IXIO-DT1 Motion and Presence Sensor for Automatic Sliding Doors User Guide
- June 13, 2024
- IXIO
Table of Contents
IXIO-DT1
MOTION AND PRESENCE SENSOR FOR
AUTOMATIC SLIDING DOORS
QUICK GUIDEhttps://www.qrfy.com/pxr1pxFaG0
DT1 Motion and Presence Sensor for Automatic Sliding Doors
READ BEFORE BEGINNING INSTALLATION & SETUP
| | |
---|---|---|---
The sensor should be mounted securely to avoid extreme vibrations.| Do not
cover the sensor.| Avoid moving objects and light sources in the detection
field.| Avoid highly reflective objects in the infrared field.
| | |
The door control unit and the header cover profile must be correctly
grounded.| Only trained and qualified personnel are recommended for
installation and setup of the sensor.| Following installation, always test for
proper operation (according to ANSI 156.10) before leaving the premises.| The
warranty is invalid if unauthorized repairs are made or attempted by
unauthorized personnel.
This device can be expected to comply with Part 15 of the FCC Rules, provided it is assembled in exact accordance with the instructions provided with this kit. Operation is subject to the following conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
MOUNTING & WIRING
Refer to Application Note 76.0035 if an IXIO Spacer is required for the given application.
Sensor connectivity (power and relays) must utilize only the supplied harness.
Sensor power must be supplied from a Class 2 supply source limited to 15 W.
Sensor is intended to be monitored for proper operation by the door operator
or system.
Harness shall be routed separated from any Mains or non-Class 2 voltage cable for correct operation or shall be rated for the Mains voltage, and suitable protection and routing means shall be used according to National and Local Codes to prevent damage to the harness and/or IXIO sensor.
RADAR OPENING IMPULSE FIELD
ANGLE
WIDTH
INFRARED SAFETY FIELD
ANGLE
WIDTH
SETUP
STEP OUT OF THE INFRARED FIELD!
SETUP 1 (QUICK)
reference picture
either hold the knob for 2 seconds, or use the remote control buttons as
specified
SETUP 2 (ASSISTED)
test of full door cycle + reference picture either hold the knob for 4
seconds, or use the remote control buttons as specified
TEST THE PROPER OPERATION OF THE INSTALLATION BEFORE LEAVING THE PREMISES!
LED SIGNALS
COLORS
| (green)
Motion detection
---|---
| (red)
Presence detection
BEHAVIORS
| LED flashes
---|---
| LED flashes quickly
| LED flashes x times
| LED flashes red-green
| LED is off
OVERVIEW OF SETTINGS
Download the BEA DECODER app for a quick overview of settings
Note 1| Always use a screwdriver when making further AIR adjustments to the
arrow position on the sensor.
---|---
Note 2| RADAR| AIR
NO = normally open
NC = normally closed
DeEner = de-energized relay (active) Energ = energized relay (passive)| NO =
normally open NC = normally closed
Note 3| The sensor LED will briefly flash RED during monitoring communication
with door control. This indicates that external monitoring is functional.
Monitoring functionality must be active on the sensor and door control, and
monitoring wires must be properly connected to the door control.
Note 4| MTF = uni-directional with motion-tracking feature uni + reentry: BEA
recommends only adjusting using the LCD
Note 5| REDIRECTION setting (F1 on remote control):
R1-MW, R2-IR (f1=0):
R1 = MW (i.e. motion detection)
R2 = IR (i.e. presence detection)| R1-MW or IR, R2-IR (F1=1):
R1 = MW or IR (i.e. motion or presence detection)
R2 = IR (i.e. presence detection)
Note 6| partial: outputs are not reset
TECHNICAL SPECIFICATIONS
Output|
---|---
Relay 1| Relay 2
Electromechanical relay (potential and polarity free)
Max. contact current: 1 A
Max. contact voltage: 30 VAC
Adjustable hold time: 0.5 – 9 s| Solid-state relay (potential and polarity
free)
Max. contact current: 100 mA
Max. contact voltage: 42 VDC / 30 VAC
Test/Monitoring input:| Sensitivity:
Low: < 1 V
High: > 10 V (max. 30 V)
Response time on test request: typical < 5 ms
Supply voltage:| 12 – 24 VAC ±10%
12 – 30 VDC ±10%
to be operated from SELV-compatible power supplies only
Mounting height:| 6’6” – 11’6”
local regulations may impact acceptable mounting height (pedestrian
applications only)
Specifications are subject to change without prior notice.
All values measured in specific conditions.
BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS
BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect
installations or incorrect adjustments of the sensor/device; therefore, BEA,
Inc. does not guarantee any use of the sensor/device outside of its intended
purpose.
BEA, Inc. strongly recommends that installation and service technicians be
AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/ gates, and
factory-trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk
assessment following each installation/service performed, ensuring that the
sensor/device system performance is compliant with local, national, and
international regulations, codes, and standards.
Once installation or service work is complete, a safety inspection of the
door/gate shall be performed per the door/gate manufacturer’s recommendations
and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry
practices. Safety inspections must be performed during each service call –
examples of these safety inspections can be found on an AAADM safety
information label (e.g.
ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and International Building
Code).
Verify that all appropriate industry signage, warning labels, and placards are
in place.
Tech Support & Customer Service:
1-800-523-2462
General Tech Questions: techservices-us@BEAsensors.com | Tech Docs:
www.BEAsensors.com
75.1219.01 IXIO-DT1 QG 20230913
Read User Manual Online (PDF format)