Honeywell QuickSTEAM Warm Moisture Humidifiers Owner’s Manual

August 11, 2024
Honeywell

Honeywell-logo

Honeywell QuickSTEAM Warm Moisture Humidifiers

Product Information

Specifications

  • Model: HWM331
  • Output Per Day: 3 US Gallons (11.3 Liters)
  • Type: Warm Moisture Humidifier
  • Parts: Medicine Cup, Power Unit, Mist Grille, Tank Handle, Water Tank, Mineral Absorption Pad, Base, Fill Cap, Removable Water Tray, Mineral Reservoir, Heating Plate

Product Usage Instructions

Safety Instructions
Before using the humidifier, ensure to read and save the safety instructions provided in the manual. Some key safety precautions include

  • Place the humidifier on a firm, flat, and level surface.
  • Avoid placing the humidifier on surfaces that could be damaged by water.
  • Keep the humidifier away from heat sources.
  • Regularly inspect the power cord for any damage.

How It Works
The warm moisture system in the humidifier heats and purifies water before releasing bacteria-free mist into the room. The key parts of the humidifier include the medicine cup, power unit, mist grille, tank handle, water tank, mineral absorption pad, base, fill cap, removable water tray, mineral reservoir, and heating plate.

Set-Up

  1. Disinfect the humidifier before first use.
  2. Select a firm, level location at least six inches from any wall for proper air flow.
  3. Place the humidifier on a water-resistant surface to prevent damage.
  4. Keep the box for end-of-season storage.

Mineral Absorption Pad Instructions
To prevent mineral buildup on the heating plate, use mineral absorption pads. Be cautious of hot surfaces to avoid burns. These pads help trap minerals from the water supply and maintain the humidifier’s performance.

FAQ

  • Q: How often should I clean the humidifier?
    • A: It is recommended to clean the humidifier regularly, especially before and after each season of use.
  • Q: Can I use essential oils in this humidifier?
    • A: No, it is not recommended to use essential oils in this humidifier as it may damage the unit.
  • Q: What should I do if the humidifier stops producing mist?
    • A: Check if the water tank is properly filled and that all parts are clean and functioning correctly.

This Owner’s Manual is provided and hosted by Appliance Factory Parts.

Appliance Factory Parts
Experts in BBQ, Humidifier, & Appliance Parts
1-800-955-7075

HONEYWELL HWM331 Owner’s Manual
Shop genuine replacement parts for HONEYWELL HWM331
Find Your HONEYWELL Humidifier Parts – Select From 153 Models

Manual continues below

OWNER’S MANUAL
3 US GALLONS (11.3 LITERS) OUTPUT PER DAY
WARM MOISTURE HUMIDIFIERS

Models

  • HWM-330
  • HWM-331
  • HWM-335

4 US GALLONS (15.1 LITERS) OUTPUT PER DAY
WARM MOISTURE HUMIDIFIER

Model
HWM-450

The Honeywell trademark is used by Kaz, Inc. under license from Honeywell Intellectual Properties, Inc.

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS HUMIDIFIER

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:

  1. Always place this humidifier on a firm, flat and level surface. This humidifier may not work properly on an uneven surface.
  2. Do not place humidifier directly on wood furniture or other surfaces that could be damaged by water.
  3. CAUTION : To reduce the risk of severe burns, place this humidifier in an area where it is not accessible to children.
  4. Do not place the humidifier near any heat sources such as stoves, radiators, and heaters.
  5. Before using the humidifier, check the power cord for any signs of damage. If the cord is found to be damaged, DO NOT USE and return the humidifier to the manufacturer under the warranty agreement for repair.
  6. This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of shock, this plug is intended to fit only one way in a polarized outlet. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature.
  7. To disconnect the humidifier, first turn controls to the OFF position, then grip the plug and pull it from the wall outlet. Never pull by the cord.
  8. A loose fit between the AC outlet (receptacle) and plug may cause overheating and a distortion of the plug. Contact a qualified electrician to replace loose or worn outlet.
  9. The humidifier should always be unplugged and emptied when not in operation or while being serviced or cleaned.
  10. Never tilt or attempt to move the humidifier while it is operating or filled with water. UNPLUG the humidifier before moving.
  11. This humidifier requires regular cleaning. Refer to the CLEANING instructions provided. Never clean the humidifier in any manner other than as instructed in this manual. You may have to clean your unit once per week or more depending on the mineral content of your water.
  12. Do not immerse the base in water or other liquid. Do not pour water in the humidifier outlet.
  13. Do not direct steam directly at individuals, walls or furniture.
  14. When a humidifier is used in a closed room or small rooms, check periodically for proper ventilation, as excessive humidity can cause condensation stains on walls.
  15. Do not attempt to remove Medicine Cup, Power Unit, Water Tank, Water Tray or Mineral Absorption Pad during operation, or within 10-15 minutes after the humidifier has been turned “off” and unplugged. Serious injury may result. The Water Tray and Mineral Absorption Pad should only be removed for cleaning and maintenance purposes.
  16. DO NOT touch the steam vapor. Steam can cause severe burns.
  17. DO NOT block the mist grille. This will damage the humidifier.

