8 Gallon Quiet Compr essor
Operating Instructions and Parts Manual Model: DC080500
© 2016 Campbell Hausfeld
A Marmon/Berkshire Hathaway Company
GETTING STARTED
BEFORE YOU BEGIN
Description
Thank you for purchasing this Campbell Hausfeld quiet, oilless compressor .
For over 100 years, we have manufactured products that are durable, reliable
and just easy to use and maintain. Portable oilless air compressors are for
home and workshop use. Cleaning or replacement of the inlet filter on all
models and draining moisture from the air receivers are required maintenance.
UNPACKING
CAUTION
Do not li ft or move unit without appropriately rated equipment. Be sure the
unit is securely attached to li fting device used. Do not li ft unit by
holding onto tubes or coolers. Do not use unit to li ft other attached
equipment.
After unpacking the unit, inspect carefully for any damage that may have
occurred during transit. Check for loose, missing or damaged parts. Check to
be sure all supplied accessories are enclosed with the unit. In case of
questions, damaged or missing parts, please visit www .campbellhausfeld.com
for customer assistance.
WARNING
Do not operate unit i f damaged during shipping, handling or use. Damage may
result in bursting and cause injury or property damage.
SAFETY / SPECIFICATIONS
GENERAL SAFETY INSTRUCTIONS
Overview of Safety Warning System and Your Responsibilites
READ THIS MANUAL BEFORE USING THIS PRODUCT. FAILURE TO FOLLOW THE INSTRUCTIONS
AND SAFETY PRECAUTIONS IN THIS MANUAL CAN RESULT IN SERIOUS INJURY OR DEA TH.
KEEP THIS MANUAL FOR FUTURE REFERENCE.
Your safety and the safety of others depend on you thoroughly reading and
understanding this manual. If you have questions or do not understand the
information presented in this manual, please visit
www.campbellhausfeld.com.
This is the safety alert symbol. It is used to alert you to potential personal
injury hazards. The meaning of this safety alert symbol is as follows:
Attention! Become Alert! Your Safety may be at Risk. The message that appears
next to the warning which can be either written or pictorially presented.
Operations that may cause product damage are identi fied by the signal word
“NOTICE” in this manual.
Most tool-related incidents are caused by failure to observe basic safety
rules or precautions. Y ou must be alert to potential hazards. You must have
the necessary training, skills and tools to perform these functions.
Campbell Hausfeld cannot anticipate every possible circumstance that might
involve a potential hazard.
Therefore , the warnings in this manual are not all inclusive. If a tool,
procedure, work method or operating technique that is not speci fically
recommended by Campbell Hausfeld is used, you must satisfy yourself that it is
safe for you and for others. You should also ensure that the product will not
be damaged or be made unsafe by the operation, lubrication, maintenance or
repair procedures that you choose.
This manual contains information that is very important to know and
understand. This information is provided for SAFETY and to PREVENT EQUIPMENT
PROBLEMS. To help recognize this information, observe the following symbols.
Safety Guidelines
DANGER
Danger indicates an imminently hazardous situation which, if not avoided, WILL
result in death or serious injury.
WARNING
Warning indicates a potentially hazardous situation which, if not avoided,
COULD result in death or serious injury.
CAUTION
Caution indicates a potentially hazardous situation which, if not avoided, MA
Y result in minor or moderate injury.
NOTICE
Notice indicates important information, that i f not followed, may cause
damage to equipment.
IMPORTANT or NOTE: Information that requires special attention.
The following Safety Symbols appear throughout this manual to alert you to
important safety hazards and precautions.
Safety Symbols California Proposition 65
WARNING
This product or its power cord may contain chemicals known to the State of
Cali fornia to cause cancer and birth defects or other reproductive harm. W
ash hands after handling.
WARNING
You can create dust when you cut, sand, drill or grind materials such as
wood, paint, metal, concrete, cement, or other masonry. This dust often
contains chemicals known to cause cancer , birth defects, or other
reproductive harm. Wear protective gear.
Important Safety Information
Please read and save these instructions. Read carefully before attempting to
assemble, install, operate or maintain the product described. Protect yoursel
f and others by observing all safety information. Failure to comply with
instructions could result in personal injury and/or property damage! Retain
instructions for future reference.
This manual contains important safety, operational and maintenance
information. If you have any questions, please visit www .campbellhausfeld.com
for customer assistance.
Since the air compressor and other components used (material pump, spray guns,
filters, lubricators, hoses, etc.) make up a high pressure pumping system, the
following safety precautions must be observed at all times:
-
Read all manuals included with this product carefully. Be thoroughly familiar with the controls and the proper use of the equipment.
-
Follow all local electrical and safety codes as well as in the United States, the National Electrical Codes (NEC) and Occupational Safety and Health Act (OSHA).
-
Only persons well acquainted with these rules of safe operation should be allowed to use the compressor.
-
Keep visitors away and keep out of reach of children.
