.O.B. factory in Saginaw, Michigan. Freight terms are Third Party or Collect if shipped directly to you. Prepay and Add to Invoice freight terms are available upon request. The approximate shipping weights of all products are listed with the prices. Partial shipments will be made unless otherwise specified by the customer. Surface freight classifications are:- GT-24/GT-30/GW24 Glasswashers – Class 175
- GT-18 Glasswashers – Class 175
- All Underbar Equipment – Class 175
- Bar Die Orders – Class 250
- Portable Bars – Class 175
- Remote refrigerators (i.e., no compressor) or dry storage back bar equipment – Class 175
- Self-contained refrigeration equipment – Class 150
- Ice Display Units (IDU and GDU) – Class 175
- Lighted Liquor Displays – Class 175
- Beer line chillers and beer towers (beverage dispensing equipment) – Class 175
- Bottle Disintegration System – Class 150
- Ice Cream Freezers – Class 125
All small items are evaluated to see the most cost-effective means for shipment. Many small items ship via UPS or FedEx; however, when dimensional weight is excessive, LTL carriers are the most cost-effective choice. Spare parts orders received before 1:00 PM EST can usually be shipped the same day.
The order department is happy to assist with routing or shipping questions.
-
Payment Terms:
Cash should be included with all orders unless credit terms have been arranged. To establish credit, banking and trade references are required. A convenient credit application is available upon request. Payment via credit card is not our normal means of receiving payment. Visa and MasterCard will be accepted, but must be charged at the time of shipment. In addition, a payment via credit card for orders totaling more than $500 will incur a 3% convenience fee on the total transaction amount. -
Delivery:
The majority of equipment is manufactured to order and typically ships within three to six weeks after complete order information is received by the factory. In-stock equipment typically ships within two to three days of the factory receiving complete order information. -
Returns:
Items specified as “Manufactured to Order” are NOT returnable. A Return Authorization number must be issued by the factory in advance for any items that are returnable. The number MUST be noted on the outside of the returned package. Returns must be received within 90 days of the issue date. Shipping charges must be prepaid. A minimum 20% restocking charge will be applied to all authorized returns if received in new, unused condition in the original packaging. The above conditions apply to spare part returns, except spare part returns must be received within 30 days of original shipment for electronic or electrical parts or within 90 days for all other parts. -
Loss or Damage:
For customer routed shipments, Glastender, Inc. is not responsible for any loss, damage, or delay of merchandise during shipment. Such transit claims must be filed with the carrier. Merchandise must be examined on arrival. If shortages occur, Glastender, Inc. must be notified in writing within five (5) days of delivery to honor any shortage claim. Glastender will assume responsibility for freight claims on Prepay and Add shipments but the customer must inspect freight and note any damage upon receipt. Failure to do so may result in losses at the customer’s expense. -
Custom Orders:
Custom orders must be paid in advance and are not subject to cancellation. -
Laminates :
Some products include common, readily available plastic laminates of the customer’s selection. There may be an additional charge if uncommon varieties are ordered.
Glastender Freight Program
Program Conditions
Glastender, Inc. equipment pricing includes standard freight costs under the
following conditions:
- Equipment order is for a minimum of $2,500, shipped to a single destination at the same time.
- Freight carrier is selected by Glastender, Inc. and may vary based on destination, transit times, performance history, customer service, or other factors.
- Shipping destination is within the continental United States and Canada. Non-continental or other international destinations are shipped to port of export.
- Combining equipment orders is allowed to reach the minimum order level if combined orders are shipped to the same destination at the same time.
- Equipment order terms of sale are FOB Saginaw MI / Freight Prepaid.
- Equipment returns are not covered.
- Parts orders do not qualify and will be charged shipping accordingly.
Customer Responsibilities
In addition to the program conditions listed above, the receiving customer
must:
- Note all damage on the delivery receipt at the time of delivery.
- Open and inspect any items that look suspicious or raise concern, even if the carrier tells you it is not allowed.
- Refuse only the damaged items and keep the other items on the order.
- When in doubt, sign the delivery receipt as damaged. The only way to hold the carrier liable is to sign the delivery as damaged.
Additional Fees
Additional carrier-related services and fees over and above standard freight
costs are not covered. Such services and fees will be invoiced at the time of
order or after the order has shipped. Examples of additional fees include the
following:
- Split shipment…………………………..Cost difference between single shipment and split shipment
- Lift gate……………………………………$55 (Only available for items under 96″ in total packaged length)
- Inside delivery…………………………..$100 per pallet/piece
- Residential delivery…………………..$100
- Limited access site……………………$100
- Expedited delivery…………………….Difference from standard rate
- Special delivery time…………………Carrier rate
- Storage……………………………………Carrier rate
- Re-delivery………………………………Carrier rate
- Re-consignment……………………….Carrier rate
Other additional services not listed…Carrier rate Questions For questions regarding the Glastender Freight Program, please contact Shipping & Receiving: Steve Gunn, Shipping & Receiving Supervisor 989.752.4275, ext 141 • sgunn@glastender.com
Warranty Statement
APPLICABLE TO ALL PRODUCTS SOLD WITHIN THE UNITED STATES AND CANADA
- Glastender, Inc. warrants all products to be free of defects in material and workmanship. One-year labor and parts warranty applies to all glasswashers, self-contained refrigeration models, and BDS model bottle disintegration units. In established areas, a start up is included with GT-24 and GT-30 model glasswashers. Warranty is effective for one year from the date of installation or up to 18 months from date of factory shipment, whichever occurs sooner. Glastender,
- Inc. will replace any part or assembly found defective under normal use and service.