Introduction

HOW DOES IT WORK?
QUICK STEAM WARM MOISTURE SYSTEM:
Water passes into the unit where it is heated and purified by the QuickSTEAM™ heating plate. The unit then pulls the air through the top vent and spreads invisible, bacteria-free mist into the room.

Your humidifier is made up of these parts

Honeywell-QuickSTEAM-Warm-Moisture-Humidifiers-image
\(1\)

Set-Up

NOTE: We recommend that the humidifier be disinfected prior to first use. Please see CLEANING INSTRUCTIONS.

Select a firm, level, flat location – at least six inches (15 cm) from any wall or object for proper air flow (Fig. 1). Place the humidifier on a water- resistant surface, as water can damage furniture and some flooring.

Kaz will not accept responsibility for property damage caused by water spillage.

  • Remove the Water Tank by grasping handle and pulling straight up (Fig. 1). Set aside.
  • Remove the Power Unit by grasping it and lightly tilting forward while pulling up. You will feel the unit disengage from its lock (Fig. 2). Set the Power Unit aside.
  • Remove the Water Tray (Fig. 3). Set the Water Tray aside.
  • Place one Mineral Absorption Pad flat on the Heating Plate. See the MINERAL ABSORPTION PAD section (page 5) for more information.
  • Replace the Water Tray.
  • Replace the Power Unit, making sure it is installed properly. Align the back of the Power Unit directly behind the tabs of the Base and press down firmly. You will hear a slight click. Your Power Unit will be flush with the Base (Fig. 4).
  • Fill the Water Tank with cool tap water (Fig. 5). See the FILLING section (page 5) for more information.

NOTE: Save your box for end of season storage. (See END OF SEASON CARE AND STORAGE section.)

Mineral Absorption Pad Instructions
CAUTION: HOT SURFACES MAY CAUSE SEVERE BURNS. DO NOT TOUCH ANY SURFACES UNTIL THEY HAVE COOLED.

Water contains minerals and other particles. The amount of minerals varies dependent on your local water supply. It is common for these minerals to stick to your humidifier’s Heating Plate and in turn decrease the performance of your humidifier. Mineral Absorption Pads trap the minerals and help prevent stubborn mineral buildup on your Heating Plate.

  • Before starting your humidifier, place one Mineral Absorption Pad flat on the Heating Plate. After the humidifier has been operating, the water and all internal parts will become HOT, and caution should be exercised when handling the Mineral Absorption Pad. Please allow the humidifier water and all internal parts to cool down (at least 10-15 minutes). Use tongs or long tweezers when handling the pad to prevent burns.
  • The life of the Mineral Absorption Pad will vary, depending on the mineral content of the water being used. Using normal/moderate mineral content water the Mineral Absorption Pad should be changed after approximately 2 weeks of continuous use. Again, the life of the pad will vary dependent on your usage and mineral content of your water.
  • For indications that your Mineral Absorption Pad needs to be changed, examine it AFTER the water has cooled down to see if it is still soft and pliable. If the pad is stiff and hard you should replace it. Another sign that indicates your Mineral Absorption Pad must be changed is scale buildup on your heating plate.

Filling

  • Remove the Water Tank by grasping handle and pulling straight up. Set aside (Fig. 1).

