ZHILIAN R01 Health Smart Ring Instructions
- August 13, 2024
- Zhilian
Table of Contents
ZHILIAN R01 Health Smart Ring
Statement
Please note that the ring service is not intended to diagnose, treat or prevent any disease or medical condition, the information and data in the service are for informational purposes only and are not intended to replace the services of a health professional or physician. If you have any questions about your medical condition, it is recommended to consult a professional physician.
Product Specification
- Ring Dimension :18mm, 20mm,22mm,24mm (4 kinds of size specifications).
- Material : Stainless steel outer ring + epoxy resin inner ring.
- Storage capacity : It is recommended to connect to the app and synchronize data every day. The ring can store up to 7 days of data, depending on the type and frequency of use.
- Product weight : about 4.0 grams.
- Battery capacity : 20 mAh polymer lithium battery.
- Battery life : 5 to 7 days, depending on frequency of use.
- Charging method : Magnetic suction charging base.
- Charging time : 1 -1 .5 hour.
- Luminescence sensor. LED are in the visible color range, safe and friendly to the user.
- Connection method : Support Android 6.0 and above version ; apple IOS 11 .0 above version.
- Software program updatable : update via software application.
- Software program compatibility : App store, Google play ,Android system.
- Waterproof level :IP68.
APP Download
Search “Smart Health” in Google play or App Store and download the APP.
Note: Please allow the APP to obtain Bluetooth connection permission and
location permission For the Android version in China, please scan the Q code
on the right to download the APP.
Wear Correctly
Please put the detection sensor (see the inner circle of the ring) in close contact with the skin of the finger pulp to ensure accurate data.
Charging/Power On/Off
Charge
Ring charging : Use the matching charging cable to connect the ring and
the charger. After the power is turned on, the ring indicator light is red and
it is always charging. Status of the indicator lignt: the rea mgnt is always
on airing charging, the green light is always on after Charging.
Charging time :1 – 1.5 hour
Power check : Check the battery power on the power icon in tne upper
rignt corner of the APP main page.
Low battery warning, the red lignt or the ring Tianhe’s, and the APP pops up
warning, prompting that it needs to be charged.
Illustrate
Please keep the charging port dry and free of foreign objects to prevent short circuit failure it is recommended to use a charger with a rated output voltage of 5V.
Power on/ off
Power on : After the ring is fully charged, disconnect the power supply,
and the ring will automatically power on.
Shutdown: Automatically shut down when the power is exhausted.
Bluetooth Connection
After the power is disconnected, the ring will automatically turn on, the
Bluetooth will start broadcasting, the APP will search for the device “R01 “,
and select to connect.
Note: Please turn on the Bluetooth permission and location permission of
the APP.
Blood Oxygen Monitoring
Automatic test : The ring automatically tests the blood oxygen
concentration every 10 minutes, saves the test data, and generates a
historical chart:
Real-time test : Click the “Test” button to actively test the real-time
blood oxygen concentration value and save the latest real-time test data.
Note: Keep sitting still, and the red light on the inner circle of the
ring will keep flashing during blood oxygen monitoring.
Resting Heart Rate Monitoring
Automatic test : The ring automatically tests the resting heart rate
value every 10 minutes, calculates the average heart rate value per hour, and
saves the test data, and produces the history chart:
Real- time test : Click the “Test” button to actively test the real- time
resting heart rate value and save the latest real-time test data.
Note: Keep sitting still, when the heart rate is monitored, the green
light on the inner circle of the ring will continue to flash.
Step Count
Record the number of steps per hour in real time, aenerate a step record
chart, and automatically synchronize the data after connecting to the APP.
Sleep Monitoring
The ring records the complete sleep cycle in rea lime, and teschenitic algorithm analyzes the duration of various stages sucn as waking, lignt sleep, and deep sleep, and generates a record chart.
Ring/ APP Upgrade
The APP automatically detects the version of the ring program. For a better user experience, please upgrade the ring program and the APP program to the latest version.
Common Problem
-
Unable to connect via Bluetooth
Please make sure you have turned on the Bluetooth permission and location permission of the APP ,When the ring has no power or low battery, Bluetooth connection cannot be made, please charge the ring. -
inaccurate data
Please wear the ring correctly, the detection sensor on the inner ring of the ring is in close contact with the skin of the finger pulp. -
The ring has been bound
The ring has a unique 1 D logo. If you need to bind a new APP account, please unbind the ring and the APP account that has been bound. If you forget the APP account, please contact the manufacturer.
Disclaimer
- Normal wear and tear, including scratches and dents.
- Consumable components included in the product, such as batteries.
- Damage caused by using the product without following the instructions.
- Product damage caused by force majeure, such as fire, flood, etc.
- Damage caused by unauthorized, tampering or modification of the product.
Maintenance
- The surface of the ring is smooth ceramic, do not put hard objects together, so as not to scratch the surface of the ring.
- Do not let the ring come into contact with strong acid and alkali chemicals, so as not to cause corrosion.
- The outer ring of the ring is made of ceramics, which is a fragile object and should not be broken by impact.
- Please use neutral solution and soft cloth to clean the dirt.
- The ring contains batteries, please do not expose to high temperature environment for a long time.
FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference, (2) this device must
accept any interference received, including interference that may cause
undesired operation.
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
FCC Caution:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>