TURCK TN-M18-H1147 HF Read/Write Device User Guide

June 5, 2024
TURCK

**TURCK TN-M18-H1147 HF Read/Write Device User Guide

**

Additional documents

Besides this document, the following material can be found on the Internet at www.turck.com:

  • Data sheet
  • RFID configuration manual
  • Commissioning manuals
  • Approvals

Additional information see

For your safety

Intended use

These devices are designed solely for use in industrial areas. BL ident read/write heads work on a frequency of 13.56 MHz and are used as a means of contactless data exchange with BL ident tags within BL ident HF RFID systems. They can only be connected to and operated with BL ident interfaces. The read/write heads T…-EM… offer protection class IP69K and are suitable for use in washdown applications, for example in the food industry. The read/write heads …/C53 can be used with the RFID interfaces TBEN-… to form a line topology. The devices must be used only as described in these instructions. Any other use is considered improper use and Turck accepts no liability for any resulting damage.

General safety instructions

  • The device must be fitted, installed, operated, parameterized and maintained only by trained and qualified personnel.
  • The devices meet the EMC requirements for industrial areas only and are not suitable for use in residential areas.

Product description

Device overview

Product overview

Functions and operating modes

The devices can be used to read and write passive HF tags in single-tag or multi-tag operation. To do this, the devices form a transmission zone. The size and expansion of this zone may vary on account of several conditions, for example the tags used and the application conditions. The possible tags and read-write distances are listed in the data sheets.

Installing

TB… devices can be mounted flush with the mounting surface. For TN… devices, which cannot be flush mounted, the front cap must protrude from the mounting surface. The maximum tightening torque for the housing nuts is 10 Nm (M12 model), 25 Nm (M18 model) or 75 Nm (M30 model).

  • Mount the device using the corresponding mounting accessories.
  • Maintain a minimum distance between the read/write heads.
    Model| Minimum distance
    ---|---
    M12| 36 mm
    M18| 54 mm
    M30| 90 mm
  • Avoid placing the read/write head in close proximity to metal. Metal rails or similar objects must not interrupt the transmission zone.
  • Protect the device against thermal radiation, sudden temperature fluctuations, high levels of dirt, electrostatic charging and mechanical damage.
Connection

Connect the device to the BL ident interface in accordance with the “Wiring Diagrams.”

Wiring Diagrams

Wiring Diagrams
Wiring Diagrams
Wiring Diagrams`

Commissioning

The device automatically becomes operational once the cables are connected and the power supply is switched on.

Operation

LEDs
LED indicator functions Meaning
Illuminated Device is operational
Flashing (1 Hz) HF field (read/write head antenna) switched off
Flashing (2 Hz) Tags within sensing range
Setting and parameterization

The devices are parameterized using the RFID interface. For more information, see the BL ident commissioning manuals.

Repair

The device must not be repaired by the user. The device must be decommissioned if it is faulty. When returning the device to Turck, please see our conditions for return.

Disposal

The devices must be disposed of correctly and must not be included in general household garbage.

EU Declaration of Conformity

Hereby, Hans Turck GmbH & Co. KG declares that the radio equipment type T…-(E)M…-H1147… is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.turck.com

Technical Data

Type| Ident-No.| Working frequency| Operating voltage| Active area material| Mounting conditions| Housing material| Dimensions| Protection class| Ambient temperature| Product remarks
---|---|---|---|---|---|---|---|---|---|---
TB-M12-H1147| 100003024| 13.56 MHz| 10…30 VDC| Plastic, PA12-GF30| Flush| Metal, CuZn, chrome-plated| 62 mm| IP67| -25…+70 °C| –
TB-M12-H1147/C53| 100003025| 13.56 MHz| 10…30 VDC| Plastic, PA12-GF30| Flush| Metal, CuZn, chrome-plated| 62 mm| IP67| -25…+70 °C| Suitable for bus mode to TBEN…
TN-M12-H1147| 100003026| 13.56 MHz| 10…30 VDC| Plastic, PA12-GF30| Non-flush| Metal, CuZn, chrome-plated| 62 mm| IP67| -25…+70 °C| –
TN-M12-H1147/C53| 100003027| 13.56 MHz| 10…30 VDC| Plastic, PA12-GF30| Non- flush| Metal, CuZn, chrome-plated| 62 mm| IP67| -25…+70 °C| Suitable for bus mode to TBEN…
TB-M18-H1147| 7030001| 13.56 MHz| 10…30 VDC| Plastic, PA12-GF30| Flush| Metal, CuZn,

chrome-plated

| 72 mm| IP67| -25…+70 °C| –
TB-EM18WD-H1147| 7030224| 13.56 MHz| 10…30 VDC| Plastic, LCP| Flush| Stainless steel (1.4404)| 72 mm| IP68/IP69K| -25…+70 °C| Wash-down
TB-M18-H1147/C53| 7030729| 13.56 MHz| 10…30 VDC| Plastic, PA12-GF30| Flush| Metal, CuZn,

chrome-plated

| 72 mm| IP67| -25…+70 °C| Suitable for bus mode to TBEN…
TN-M18-H1147| 7030002| 13.56 MHz| 10…30 VDC| Plastic, PA12-GF30| Non-flush| Metal, CuZn,

chrome-plated

| 72 mm| IP67| -25…+70 °C| –
TN-EM18WD-H1147| 7030223| 13.56 MHz| 10…30 VDC| Plastic, LCP| Non-flush| Stainless steel (1.4404)| 72 mm| IP68/IP69K| -25…+70 °C| Wash-down
TN-M18-H1147/C53| 7030728| 13.56 MHz| 10…30 VDC| Plastic, PA12-GF30| Non- flush| Metal, CuZn,

chrome-plated

| 72 mm| IP67| -25…+70 °C| Suitable for bus mode to TBEN…
TB-M30-H1147| 7030003| 13.56 MHz| 10…30 VDC| Plastic, PA12-GF30| Flush| Metal, CuZn, chrome-plated| 62 mm| IP67| -25…+70 °C| –
TB-EM30WD-H1147| 7030221| 13.56 MHz| 10…30 VDC| Plastic, LCP| Flush| Stainless steel (1.4404)| 62 mm| IP68/IP69K| -25…+70 °C| Wash-down
TB-M30-H1147/C53| 7030731| 13.56 MHz| 10…30 VDC| Plastic, PA12-GF30| Flush| Metal, CuZn, chrome-plated| 62 mm| IP67| -25…+70 °C| Suitable for bus mode to TBEN…
TN-M30-H1147| 7030004| 13.56 MHz| 10…30 VDC| Plastic, PA12-GF30| Non-flush| Metal, CuZn, chrome-plated| 62 mm| IP67| -25…+70 °C| –
TN-EM30WD-H1147| 7030222| 13.56 MHz| 10…30 VDC| Plastic, LCP| Non-flush| Stainless steel (1.4404)| 62 mm| IP68/IP69K| -25…+70 °C| Wash-down
TN-M30-H1147/C53| 7030730| 13.56 MHz| 10…30 VDC| Plastic, PA12-GF30| Non- flush| Metal, CuZn,

chrome-plated

| 62 mm| IP67| -25…+70 °C| Suitable for bus mode

to TBEN…

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

TURCK User Manuals

Related Manuals