  • Turn the Water Tank upside down so that the Fill Cap is facing up; unscrew the Fill Cap by turning it counter-clockwise and set aside.

  • Fill the Water Tank with COOL tap water (Fig. 5). DO NOT USE HOT WATER. Doing so may damage the humidifier.

  • Distilled water is not necessary but should be considered in hard water areas to prevent mineral build-up.

  • Replace the fill cap by turning it clockwise
    DO NOT OVER-TIGHTEN. Turn the Water Tank right-side up.
    NOTE: Do not add any medication or other additives to water.
    NOTE: When carrying the filled Water Tank, please use the handle and place your other hand under the tank for additional support.

  • Position the Water Tank in the humidifier and push into place (Fig. 6).

  • Some water will flow into the Removable Tray when the filled Water Tank is properly in place.

  • Once the filled Water Tank has been positioned, do not attempt to move the humidifier. To avoid leaking, you should never move the humidifier while filled with water.

CAUTION: Do not pour water into the grille on the top of the humidifier. Doing so may damage the humidifier or cause personal injury.

Manual Control Operation (Models HWM-330 and HWM-331)

POWER
CAUTION: DO NOT PLUG IN THE HUMIDIFIER WITH WET HANDS AS AN ELECTRICAL SHOCK COULD OCCUR.

With the power switch in the OFF position, plug the filled humidifier into a polarized 120V outlet. DO NOT FORCE THE POLARIZED PLUG INTO THE OUTLET; it will only fit one way.

OUTPUT / MOISTURE CONTROL

Set the Moisture Control knob to the desired position (Fig. 7).

  • HIGH: For fast humidifying
  • LOW: For everyday moisture control

Continuous Mode – Your unit will run continuously at your selected output level until you shut it off or it runs out of water.

ADVANCED MIST™ HUMIDISTAT
The Advanced Mist™ Humidistat allows you to adjust and select the humidity level to your personal preference. Your humidifier will turn on and off throughout the day and night to maintain the desired humidity level you have selected.

HOW TO SET THE HUMIDISTAT
First, turn the Humidifier on and select your moisture/output level. Set the Advanced Mist™ Humidistat on HIGH by turning the knob clockwise to the end (Fig. 7).

  • Let the humidifier run on high for a least one hour or until your room has reached a comfortable humidity level.
    At this point, slowly turn your Humidistat knob counter-clockwise until the humidifier shuts off  (Fig. 8).

  • Now that your Humidistat knob is set, the humidifier will automatically turn back on when your room drops below your comfort setting and will automatically turn off again when the setting is reached.

NOTE: If the humidifier will not start or restart when you select a moisture level, the Advanced Mist™ Humidistat may be set too low. Turn the dial clockwise to the end (Fig. 7).

REFILL / CLEAN HUMIDIFIER

  • When the Refill/Clean indicator light is illuminated it implies your unit is out of water or you need to clean your humidifier (Fig. 9).
  • Check your water level. If your Tank is empty, turn your Power knob to the OFF position, remove the Tank and refill it as described in the FILLING section.
  • If your water level is full, this implies it’s time to clean your humidifier. Please turn off and unplug the unit and refer to the CLEANING section.

NOTE: Your unit’s performance will decrease if you do not clean your heating plate. Your unit may continuously shut off and output will decrease.
NOTE: Do not turn on the unit until the tank is refilled and reinstalled.

Manual Control Operation (HWM-331)
NOTE: This product is equipped with a Vapor Mist Sensor Badge Fig. 10 (Fig 10). When the Vapor Mist Sensor Badge located on the medicine cup, turns from grey to blue warm moisture is being emitted from the humidifier. Do not touch the medicine cup or warm moisture outlet grille unless the unit has been turned off and the Vapor Mist Sensor Badge has turned back to grey.

Honeywell-QuickSTEAM-Warm-Moisture-Humidifiers-image
\(13\)

EasySet™ Control Operation (Model HWM-335)

POWER
CAUTION: DO NOT PLUG IN THE HUMIDIFIER WITH WET HANDS AS AN ELECTRICAL SHOCK COULD OCCUR.

With the power OFF, plug the filled humidifier into a polarized 120V outlet. DO NOT FORCE THE POLARIZED PLUG INTO THE OUTLET; it will only fit one way.

