TURCK PSU67-1P-1S-2L-24150-IOL-F Smart Power Supply Module User Guide

August 13, 2024
TURCK

TURCK PSU67-1P-1S-2L-24150-IOL-F Smart Power Supply Module

Product Specifications

  • Model: PSU67-1P-1S-2L-24150-IOL-F
  • Output Voltage: 24 VDC (PELV), Nominal
  • Output Power:
    • Continuous at Ambient Temperature: 360 W
    • Short-term (up to 5s): 300 W
  • Input Voltage: 100-240 V AC
  • Output Current: Up to 12 A per output
  • Protection Class: Class I
  • Operating Temperature: -25°C to 0°C

Product Usage Instructions

General Safety Instructions

  • The device should only be handled by trained personnel.
  • Ensure the device is de-energized before mounting, dismounting, installing, or maintaining it.
  • Follow safety guidelines for working with electrical equipment.

Special Mounting Instructions

  • Ensure all sharp edges are covered.
  • Leave space of 10mm in front, and 10mm on the left and right side for proper ventilation.

Connectors

  • Input Voltage (XD1): M12 socket, S-coded, 3-pin
  • IO-Link (X0): M12 socket, A-coded, 5-pin
  • Output Voltage (XD2, XD3): M12 plug, L-coded, 5-pin

Operation
CAUTION: Follow these steps carefully while operating the device:

  1. In Monitoring Mode (Normal Operation), press [Voltage Set] button for 3 seconds to enter Configuration Mode.
  2. In Configuration Mode, all LEDs will briefly blink.
  3. Press [] or [] buttons to manually turn channels on or off.

Disposal
Follow proper disposal guidelines for electronic devices. Do not dispose of in regular waste.

Frequently Asked Questions (FAQ)

  • What is the maximum output power of the PSU67-1P-1S-2L-24150-IOL-F?
    The device has a continuous output power of 360W at ambient temperature and a short-term output power of up to 300W for a maximum of 5 seconds.

  • What is the input voltage range supported by the PSU67-1P-1S-2L-24150-IOL-F?
    The input voltage range is 100-240V AC with a tolerance of -15% to +10%.

Additional documents

The following additional documents are available online at www.turck.com

  • Data sheet
  • Declaration of conformity

For your safety

Intended use

  • The power supply PSU67-1P-1S-2L-24150-IOL-F is a stand-alone switching power supply for singel-phase indoor networks with IO-Link interface.
  • The device may only be used as described in these instructions. Any other use is not in accordance with the intended use. Turck accepts no liability for any resulting damage.

General safety instructions

  • The device must only be mounted, installed, operated and maintained by trained and qualified personnel.
  • Only mount, dismount, install and maintain the device when it is de-energized. Secure against reconnection of the voltage.
  • The device is a Class of Protection I equipment according to IEC 61140.
  • The device is designed for pollution degree 3 areas in controlled environments.
  • Only use the device in applications up to overvoltage category III according to IEC 60664-1. From an altitude of 2000 m, use only in applications up to overvoltage category II.
  • Only use the device with additional protective devices in the area of personal and machine protection.
  • Operate the device exclusively within the technical specifications in order not to impair the protective function of the device.
  • Do not connect the negative potential of any output externally to PE.
  • Only use the device with a proper PE (Protective Earth) connection.

Product description

Device overview
S. fig. 2: dimensions, s. fig. 3: Block diagram

Functions and operating modes

  • The power supply provides a stabilized and galvanically separated PELV/ES1 output voltage at the four outputs OUT1 …OUT4. The negative potential of the outputs is permanently connected to PE in the device. The outputs are electronically protected against open-circuit, overload and short-circuit and can supply any type of loads, including unlimited inductive and capacitive loads.
  • The device can be connected to an IO-Link master via an IO-Link interface V1.1.
  • The device is equipped with an over-temperature protection. In case of a over temperature, the device shuts down and starts automatically again after cooling off. The outputs return to the state they had before being switched off.
  • In case of an internal defect, a redundant circuit limits the maximum output voltage to 32.5 V. The outputs are shut down and restart automatically if the defect is eliminated.

Installation

General installation instructions

  • The unit is suitable for use at altitudes up to 5000 m (16400 ft). Above 2000 m (6560 ft), the output current and overvoltage category must be reduced.
  • The device is suitable for use at TN, TT and IT networks.
  • The voltage between the input terminals and the PE potential must not exceed 264 VAC.
  • The device uses convection cooling. An external fan is not necessary.

Special mounting instructions
CAUTION
Sharp edges on the back of the device
Risk of injury
Mount the devices on a sufficiently large, even surface so that all sharp edges are covered.

  • Mount the device vertically with the connection level facing downwards on a flat surface using two screws each (M4 or UNC 8-32) at the upper and lower mounting holes.
  • Other mounting orientations: reduce the output current.
  • Do not obstruct airflow. Do not cover ventilation fins.
  • Observe the minimum installation clearances: 30 mm on top and bottom, 10 mm on the front and 10 mm left and right side.