-
Wear safety glasses and use hearing protection when operating the unit.
-
Do not stand on or use the unit as a handhold.
-
Before each use, inspect compressed air system and electrical components for signs of damage, deterioration, weakness or leakage. Repair or replace defective items before using.
-
Check all fasteners at frequent intervals for proper tightness.
WARNING
Motors, electrical equipment and controls can cause electrical arcs that will ignite a flammable gas or vapor . Never operate or repair in or near a flammable gas or vapor . Never store flammable liquids or gases in the vicinity of the compressor.
WARNING
WARNING: Do not operate with guard removed.
WARNING
WARNING: Risk of electric shock. Use GFCI. Use indoors only. Disconnect all connections before servicing. -
Do not wear loose clothing or jewelry that will get caught in the moving parts of the unit.
CAUTION
Compressor parts may be hot even i f the unit is stopped. -
Keep fingers away from a running compressor; fast moving and hot parts will cause injury and/or burns.
-
If the equipment should start to vibrate abnormally, STOP the engine/motor and check immediately for the cause. Vibration is generally a warning of trouble.
-
To reduce fire hazard, keep engine/motor exterior free of oil, solvent, or excessive grease.
WARNING
An ASME code safety relief valve with a setting no higher than the maximum allowable working pressure (MA WP) MUST be installed in the tank for this compressor. The ASME safety valve must have suf ficient flow and pressure ratings to protect the pressurized components from bursting.
CAUTION
See compressor speci fication decal for maximum operating pressure. Do not operate with pressure switch or pilot valves set higher than the maximum operating pressure. -
Never attempt to adjust ASME safety valve. Keep safety valve free from paint and other accumulations.
WARNING
NEVER use plastic (PVC, ABS, or CPVC) pipe for compressed air .
DANGER
WARNING: Risk of bursting. If air tank develops a leak, replace the air tank immediately. Never repair , weld, or modi fy the air tank or attachments. Never make adjustments to the factory set pressures. Never exceed manufacturer’ s maximum allowable pressure rating of attachements.
NOTICE
Drain liquid from tank daily. -
Tanks rust from moisture build-up, which weakens the tank. Make sure to drain tank regularly and inspect periodically for unsafe conditions such as rust formation and corrosion.
-
Fast moving air will stir up dust and debris which may be harmful. Release air slowly when draining moisture or depressurizing the compressor system.
WARNING
WARNING: Serious injury or death oculd occur from inhaling compressed air. Never inhale air from the air compressor either directly or from a breathing device connected to the air compressor. The air stream may contain carbon monoxide, toxic vapors or sold particles.
Do not spray flammable materials in vicinity of open flame or near ignition sources including the compressor unit.
Spraying Pr ecautions
WARNING
WARNING: Risk of fire and explosion. When a combustible liquid is sprayed there can be danger of fire or explosion, especially in a closed area. Keep the compressor/motor at least 6 meters (18 feet) away from explosive vapors. -
DO NOT spray flammable materials in vicinity of open flame or near ignition sources including the compressor unit. Keep away from heat, sparks and flame.
-
DO NOT smoke. Extinguish all flames and pilot lights and turn of f stoves, heaters, electric motors, and other sources of ignition during use and until all vapors are gone.
-
Prevent build-up of vapors by opening all windows and doors to achieve cross-ventilation. Use only with adequate ventilation.
-
Do not breathe dust, vapors, or spray mist. Ensure fresh air entry during application and drying. If you experience eye watering, headache or dizziness, wear respiratory protection (NIOSH approved orequivalent) or leave the area.
-
Follow OSHA and CSA safety regulations for personal protective equipment. T ypical equipment may include safety glasses, respirator , and/or work gloves and is dependent upon the application type, amount of use and workspace.
SPECIFICATIONS
| DC080500
---|---
Motor HP| 1
Tank Capacity| 8 gallon
Phase| Single
Number of Cylinders| 2
Air Delivery @ 90 psi| 2.4 SCFM
Voltage| 110 – 120
Amperes| 7
Hertz (Cycles)| 60
Maximum Pressure| 125 psi
RPM| 1750
T ank Outlet Size| 1/4 in. IM Quick Connect
Unit Weight| 61.94 pounds
DIMENSIONS
| DC080500
---|---
Length| 33.85 in.
Width| 13.39 in.
Height| 22.83 in.
GETTING TO KNOW YOUR COMPRESSOR
PSI (Pounds per Square Inch) – Measurement of the pressure exerted by the
force of the air. The actual psi output is measured by a pressure gauge on the
compressor.
SCFM (Standard Cubic Feet per Minute) – Sometimes called CFM (Cubic Feet
per Minute). Measurement of air volume delivered by the compressor.
Air Delivery – A combination of psi and SCFM. The air delivery required
by a tool is stated as (number) SCFM at (number) psi. The combination of these
figures determines what size unit is needed.