STEP 1: POWER

  • Press the Power button to start the humidifier. Your humidifier will automatically start on High power, continuous run (Fig. 11).
  • To turn your humidifier OFF simply press the Power button again.

STEP 2: OUTPUT / MOISTURE CONTROL
Your unit has three output/moisture levels

HIGH: For fast humidifying
MED: For everyday moisture control
LOW: For minimum operation (ideal for nighttime use)

  • Push the Up button (+) to increase output level and push the Down button (-) to decrease output level. The LED’s will illuminate to reflect which level you have selected (Fig. 12).
  • Continuous Mode: Your unit will run continuously at your selected output level until you shut it off or it runs out of water.

STEP 3: SET HUMIDITY

  • Set your desired humidity anywhere between 35% and 55%.

  • Push the Up button (+) to increase desired humidity and push the Down button (-) to decrease desired humidity. The LED’s will illuminate to reflect which desired humidity level you have selected (Fig. 13).
    For example: If you set your humidity at 40%, the 35% and 40% LED’s will be illuminated.

  • Once you have set your desired humidity, the unit will operate under this desired setting until the unit is turned off.

  • When the desired room humidity has been reached the unit will automatically shut off. (The humidity LED’s will remain illuminated.)

  • Your unit will turn back on when your room decreases beyond your set level.

NOTE: Your room humidity can often fluctuate. It is normal for your unit to turn itself on and off throughout the day as it is monitoring your changing environment.

To go back to Continuous Mode, turn your unit off and then back on and select your desired output setting (see Step 2).

EasySet™ Control Operation (Model HWM-335) cont’d.

REFILL / CLEAN INDICATOR

  • When the Refill/Clean indicator light is illuminated it implies your unit is out of water or you need to clean your humidifier (Fig. 14).
  • Check your water level. If the Tank is empty, remove the Tank and refill it as described in the FILLING section.
  • Press the Reset button to restart the humidifier after the Tank is reinstalled.
  • The humidifier will then resume to its previous settings.
  • If the water level is full, this implies it’s time to clean your humidifier. Please turn off and unplug the unit and refer to the CLEANING section.

NOTE: Do not press the Reset button until the Tank is refilled and reinstalled.

NOTE: Your unit’s performance will decrease if you do not clean your Heating Plate. You unit may continuously shut off and output will decrease.

Honeywell-QuickSTEAM-Warm-Moisture-Humidifiers-image
\(17\)

Digital EasySet™ Control Operation (Model HWM-450)

POWER
CAUTION: DO NOT PLUG IN THE HUMIDIFIER WITH WET HANDS AS AN ELECTRICAL SHOCK COULD OCCUR.

With the power OFF, plug the filled humidifier into a polarized 120V outlet. DO NOT FORCE THE POLARIZED PLUG INTO THE OUTLET; it will only fit one way.

STEP 1: POWER

  • Press the Power button to start the humidifier. Your humidifier will automatically start on High power, continuous run. The display will be illuminated and will reflect the current room humidity (Fig. 15).
  • To turn your humidifier OFF simply press the Power button again.

STEP 2: OUTPUT / MOISTURE CONTROL
Your unit has three output/moisture levels

HIGH: For fast humidifying
MED: For everyday moisture control
LOW: For minimum operation (ideal for nighttime use)

  • To change your moisture level, press the moisture control button up or down (Fig. 16).
  • Once you have selected your moisture level the display will go back to showing the current room humidity after 3 seconds.

Honeywell-QuickSTEAM-Warm-Moisture-Humidifiers-image
\(19\)

NOTE: If you wish to change or check your output/moisture setting simply press the Moisture Control button once and it will show you your setting. If you would like to change it, continue to push the button up or down until you have reached your desired setting. Again, after 3 seconds the display will revert to showing the current room humidity.
Continuous Mode: Your unit will run continuously at your selected output level until you shut it off or it runs out of water.

STEP 3: TIMER CONTROL
You can set your Timer for up to 18 hours. This function should only be used if you desire that the humidifier be automatically shut off after a certain period of time.

Digital EasySet™ Control Operation (Model HWM-450) cont’d.

