Honeywell CS076AE Evaporative Air Cooler Instructions
- August 14, 2024
- Honeywell
Table of Contents
Honeywell CS076AE Evaporative Air Cooler
Specifications
- Product : Honeywell Evaporative Air Cooler
- Recommended Maximum Relative Humidity Level: 60% or less
- Indoor Use: Position in front of an open door or window for cross-ventilation
- Outdoor Use : Designed to IPX4 product standards
- Storage : Follow maintenance guidelines for cleaning and draining the water tank
Product Usage Instructions
Safety Rules:
- Read and save the Air Cooler Guide and User Manual before use. Follow basic safety precautions when using electrical appliances.
User Tips:
- The evaporative air cooling mechanism works by using honeycomb cooling media to cool warm air using water and a pump. Ensure humidity levels are 60% or less for optimal cooling.
Cooler Location:
- Indoors: Position the cooler in front of an open door or window for cross-ventilation. Note that it is not as efficient as a refrigerated air conditioner.
- Outdoors: For outdoor models, avoid placing the cooler outdoors during heavy rain or snow.
Storage and Maintenance Guidelines:
- Regularly clean the water tank by draining it once a week. Ensure the Air Cooler is switched off and unplugged before cleaning. Follow detailed instructions in the User Manual.
Troubleshooting Guide:
- Contact the Customer Service Center listed in the User Manual for assistance with troubleshooting.
FAQ
- Q: How often should I clean the water tank?
- A: It is recommended to drain and refill the water tank at least once a week to reduce mineral deposits and extend the life of the Honeycomb Cooling Media.
- Q: What should I do if there is an odor from the Honeycomb Cooling Media?
- A: The initial odor from the Honeycomb Cooling Media will dissipate after a few hours of use. If the odor persists, ensure proper ventilation and contact customer service if needed.
Portable Evaporative Air Cooler Safety & Maintenance Guide Users tips and safety instructions Read and save these instructions before use
THANK YOU
Congratulations on your purchase of this Honeywell Evaporative Air Cooler. The Safety & Maintenance Guide and the separate User Manual are intended to provide you with important information needed to set up, operate, maintain and troubleshoot this product.
SAFETY RULES
WARNING—READ AND SAVE THE AIR COOLER GUIDE AND USER MANUAL
The Air Cooler Guide and User Manual are intended to provide important
information needed to set up, operate, maintain and troubleshoot your Air
Cooler. Failure to follow these instructions may damage and/or impair its
operation, create hazards, and void the warranty. In case there is any
inconsistency or conflict between the English version and any other language
version of the content of this material, the English version shall prevail.
READ AND SAVE THESE INSTRUCTIONS:
When using electrical appliances, basic safety precautions should always be
followed:
- This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a
- safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be done by children without supervision.
- If the supply cord is damaged, it must be replaced with a supply cord that is as per the manufacturer’s specifications, by the authorized service center or its service agent or a similarly qualified person in order to avoid a hazard.
- Before operating the product, remove the packaging and check that the product is in good condition. DO NOT allow children to play with this appliance, packaging or plastic bags.
- Check the household voltage to ensure it matches the appliance’s rating specifications.
- DO NOT use an extension cord with this unit.
- Do not run cord under the carpeting. Do not cover the cord with throw rugs, runners, or similar coverings. Do not route cord under furniture or appliances. Arrange the cord away from the traffic area and where it will not be tripped over.
- Always ensure the water tank is filled with water above the “min.” level mark when operating the air cooler in evaporative COOLING mode.
- Always unplug the Air Cooler before refilling the water tank, cleaning, servicing or relocating the unit.
- Never pull the cord. Remove it from the electrical outlet/ socket by grasping and pulling on the plug-end of the cord.
- This appliance has been manufactured for use in domestic environments and must not be used for other purposes.
- DO NOT use in areas where gasoline, paint or other flammable goods and objects are stored. When using the COOL setting, make sure the water tank is at the Min Indicator Level. Operating the unit on the COOL setting with an empty tank may result in damage to the water pump.
- DO NOT attempt to repair or adjust any electrical or mechanical functions of the Air Cooler, as this may void the warranty.
- DO NOT cover the cooler’s air inlet or outlet, as this may damage the motor.
- DO NOT insert or allow objects to enter any ventilation or exhaust opening, as this may damage the unit and may cause electrical shock or fire.
- DO NOT operate with the Honeycomb Cooling Media removed, as this will overload and damage the motor.
- DO NOT leave the operating appliance unattended for an extended period of time.
- DO NOT continue to operate the unit if it is damaged or if it malfunctions. Refer to the TROUBLESHOOTING section and contact the CUSTOMER SUPPORT CENTER. Always place the unit on a dry-level floor.
