Safety Instructions

  1. Make sure your battery has enough voltage for the controller to recognize the battery type before first installation.
  2. The battery cable should be as short as possible to minimize power loss.
  3. This solar regulator is preset to suit lithium Ion batteties. (Please set the controller to the correct battery type when using.)
  4. The charge regulator is only suitable for regulating solar modules. Never connect another charging source to the charge regulator.
  5. The controller will get hot when it is working, please install the controller on a smooth, well ventilated surface.

Product Features

  1. Built-in industrial micro controller.
  2. LCD display with adjustable parameters.
  3. Fully 3-stage PWM charge management.
  4. Built-in short-circuit protection, open-circuit protection, reverse protection ,over-load protection.
  5. Dual mosfet reverse current protection, low heat production.

LCD Display/Key

iTECHWORLD 2420 20 AMP MPPT Solar Regulator Charge Controller - fig
1

menu: switch between different display, or to enter/exit setting by long press.
up: press to increase value.
down: press to decrease value.

System Connection

  1. Connect your battery to the charge regulator positive+and negative-
  2. Connect your solar panel to the solar input positive+an negative-
  3. Connect your load to the charge regulator positive+and negative-
    The reverse order applies when deinstalling!
    An improper sequence order can damage the controller!

iTECHWORLD 2420 20 AMP MPPT Solar Regulator Charge Controller - fig
2

Display/Setting

iTECHWORLD 2420 20 AMP MPPT Solar Regulator Charge Controller - fig
3

Attn:1. Press the [down] button to on/off load manully at main display.
2.The work mode is working as below: [24H]Load output 24 hours
[1-23H]Load on after sunset and closed after, setting hours

TroubleShooting

Situation Probable Cause Solution
Charge icon not on when sunny Solar panel opened or reversed Reconnect
Load icon off Mode setting wrong Set again
Battery low Recharge
Load icon slow flashing Over load Reduce load watt
Load icon fast flashing Short circuit protection Auto reconnect
Power off Battery too low/Reverse Check battery/Connection

Technical Parameter

Model 2420 2440
System Voltage 12V/24V AUTO
Charge Current 10A 20A
Discharge Current WA 20A
Max Solar Input < 50V
Default Battery Type 1 B3 (3.2V*4)(12V)(Lithium Lifepo4)
Float Charge 14.4V (defaul, adjustable)
LVD 10.4V (defaul, adjustable)
LVR 11.6V (defaul, adjustable)
Battery Type LifePo4 Gel
Code 1b3 2b3
Battery Charge 12V 24V
Float Charge 14.4V 28.8V
. Discharge Cut-off voltage 10.4V 20.8V
Discharge Recovery voltage 11.6V 23.2V
Constant Voltage 14.4V 28.8V