  • Press the Timer button up or down to set how many hours you would like the humidifier to run (Fig. 17).
  • When the display indicates your desired time, wait 3 seconds.
  • After 3 seconds, your desired time is set and the display will revert back to showing the current room humidity.

NOTE: If you wish to change your Timer setting or check to see how much time is left simply press the Timer button once and it will show you the time left. If you want to change the time remaining, continue to push the button up or down until you have reached your desired time. Again, after 3 seconds the display will revert to showing the current room humidity.

STEP 4: SET HUMIDITY

  • You can set your desired humidity in 1% increments anywhere from 25% to 65%.
  • To set your desired humidity, press the Humidity button up  or down (Fig. 18).
  • When the display indicates your desired humidity setting wait 3 seconds.
  • After 3 seconds your desired humidity is set and the display will revert back to showing the current room humidity.

NOTE: If you wish to change your Humidity setting or check to see what you set, simply press the Humidity button once and it will show you the set humidity. If you want to change it, continue to push the button up or down until you have reached your new desired humidity. Again, after 3 seconds the display will revert to showing the current room humidity.

  • Once you have set your humidity the unit will operate under this desired setting until the unit is turned off.
  • When your desired room humidity has been reached your unit will shut off and the House Icon on the top of your display will illuminate (Fig. 19). It will stay illuminated until your desired humidity decreases at which time your unit will turn back on.

NOTE: Your room humidity can often fluctuate. It is normal for your unit to turn itself on and off throughout the day as it is monitoring your changing environment.

REFILL / CLEAN INDICATOR

  • When the Refill/Clean indicator light is illuminated it implies your unit is out of water or you need to clean your humidifier.
  • Check your water level. If your Tank is empty, remove the Tank and refill it as described in the FILLING section.
  • Press the Reset button to restart the humidifier after the Tank is reinstalled (Fig. 20).
  • The humidifier will then resume to its previous settings.
  • If your water level is full, this implies it’s time to clean your humidifier. Please turn off and unplug the unit and refer to the CLEANING section.

NOTE: Do not press the Reset button until the Tank has been refilled and reinstalled.

NOTE: Your unit’s performance will decrease if you do not clean your heating plate. Your unit may continuously shut off and output will decrease.

Medicine Cup

CAUTION: HOT STEAM MAY CAUSE SEVERE BURNS
DO NOT TOUCH THE MEDICINE CUP UNTIL IT HAS COOLED.

Soothing vapor can be distributed into the air by using the Medicine Cup at the top of the unit. To add medicine to the Medicine Cup

  • Turn the humidifier OFF and wait 10 minutes for the unit to cool.
  • Remove the Medicine Cup from the unit by pulling firmly upward (Fig. 21).
  • Fill the cup halfway with liquid medicine. Only place the medicine in the small oval area. Do not put medicine in the grille area.
  • Carefully reinstall the Medicine Cup back into the unit.
  • After use, remove and clean the Medicine Cup with warm water. Reinstall the clean and dry Medicine Cup into the unit.

WARNING: DO NOT use any liquid medicines other than those specifically recommended for use with steam vaporizers or warm HUMIDIFIERS. DO NOT pour medicine through the front or side grilles or add it to the water tank.

Kaz assumes no responsibility for consequences resulting from the use of medicine in this humidifier.

Weekly Cleaning

CAUTION: DO NOT CLEAN THE HUMIDIFIER WITH THE POWER CORD PLUGGED IN THE ELECTRICAL OUTLET AS AN ELECTRICAL SHOCK COULD OCCUR.

We recommend cleaning the humidifier once a week. It may require cleaning more often if you have hard water, notice a build up of impurities or detect unpleasant odors. The importance of routine cleaning and care cannot be over emphasized.

Cleaning involves two steps: SCALE REMOVAL and DISINFECTING. Be sure to perform these in the proper order to avoid harmful chemical interactions.

First, turn off and unplug the humidifier. Wait at least 10-15 minutes for the unit to cool.

  • Remove the Water Tank.
  • To remove the Power Unit, grasp the Power Unit and lightly tilt forward while pulling up. You will feel the unit disengage from its lock (Fig. 22). Set the Power Unit aside.
  • Remove the Water Tray (Fig. 23) and set aside. Be sure to thoroughly clean the Water Reservoir in the Base. Minerals often accumulate in this area, so special attention should be used.
  • Empty any water from the Base and Removable Tray.
  • Be sure the Heating Plate has cooled sufficiently.

