Sangamo CHSTAT3CHK 3Ch Programmable Thermostat with RF and WiFi Instructions
- August 12, 2024
- SANGAMO
Table of Contents
- Sangamo CHSTAT3CHK 3Ch Programmable Thermostat with RF and WiFi
- Product Usage Instructions
- Frequently Asked Questions
- Functions
- Receiver overview & thermostat pairing
- Wi-Fi configuration Preparation
- Thermostat overview
- Installation
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Sangamo CHSTAT3CHK 3Ch Programmable Thermostat with RF and WiFi
Product Specifications
- Brand: Sangamo
- Model: CHSTAT3CHK
- Description: Sangamo 3Ch Programmable Thermostat with RF and WiFi White
Product Usage Instructions
Receiver Overview & Thermostat Pairing
- Follow the LED indicators and buttons for each thermostat.
- For Thermostat 1 and Thermostat 2, follow the specific pairing instructions provided.
- If needed, manually pair thermostats to the receiver using the code pairing mode.
Wi-Fi Configuration
- Ensure your smartphone is connected to the desired Wi-Fi network.
- Download the ClickSmart+ App on your device.
- Sign in or register on the app.
Installation Instructions
- In the app, select the device and follow the on-screen instructions for pairing the receiver to the Wi-Fi network.
Thermostat Overview
- Turn on the thermostat and set the clock by pressing and holding the M button for 3 seconds.
- Adjust the minute, hour, and weekday settings as needed.
Frequently Asked Questions
Q: How do I reset the thermostat to factory settings?
A: To reset the thermostat, press and hold the reset button for 10 seconds until the display shows “RST”.
Q: Can I control multiple zones with this thermostat?
A: Yes, this thermostat supports multiple zones for heating and hot water control. Refer to the manual for setup instructions.
Functions
- Access and control 2 heating zones and 1 hot water zone via WiFi
- Large display for easy viewing
- Easy to install thermostat(s) and receiver
- Five touch-sensitive buttons for easy usage
- 6 on & off periods per day
- The display shows the set temperature, as well as the measured temperature and time
- Temperature(s) displayed in Celsius
- The thermostat(s) are supplied with a wall-fixing mount, a free-standing base, and a compact receiver (surface mount only)
Receiver overview & thermostat pairing
- LED: Receiver on/off indicator.
- LED: WiFi status / WiFi pairing button.
- Button: Short press to turn the receiver on/off, long press for WiFi pairing.
- LED Button: Heating status of Thermostat 1.
- Press to enter code pairing mode for Thermostat 1, the LED will flash quickly
- Turn off Thermostat 1, and long press the M button until the code shows on the screen, and then press the button.
- Wait until the LED has stopped flickering, once it has the code pairing has been successful, and shows on the screen
- LED Button: Override status of Thermostat 1. Press and hold to enable override, and press again to disable override.
- LED: Button Heating status of Thermostat 2.
- Press to enter code pairing mode for Thermostat 2, the LED will flash quickly
- Turn off Thermostat 2, and long press the M button until the code shows on the screen, and then press the button.
- Wait until the LED has stopped flickering, once it has the code pairing has been successful
- LEDButton: Override status of Thermostat 2 Press and hold to enable override, and press again to disable override.
Note: Kits come supplied pre-paired, if one or more thermostats need pairing to the gateway, follow the above steps.
Wi-Fi configuration Preparation
- Ensure that the smartphone is connected to the same Wi-Fi network to which you would like to attach the device.
- Ensure that you have a mobile device running iOS 8 or higher, or Android 4.1x or higher, and a 2.4GHz Wi-Fi connection.
- Download the ClickSmart+ App on your mobile device from the App Store or Google Play Store.
- Sign in or Register following the instructions on the ClickSmart+ App.
Installation Instructions
- On the ClickSmart+ app’s home page, click on the “+” symbol in the top right corner of the home screen.
- Then click on “ESP” on the left-hand side.
- And finally, click on “Smart WiFi 3Ch Programmable Thermostat Kit”.
- The app will then display on-screen instructions for pairing the CHSTAT3CHK receiver (CHSTAT3CHK-R) with the Wi-Fi network.
Thermostat overview
Thermostat 1 (single heating zone)
Clock & weekday setting
- Turn the thermostat on, then press and hold the “M” button for 3 seconds, set the clock (Minute-Hour-Weekday) by pressing or , each press of the “M” button will go to the next item setting.
