GE APPLIANCES JVM3160RF, EF 1.6 cu ft Over the Range Microwave Oven Owner’s Manual
- August 14, 2024
- GE Appliances
Table of Contents
GE APPLIANCES JVM3160RF, EF 1.6 cu ft Over the Range Microwave Oven
Product Specifications
- Model : JVM3160RF/EF
- Power Requirement : 120V grounded outlet
- Ventilation Options : Hood exhaust duct, rear exhaust
- Exhaust Outlet : 3-1/4×10 duct
- Maximum Duct Length: 140 equivalent feet
Installation Information
- Mounting Height: 66 inches minimum from the floor
- Minimum Distance from Door Hinge Side to Adjacent Wall: 1/2 inch
- Width Required: 30 inches minimum
- Exhaust Connection: Rectangular duct of 3-1/4 x 10 size
Ventilation Options
- Outside ventilation requires a hood exhaust duct
- Rear or horizontal exhaust alignment is important for proper installation
- Use appropriate transitions and adaptors for different duct types
Features and Benefits
The microwave oven can be programmed automatically or manually for optimal
results.
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
For answers to your Monogram, GE Café™, GE Profile™ or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000.
NOTE : Requires 120V grounded outlet. Electrical receptacle must be located in cabinet above the microwave oven. No additional wiring, venting or cabinet rebuilding necessary in bmany cases. Complete detailed, easy-to-follow installation instructions and convenient full-size templates are packed with the microwave oven.
IMPORTANT INFORMATION: When installing the microwave oven over a range, allow a minimum of 2″ from bottom of a microwave oven to top of range backguard to allow for removal of light covers.
VENTILATION OPTIONS : The microwave ovens are designed for adaptation to the following three types of ventilation:
- Outside exhaust (vertical – as shown)
- Outside exhaust (horizontal)
- Recirculating (non-vented ductless – see Filter Kit drawing)
INSTALLATION INFORMATION: This information is not intended to be used for installing unit described. Before installing, consult installation instructions packed with product/kit for current dimensional data.
For answers to your Monogram, GE Café™, GE Profile™ or GE Appliances product questions, visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000
HOOD EXHAUST DUCT: Outside ventilation requires a HOOD
EXHAUST DUCT. Read the following carefully.
- EXHAUST CONNECTION: The hood exhaust has been designed to mate with a standard 3-1/4″ x 10″ rectangular duct. If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not use less than a 6″ diameter duct
- REAR EXHAUST: If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with space between studs, or wall should be prepared at the time it is constructed by leaving enough space between the wall studs to accommodate exhaust.
- MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length of 3-1/4″ x 10″ rectangular or 6″ diameter round duct should not exceed 140 equivalent feet.
- ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent length of all transitions and adaptors plus the lengths of all straight duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.
OPTIONAL ACCESSORIES (AVAILABLE AT ADDITIONAL COST)
FEATURES AND BENEFITS
- 1.6 cu. ft. capacity – 1000 Watts (IEC-705 test procedure)
- Convenience cooking controls – Operating made quick and easy
- Auto and time defrost – Defrosting times and power levels are programmed automatically or manually for optimal results
- Turntable on/off – Controls turntable operation
- Two-speed, 300-CFM venting system – Removes smoke, steam and odors
- Model JVM3160RFSS – Stainless steel/black
- Model JVM3160EFES – Slate
FAQ
Q: What type of ventilation options are available for this microwave
oven?
A: The microwave oven supports hood exhaust duct and rear exhaust options.
Q: What is the maximum duct length recommended for proper air movement?
A: The total duct length should not exceed 140 equivalent feet for
satisfactory air movement.
Q: Can a round duct be used with this microwave oven?
A: If a round duct is required, a rectangular-to-round transition adaptor must
be used.