Remove the Mineral Absorption Pad using tweezers or tongs and check the condition of the Mineral Absorption Pad and the Heating Plate found on the Base. If build-up of minerals is heavy, follow the Cleaning the Heating Plate instructions.

CAUTION: DO NOT SUBMERGE THE BASE IN WATER. DOING SO MAY CAUSE PROPERTY DAMAGE OR PERSONAL INJURY. ALLOW THE HUMIDIFIER TO DRY COMPLETELY BEFORE PLUGGING INTO POWER OUTLET.

Weekly Cleaning cont’d.

STEP ONE

SCALE REMOVAL

Removable Tray

  1. Fill the Removable Water Tray (Fig. 3) with:
    • 1 cup (8 oz.) of undiluted white vinegar
  2. Let solution stand for 20 minutes.
  3. With the vinegar in the Removable Tray, clean all interior surfaces with a soft cloth or brush to help remove scales.
  4. Rinse the Removable Tray thoroughly with water to remove scale and cleaning solution.

STEP TWO:
DISINFECTING
Water Tank/Removable Tray

  1. Fill the Water Tank with:

    • 1 teaspoon of household bleach and
    • 1 gallon of water
      Pour some of this solution into the Removable Tray.
  2. Let solution stand for 20 minutes.

  3. Rinse with water until the smell of bleach is gone.

NOTE: Removable Water Tray and Medicine Cup are top shelf dishwasher safe.

NOTE: THE USE OF OTHER WATER TREATMENT PRODUCTS, CHEMICALS, SOAPS, DETERGENTS OR ABRASIVE CLEANSERS NOT RECOMMENDED IN THIS MANUAL MAY CAUSE DAMAGE TO THE HUMIDIFIER OR AFFECT PERFORMANCE.

Cleaning the Heating Plate

  • CAUTION: HOT SURFACES MAY CAUSE SEVERE BURNS. DO NOT TOUCH ANY SURFACES UNTIL THEY HAVE COOLED.
  • CAUTION: DO NOT CLEAN THE HUMIDIFIER WITH THE POWER CORD PLUGGED IN THE ELECTRICAL OUTLET AS AN ELECTRICAL SHOCK COULD OCCUR.

If the output drops, or the Refill/Clean light remains on, even while there is water in the tank, the mineral build-up may need to be removed from the Heating Plate and the Mineral Reservoir. You may also have to replace the Mineral Absorption Pad.

How often you perform this special maintenance depends upon the hardness of the water you are using and how quickly mineral deposits form on the interior surfaces of the humidifier.

  1. Turn off and unplug the humidifier. Allow at least 15 minutes for the unit to cool.

  2. The Heating Plate is on the bottom of the Base. To access it, grasp the Power Unit and lightly tilt it forward while pulling up. You will feel the unit disengage from its lock (Fig. 22). Set the Power Unit aside.

  3. Remove the Water Tray and set aside (Fig. 23).

  4. Remove the Mineral Absorption Pad using tweezers or tongs to prevent burns.

  5. BE SURE THE HEATING PLATE HAS COOLED SUFFICIENTLY. Empty any water from the base and remove mineral debris from the Mineral Reservoir. Be sure to clean the Mineral Reservoir thoroughly.
    Cleaning the Heating Plate cont’d.

  6.  Use a non-metallic brush or soft, dry cloth to wipe the Heating Plate (Fig. 24). The Heating Plate is made of stainless steel so be sure to use non-abrasives. Some deposits may remain, but should not interfere with the operation of the unit.

CAUTION: DO NOT CLEAN THE HEATING PLATE UNDER RUNNING WATER. DOING SO MAY CAUSE PROPERTY DAMAGE OR PERSONAL INJURY.

End-of-Season Care and Storage

  • Follow the CLEANING instructions when the humidifier will not be used for at least one week or more, or at the end of the season.
  • Dry the humidifier completely before storing. DO NOT store with water inside the Removable Tray, Base or Water Tank.
  • Pack the unit in its original carton and store in a cool, dry location.
  • Before next use, remember to clean your humidifier.