7-day program schedule
- Press and hold “P” for 3 seconds to enter the program setting.
- Set the schedule (minute-hour-Temperature-period-day) by pressing or ~~~~, each press of the “P” button will go to the next item setting.
Default setting:
Period | 1 | 2 | 3 | 4 |
---|---|---|---|---|
Time | Temp | Time | Temp | Time |
Temp
1-5 (Mon – Fri)| 7:00| 22°C| 8:30| 19°C| 17:00| 22°C| 22:00|
19°C
6 (Saturday)| 8:00| 22°C| 8:30| 19°C| 17:00| 22°C| 22:00| 19°C
7 (Sunday)| 8:00| 22°C| 8:30| 19°C| 17:00| 22°C| 22:00| 19°C
Mode selection
Press “M” to select PRG (program) mode, MAN (manual) mode, or Eco mode.
Open window detect function (OWD function)
- Whilst the “open window detect” function is enabled in the parameter settings, the system will automatically stop heating when it detects a sudden drop in room temperature (2°C within 15 minutes as default).
- This is normally caused when a window and/or door is opened without turning off the heating.
- The device will return to the previous mode of operation after 30 minutes and then will disappear. Press any button to exit the OWD function during the heating-off period.
Child lock
- Under child lock-on (refer to section 3.1.6 of the Thermostat 1’s parameter settings), the buttons will lock once the backlight has turned off.
- Press & together for 5 seconds to unlock the thermostat temporarily for adjustments
Parameter settings
- When in off mode, press and hold “M” & for 6 seconds to enter the parameter setting Menu.
- Adjust the value by pressing or each press of “M” will go to the next item.
Menu | Description | Range | Default Value |
---|---|---|---|
01 | Temperature calibration for internal sensor | -8°C to 8°C | 0°C |
02 | Set point maximum | 5°C to 35°C | 35°C |
03 | Set point minimum | 5°C to 35°C | 5°C |
05 | Frost protection temp. | 5°C to 15°C | 5°C |
09 | Dead zone | 0°C to 3°C | 0°C |
11 | Child lock | 1:Lock 0:Unlock | 0 |
12 | Open Window Detect (OWD) function | 1:Enable 0:Disable | 0 |
13 | OWD detect time | 2 to 30 minutes | 15 minutes |
14 | OWD temperature drop | 2°C to 4°C | 2°C |
15 | OWD delay time select (return to previous working status) | 10 to 60 | |
minutes | 30 minutes | ||
17 | Factory reset | 0: No |
1: Yes, and then press the on/off button for 5 seconds, and wait until the thermostat restarts
| 0
| Software version| |
31| Master ID code| Read-only|
Thermostat 2 (1 heating zone & 1 hot water zone)
Clock & program schedule for the heating zone
- Turn the thermostat on, then press and hold the “M” button for 3 seconds.
- Set the clock (Minute-Hour-Weekday) by pressing or , each press of the “M” button will go to the next item setting.
- After setting the clock, press “M” for the program schedule setting.
- Set the schedule (Weekday-Period-Start time-Temp) by pressing or, each press of the “M” button will go to the next item setting.
Period | 1 | 2 | 3 | 4 | 5 | 6 |
---|---|---|---|---|---|---|
Time | Temp | Time | Temp | Time | Temp | Time |
Temp | Time | Temp | Time | Temp | ||
1-5 Monday to Fri | 7:00 | 22°C | 8:30 | 19°C | 12:00 | 22°C |
18:00 | 22°C | 22:00 | 19°C | |||
6 Saturday | 8:00 | 22°C | 8:30 | 19°C | 12:00 | 22°C |
22°C | 22:00 | 19°C | ||||
7 Sunday | 8:00 | 22°C | 8:30 | 19°C | 12:00 | 22°C |
22°C | 22:00 | 19°C |
Program schedule for water zone
Turn the thermostat on, then press and hold the button for 3 seconds to set the hot water program schedule. Set the schedule (weekday minute-hour-on/off) by pressing , each press of button will go to the next item setting.