Air Tank Capacity – The volume of air stored in the tank and available
for immediate use. A large tank allows the intermittent use of an air tool
with an air requirement higher than the compressor’ s rated delivery.
Amps or Amperage – A measure of the electrical force minus the resistance
on an electrical line. This air compressor requires 15 amps for operation. Be
sure the compressor will operate on an electrical line with the proper amps.
If other appliances operate on the same line, they will reduce the available
amps. If the amperage is not adequate, the result will be blown fuses or
tripped circuits.
V olts or V oltage – A measurement of the force of an electrical current.
Cut-in / Cut-of f Pressure – Specific psi at which a compressor starts
and stops while refilling the air tank.
Pressure Switch – Auto On/Of f Switch – In the “Auto On” position, the
compressor shuts of f automatically when tank pressure reaches the maximum
preset pressure. After air is used from the tank and drops to a preset low
level, the pressure switch automatically turns the motor back on. In the “Of
f” position, the compressor will not operate. This switch should be in the “Of
f” position when connecting or disconnecting the power cord from the
electrical outlet. (Figure 2) When the pressure switch turns the motor of f
you will hear air leaking out of the pressure switch unloader valve for a
short time. This releases the air pressure from the discharge tube and allows
the compressor to restart easier.
Regulator – The regulator controls the amount of air pressure at the hose
outlet. Turning regulator knob clockwise (to the right) will increase air
pressure at the outlet. Turning knob counterclockwise (to the teft) will lower
air pressure to the outlet. Turning knob fully counterclockwise will shut off
flow of air completely.
Handle – Designed to move the compressor.
ASME Safety Valve – This valve automatically releases air if the tank
pressure exceeds the preset maximum.
Exhaust Tube – This tube carries compressed air from the pump to the
check valve. This tube becomes very hot during use. To avoid the risk of
severe burns, never touch the exhaust tube.
Check Valve – One-way valve that allows air to enter the tank, but
prevents air in the tank from flowing back into the compressor pump.
Air Outlet – A quick connect coupler designed to work in combination with
a quick connect plug to quickly and easily join the compressor to an air hose.
Pressure Gauges – These gauges will show air pressure in the compressor
tank and at the compressor outlet.
Outlet Pressure Gauge – Will show air pressure at the outlet in pounds
per square inch (psi). Make sure this gauge reads ZERO (by adjusting regulator
knob fully counterclockwise) before changing air tools or disconnecting air
hose from outlet.
Tank Pressure Gauge – Will show air pressure in tank while the compressor
is running, indicating compressor is building pressure properly. This gauge
will show maximum pressure of compressor when it shuts off automatically at
the pressure switch.
Drain Valve – This vatve is located underneath the tank. Use this valve
to drain moisture from the tank daily to reduce the risk of corrosion.
CAUTION
Drain liquid from tank daily.
Reduce tank pressure below 10 psi, then drain moisture from tank daily to
avoid tank corrosion. Drain moisture from tank by opening the drain valve
located underneath the tank.
MOTOR SPECIFICATIONS AND ELECTRICAL REQUIREMENTS
Power Supply and Motor Specifications
NOTICE To reduce the risk of electrical hazards, fire hazards or damage
to the tool, use proper circuit protection.
NOTICE Your tool is wired at the factory for operation using the voltage
shown. Connect tool to a power fine with the appropriate voltage and a 15-amp
branch circuit. Use a 15-amp time delay type fuse or circuit breaker.
NOTICE To reduce the risk of shock or fire, if power cord is worn or cut,
or damaged in any way, have it replaced immediately.
The A-C motor used on this compressor is a permanent split capacitor non-
reversible induction type, having the following specifications. It is wired at
the factory for operation on 110V-120V AC, 60 Hz service.
MOTOR SPECIFICATIONS
Voltage | 110 – 120 |
---|---|
Amperes | 7 |
Hertz (Cycles) | 60 |
Phase | Single |
RPM | 1750 |
General Electrical Connections
WARNING
WARNING: Risk of electric shock. Use GFCI. Use indoors only. Disconnect all
connections before servicing. Use identical replacement parts. Servicing must
be performed by a licensed, qualified electrician.
In the event of a mal function or breakdown, grounding provides a path of
least resistance for electrical current to reduce the risk of electric shock.
This compressor is equipped with an electric cord having an equipment-
grounding conductor and a grounding plug, as shown. The plug must be plugged
into a matching outlet that is properly installed and grounded in accordance
with all local codes and ordinances. Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. The conductor with
insulation having an outer surface that is green with or without yellow
stripes is the equipment-grounding conductor . If repair or replacement of the
electric cord or plug is necessary, do not connect the equipment-grounding
conductor to a live terminal.
If the grounding instructions are not completely understood, or if you are in
doubt as to whether the compressor is properly grounded check with a quali
fied electrician or service personnel.