- DO NOT use in bathrooms or near water. DO NOT keep the product where it may fall into a water container.
- Store in a dry area when not in use.
- Always grip the side handles to move the Air Cooler.
- This appliance is not intended for use by persons (including children) with reduced physical,
- sensory, or mental capabilities, or lack of experience and knowledge unless they have been given
- supervision or instruction concerning the use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- WARNING: To reduce the risk of fire or electric shock, do not use this appliance with any solid-state speed control device.
- Unplug the appliance during filling and cleaning.
- Be aware that high humidity levels may encourage the growth of biological organisms in the environment.
- Do not permit the area around the humidifier to become damp or wet. If dampness occurs, turn the output of the humidifier down. If the humidifier output volume cannot be turned down, use the humidifier intermittently. Do not allow absorbent materials, such as carpeting, curtains, drapes, or tablecloths, to become damp.
- Never leave water in the reservoir when the appliance is not in use.
- Empty and clean the humidifier before storage. Clean the humidifier before the next use.
- Keep the appliance out of the reach of children. Steam and boiling water may cause burns.
- WARNING: To reduce the risk of fire, electric shock or injury to persons, do not use replacement
- parts that have not been recommended by the manufacturer (e.g. parts made at home using a 3D printer).
- The appliance is only to be used with the power supply unit provided with the appliance.
USER TIPS
What is Evaporative Cooling?
Honeywell Evaporative Air Coolers are built to maximize energy efficiency and
keep energy costs low. Warm air is drawn into the cooler and enters the
Honeycomb Cooling Media. Water pumped from the water tank pours over the
Honeycomb Cooling Media. As the warm air passes through the Honeycomb Cooling
Media, the water absorbs the heat, naturally cooling and humidifying the air.
A fan propels the cooled air out into the room. This no-compressor system
cools naturally, efficiently and inexpensively.
Evaporative Air Cooling Mechanism
The recommended maximum relative humidity level is 60% or less, which allows a noticeable temperature decrease. The temperature will be lower in drier climates because higher evaporation occurs when the humidity is low.
NOTE
When the product is used for the first time the Honeycomb Cooling Media will have an odor which will dissipate in a few hours or so of initial use.
COOLER LOCATION
To maximize efficiency, position the Air Cooler according to the following
guidelines:
Indoors
Place the cooler in front of an open door or window. Ensure that there is
adequate cross-ventilation in the room by leaving a door or window open
opposite the cooler. The Evaporative Air Cooler should not be used in enclosed
spaces. It must be kept level and there must be water in the water tank. Doors
and windows should be opened to allow free airflow. The Evaporative Air Cooler
works best when placed near an open window, so that outside air is drawn into
the Evaporative Air Cooler, circulates in the room, then exits via the door.
The maximum cooling effect is felt when a person is near the flow of air
coming out of the Evaporative Air Cooler. The Evaporative Air Cooler produces
moisture and can be used to humidify dry air. To be used for humidification
the windows and doors should be closed.
IMPORTANT: The evaporative air cooler is not an air conditioner as it does not use a compressor or refrigerant gas. It should not be expected to cool as efficiently as a refrigerated air conditioner. Outdoors (for outdoor models only)
- Use only on GFCI-protected outlets/ sockets (for USA only). Press the TEST button (then the RESET button) every month to ensure proper operation.
- Power cords must be secured to avoid tripping.
- The wiring and connections must be protected from water. The electrical plug and Air Cooler connections must be dry at all times. When used outdoors, insert the air cooler electrical plug into an IP44 compliant outdoor electrical outlet.
- Set the unit on a solid flat surface.
IMPORTANT: Honeywell Outdoor Air Cooler models are designed to IPX4 product standards and not recommended to be placed outdoors during heavy rain or snow.
STORAGE AND MAINTENANCE GUIDELINES
Read the detailed CLEANING & DRAINING THE WATER TANK instructions for your Air
Cooler, located in the separate User Manual. Below is a general guideline for
maintenance and storage of your Air Cooler.
WARNING : Always switch OFF the Air Cooler and unplug it from the
electrical source before cleaning or maintenance.
Cleaning
At least once a week, drain the water tank completely and refill it with fresh
water. Doing this will greatly reduce mineral deposits and help to extend the
life of the Honeycomb Cooling Media.
End of Season Storage
If the Air Cooler will not be used for a long time:
- Make sure all parts are dry by running the Fan Only mode for about 1 to 2 hours before storing (time depends on ambient humidity conditions).
- Switch OFF the Air Cooler and unplug from the power supply.
- Empty/drain all the water from the tank. Note: If the unit is connected to a continuous water supply, you must switch off the water supply and remove the drain tube before draining the water tank. This function is only available on some Honeywell Air Cooler
- models. Check the User Manual to see if your unit has the Continuous Water Supply Function.
