beamZ Pro NEUTRON-DOT Linkable 60W Light User Manual
- August 16, 2024
- beamz Pro
Table of Contents
beams Pro NEUTRON-DOT Linkable 60W Light
SAFETY INSTRUCTION
WARNING
Before carrying out any operations with the unit, carefully read this
instruction manual and keep it with care for future reference. It contains
important information about the installation, usage, and maintenance of the
unit.
- Unpack and check carefully that there is no transportation damage before using the unit
- Please read these instructions carefully and follow the instructions.
- Observe all safety warnings. Never remove safety warnings or other information from the equipment.
- Be sure that no ventilation slots are blocked; otherwise, the unit will overheat.
WARNING
Before connecting the equipment to the power outlet, first, verify that the
mains voltage and frequency match the values specified on the equipment. If
the equipment has a voltage selection switch, connect the equipment to the
power outlet only if the equipment values and the main power values match. If
the included power cord or power adapter does not fit in your wall outlet,
contact your electrician.
- After connecting the unit, check all cables to prevent damage or accidents, e.g., due to tripping hazards.
- Make sure that the power cord is never crimped or damaged. Check the unit and the power cord from time to time.
- Always disconnect power from the mains, when the unit is not used or before cleaning! Only handle the power cord by the plug. Never pull out the plug by tugging the power cord.
- Unplug the power cord and power adapter from the power outlet if there is a risk of a lightning strike or before extended periods of disuse.
- Do not switch the unit on and off in short intervals.
- Do not connect the unit to a dimmer pack.
- Install the unit in a well-ventilated place.
- Never place any material over the lens.
- Never let the sunlight light directly to the front lens, even when the unit is not working.
- Always allow free air space of at least 50 cm around the unit for ventilation.
- Make sure that the area below the installation place is blocked when rigging, de-rigging, or servicing the unit.
- For mounting height >100 cm, always fix the unit with an appropriate safety rope. Fix the safety rope at the correct fixation points only. The safety-rope must never be fixed at the transport handles!
- Never look directly at the light beam. Please note that fast changes in lighting, e. g. flashing light, may trigger epileptic seizures in photosensitive persons or persons with epilepsy.
- This unit is not designed for permanent operation. Consistent operation breaks will ensure that the unit will serve you for a long time without defects.
WARNING
If the power cord of the unit is equipped with an earthing contact, then it
must be connected to an outlet with a protective ground. Never deactivate the
protective ground of a power cord.
- Make sure that the unit is not exposed to extreme heat, moisture, or dust.
- Clean the unit using a dry cloth.
- Do not touch the unit bare-handed during its operation (housing becomes very hot). Allow the unit to cool for at least 5 minutes before handling.
- This unit is designed exclusively for indoor use, do not use this equipment near fluid (does not apply to special outdoor equipment – in this case, observe the special instructions noted below). Do not expose this unit to flammable materials, fluids, or gases.
- If the unit has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The rising condensation water might damage your unit. Leave the unit switched off until it has reached room temperature.
- Never attempt to bypass the thermostatic switch or fuses.
- Do not dismantle or modify the unit.
- For replacement use fuses/bulbs of the same type and rating only.
- Repairs, servicing, and electric connection must be carried out by a qualified technician.
- The ambient temperature must always be between -5° C and +45° C.
- If this unit is operated in any other way, than the one described in this manual, the product may suffer damages and the warranty becomes void.
- Plastic bags must be kept out of reach of children.
- The unit must be installed out of the reach of children. Never leave the unit running unattended.
- This symbol on the product or its packaging indicates that this product shall not be treated as household waste. Instead, it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.
By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of the product. The recycling of materials will help to conserve natural resources. For more detailed information about recycling this product, please contact your local Civic Office, your household waste disposal service, or the shop where you purchased the product.