Grounding Instructions
-
This product is for use on a nominal 120 v circuit. It must be grounded. In the event of an electric short circuit, grounding reduces the risk of electrical shock by providing an escape wire for the electric current. Unit is equipped with a cord that has a grounding prong. It will fit one of the common outlet types shown in Figure 3. If plug will not fit in the desired outlet, have the plug or the outlet replaced by a quali fied electrician. WARNING
WARNING: Risk of electric shock.
Improper use of grounding plug can result in a risk of electrical shock. Plug must be plugged into an outlet that is properly installed and grounded in accordance with local codes and ordinances
NOTICE : Do not use grounding adapter. -
Always check with a qualified electrician or serviceman if the grounding instructions are not completely understood, or if in doubt as to whether the product is properly grounded. Do not modify the plug provided; if it will not fit the outlet, have the proper outlet installed by a qualified electrician.
-
Use only a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that accepts the plug on the product. Make sure your extension cord is not damaged. When using an extension cord, be sure to use one heavy enough to carry the current your product draws. For lengths less than 25ft. 16-3 A WG extension cords shall be used. An undersized cord results in a drop in the voltage and loss of power and overheating. (NOTICE: Table 1 shows the correct size to use depending on cord length. When in doubt, use the next heavier gauge. The smaller the gauge number , the heavier the cord.)
-
Use of an extension cord may cause excess heat to motor. This could lead to tripped breaker (at electrical panel) or tripped thermal overload (on compressor motor). If this occurs, eliminate extension cord and plug compressor directly into electrical outlet. A void using extension cords; use longer air hose(s) instead.
If repair or replacement of the cord or plug is necessary, do not connect the
grounding wire to either flat blade terminal.
The wire with insulation having an outer surface that is green with or without
yellow stripes is the grounding wire.
MOTOR SPECIFICATIONS AND ELECTRICAL REQUIREMENTS (CONTINUED)
- The air compressor should be located where it can be directly plugged into an outlet. Although extension cord is not recommended, i f you must use only a 3 wire extension cord that has a 3 blade grounding plug and a 3 slot receptacle that accepts the plug on the product. When using an extension cord be sure to use one heavy enough to carry the current the product draws.
- To avoid loss of power and overheating, additional air hose must be used to reach work area instead of extension cords.
AMP RATING RANGE
VOLTAGE | CORD LENGTH IN FEET |
---|---|
120V | 25 ft |
12- 14 | 16 |
110-120 volt, 60Hz Information
The plug supplied on your compressor may not fit into the outlet you are
planning to use. Your local electrical code may require slightly different
power cord plug connections. If these differences exist refer to and make the
proper adjustments per your local code before your compressor is plugged in
and turned on.
Plugs and Receptacles
- If the plug on the electrical cord of the unit is unfamiliar to you or will not fit your particular receptacle, Figure 2 will help you understand why by illustrating the different plugs and the voltages they are to be used with.
- Make sure that the product is connected to an outlet having the same configuration as the plug.
- The receptacles must be connected to circuits rated to carry at least the voltage and amperages shown.
- NEVER have a receptacle replaced with one of a higher amperage before determining the change can be made according to all electrical codes affecting your particular area. The installation should be made by a qualified electrician. if the products must be reconnected for use on different types of circuits, the re-connection should be made by qualified personnel.
WARNING Overheating, short circuiting and fire damage will result from
inadequate wiring.
Electrical Installation
WARNING
All wiring and electrical connections should be performed by a qualified
electrician. installation must be in accordance with local codes and national
electrical codes.
Wiring
- Local electrical wiring codes differ from area to area. Source wiring, plug and protector must be rated for at least the amperage and voltage indicated on motor nameplate, and meet all electrical codes for this minimum.
- Use a slow blow fuse or a circuit breaker.
- This product is for use on a nominal 120 volt circuit and has a grounding plug that looks like the plug illustrated in Figure 3.
Make sure the product is connected to an outlet having the same configuration
as the plug. This product must be grounded. In the event of an electrical
short circuit, grounding reduces risk of electrical shock by providing an
escape wire for electric current. This product is equipped with a cord having
a grounding wire with an appropriate grounding plug. Plug must be plugged into
an outlet that is properly installed and grounded in accordance with all local
codes and ordinances.
CAUTION Overheating, short circuiting and fire damage will result from
inadequate wiring.
Do not modify the plug provided. If it will not fit the outlet, have the
proper outlet installed by a qualified electrician.
CAUTION if not properly grounded, this too! can cause an electrical
shock, particularly when used in damp locations, in proximity of plumbing,
outdoors.
DANGER Do not use a grounding adapter with this product!
All wiring and electrical connections should be performed by a qualified
electrician. installation must be in accordance with local codes and national
electrical codes.
WARNING improper installation of grounding plug is able to result in a
risk of electric shock. When repair or replacement of the cord or plug is
required, do not connect the grounding wire to either flat blade terminal. The
wire with insulation having an outer surface that is green with or without
yellow stripes is the grounding wire.