Period | 1 | 2 | 3 | 4 | 5 | 6 |
---|---|---|---|---|---|---|
Time | Mode | Time | Mode | Time | Mode | Time |
Mode | Time | Mode | Time | Mode | ||
1-5 Monday to Fri | 7:00 | On | 8:30 | Off | 12:00 | On |
18:00 | On | 22:00 | Off | |||
6 Saturday | 8:00 | On | 8:30 | Off | 12:00 | On |
22:00 | Off | |||||
7 Sunday | 8:00 | On | 8:30 | Off | 12:00 | On |
22:00 | Off |
Mode selection for heating zone
Press “M” to select PRG (program) mode, MAN (manual) mode, or Eco mode.
Mode select for hot water zone
Open window detect function (OWD function)
- Whilst the “open window detect” function is enabled in the parameter settings, the system will automatically stop heating when it detects a sudden drop in room temperature (2°C within 15 minutes as default).
- This is normally caused when a window and/or door is opened without turning off the heating.
- The device will return to the previous mode of operation after 30 minutes and then will disappear. Press any button to exit the OWD function during the heating-off period.
Child Lock
- Under child lock-on (refer to section 3.1.6 of the Thermostat 1’s parameter settings), the buttons will lock once the backlight has turned off.
- Press & together for 5 seconds to unlock the thermostat temporarily for adjustments
Parameter settings
- When in off mode, press and hold “M” & for 6 seconds to enter the parameter setting Menu. Adjust the value by pressing or each press of “M” will go to the next item.
Menu | Description | Range | Default Value |
---|---|---|---|
01 | Temperature calibration for internal sensor | -8°C to 8°C | 0°C |
02 | Set point maximum | 5°C to 35°C | 35°C |
03 | Set point minimum | 5°C to 35°C | 5°C |
05 | Frost protection temp. | 5°C to 15°C | 5°C |
09 | Dead zone | 0°C to 3°C | 0°C |
11 | Child lock | 1:Lock 0:Unlock | 0 |
12 | Open Window Detect (OWD) function | 1:Enable 0:Disable | 0 |
13 | OWD detect time | 2 to 30 minutes | 15 minutes |
14 | OWD temperature drop | 2°C to 4°C | 2°C |
15 | OWD delay time select (return to previous working status) | 10 to 60 | |
minutes | 30 minutes | ||
17 | Factory reset | 0: No 1: Yes, and then press the on/off button for 5 | |
seconds, and wait until the thermostat restarts | 0 | ||
Software version | |||
31 | Master ID code | Read-only |
Installation
Thermostats Wall mounted
- Carefully seperate the front half of the thermostat from the back plate by placing a small flat-head terminal screwdriver into the slots on the bottom face of the thermostat.
- Mark 2 hole positions on the wall using the back plate as a positioning template. Drill at the marked positions and insert a raw plug into each hole. Screw the thermostat’s back plate securely on the wall.
- Remove the battery cover, and insert the batteries or plug in a USB type-C cable.
- Clip the front of the thermostat back onto the thermostat back plate.
Freestanding Installation
- Carefully seperate the front half of the thermostat from the back plate by placing a small flat-head terminal screwdriver into the slots on the bottom face of the thermostat.
- Remove the battery cover, and insert the batteries or plug in a USB type-C cable.
- Clip the front of the thermostat onto the provided holder.
Receiver Wall mounted
- Using a screwdriver, slightly loosen the screw located at the base of the receiver.
- Position the receivers backplate against the wall, fixing it into place using the screws provided
- Terminate the cables on the receiver as shown in the wiring diagram (section 4.2.2).
- Caution: Before any installation and/or maintenance, ensure that the electrical supply is switched off at the breaker.
- Mount the front panel back onto the back plate, and tighten the retaining screws on the base.
- Switch on the power supply, the power LED will illuminate.
Wiring
- Connect the 230V mains supply and load cable into the backplates terminals which are marked below.
- Caution: Before any installation and/or maintenance, ensure that the electrical supply is switched off at the breaker.
- Elite Security Products UK, Unit 7 Target Park, Shawbank Road, Lakeside, Redditch, Worcestershire, B98 8YN Tel: +44(0) 1527 51 51 50 Fax: +44(0) 1527 15 01 43
- Email:info@espuk.com Registered in England; Company Registration Number: 02769392
- VAT Registration: GB614686525
- For more product information please visitwww.espuk.com
- E &OE – Errors and Omissions Excepted. A24
Read User Manual Online (PDF format)