UNPACKING INSTRUCTION
CAUTION
Immediately upon receiving the product, carefully unpack the carton, and
check the contents to ensure that all parts are present, and have been
received in good condition. Notify the shipper immediately and retain the
packing material for inspection if any parts appear damaged from shipping or
the package itself shows signs of mishandling. Save the package and all
packing materials. If the product must be returned to the factory, the product
must be returned in the original factory box and packing. If the unit has been
exposed to drastic temperature fluctuation (e.g. after transportation), do not
switch it on immediately. The rising condensation water might damage your
unit. Leave the unit switched off until it has reached room temperature.
POWERSUPPLY
The label on the backside of the unit indicates the mains voltage to which
it must be connected. Check that the mains voltage corresponds to this. Any
other voltage than the one indicated may cause irreparable damage to the unit.
The unit must also be connected directly to the mains voltage and no dimmer or
adjustable power supply may be used. The unit has a power connector output on
board. Depending on the local conditions several units can be linked by
powerconnector in- and output. Connect a maximum of four (when using 230V/16A)
units in a row. Use an approved three-core cable with a cross-section of at
least 1.5 mm². The installation instructions of the manufacturer and the color
coding of the cable must be observed. Do not turn off the unit by turning the
power connector but use the power on/off switch or schuko!
WARNING
Always connect the unit to a protected circuit (circuit breaker or fuse).
Make sure the unit has an appropriate electrical ground to avoid the risk of
electrocution or fire.
RIGGING
The unit may be set up on a stable and even surface. Using the fixing facilities of the baseplate, the unit can also be mounted upside down to a truss, see the below picture. For fixing, certified clamps with the correct save working load are required. According to the figure, the quick lock bolts of the omega brackets are placed into the openings provided in the base plate and turned clockwise until they lock (to the stop). The mounting place must be of sufficient stability and be able to support a weight of 10 times the unit’s weight. Secure the unit with a safety cable so that it cannot fall. When carrying out any installation, always comply with European and national guidelines concerning rigging, truss, and all other safety issues. Always let the installation be checked out by an authorized dealer!
DMX512 CONTROL
If you are using a standard DMX controller, you can connect the DMX output of the controller directly to the DMX input of the first unit in a DMX chain. Always connect the output of one unit with the input of the next unit until all units are connected.
CAUTION
At the last unit, you must close the DMX line with a terminating resistor.
Take an XLR connector and solder a 120 Ohm resistor between signal (-) and
signal (+) and connect it to the DMX output of the last unit in the line.
RDM CONTROL
This unit can communicate using RDM (Remote Device Management) via DMX512.
RDM is a bi-directional communication protocol for use in DMX512 control
systems, it is the open standard for DMX512 configuration and status
monitoring. The RDM protocol allows data packets to be inserted into a DMX512
line without affecting the existing non-RDM equipment. The system allows a
controller or special RDM controller to send and receive commands from
specific fixtures. The RDM function allows you, for example to remotely set
the DMX start address of your fixtures. This is especially useful when the
fixture is installed in an inaccessible location. Each unit has an RDM UID
(unique identification number).
CLEANING
The buildup of dust, dirt and other airborne particles will reduce the unit’s light output. It will also prevent the unit from cooling correctly, and this will reduce the unit’s lifetime. The rate of dirt buildup will vary depending on environmental factors such as airborne dust, use of smoke machines, airflow from ventilation systems, etc. The unit’s cooling fans will accelerate buildup, and any smoke particles that are present in the atmosphere will increase the tendency for dirt to clog. To get the best performance and lifetime from the unit, inspect it regularly and clean it as soon as you see signs of dirt buildup. Assess the operating environment each time you begin to use the unit. In dusty or smoky conditions, inspect the unit after a few hours and check it frequently the unit may attract dirt faster than you expect. Draw up a cleaning schedule that will make sure that dirt is removed before it can build up.
Use the following guidelines:
- Disconnect the unit from power and allow it to cool completely before cleaning.
- Do not use solvents, abrasives or any other aggressive product to clean the unit.