- Clean the water tank with a damp cloth to wipe away any dust or mineral deposits.
- Remove the Honeycomb Cooling Media and Carbon Dust Filter* from the Air Cooler and rinse under fresh water to remove dust and dirt.
- Replace the Honeycomb Cooling Media and Carbon Dust Filter* after they are clean and dry.
- To protect the unit from dust, moisture, and scratches, cover with a clean cloth, tarp or plastic bag before storing.
- Coil the power cord and store it away from the floor to protect it.
- Store this unit at room temperature in a dry location, away from direct sunlight and/or very hot, cold or damp environments.
Carbon Dust Filter is available in specific models of Honeywell Air Coolers only. Check the User Manual for your model to see if it includes a Carbon Dust Filter.
TROUBLESHOOTING GUIDE
Customer Service Center: See the last page of the User Manual to find the contact details for the Customer Service Center for your area.
PROBLEM | POSSIBLE CAUSE | SOLUTION |
---|
No discharge of air.
|
The cord is not plugged in.
| Make sure the power cord is plugged in and the switch is ON.
The power is not ON.
| Turn the unit ON by pressing the power button on the control panel / remote control or turn the SPEED knob.
Not Cooling / Unit is making noise.
|
The pump is not turned ON.
|
Turn on the COOL function from remote or control panel.
Low or no water in the tank, when COOL is selected.
|
Refill water tank.
Damaged Pump or Calcium deposits on the blower.|
Contact Customer Service Center.
Excessive humidity in the room.
|
In cooling mode, the Air Cooler produces moisture as a result of evaporative cooling. This is normal.
|
The Air Cooler cools best in dry climates. If the ambient humidity level is high (approx. 75% or above), refrain from using the Air Cooler until ambient humidity is reduced.
Make sure the window/doors are open and there is adequate cross-ventilation in the room so that
the moisturized air can circulate better. Do not use the evaporative cooling function on days with high ambient humidity.
Odors.
|
When the Cooler is new.
| When the unit is used for the first time, the Honeycomb Cooling Media will have an odor, which will dissipate within a few hours of initial use.
Algae or mold due to moist parts. In very damp conditions, algae may form.
|
Check the Honeycomb Cooling Media. If you see mold spots on the media or suspect an algae issue, remove and replace the Honeycomb Cooling Media. Contact the Customer Service Center for more information.
PROBLEM | POSSIBLE CAUSE | SOLUTION |
---|
Remote control does not work.
| ****
Remote control batteries are old & used or inserted incorrectly in the battery compartment.
| ****
Replace with new batteries. Follow the polarity guide inside the battery compartment.
Damaged remote control.
| ****
If replacing new batteries in the correct position does not work, contact the Customer Service Center.
The unit does not
respond.
| ****
Damaged Control Panel on the unit.
| ****
Try to activate the unit with the Remote Control. If the unit responds, then the Control Panel on the unit may be experiencing problems – contact the Customer Service Center.
If neither the Remote Control or the Control Panel is working, contact the Customer Service Center.
The outdoor Air Cooler is wet from rain.
| ****
The Air Cooler was placed outdoors (this is only allowed for outdoor Air Cooler models) and soaked by heavy rain.
| ****
A small amount of rain on the unit is not a problem as long as the electrical plug and outlet are dry. If they are wet, DO NOT touch the unit or electrical plug/ outlet. Switch off the master power for the outlet before unplugging the unit from the electrical outlet. Make sure all outlets and plugs are dry before use.
The Air Cooler is designed to IPX4 product standards and is not recommended to be placed outdoors
during heavy rain conditions. Do not operate the Air Cooler when wet. Wait for the Air Cooler to dry before plugging in and turning on the unit again.
The batteries contain materials, which are hazardous to the environment; they must be removed from the appliance before it is scraped and that they are disposed of safely.
Correct Disposal of this product.
This marking indicates that this product should not be disposed of with other
household wastes throughout the EU. To prevent possible harm to th environment
or human health from uncontrolled waste disposal. recycle it responsibly to
promote the sustainable reuse of material resources. To return your used
device, please use the return and collection systems or contact the retailer
where the product was purchased. They can take this product for
environmentally safe recycling
CONTACT
- Keizersgracht 62
- 1015 CS Amsterdam
- Netherlands
- Tel: +31 20 5207422
- Support.eu@jmatek.com
Made in China
© 2024 JMATEK Limited. All rights reserved. The Honeywell Trademark is used
under license from Honeywell International Inc. Honeywell International Inc.
makes no representations or warranties with respect to this product. This
product is manufactured by Airtek Int’l Corp. Ltd. (a subsidiary of JMATEK
Ltd.).
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>