Consumer Relations

  • Mail questions or comments to: Please be sure to specify model number
  • Kaz, Inc. . Call us toll-free at: 1-800-477-0457
  • Consumer Relations Dept. E-mail: consumerrelations@kaz.com
  • 250 Turnpike Road Southborough, MA 01772 Or, visit our website at: www.kaz.com

Replacement Mineral Absorption Pads

  • Mineral Absorption Pads:
  • Model Number HMP-12P

Electrical Ratings
The Honeywell QuickSteam™ Series models are rated at 120V, 60 Hz.

NOTE: DO NOT RETURN PRODUCT TO STORE. IF YOU EXPERIENCE A PROBLEM, PLEASE CALL US TOLL-FREE AT 1-800-477-0457. OUR CONSUMER RELATIONS TEAM WILL HELP AND ADVISE NEXT STEPS.

CAUTION: DO NOT OPEN THE POWER UNIT OR BASE YOURSELF. DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE HUMIDIFIER OR PERSONAL INJURY.

Troubleshooting|
---|---
Problem| Possible Cause| Corrective Action
Power| |
Unit is not running, some lights are on| Unit needs cleaning| Clean the unit (Heating Plate, Mineral Ditch, etc.) and change Mineral Absorption Pad as needed
| Unit is out of water| Refill and reinstall Water Tank
| Humidity level set too low| Reset humidity to a higher level
| Unit is too hot| Turn off the power and let the unit cool down
| Power Unit is not installed properly| Reinstall Power Unit
| Unit is not set on level surface| Place the unit on a firm, flat, and level surface
| There is too much moisture inside the unit| Turn off the power and completely dry out the unit
Unit is not running, no lights| Unit is off due to timer| Press Power button
| Power unit is not installed properly| Reinstall Power unit
| Power outage| Press Power button
Humidity level was set but unit does not start| Humidity level set too low| Reset humidity to a higher level
Humidity level was set but unit does not shut off| Humidity level set too high| Reset humidity to a lower level
Tripping the circuit breaker| Too many appliances plugged in the same circuit| Remove excessive appliance(s) or place the humidifier in a different circuit
Light flickering| Electrical interference| Place the humidifier in a different circuit (power outlet)
Sound| |
Crackling, popping sound| Unit needs cleaning| Clean the unit (Heating Plate, Mineral Reservoir, etc.) and change Mineral Absorption Pad as needed
Gurgling sound| Unit is operating normally| None needed
There is no difference in sound between the high and low setting| Unit is operating normally| None needed
Humidity Display| |
Humidity display is too high| Moisture/condensation accumulated in humidity sensor| Turn off the power and completely dry out the unit
| Unit is overfilled with water| Drain the excess water from the base and completely dry out the unit
Humidity display is too low| Unit is too hot| Turn off the power and let the unit cool down
Condensation| |
Condensation forming

on the walls and/or windows

| Humidity level set too high| Reset humidity to a lower level and/or reduce the Output level
| Unit is placed too close to the wall and/or windows| Relocate the unit
Steam/condensation coming out of the front grill| Unit is overfilled with water| Drain the excess water from the base and completely dry out the unit

3 Year Limited Warranty

You should first read all instructions before attempting to use this product.

  • This 3 year limited warranty applies to repair or replacement of product found to be defective in material or workmanship. This warranty does not apply to damage resulting from commercial, abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under
    this warranty.
    KAZ IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY.
    Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.

  • At its option, Kaz will repair or replace this product if it is found to be defective in material or workmanship. Defective product should be returned to the place of purchase in accordance with store policy. Thereafter, while within the warranty period defective product may be returned to Kaz.

  • This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual.

  • Return defective product to Kaz, Inc. with a brief description of the problem. Include proof of purchase and a $10 US/$15.50 CAN check or money order for handling, return packing and shipping charges. Please include your name, address and a daytime phone number. You must prepay shipping charges. Send to:

In U.S.A.

  • Kaz, Inc.
  • Attn: Returns Department
  • 4755 Southpoint Drive
  • Memphis, TN 38118
  • USA

In Canada

  • Kaz, Inc.
  • Attn: Returns Department
  • 510 Bronte Street South
  • Milton, ON L9T 2X6
  • Canada

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Honeywell User Manuals

Related Manuals