WARNING Never connect green (or green and yellow) wire to a live
terminal.
CAUTION overheating, short circuiting and fire damage will result from
inadequate wiring, etc.
Thermal Overload Protector
This compressor has an automatic thermal protector that shuts off the motor if
it overheats or has too much current. This protector is a “trip and hold”
protector. To reset, unplug the compressor and allow it to completely cool.
This should allow the automatic overload to reset. The protector may not reset
unless it is unplugged.
The motor must be allowed to cool down before start-up is possible. The motor
may automatically restart without warning if left plugged into the electrical
outiet, and the motor is turned on.
ASSEMBLY /INSTALLATION
- Check and tighten all bolts, fittings, etc, before operating compressor.
- Operate compressor in a ventilated area so that compressor may be properly cooled.
- Compressor should be located where it can be directly plugged into an outlet. Oo not use extension cords with this unit.
- To avoid loss of power and overheating, it is better to use additional air hose instead of extension cords to reach work area.
OPERATION
Before first start-up
Break-in procedure
Complete this procedure before using compressor for the first time. Once
completed, it is not necessary to repeat.
- Turn ON/OFF switch to OFF position.
- Open the tank drain valve.
- Plug in power cord.
- Turn ON/OFF switch to ON position and run compressor for 30 minutes.
- Turn ON/OFF switch to OFF position.
- Unplug power cord.
- Close drain valve.
The compressor is now ready for use.
Before Each Start-up
Operating Procedure
-
Turn regulator knob fully counter clockwise (to the left) to close air flow.
-
Connect air hose to outlet of regulator .
-
T urn ON/OFF Switch to OFF position.
-
Plug in power cord.
-
Turn ON/OFF Switch to ON position and let compressor run until it reaches automatic shutoff pressure.
-
Attach tire chuck or tool to end of hose.
-
Adjust regulator to proper pressure for tool or tire. Operate tool per instructions.
As air is depleted from the tank by use of a tire chuck, tool, etc., the compressor will restart automatically at its preset “cut-in” pressure. When a tool is being used continuously, the compressor will cycle on and of f automatically. -
Turn switch to OFF position, unplug power cord and drain tank.
MAINTENANCE
WARNING
Disconnect power source then release all pressure from the system before
attempting to install, service, relocate or perform any maintenance. Service
should be performed by an authorized service representative.
The compressor should be checked often for any visible problems and the
following maintenance procedures should be performed each time the compressor
is used.
WARNING
WARNING: Wear safety glasses. Check the safety valve by performing the
following steps:
ASME Safety Valve
- Turn the air compressor on and allow the tank to fill. The compressor will shut of f when the pressure reaches the preset maximum.
- Turn the air compressor off.
- Pull the ring on the safety valve to release the air for several seconds. ALWAYS use your hand to deflect fast-moving air past your face.
- Release the ring. Air will stop escaping when the ring is released at approximately 40 psi – 60 psi.
- If air leaks after the ring has been released, or if the valve is stuck and cannotbe actuarted buthering, remove the unit from service. DO NOT use the air compressor until the safety valve has been replaced. Use of the air compressor in this condition could result in death or serious bodily injury.
WARNING
Safety valve must be replaced if it cannot be actuated or it leaks air after ring is released.
Drain Tank
With compressor shut of f and pressure released:
Drain moisture from tanks by opening drain valve underneath tanks (See Figure
5).
Cleaning
Turn power OFF and clean dust and dirt from motor, tank, air lines and pump
cooling fins.
IMPORTANT: Unit should be located as far from spraying area as hose will
allow to prevent over-spray from clogging air filter.
Air Filter
Check air filter to be sure it is clean. To service a filter, remove the
filter housing cover. Remove filter and clean foam or filter in hot, soapy
water (Paper filters cannot be washed). Rinse and let dry. Replace air filters
that cannot be cleaned. Place filter back in the housing base. Replace cover.
Lubrication
This is an oilless type compressor requiring no lubrication.
End of Operation/Storage
- Turn Auto ON/OFF switch to OFF position.
- Unplug power cord from wall outlet and wrap around handle to prevent damage when not in use.
- Wearing safety glasses drain tank of air by pulling the ring on the safety valve. Use other hand to deflect fast moving air from being directed toward your face.
- Drain tank of condensation by opening drain valve on bottom of tank. Tank pressure should be below 10 psi when draining tank.
- Air hose should be disconnected from compressor and open end hanging down to drain condensation.
- Compressor and hose should be stored in a cool, dry place.
Technical Service
For information regarding the operation or repair of this product, please
call 1-800-543-6400.
MAINTENANCE SCHEDULE
Operation | Daily | Weekly |
---|---|---|
Drain Tank | ● | |
Check Air Filter | ● | |
Check Safety Valve | ● | |
Blow Dirt from Inside Motor | ● |
TROUBLESHOOTING GUIDE
SYMPTOM | POSSIBLE CAUSE(S) | CORRECTIVE ACTION |
---|---|---|
Compressor will not run | 1. Unit is plugged into extension cord |
2. No electrical power
3. Blown fuse
4. Breaker open
5. Thermal overload open
6. Pressure switch defective
7. Shorted or open motor winding| 1. Remove extension cord or use larger
gauge
extension cord
2. Turn on pressure switch? Plugged in? Check fuse/
breaker or motor overload
3. Replace blown fuse
4. Reset, determining why problem happened
5. Unplug and allow motor to cool before trying to
restart
6. Replace
7. Replace motor
Motor hums but cannot run or runs slowly| 1. Low voltage
2. Unit is plugged into extension cord
3. Shorted or open motor winding
4. Defective check valve or unloader| 1. Check with voltmeter
2. Remove extension cord or use larger gauge extension cord
3. Replace motor
4. Replace or repair
Fuses blow/circuit breaker trips repeatedly| 1. Incorrect size fuse, circuit
overloaded
2. Unit is plugged into extension cord
3. Defective check valve or unloader| 1. Check for proper fuse, use time-
delay fuse.
Disconnect other electrical appliances from circuit or
operate compressor on its own branch circuit
2. Remove extension cord or use larger gauge extension cord
3. Replace or repair
Thermal overload protector cuts out repeatedly| 1. Low voltage
2. Clogged air filter
3. Lack of proper ventilation/room temperature too high
4. Unit is plugged into extension cord| 1. Check with voltmeter
2. Clean filter (see Maintenance section)
3. Move compressor to well ventilated area
4. Remove extension cord or use larger gauge extension cord
Air tank pressure drops when compressor shuts off| 1. Loose connections
(fittings, tubing, etc.)
2. Loose drain valve
3. Check valve leaking
4. Check tank for cracks or pin holes| 1. Check all connections with soap
and water solution
and tighten
2. Tighten
3. Disassemble check valve assembly, clean or replace
DANGER
Do not disassemble check valve with air in tank; bleed tank first.
4. Replace tank. Never repair a damaged tank.
Excessive moisture in discharge air| 1. Excessive water in air tank
2. High humidity| 1. Drain tank
2. Move to area of less humidity; use air line filter
Compressor runs continuously| 1. Defective pressure switch
2. Excessive air usage
3. Air leaks| 1. Replace switch
2. Decrease air usage; compressor not large enough for
a requirement
3. Check all connections with soap and water
Compressor vibrates| Loose mounting bolts| Tighten
Air output lower than normal| 1. Broken inlet valves
2. Intake filter dirty
3. Connections leaking| 1. Have authorized service representative repair
unit
2. Clean or replace intake filter
3. Tighten connections
REPAIR PARTS ILLUSTRA TION FOR DC080500
For Repair Parts,
visitwww.campbellhausfeld.com
24 hours a day – 365 days a year
Please provide following information:
– Model number
– Serial number (if any)
– Part description and number as shown in parts list
REPAIR PARTS LIST FOR DC080500
Ref. No. | Description | Part Number: | Qty. |
---|---|---|---|
1 | PUMP/MOTOR ASSEMBLY | SR060510SV | 1 |
2 | SHROUD | — | 1 |
3 | SCREW, M4 X 10 | — | 8 |
4 | ELBOW | ● | 1 |
5 | EXHAUST TUBE | ● | 1 |
6 | WASHER | ● | 2 |
7 | CHECK VALVE ASSEMBLY | SR060511SV | 1 |
8 | HANDLE GRIP | — | 1 |
9 | HANDLE | — | 1 |
10 | FILTER | SR060512SV | 1 |
11 | CAPACITOR | ▲ | 1 |
12 | CAPACITOR COVER | ▲ | 1 |
13 | SCREW, M5 X 10 | ▲ | 2 |