- For warranty labor claims beyond 12 months from the date of factory shipment, proof of date of installation or occupancy must be provided. Authorization for labor must be obtained from Glastender within the warranty period and prior to the service being performed.
- Labor warranty applies to the 50 states of the USA and Canada only.
- Remote refrigeration models exclude the labor warranty for the condensing unit and issues related to the field installation and test of the completed refrigeration system, provided by others.
- Field replacement parts not covered under the original warranty include a 90-day part warranty from the date of installation.
FOUR-YEAR ADDITIONAL COMPRESSOR WARRANTY
- Glastender will warrant to the original user the compressor for all self-contained refrigeration models for an additional four years following the regular one-year warranty period. This plan applies to the compressor only.
- A completed warranty claim form MUST accompany all returned defective parts or assemblies. Upon request, a defective part or assembly must be returned to Glastender, Inc., Saginaw, Michigan, with all transportation and delivery charges prepaid. Warranty repairs or replacements will be shipped FOB factory in Saginaw, Michigan. Reimbursement for applicable freight charges covers ground service only.
- Glastender provides in-warranty repairs during a service company’s regular working days and hours. There is no provision for payment of a premium rate during “overtime” hours. When warranty service is requested during other than normal working hours, the end user will be charged the premium portion of the overtime rate.
- The warranty covers substantiated travel expenses for up to 2 hours / 100 miles round trip up to a maximum of $225. Any additional costs due to installations that require extra work, time, or travel to gain access for service are the sole responsibility of the equipment purchaser. Any exceptions to these travel and access limitations must be pre-approved by a factory representative.
- The warranty does not cover door gaskets, chemical tubing, pump squeeze tubing, and/or any equipment subjected to accidents, freight damage, alterations from the original design, improper power and/or plumbing hookups, improper chemical use, general misuse, or lack of routine required maintenance as determined by Glastender, Inc. Installation, normal control adjustments, general maintenance, correcting an installation error, or service calls that reveal the unit is functioning normally will not be reimbursed under warranty.
- Condenser coils on self-contained refrigeration products must be cleaned regularly. Failure to provide adequate airflow to a refrigeration unit will void the warranty.
- Glastender shall not be liable for loss of use, revenue, or profit, or for any other indirect, incidental, special, or consequential damage including, but not limited to, product spoilage or loss. This warranty is conditioned upon Glastender receiving notice of any defect subject to this warranty within sixty (60) days of its discovery by the end-user or dealer. All products are warranted only for the initial place of installation. Removal of a product automatically terminates this warranty.
SECOND-YEAR EXTENDED PARTS & LABOR WARRANTY
Glas tender’s one-year parts and labor warranty on self-contained
refrigeration units can be extended to two years with the purchase of a two-
year parts and labor warranty. Specify part number EWR2 ($250 net price) when
ordering.
EXPORT WARRANTY – One-year parts only.
EXCLUSION OF WARRANTIES
EXCEPT AS PROVIDED ABOVE, GLASTENDER MAKES NO WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY,
FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT.
LIMITATION OF REMEDIES AND DAMAGES
If Buyer makes a valid and timely claim as outlined above, Glastender’s
liability and Buyer’s remedies under this agreement will be limited solely to
labor charges authorized and/or replacement or credit, at Glastender’s option,
with respect to Products returned at Buyer’s expense within thirty (30) days
after warranty repair.
GLASTENDER’S LIABILITY WILL IN NO EVENT BE GREATER IN AMOUNT THAN THE PURCHASE
PRICE OF THE RETURNED PRODUCTS. GLASTENDER WILL NOT BE LIABLE UNDER ANY
CIRCUMSTANCE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, INCLUDING, BUT NOT
LIMITED TO, LABOR COSTS EXCEPT AS COVERED UNDER OUR WARRANTY, LOST PROFITS OR
THE LOSS OF PERISHABLE PRODUCTS RESULTING FROM THE USE OF OR INABILITY TO USE
OUR PRODUCTS OR FROM OUR PRODUCTS’ INCORPORATION INTO OR BECOMING A COMPONENT
OF ANY OTHER PRODUCT. NEITHER PARTY WILL HAVE ANY NEGLIGENCE OR OTHER TORT
LIABILITY TO THE OTHER, OR TO ANY THIRD PARTY, ARISING FROM ANY BREACH OF THIS
AGREEMENT.
GOVERNING LAW – JURISDICTION
The terms and conditions of an order are to be governed and construed according to the laws of the State of Michigan, without regard to conflict of laws principles. Buyer hereby consents to the jurisdiction and venue of the courts located in Saginaw County, Michigan. No representative, distributor, dealer, or any other person is authorized to modify this warranty. This warranty replaces all other written or verbal warranties.
NOTE : Glastender, Inc.’s policy of constant quality improvement means that prices, specifications, and policies are subject to change without notice. Questions regarding this warranty should be directed to Glastender’s Warranty Administrator.
IMPORTANT!!
Attention Service Companies
Please review the important warranty information on this page. If you believe
a service call should be covered by the factory, please call the factory for
authorization between 8AM and 5PM EST, Monday through Friday.
Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780 800.748.0423 • 989.752.4275 • Fax 989.752.4444 • https://glastender.com
FAQ
Q: How often should I clean the cooler door gaskets?
A: The cooler door gaskets should be cleaned regularly to prevent premature
failure. Daily cleaning is recommended to avoid alcohol and moisture build-up
that breaks down the gasket material.