Connecting

Connect the device according to ”Wiring diagrams”.

Mating connectors

  • Input voltage (XD1): M12 female connector, S-coded, 3-pin
  • IO-Link (X0): M12 female connector, A-coded, 5-pin
  • Output voltage (XD2, XD3): M12 male connector, L-coded, 5-pin

Appropriate accessories can be found at www.turck.com. The accessories are not part of the scope of delivery.

  • Do not apply return voltages from the load to the output higher than 35 V.
  • Do not connect outputs or devices in parallel.

The device is designed, tested and approved for branch circuits up to 20 A (UL) and 32 A (IEC) without additional protection device.

  • If an external fuse is used, use B or C characteristic circuit breakers with at least 6 A to avoid a nuisance tripping of the circuit breaker.
  • DC supply voltages above 150 VDC: Use an external circuit breaker (6 A with B or C characteristic).
    If capacitors with a capacitance >20 mF are connected to one output, this output might switch off after turning the unit or the output on or connecting the load.

Operating

CAUTION
Hot surfaces
Burn risk
Do not touch the housing during operation or shortly after power-off.
The green status LED indicates that the output voltage is above 90% of the set output voltage and that no output has been switched off due to overcurrent or overtemperature.

IO-Link interface
The device can be parameterized via IO-Link using the associated IODD. In addition, device-internal measurement data and diagnostics are made available via IO-Link. The IODD programming software can be downloaded for free from www.turck.com.

LED bar and push-buttons
The green Status LED reports an output above 90% of the set output voltage.

  • Monitoring mode (normal operation):
    Actual output power = percentage of 300 W (100 % = 300 W) For values above 100 %, the LEDs flash orange. By pressing the up and down keys, the output current of the respective output is displayed as a percentage of the set tripping current. The orange LEDs OUT1…OUT4 indicate the selected output.

  • Configuration mode

    • Button [Voltage Set]

    • Hold for 3s

    • Configuration mode, all LEDs flash shortly

    • Start mode: “Set output voltage”: The output voltage is set for all outputs.

    • All orange LEDs are off.

    • Hold for 3 s, press 1×
      Mode ”Set tripping current”: The tripping current (s. fig. 4) is set separately for each output. The orange LEDs OUT1…OUT4 indicate the selected output.

    • Hold for 3 s, press n ×
      Select other output, n = no. of the output (only for ”Set tripping current”)

    • Buttons
      Set value The set value for output voltage or tripping current is indicated via the LED bar. The setting becomes effective immediately

Deactivating outputs

Press the button at the output channel (OUT1…OUT4) for at least 1 s to activate or deactivate the output manually.

Maintenance

Clean the devices at regular intervals with a damp cloth.

Repair
The device must not be repaired by the user. Take defective devices out of operation. Do not open the device. Observe our return acceptance conditions when returning the device to Turck.

Disposal

The devices must be disposed of correctly and must not be included in normal household garbage

Technical data

  • Device

    • Type designation PSU67-1P-1S-2L-24150-IOL-F
    • Order number 100028305
  • Outputs

    • Output voltage 24 VDC (PELV), nominal value
    • Adjustment range 24…28 VDC
    • Output power, continuous at ambient temperature:
    • at 45 °C 360 W
    • at 55 °C 300 W
    • at 70 °C 150 W
    • Output power, short-term, up to 5 s, at ambient temperature:
    • up to 55 °C, input voltage ≥100 VAC 600 W
    • at 70 °C 300 W
    • Linear derating between +45 °C and +70 °C (s. fig. 5)
    • Output currents Up to 12 A, settable per output
  • Input

    • Input voltage AC 100…240 V -15/+10 %
    • Mains frequency 50 Hz/60 Hz ±6 %
    • Input current AC 4/1.7 A at 100/230 VAC
    • Power factor 0.99/0.97 at 100/230 VAC
    • Input inrush current (at 25 °C) 2.6/6 A peak at 100/230 VAC
    • Input voltage DC 110…300 V ±20 %
    • Input current DC 3.6/1.3 A at 110/300 VDC
  • Efficiency

    • Efficiency 93.4/95 % at 100/230 VAC
    • Losses 20.8/23.0 W at 100/230 VAC
    • Hold-up time 33/33 ms at 100/230 VAC
  • Ambient conditions

    • Temperature range -25…+70 °C
    • Max. operating temperature +70 °C, measured 2 cm below the device
    • Relative humidity 5…95 %
  • Housing

    • Dimensions (l × w × h) 183 × 182 × 59 mm, without connectors
    • Weight 1200 g/2.7 lb
    • Degree of protection (according to IEC 60529)
    • IP65/IP67, only with correct mounting of all mating connectors
    • Protection against electrical, mechanical and fire hazards

Wiring diagrams

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals