UBIBOT NR1 Smart Network Relay User Manual

August 14, 2024
UBIBOT

UBIBOT NR1 Smart Network Relay

Specifications

  • WiFi antenna
  • RS485 interface (5V)
  • Wiring terminal
  • RS485 interface (12V)
  • Ethernet cable port* DC12V
  • TYPE-C
  • Function button
  • Device status indicator
  • Relay status indicator
  • Relay output

PACKAGE LIST

Note: Please tighten the antenna before use.

INTRODUCTION

Basic Features Introduction

Device Operations

  • Switch On/Off
    After the power is plugged in/unplugged, the device will Switch On/Off automatically.

  • Setup Mode
    With the device switched on, press and hold the function button for about 5 seconds until the device status indicator flashes red and green alternately. Release at this time to enter the setup mode.

  • Send data
    Under power-on state, press the function button once, the green device status indicator will flash, then connect to the network and send data.

  • Reset to Default Settings
    Under power-on state, press and hold the function button for about 15 seconds until the red device status indicator blinks, then release the button to restore factory settings.

Electrical Wiring

Interface

  1. COM
  2. Digital Input 1
  3. Digital Input 2
  4. Digital Input 3
  5. Digital Input 4
  6. COM+
  7. Output of DC 12V
  8. NO node of Relay 1
  9. COM node of Relay 1
  10. NC node of Relay 1
  11. NO node of Relay 2
  12. COM node of Relay 2
  13. NC node of Relay 2
  14. NO node of Relay 3
  15. COM node of Relay 3
  16. NC node of Relay3
  17. NO node of Relay 4
  18. COM node of Relay 4
  19. NC node of Relay 4

Device Operations

  1. Passive switch (dry contact): passive contact signal, with two states (off/on), no polarity between the two contacts, such as various types of switches, buttons, etc.

  2. Active switches (wet contact, DC5-12V): signals with voltage (high/low level, pulse), with two states (power/no power), polarity between the two contacts, such as liquid level detection, smoke detection, PLC output, infrared detection, flow detection, etc.

  3. Relay Output Wiring

  4. Low load wiring: Non-resistive load current less than 3A or resistive load less than 5A.

  5. AC 220V load wiring: external load is AC 220V power supply.

  6. AC 380V (with null line) Load wiring: The external load is AC 380V with null line.

If necessary, insert an AC contactor/intermediate relay between the product and the external load.

  1. Rated load voltage > DC 30V
  2. Load rated voltage > AC 250V
  3. Non-resistive load current > 3A
  4. Resistive load current > 5A

DEVICE SETUP OPTIONS

Option 1: Using Mobile App
Download the App from www.ubibot.com/setup, or search for ‘Ubibot’ on the AppStore or Google Play.

We recommend you try to use the PC Tools in case the App setup fails, because the failure may be due to mobile phone incompatibility. The PC Tools is much easier to operate and suitable for both Mac and Windows.

Option 2: Using PC Tools
Download the tool from www.ubibot.com/setup.
This tool is a desktop app for device setup. It is also helpful in checking setup failure reasons, MAC address, and offline charts. You can also use it to export offline data stored in the device internal memory.

SETUP USING THE APP FOR WiFi CONNECTION

Launch the App and log in. On the home page, tap “+” to start adding your device. Then please follow the in-app instructions to complete the setup. You can also view the demonstration video at www.ubibot.com/-setup for step by step guidance.

Via our app and web console (http://console.ubibot.com), you are able to view the readings as well as config-ure your device, such as create alert rules, set data syncinterval, etc. You can find and watch the demonstration videos at www.ubibot.com/setup.

SETUP USING THE APP FOR ETHERNET CABLE CONNECTION

  • STEP 1. Connect the device with power supply and plug the Ethernet cable.
  • STEP 2. Launch the app and log in. On the home page, tap “+” to start adding your device. Then please follow the in-app instructions to complete the setup. You can also view the demonstration video at www.ubibot.com/setup for step by step guidance.

SETUP USING PC TOOLS

  • STEP 1. Launch the App and log in. With the device switched on, use the Type-C USB cable provided to connect your device to the computer. The PC Tools will automatically scan and recognize the product ID and enter the device page.
  • STEP 2. Click “Network” on the left menu bar. There, you are able to set up the device on WiFi for all the models. For the SIM or Ethernet cable setup, please click on the corresponding button to continue.

RS485 COMMUNICATION

The default mode is the RS485 communication slave mode. If the external sensor collection time is set in the platform, the master mode for data collection will be activated and the slave mode will be turned off automati-cally. If the device has been networked, the setting parameters are set by the platform.
For more details, please contact your local distributor or refer to the online documentation.