14 | RUBBER BUSHING | — | 4 |
15 | NUT, M6 | — | 4 |
16 | TANK GAUGE, 1/8 NPT 1.5 IN. DIA. | — | 1 |
17 | CONNECT, NPT 1/4 X 48 | ■ | 1 |
18 | PRESSURE SWITCH | ■ | 1 |
19 | SAFETY VALVE | ■ | 1 |
20 | PLUG, 1/4 NPT | ■ | 1 |
21 | CONNECT, NPT 1/4 X 30 | ■ | 1 |
22 | REGULATOR | ■ | 1 |
23 | OUTLET GAUGE, 1/8 NPT 2 IN. DIA. | ■ | 1 |
24 | COUPLER | ■ | 1 |
25 | RELIEF NUT | ▼ | 1 |
26 | UNLOADER TUBE | ▼ | 1 |
27 | POWER CORD | — | 1 |
28 | CABLE CONNECT U | — | 2 |
29 | CABLE CONNECT O | — | 1 |
30 | BOLT | — | 2 |
31 | TANK | — | 1 |
32 | DRAIN VALVE | SR060513SV | 1 |
33 | NUT, M8 | ◆ | 2 |
34 | WASHER, M8 | ◆ | 4 |
35 | RUBBER FOOT | ◆ | 2 |
36 | BOLT, M8 X 25 | ◆ | 2 |
37 | NUT, M10 | ❖ | 2 |
38 | SPRING WASHER, M10 | ❖ | 2 |
39 | WHEEL, 6 IN. | ❖ | 2 |
40 | BOL T , M10 X 36.5 | ❖ | 2 |
REPAIR PARTS KITS
▲ | CAPACITOR KIT | SR060514SV |
---|---|---|
▼ | UNLOAD TUBE ASSEMBLY | SR080515SV |
◆ | RUBBER FOOT KIT | SR080512SV |
● | EXHAUST TUBE KIT | SR080513SV |
■ | PRESSURE SWITCH/REGULATOR KIT | SR060518SV |
❖ | TANK WHEEL KIT | SR080514SV |
— | NOT AVAILABLE |
REPAIR PARTS ILLUSTRATION FOR SR060510SV REPAIR PARTS LIST FOR SR060510SV
Ref. No. | Description | Part Number: | Qty. |
---|---|---|---|
1 | BOLT, M5 X 30 | ● | 12 |
2 | SPRING WASHER, M5 | ● ▲ | 18 |
3 | RELIEF VALVE | ◗ | 1 |
4 | CYLINDER HEAD | ● | 2 |
5 | SEAL OF CYLINDER HEAD | — | 2 |
6 | SCREW, M4 X 8 | ■ | 2 |
7 | VALVE LIFT GUARD | ■ | 2 |
8 | VALVE REED | ■ | 4 |
9 | VALVE PLATE | ■ | 2 |
10 | VALVE BACKER | ■ | 2 |
11 | SCREW, M4 X 6 | ■ | 2 |
12 | O-RING OF CYLINDER | — | 2 |
13 | CYLINDER | — | 2 |
14 | PISTON CAP SCREW | ▲ | 2 |
15 | PISTON CAP | ▲ | 2 |
16 | PISTON RING | ▲ | 2 |
17 | CON-ROD | ▲ | 2 |
18 | CON-ROD SCREW, M5 X 20 | ▲ | 2 |
19 | CROSSOVER TUBE | ▼ | 2 |
20 | O-RING FOR CROSSOVER TUBE | ▼ | 4 |
21 | STATOR | — | 1 |
22 | ROTOR | — | 1 |
23 | BEARING | — | 2 |
24 | FRONT END BELL | — | 1 |
25 | BEARING | ◆ | 2 |
26 | ECCENTRIC | ◆ | 2 |
27 | ECCENTRIC SCREW, M8 X 10 | ◆ | 2 |
28 | COOLING FAN (LEFT) | ❍ | 1 |
29 | EXTERNAL RETAINING RING | ❍ ❏ | 2 |
30 | TAMPING SCREW, ST4 X 18 | ❍ ❏ | 4 |
31 | COOLING FAN COVER | ❍ ❏ | 2 |
32 | COOLING FAN (RIGHT) | ❏ | 1 |
33 | MOTOR BOLT, M5 X 182 | — | 4 |
34 | SCREW, M4 X 6 | — | 1 |
35 | WASHER, M4 | — | 1 |
36 | GROUND SIGNAL | — | 1 |
37 | REAR END BELL | — | 1 |
REPAIR PARTS KITS
● | PUMP HEAD KIT | SR060519SV |
---|---|---|
■ | VALVE PLATE KIT | SR060520SV |
▲ | PISTON CYLINDER KIT | SR060521SV |
▼ | CROSSOVER TUBE FITTING KIT | SR060522SV |
◆ | ECCENTRIC/BEARING ASSEMBLY KIT | SR060523SV |
❍ | FRONT END FAN KIT | SR060524SV |
❏ | MOTOR FAN KIT | SR060525SV |
◗ | COLD START VALVE KIT | SR060526SV |
— | NOT AVAILABLE |
Reminder: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
LIMITED WARRANTY
-
DURATION: From the date of purchase by the original purchaser as follows: One Year.
-
WHO GIVES THIS WARRANTY (WARRANTOR): Campbell Hausfeld a Marmon/Berkshire Hathaway Company, 100 Production Drive, Harrison, Ohio, 45030, Visit www.campbellhausfeld.com
-
WHO RECEIVES THIS WARRANTY (PURCHASER): The original purchaser {other than for purposes of resale) of the Campbell Hausfeld compressor.
-
WHAT PRODUCTS ARE COVERED BY THIS WARRANTY: This DC080500 Campbell Hausfeld air compressor.
-
WHAT IS COVERED UNDER THIS WARRANTY: Parts and Labor to remedy substantial defects due to material and workmanship during the first year of ownership with the exceptions noted below. Parts only to remedy substantial defects due to material and workmanship during remaining term of coverage with exceptions noted below.
