IXIO-DT1 Motion and Presence Sensor for Automatic Sliding Doors User Guide

June 13, 2024
IXIO

IXIO- logo IXIO-DT1
MOTION AND PRESENCE SENSOR FOR
AUTOMATIC SLIDING DOORS

QUICK GUIDEIXIO-DT1 Motion and Presence Sensor for Automatic Sliding
Doors - qr codehttps://www.qrfy.com/pxr1pxFaG0

DT1 Motion and Presence Sensor for Automatic Sliding Doors

READ BEFORE BEGINNING INSTALLATION & SETUP

| | |
---|---|---|---
The sensor should be mounted securely  to avoid extreme vibrations.| Do not cover the sensor.| Avoid moving objects and light sources in the detection field.| Avoid highly reflective objects in the infrared field.
| | |
The door control unit and the header  cover profile must be correctly grounded.| Only trained and qualified personnel are recommended  for installation and setup of the sensor.| Following installation, always test for proper operation (according to ANSI 156.10) before  leaving the premises.| The warranty is invalid if unauthorized repairs are  made or attempted by unauthorized personnel.

This device can be expected to comply with Part 15 of the FCC Rules, provided it is assembled in exact accordance with the instructions provided with this kit. Operation is subject to the following conditions: (1) this device may not cause harmful interference, and  (2) this device must accept any interference received, including interference that may cause undesired operation.

MOUNTING & WIRING

Refer to Application Note 76.0035 if an IXIO Spacer is required for the given application.

IXIO-DT1 Motion and Presence Sensor for Automatic Sliding Doors - MOUNTING &
WIRING 2

Sensor connectivity (power and relays) must utilize only the supplied harness.
Sensor power must be supplied from a Class 2 supply source limited to 15 W.
Sensor is intended to be monitored for proper operation by the door operator or system.

Harness shall be routed separated from any Mains or non-Class 2 voltage cable for correct operation or shall be rated for the Mains voltage, and suitable protection and routing means shall be used according to National and Local Codes to prevent damage to the  harness and/or IXIO sensor.

RADAR OPENING IMPULSE FIELD

ANGLE

IXIO-DT1 Motion and Presence Sensor for Automatic Sliding Doors -
ANGLE

WIDTH

IXIO-DT1 Motion and Presence Sensor for Automatic Sliding Doors -
WIDTH

INFRARED SAFETY FIELD

ANGLE

IXIO-DT1 Motion and Presence Sensor for Automatic Sliding Doors - ANGLE
2

WIDTH

IXIO-DT1 Motion and Presence Sensor for Automatic Sliding Doors - WIDTH
2

SETUP

STEP OUT OF THE INFRARED FIELD!

SETUP 1 (QUICK)
reference picture
either hold the knob for 2 seconds, or use the remote control buttons as specified

IXIO-DT1 Motion and Presence Sensor for Automatic Sliding Doors - icon
4

SETUP 2 (ASSISTED)
test of full door cycle + reference picture either hold the knob for 4 seconds, or use the remote control buttons as specified

IXIO-DT1 Motion and Presence Sensor for Automatic Sliding Doors - icon
5

IXIO-DT1 Motion and Presence Sensor for Automatic Sliding Doors - icon
6

TEST THE PROPER OPERATION OF THE INSTALLATION BEFORE LEAVING THE PREMISES!

LED SIGNALS

COLORS

| (green)
Motion detection
---|---
| (red)
Presence detection

BEHAVIORS

| LED flashes
---|---
| LED flashes quickly
| LED flashes x times
| LED flashes red-green
| LED is off

OVERVIEW OF SETTINGS

IXIO-DT1 Motion and Presence Sensor for Automatic Sliding Doors - OVERVIEW
OF SETTINGS

Download the BEA DECODER app for a quick overview of settings

IXIO-DT1 Motion and Presence Sensor for Automatic Sliding Doors - qr cod
2http://is.gd/WjkMxl

Note 1| Always use a screwdriver when making further AIR adjustments to the arrow position on the sensor.
---|---
Note 2| RADAR| AIR
NO = normally open
NC = normally closed
DeEner = de-energized relay (active) Energ = energized relay (passive)| NO = normally open NC = normally closed
Note 3| The sensor LED will briefly flash RED during monitoring communication with door control. This indicates that external monitoring is functional.
Monitoring functionality must be active on the sensor and door control, and monitoring wires must be properly connected to the door control.
Note 4| MTF = uni-directional with motion-tracking feature uni + reentry: BEA recommends only adjusting using the LCD
Note 5| REDIRECTION setting (F1 on remote control):
R1-MW, R2-IR (f1=0):
R1 = MW (i.e. motion detection)
R2 = IR (i.e. presence detection)| R1-MW or IR, R2-IR (F1=1):
R1 = MW or IR (i.e. motion or presence detection)
R2 = IR (i.e. presence detection)
Note 6| partial: outputs are not reset

TECHNICAL SPECIFICATIONS

Output|
---|---
Relay 1| Relay 2
Electromechanical relay (potential and polarity free)
Max. contact current: 1 A
Max. contact voltage: 30 VAC
Adjustable hold time:  0.5 – 9 s| Solid-state relay (potential and polarity free)
Max. contact current:  100 mA
Max. contact voltage: 42 VDC / 30 VAC
Test/Monitoring input:| Sensitivity:
Low:  < 1 V
High:  > 10 V (max. 30 V)
Response time on test request: typical < 5 ms
Supply voltage:| 12 – 24 VAC ±10%
12 – 30 VDC ±10%
to be operated from SELV-compatible power supplies only
Mounting height:| 6’6” – 11’6”
local regulations may impact acceptable mounting height (pedestrian applications only)

Specifications are subject to change without prior notice.
All values measured in specific conditions.

BEA, INC. INSTALLATION/SERVICE COMPLIANCE EXPECTATIONS

BEA, Inc., the sensor manufacturer, cannot be held responsible for incorrect installations or incorrect adjustments of the sensor/device; therefore, BEA, Inc. does not guarantee any use of the sensor/device outside of its intended purpose.
BEA, Inc. strongly recommends that installation and service technicians be AAADM-certifi ed for pedestrian doors, IDA-certifi ed for doors/ gates, and factory-trained for the type of door/gate system.
Installers and service personnel are responsible for executing a risk assessment following each installation/service performed, ensuring that the sensor/device system performance is compliant with local, national, and international regulations, codes, and  standards.
Once installation or service work is complete, a safety inspection of the door/gate shall be performed per the door/gate manufacturer’s recommendations and/or per AAADM/ANSI/DASMA guidelines (where applicable) for best industry practices. Safety  inspections must be performed during each service call – examples of these safety inspections can be found on an AAADM safety information label (e.g.
ANSI/DASMA 102, ANSI/DASMA 107, UL294, UL325, and International Building Code).
Verify that all appropriate industry signage, warning labels, and placards are in place.

IXIO-DT1 Motion and Presence Sensor for Automatic Sliding Doors - icon
7

Tech Support & Customer Service: 1-800-523-2462
General Tech Questions: techservices-us@BEAsensors.com | Tech Docs: www.BEAsensors.com

75.1219.01 IXIO-DT1 QG 20230913

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals