Honeywell M39146 L2 WiFi Water Sensor and Switch Installation Guide
- August 11, 2024
- Honeywell
Table of Contents
Honeywell M39146 L2 WiFi Water Sensor and Switch
Product Information
Specifications
- ProductName: L2 WiFi Water Sensor and Switch
- Model Number: M39146
- Power Supply: 24V
- Functions: Water sensing and circuit control
Product Usage Instructions
Before Installation:
- Read the instructions carefully.
- Check if the product is suitable for your application.
- Installer must be a trained, experienced service technician.
- After installation, verify the product operation using the instructions.
App Installation
- Download the Resideo app on your mobile device.
- Sign up for an account and select L2 WiFi Water Sensor and Switch from the device list.
- If you already have an account, add your device from the list.
Connecting the Device
The L2 WiFi Water Sensor and Switch can be wired to 24V equipment to open
or close a circuit when water is sensed. Follow the wiring diagram provided:
Wiring Functions
Color | Description | Wire Function |
---|---|---|
Red (R) | 24V Power Supply | Device Supply |
Black (C) | Power Supply GND | Device Supply |
White (3) | Normally Open | Dry Contact |
Orange (2) | Normally Closed | Dry Contact |
Green (1) | Common | Dry Contact |
Installation Continued
Follow the wiring example to connect the device properly. For further
assistance, refer to additional diagrams or scan the QR code provided.
Frequently Asked Questions (FAQ)
-
Q: Can the L2 WiFi Water Sensor and Switch be used outdoors?
- A: No, this product is designed for indoor use only.
-
Q: What is the maximum distance the sensor can be from the Wi-Fi router?
- A: The sensor can typically operate within a range of up to 100 feet from the Wi-Fi router, depending on obstructions and interference.
L2 WiFi Water
Sensor and Switch
Installation Guide
Online Guides
Included in Box
Before Installation
- Read these instructions carefully. Failure to follow instructions can damage the product or cause a hazardous condition.
- Check the product information to see if product is suitable for your application.
- Installer must be a trained, experienced service technician.
- After completing installation, use these instructions to verify the product operation.
Download App
- Download the Resideo app onto your mobile device.
- Launch the app and sign up for an account. Select L2 WiFi Water Sensor and Switch from the device list.
Note: If you already have an account, tap the add button and select your device from the list.
Connect to App
Follow instructions in app to complete setup.
Installation
Wire Device
L2 WiFi Water Sensor and Switch can be wired to 24V equipment, so that when
water is sensed, the sensor either opens or closes a circuit. Typical
applications include preventing HVAC condensation pan overflow, turning on
water pump when water is sensed, etc.
Connect wiring as shown in the following wiring diagram. For additional
diagrams, scan the QR code at the right. Wires may be extended if needed using
provided wiring nuts.
Wiring Example
L2 locks out compressor when wet.
- C wire is optional or not used on some thermostats.
- System types vary. Wire the W, G, etc. as normal from the thermostat to HVAC.
- If Y2 is used, or the system is zoned, see the diagrams in the online file using the QR code.
Note: Use caution if locking out heating in locations in which pipes could freeze.
For More Application Examples…
Go to:
https://customer.resideo.com/resources/techlit/TechLitDocuments/33-00000S/33-00631EFS.pdf
Water Sensor and Switch Diagram
Placement and Sensing **
**
Do not submerge sensor in water
Wall Mounting
Device can be installed on a wall while using the optional cable sensor.
Floor Placement
Device can be placed on the floor using the on-device water sensing contacts
and the optional cable sensor.
Note: For WiFi operation, device cannot be mounted inside a metal box.
Optional Cable Sensor
To install the cable sensor, remove the plug at the bottom of the device and
plug in the cable sensor.
Accessory cable sensors (WLD3CABLE sold separately) can be connected to extend the cable and increase water sensing area. The entire length of the cable is a water sensor.
Note: The cable sensor jack is NOT for plugging in an adaptor. Doing so could damage the water sensor.
When a Leak is Detected
To Silence Alerts
- Press the sensor’s button or tap the mute button in the app to mute the siren.
- After you’ve addressed the cause of the alert, remove sensor and cable sensor from water and wipe dry.
Test Mode
- Press button 1s to wake device solid blue LED (connected) or white LED (not connected).
- Then press the button three times. The LED should start blinking red.
- In test mode, alarm sounds and switches change position. (Switch for Orange and Green wires open. Switch for White and Green wires closed.)
- To return to normal function, press the reset button 3 more times.
- Test mode will not function during an active alarm or a firmware update.
Specifications
- Part Number : TWLD3005-001
- Operating Temperature: 32 °F to 140 °F (0 °C to 60 °C)
- Operating Humidity: 5 to 95% Non-Condensing
- S hipping Temperature: -22 °F to 158 °F (-30 °C to 70 °C)
- Shipping Humidity: 10 to 95% Non-Condensing
- Buzzer Alarm SPL: 100 dBA @ 10cm
- Physical Dimensions: 3.9 x 2 x 1.1 in (99.4 x 52.4 x 28.6mm)
- Color: Grey/White
- Standards : UL/CSA 6073
- Supply Voltage : 24VAC/VDC
- Switches Rating : 24VAC/VDC
- Maximum Voltage : 24VAC/VDC
- Maximum Current : 5A Weatherproofing: IP44
- Action : Type 1 SELV Class 2
- Control Pollution Degree : 2
- Rated Impulse Voltage : 330V
- Purpose of Control: Operating electronic appliance control
- Construction of Control: Independently mounted control
Lighting Functions
LED Light Light Color Light Behavior Device Status
M39154
| Installation
White| Solid| Awake and ready for BLE pairing. Follow in-app instructions to
connect.
Off| Off| Idle non connected or no power.
Blue| Blinking| Bluetooth pairing mode
Blue| Solid| Paired with bluetooth
Green| 2 Blinks| Connection success
Red| 3 Blinks| Connection failure
In Use
Red| Blinking| Detected a leak
Red| Blinking| Factory resetting
White| Blinking| Firmware updating
Red| Blinking| Test mode
Green| Solid| Awake and connected
Off| Off| Idle Connected or no power.
NOTE: Device may be used for water sensing, siren, and relay action without pairing.
FCC Regulations
§ 15.19 (a)(3)
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
IC REGULATIONS RSS-GEN
This device complies with Industry Canada’s license-exempt RSSs. Operation is
subject to the following two conditions
- This device may not cause interference; and
- This device must accept any interference, including interference that may cause undesired operation of the device.
FCC Warning (Part 15.21) (USA only)
Changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
RESIDEO-Extended Producer Responsibility
The product should not be disposed of with other household waste. Check for
the nearest authorized collection centers or authorized recyclers. The correct
disposal of end-of-life equipment will help prevent potential negative
consequences for the environment and human health.
FCC Note
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
ISED Statement
This equipment complies with FCC and ISED radiation exposure limits set forth
for an uncontrolled environment. This equipment should be installed and
operated with a minimum distance of 20 cm between the radiator and a human
body.
Troubleshooting
-
Device not Powering On
Check wiring connections and ensure wires are connected to the proper terminals. -
Bluetooth Pairing Failed
If bluetooth pairing fails at any stage, perform a factory rest. -
Factory Reset
Press and hold button for 15s until solid red LED and two beeps, indicates reset in progress. Once LED is off, reset is complete. -
Resideo Technologies, Inc.
-
1985 Douglas Drive North, Golden Valley, MN
-
55422 1-800-468-1502
-
33-00625EFS—04 SA 03-24
© 2024 Resideo Technologies, Inc. All rights reserved.
This product is manufactured by Resideo Technologies, Inc. and its affiliates.