-
WHAT IS NOT COVERED UNDER THIS WARRANTY:
A. Implied warranties, including those of merchantability and FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED FROM THE DATE OF ORIGINAL PURCHASE AS STATED IN THE DURATION. If the compressor is used for commercial, industrial or rental purposes, the warranty will apply for ninety (90) days from the date of purchase. Two-stage compressors are not limited to a ninety (90) day warranty when used in commercial or industrial applications. Some States do not allow limitations on how long an implied warranty lasts, so the above limitations may not apply to you
B. ANY INCIDENTAL, INDIRECT, OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECT, FAILURE, OR MALFUNCTION OF THE CAMPBELL HAUSFELD PRODUCT. Some States do not allow the exclusion or limitations of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
C. Any failure that results from an accident, purchaser’s abuse, neglect or failure to operate products in accordance with instructions provided in the owner’s manual{s) supplied with compressor.
D. Pre-delivery service, e.g. assembly, oil or lubricants, and adjustment.
E. Items of service that is normally required to maintain the product, e.g. lubricants, filters and gaskets, etc.
F. Gasoline engines and components are expressly excluded from coverage under this limited warranty. The Purchaser must comply with the warranty given by the engine manufacturer which is supplied with the product
G. Additional items not covered under this warranty: -
Excluded items pertaining to All Compressors
a. Any component damaged in shipment or any failure caused by installing or operating unit under conditions not in accordance with installation and operation guidelines or damaged by contact with tools or surroundings.
b. Pump or valve failure caused by rain, excessive humidity, corrosive environments or other contaminants.
c. Cosmetic defects that do not interfere with compressor functionality.
d. Rusted tanks, including but not limited to rust due to improper drainage or corrosive environments.
e. The following components are considered normal wear items and are not covered after the first year of ownership. Electric motor, check valve, pressure switch, regulator, pressure gauges, hose, tubing, pipe, fittings and couplers, screws, nuts, hardware items, belts, pulleys, flywheel, air fitter and housing, gaskets, seals, oil leaks, air leaks, oil consumption or usage, piston rings.
f. Tank drain valves.
g. Damage due to incorrect voltage or improper wiring.
h. Other items not listed but considered general wear parts.
i. Pressure switches, air governors, load/unload devices, throttle control devices and safety valves modified from factory settings.
j. Damage from inadequate filter maintenance.
k. Induction motors operated with electricity produced by a generator. -
Excluded items specific to Lubricated Compressors:
a. Pump wear or valve damage caused by using oil not specified.
b. Pump wear or damage caused by any oil contamination.
c. Pump wear of damage caused by failure to follow proper oil maintenance guidelines, operation below proper oil level or operation without oil.
H. Labor, service call, or transportation charges after the first year of ownership. -
RESPONSIBILITIES OF WARRANTOR UNDER THIS WARRANTY: Repair or replace, at Warrantor’s option, compressor or component which is defective, has malfunctioned and/or failed to conform within the duration of the specific warranty period.
-
RESPONSIBILITIES OF PURCHASER UNDER THIS WARRANTY:
A. Provide dated proof of purchase and maintenance records.
B. Call Campbeil Hausfeld (800-543-6400) to obtain your warranty service options. Freight costs must be borne by the purchaser.
C. Use reasonable care in the operation and maintenance of the products as described in the owner’s manual(s).
D. Repairs requiring overtime, weekend rates, or anything beyond the standard manufacturer warranty repair labor reimbursement rate.
E. Time required for any security checks, safety training, or similar for service personnel to gain access to facility.
F Location of unit must have adequate clearance for service personnel to perform repairs and easily accessible. -
WHEN WARRANTOR WILL PERFORM REPAIR OR REPLACEMENT UNDER THIS WARRANTY: Repair or replacement will be scheduled and serviced according to the normal work flow at the servicing location, and depending on the availability of replacement parts.
This Limited Warranty applies in the U.S., Canada and Mexico only and gives you specific legal rights. You may also have other rights which vary from State to State or country to country.
Please r ead and save these instructions. Read car efully befor e attempting
to assemble, install, operate or maintain the pr oduct described.
Pr otect yoursel f and others by observing all safety information. Failur e to
comply with instructions could result in personal injury and/or pr operty
damage! Retain instructions for future refer ence.
REMINDER: Keep your dated pr oof of pur chase for warranty purposes! Attach it
to this manual or file it for safekeeping.
Model #: __
Serial #: ___
Pur chase Date: _
For parts, pr oduct & service information visit
www.campbellhausfeld.com
Campbell Hausfeld
100 Pr oduction Drive
Harrison, Ohio 45030
REGISTER YOUR PRODUCT ONLINE NOW!
www.campbellhausfeld.com
READ AND FOLLOW ALL INSTRUCTIONS
SA VE THESE INSTRUCTIONS
DO NOT DISCARD