QUANTIFICATION RANGE

Corn quantification range: (0.5-10) ppm

SAMPLE PREPARATION

Collect and grind a representative sample.
Granulometria ideale 0,8 mm (20 mesh)

MATERIAL NECESSARY FOR THE ANALYSIS

√ included in the kit

√ included in the kit

√ included in the kit

  • Test (T): 48
  • Reaction wells (W)
  • QR Code MORE
  • GENius Extraction Solution: Cat# MCE021 (5L)
  • Reagent 1: Cat# ACC015 (200 mL)
  • Acqueous Extraction Buffer Cat# ACC1010
  • Incubator: Cat# MZINC-C
  • Portable player: Cat# MZREAD-F
  • Micropipette and tips: Cat# ACC3014|ACC3514
  • Graduated Cylinder: Cat# ACC1506
  • Sample Container: Cat# ACC3525
  • Centrifuge: Cat# ACC1064
  • Microtubi 2 ml: Cat# ACC1564
  • Litmus test: Cat# 08.4015.83
  • pH corrector: Cat# ACC005

SAMPLE EXTRACTION

  •  Weigh 5 g of sample
  •  Add 50 ml of GENius + 2 ml of Reagent 1
  •  Shake for 1 minute

2. Filter the 2nd sample 3

  •  Dilute the sample
  • Transfer 1500 ÿl of Aqueous Extraction Buffer in un microtubo da 2 ml
  •  Add 50 ÿl of filtered sample
  •  Shake briefly

NB: the pH of the mixture must be > 6.5

  • Transfer 200 ÿl of filtered sample to a reaction well
  • Resuspend the lyophilisate
  • Incubate for 3 minutes

5. Insert the strip and wait for 5 minutes of reaction time

INTERPRETATION OF RESULTS

Before reading the result, scan the QR code attached to the kit (white sheet).

If it is not present, contact: technical.support@generon.it Remove the absorbent pad with scissors.
Read the strip with the MZREAD-F portable reader.

NB: samples can be tested more representative while maintaining the proportions of point 1

The tools and accessories needed to perform the test are provided.

Toxin-Fast-Fumonisin

Product Specifications:

  • Product Name: Toxin Fast Fumonisin
  • Model: MZLFQTFM
  • Quantification Range for Corn: (0.5-10) ppm

Product Usage Instructions:

Sample Preparation:

1. Collect and grind a representative sample. Ideal particle size is 0.8 mm (20 mesh).

Sample Extraction:

2. Filter the sample.

3. Ensure the pH of the mixture is > 6.5.

Materials Required for Analysis:
  • Test Tubes: 48 included in the kit
  • Reaction Wells (W): included in the kit
  • QR Code for Corn: included in the kit
  • Extraction Solution GENius: Cat# MCE021 (5L)
  • Reagent 1: Cat# ACC015 (200 mL)
  • Aqueous Extraction Buffer Cat# ACC1010
  • Incubator: Cat# MZINC-C
  • Portable Reader: Cat# MZREAD-F
  • Micropipette and Tips: Cat# ACC3014|ACC3514
  • Graduated Cylinder: Cat# ACC1506
  • Sample Container: Cat# ACC3525
  • Centrifuge: Cat# ACC1064
  • 2 ml Microtubes: Cat# ACC1564
  • pH Indicator Paper: Cat# 08.4015.83
  • pH Corrector: Cat# ACC005
Interpreting Results:

4. Insert the strip and wait for a reaction time of 5 minutes.

5. Scan the QR code attached to the kit (white sheet) before reading the result.

If QR code is missing, contact technical.support@generon.it.

6. Remove the absorbent pad with scissors. Read the strip with the portable reader MZREAD-F.

Additional Information:

– The kit provides all necessary tools and accessories for conducting the test.


Frequently Asked Questions (FAQ):

Q: What are the different toxins that can be analyzed with this kit?

A: The kit can also analyze DON, Zearalenone, T2, and Aflatoxin in addition to Fumonisin.

Q: What is the dilution range for Aflatoxin analysis?

A: Aflatoxin analysis can be done in the dilution range of 6-30 ppb.