ratio 696X8 Silent-6 Portable Compressor Instruction Manual
- June 13, 2024
- ratio
Table of Contents
ratio 696X8 Silent-6 Portable Compressor Instruction Manual
Introduction
We appreciate the trust placed in our brand and we hope that the compressor you have just acquired will be very useful. Your machine has many features that will make your job faster and easier. Safety, comfort and reliability were taken as a priority for the design of this equipment, which makes maintenance and operation easy.
General Safety Rules
WARNING !: These instructions have been developed to facilitate the installation, operation and proper maintenance of the equipment. Read the complete manual carefully before commissioning the compressor to understand its functionalities and reduce risks during its operation. Read and understand all instructions. Be sure to pay attention to all warnings and cautions throughout this manual. Failure to follow the instructions contained in this manual may result in electric shock, and / or serious personal injury.
WORK-AREA
- Keep your work area clean and well lit. Messy tables and dark areas can cause accidents.
- Do not use the compressor in explosive atmospheres, such as in the presence of flammable liquids, gases or dust. The electric tool generates sparks that can cause fires.
Electrical Safety
WARNING!:
- Before connecting the compressor to a power source (mains socket, generator, etc.) make sure that the voltage provided is the same as the one mentioned on the technical data plate of the equipment. A source of power greater than that specified for the compressor can cause serious injury to the user, as well as equipment damage.
- Avoid body contact with grounded surfaces such as pipes, radiators and refrigerators. There is an increased risk of electric shock if your body is grounded.
- Do not expose the compressor to rain or moisture conditions. The entry of water into the equipment will increase the risk of an electric shock.
- Do not damage the cable. Never use the cable to carry the compressor or pull the cable out of the outlet. Keep the cable away from heat, oil, sharp edges and moving parts. Replace damaged cables immediately. Damaged cables increase the risk of electric shock.
- When using the outdoor compressor, if required, use an outdoor extension cord. These extensions are designed to work outdoors and reduce the risk of electric shock.
- It is recommended that you use an appropriate safety device, such as a thermal and differential switch when using electrical equipment.
Personal Security
- Stay alert, watch what you are doing and use common sense when using the compressor. Do not use it when you are tired or under the influence of drugs, alcohol or medication. A moment of distraction while working with the equipment can result in serious injury.
- The warnings, precautions and instructions in this manual do not cover all possible situations that may arise. The good common sense of the operator and his own precaution, are factors that can not be manufactured with the compressor.
- Always be careful when using the compressor. Keep it out of reach of observers and children. Always work with the appropriate protective equipment for the work you are going to do (masks, goggles, etc.)
Additional safety rules for air compressors
WARNING !: Compressed air is a potentially dangerous form of energy,
always be very careful when using the compressor and pay special attention to
the warnings in this manual.
WARNING !: The compressor starts up unexpectedly to recharge the air in
the tank, as a result of the normal programmed work sequence. Place the
compressor in a clean, dry and well-ventilated area, with an ambient
temperature between+52C,and+40°C.
- The compressor must be located at a minimum distance of one meter from the wall or any other obstruction that interferes with the air flow.
- Place the compressor on a smooth, level surface.
- Keep the sides and other adjoining areas clean that can pick up dust or dirt. A clean compressor works better and lasts longer.
- Do not place rags, containers or other materials on top of the compressor that could obstruct the ventilation openings or air intake in the fans, in order to maintain the proper operating temperature.
- Do not force the compressor. Use it following the specifications, so it will perform better and more safely the work for which it was designed.
- Always use the switch (5) to turn the compressor on and off. Do not use the equipment if the switch does not work properly.
- Use the carrying handle (2)
- Always wear safety glasses to protect your eyes from objects that may be projected by the air stream.
- Never direct the jet of sprayed liquid through the tools connected to the compressor to it.
- When performing compressor maintenance, only spare parts or accessories recommended by the manufacturer should be used. Follow the instructions in the maintenance section of thismanual. The use of unauthorized parts or failure to follow maintenance instructions may result in the risk of electric shock or injury.
- Do not alter or misuse the compressor. This equipment was built with precision. Any alteration or modification not specified is a misuse and can lead to dangerous situations.
- Never leave the compressor exposed to adverse weather conditions such as rain, fog, snow or heavy sun.
- Repair of the compressor must only be carried out by qualified personnel. Repair or maintenance performed by an unqualified person can create risk of injury.
- Do not manipulate, drill or weld the tank. In case of defects or rust, contact our technical services.
- Air regulator: Controls the outlet pressure of the air flow. Turn the regulator clockwise to increase the pressure and counterclockwise to reduce it.
- Handle: With anti-slip rubber that allows an easy and safe movement. ]
- Air outlet: With universal quick connector that allows you to connect a hose safely, comfortably and easily.
- Vent: Allows emptying of the air tank and water by condensation. |
- O / F switch pressure switch to turn the compressor on and off |
- Pressure gauge: Indicates the outlet pressure selected with the regulator (1). (Figure A). |
- Safety valve: Relieves the pressure of the tank in the event of it exceeding 8.8 bar. The valve is a critical element in the safety of the compressor. It must not be manipulated under any circumstances. Periodically check its operation by pulling slightly on the ring.
- Air reservoir: Stores the air produced by the compressor head.
- Air filter: Ensures compressor operation free of impurities. Starting the compressor without the air filter installed may cause damage to the inside of the compressor head. (See assembly in figure
- Wheels: It facilitates the displacement of the compressor in a safe and comfortable way. This equipment is not suitable for towing by a vehicle. (only on models with wheels).
- Rubber plugs: They prevent the movement of the compressor and the transmission of vibrations (only on models with wheels)
- Fans: Provide the necessary air flow to keep the compressor at the proper operating temperature.
Before carrying out assembly or maintenance, make sure that the compressor is switched off and disconnected from the power supply and located inside the packaging:
**The air filter.
**
OPERATING PRINCIPLE.
To understand the air, the piston moves up and down inside the cylinder. In
the down stroke, the air is contracted through the inlet valve. The discharge
valve remains closed. In the upward stroke of the piston, the air is
compressed. The inlet valve closes and the compressed air is forced to be
directed towards the tank through the non-return valve. In a conventional
piston compressor, the air load is maintained until reaching the maximum
pressure, 8 bar. The electronic pressure control that this compressor
incorporates allows to select a lower maximum pressure limit, which reduces
the waiting time to start work.
TECHNICAL SPECIFICATIONS.
TECHNICAL DATA. PRO24SILENTX
VOLTAGE / FREQUENCY. 1 ~ 230V. – 50Hz.
MAXIMUM MOTOR POWER. 1.5 Hp.
CAPACITY OF THE DEPOSIT. 24 L.
MAXIMUM PRESSURE. 8 Bar.
MAXIMUM AIR FLOW. 150L / MIN. R.P.M. 1,500
ACOUSTIC POWER (LwA) 62 dB.
WHEN YOU FINISH THE WORK
START UP.
ATTENTION!: Before starting to operate with your new compressor, please
read these instructions carefully. The accounts to operate safely. Save them
for future reference.
CONNECTION TO THE POWER SUPPLY.
Before connecting the compressor and the power supply, check that the data on
the nameplate matches the values of this and all connections are tight, to
avoid air errors, bad contacts and overheating. Connect the compressor to a
socket with protection and grounding devices: The compressor is connected to a
red wire with a ground connection. This can be connected to any 230V ~ 50 Hz
grounding socket that is protected with 16 A. Before commissioning, make sure
the red voltage matches the operating voltage indicated on the motor power
plate. Cables of great length such as, p. ex. Extension cords, winding drums,
etc. they cause voltage drops and can hinder the machine’s running. The low
temperatures, lower than 5 ° C, can hinder the running of the motor.
ON / OFF switch (5) The compressor is connected by pulling the button (8). To disconnect the compressor simply press the button.
The pressure switch has been adjusted at the factory. Connection pressure: ca. 6 bars Disconnection pressure: ca. 8 bars
PRESSURE ADJUSTMENT:
The pressure can be regulated in the manometer All compressors are equipped
with a pressure reducer. The air pressure can be adjusted by pulling slightly
upwards and turning clockwise to increase the pressure and in the opposite
direction to reduce the pressure After adjusting the optimum output pressure
push the button down to secure it
WHEN THE WORK HAS FINISHED:
ALWAYS DISCONNECT THE COMPRESSOR OFF FIRST THE BUTTON OF THE PRESSURE SWITCH,
THEN UNPLUG THE CABLE
Maintenance
- This compressor is self-lubricating, but it is not necessary to add oil.
- At the end of the work, empty the condensation of the air in the tank with the trap (4).
- Check for any unusual noise or vibration.
- Keep the air inlet filter clean and unobstructed, to avoid limiting air intake into the compressor.
- In case of transport and / or storage, the compressor must not expose to temperatures outside the range: + 52C to + 402C.
- In case of malfunction or breakdown, it is not a question of repairing unless you have the appropriate technical qualifications and tools. Contact one of our technical services, which on our website www.grupocevik.es.
- Inspect the air system for possible losses, at least once a month, applying soapy water to all joints. Tighten those you discover that have losses.
Problem Solving
Power switch will not work
A-Electronic control of damaged pressure.
[ contact a Technical service.
The operation indicator lights
A-The tank pressure is higher than the lower pressure of the selected
working mode.
Readjust the work mode, if necessary.
B- The supply voltage is less than 220V. Do not use a power cord
extension.
Look for an alternative energy source.
C- Loss of contact in some electrical connection. The connections
obtained.
Condenser or control circuit damaged.
Contact a Technical Service.
loss of air pressure in the tank or very slow load
A-The tank trap is not properly closed.
Close the trap.
B- Safety valve is open. The safety valve pull the ring, if the problem
persists replace it.
Dirty or clogged air filter.
Clean or replace.
Excessive heating
A-Fan does not work. Replace the fan.
Clogged or clogged fans.
Remove the obstruction.
Any other cause. Unknown get in touch with one of our technical services.
WARRANTY.
Duration of the guarantee period:
- 36 months, according to R.D. 7/2021 of April 27, which modifies the consolidated text of the General Law for the Defense of Consumers and Users (*) and other complementary laws, approved by R.D. 1/2007, of November 16.
- 12 months, for Companies or Professionals who use the product to carry out an activity for profit.
(*) Royal Decree 1/2007. Article 3. General concept of consumer and user.
For the purposes of this rule…, consumers or users are natural persons who act
for a purpose unrelated to their commercial, business, trade or profession.
Coverage: The guarantee requires the manufacturer to repair or replace for free all components subject to verified manufacturing defects. The Official Technical Assistance Service will be responsible for the repair or replacement in the shortest possible time, compatibly with the internal commitments of the service, without any obligation of compensation or reparation for direct or indirect damages.
The following are excluded from the guarantee:
- The consumption materials.
- Damages to people, animals or things caused by improper use, improper installation, modifications not approved by the manufacturer, incompetence or non-observance of the rules contained in these instructions for use and operation.
Expiration:
The warranty will be voided in case:
- The guarantee period of 36/12 months counted from the date of sale is expired.
- The instructions contained in this manual have not been observed.
- An improper use of the product has been verified.
- The machine has been used outside the parameters defined in the specifications of the product.
- The characteristics of the equipment have been manipulated or altered by unauthorized persons.
ENVIRONMENTAL PROTECTION.
In accordance with the provisions of the European Directive 2012/19/EU on waste electrical and electronic equipment (WEEE) and its transposition into national legislation, this product should not be disposed of with household waste. If the machine or any of its accessories or components must be replaced, make sure to dispose of them through the collection system established in your area for this type of product.
The separation of waste from used products and packaging allows to reuse and recycle materials. The reuse of recycled materials helps avoid environmental pollution and reduces the demand for ‘ raw materials.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>