- Vacuum or use low-pressure compressed air to remove dust and loose particles from surfaces and air vents. Prevent the blades of cooling fans from turning before you aim a vacuum or air jet at the fan, or you may spin the fan too fast and damage it.
- Clean glass components by wiping gently with a soft, clean, lint-free cloth moistened with a weak detergent solution. Put the solution on the cloth and not on the surface to be cleaned. Avoid rubbing glass surfaces.
- Dry the unit with a soft, clean, lint-free cloth or low-pressure compressed air before reapplying power.
PROTECTION CLASS IP65
Units with protection class IP65 are dust-tight and completely protected against contact (first code number). They are also protected against splash water from any angle (second code digit). That is why this unit can also be used out‐ doors. Events units are generally only designed for temporary use however (event lighting) and not for permanent use outdoors. The specified protection class does not make a statement about the weather resistance of the units (resistance to changing ambient conditions as well as against the effects of sunlight and UV rays). The seals and screw connections of the units must be checked regularly to ensure a fault-free operation.
MAINTENANCE
This unit is virtually maintenance-free, but you should check the unit regularly for mechanical and electrical aspects. Assess the operating environment and establish an inspection and cleaning schedule that follows the guidelines below:
- Disconnect the unit from the power supply and allow it to cool completely before inspecting and cleaning.
- Check that the screws and bolts used to install the unit are securely tightened and free from corrosion.
- Check the housing, fixing points and installation points, they must not show any signs of deformation, wear or fatigue.
- Check the mechanically moving parts, these must not show any signs of wear or fatigue.
- Check the electrical power and signal cables, they must not show any damage or fatigue.
- Do not use solvents, abrasives or other aggressive products to clean the unit.
- Wipe the unit and clean the glass plate with a soft, clean, lint-free cloth moistened with a weak cleaning solution. Place the solution on the cloth and not on the surface to be cleaned. Avoid rubbing glass surfaces.
- Dry the unit, connectors and contacts with a soft, clean, lint-free cloth or low-pressure compressed air before re-powering the unit.
TROUBLESHOOTING
The checklist below may help you troubleshoot in the unlikely event that a problem occurs while using the product:
CONTROL MENU
DIMMING CURVES
DMX CHANNELS
16 CHANNEL
64 CHANNEL
TECHNICAL SPECIFICATIONS
-
Product color Black
-
Light source Single color LED
-
LED colours Red, Green, Blue, Warm White
-
LED power (single LED) 60W
-
Color temperature 2700K
-
Quantity of LEDs 1
-
LED power: Backlight 1W
-
Quantity of backlight LEDs 16
-
Beam angle 23°
-
Illuminance 61.331 lx @ 1m
-
Flash rate per second 0 – 20Hz
-
DMX channels 1, 3, 4, 16, 64
-
DMX connection 3-pin XLR
Modes Automatic programs, DMX, Master/Slave -
IP rating IP65
-
Cooling Temperature-controlled fan
-
Display OLED
-
Power plug Power-connector TR
-
Power consumption 0.944 – 0.473A
-
Power supply 100-240VAC 50/60Hz
-
Dimensions (L x W x H) 142 x 142 x 218mm
-
Weight 2,30
-
Included accessories Mounting bracket, Power cable
Design and product specifications are subject to change without prior notice. The products referred to in this manual conform to the European Community Directives to which they are subject:
European Union
Tronios B.V.,
Bedrijvenpark Twente Noord 18, 7602KR Almelo, The Netherlands
- 2014/35/EU
- 2014/30/EU
- 2011/65/EC
United Kingdom
Tronios Ltd., 130 Harley Street, London W1G 7JU, United Kingdom
- S.I. 2016:1101
- S.I. 2016:1091
- S.I. 2012:3032
offers a wide range of high-performance lighting equipment and related accessories for the rental, entertainment and architectural lighting markets. BeamZ Pro stands for performance, innovation and value pricing!
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>