DEVICE USE

Working Mode

  1. Online control mode: you can remotely control relay operations through the UbiBot cloud platform, including opening/closing the relay, the overall synchronization or independent single-point control, timing and cycle setup, delaying tasks or defining trigger conditions through early warning rules and automation control.
  2. Pules on/off mode: Pulse ON, i.e., when the relay is in closed state, the relay can be set to disconnect for a period of time (set parameter0.1s) and then close automatically. Pulse OFF, i.e., when the relay is in discon-nected state, the relay can be set to close for a period of time (set parameter0.1s) and then disconnect automatically.
  3. Local linkage mode: The device has 4 optocoupler inputs, which can be directly linked with the relay. It means that when the optocoupler input signal is effective, the corresponding relay will absorb/disconnect/no action; when the optocoupler input signal is canceled, the corresponding relay will disconnect/absorb/no action. The corresponding relationship between the optocoupler input and the relay’s absorption/disconnec-tion/non-activation can be set through the PC tools or the UbiBot platform.
  4. Offline control mode: The NR1 device supports the Modbus RTU protocol, allowing for offline control of 4-channel relays through an RS485 connection to a computer.
  5. Safety interlock mode: The device supports safety interlock setting. if any of the relays set for safety interlocking is turned on, the other relays will be turned off.

DEVICE SPECIFICATION

FAQ

  1. Device network configuration failure reasons

  2. Please check if the WiFi account password is correct;

  3. Please check whether the router is working properly and the network connection is normal;

  4. Please make sure the device has entered the WiFi configuration mode;

  5. Please check whether the WiFi band is 2.4GHz and the channel is between 1~13;

  6. Please check the WiFi channel width is set to 20MHz or auto mode;

  7. WiFi security type: NR1 supports OPEN, WEP and WPA/WPA2-personal;

  8. Poor signal strength, please check the WiFi or cell phone data traffic signal strength.

  9. Ethernet network* configuration failure reasons

  10. Please check whether the network cable is properly connected to the equipment;

  11. whether the network cable is intact;

  12. whether the connected network can access the Internet;
    If the above points are not abnormal, and you still cannot activate the device, you need to check whether the network environment allows DHCP (automatic IP allocation) devices to access the network; or re-scan the device QR code, select Ethernet access (advanced mode), and follow the APP prompts to manually assign IP to the device.

  13. Reasons for failure to send device data
    Check whether the router is working properly.

  14. Can the device be used in a network-free environment?
    The device can still work without network, and can be controlled in real time through the switch input or RS485 interface.
    For more frequently asked questions, please visit www.ubibot.com and go to the “Community and Documentation” page.

TECHNICAL SUPPORT
The UbiBot team is glad to hear your voice of our profucts and services.
For any questions or suggestions, please feel free to create a ticket in the UbiBot app. Our customer services representatives respond within 24 hours and often in less than an hour. You can also contact the local distribu-tors in your contry for localized service. Please go to our website to view their contacts.

PRODUCT MAINTENANCE INSTRUCTIONS

WARRANTY INFORMATION

  1. The warranty period for this product is one year from the date of purchase. The buyer is required to submit a valid proof of purchase. During the warranty period, free repair will be provided for any failure caused by the quality of the product under normal use. The mailing cost of the returned product is the responsibility of the sender (one way).
  2. The following cases are not covered by the warranty:
  3. the product is out of warranty;
  4. product failure or damage caused by incorrect or improper operation not in accordance with the product use instructions, configuration instructions, and product maintenance instructions;
  5. accidental or man-made damage to the product, such as exceeding the temperature and humidity range of the equipment, water-caused damage, including natural water, such as water vapor, etc., fall, abnormal physical force, deformation, cable breakage, etc.;
  6. damage due to natural wear and tear, consumption and aging, etc. (including shells, cables, etc.);
  7. failure or damage caused by unauthorized dismantling of the product without permission;
  8. failure or damage caused by force majeure, such as earthquake, fire, lightning strike, tsunami, etc.;
  9. other failure or damage caused unrelated to product design, technology, manufacturing or quality.

FCC

FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Note: The Grantee is not responsible for any changes or modifications not expressly approved by the party responsible for compliance. such modifications could void the user’s authority to operate the equipment. The device has been evaluated to meet general RF exposure requirement. To maintain compliance with FCC’s RF exposure guidelines, the distance must be at least 20 cm between the radiator and your body, and fully supported by the operating and installation configurations of the transmitter and its antenna(s).

IC Warning
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause
The device has been evaluated to meet general RF exposure requirement. To maintain compliance with RSS-102 — Radio Frequency (RF) Exposure guidelines, this equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals