BALLUF BLA BLA 50D-001-S115 Photoelectric Sensor Datasheet
- August 8, 2024
- BALLUF
Table of Contents
Photoelectric Sensors
BLA 50D-001-S115
Order Code: BLA000A
- Receiver, 2) Display and control panel, 3) Emitter
Basic features
Additional features| Object number binary coded on 3
switching outputs
---|---
Approval/Conformity| CE
WEEE
cULus
UKCA
Basic standard| IEC 60947-5-2
Principle of operation| Light array
Scope of delivery| Holding system Connection cable (emitter –
receiver) Manual Cable
Series| D
Style| Square
Straight connection
Display/Operation
Adjuster | Key (4x) |
---|---|
Display | Run – LED green |
CCD signal – OLED display
Setting menu – OLED display
Measuring mode – OLED display
Analog meas.val. – OLED displ.
Object in meas. field – LED orange
Object mode – OLED display
Object number – OLED display
Object visualization – OLED display
Meas.field limits – OLED disp
Setting
Measurement mode (2 independent measurement values)
Object mode (digital values) Meas.field limits Factory setting (Reset) Output
active/inactive Analog output V/I Teach in objects (max. 6) Switching output
PNP/NPN Read direction of the OLED display Contrast of the OLED display OLED
display on/off Normalize CCD signal Calibrate analog outputs Align via CCD
signal disp. Signal scaling Setting block Averaging mode Object detection
tolerance
Electrical connection
Connection | Connector, M12x1-Male, 4-pin |
---|---|
Connection 2 | M12x1-Female, 4-pin, A-coded |
Connection 3 | M12x1-Male, 8-pin, A-coded |
Contact, surface protection | Gold plated |
Polarity reversal protected | yes |
Protection against device mix-ups | yes |
Short-circuit protection | yes |
Electrical data
Load resistance RL max. (Analog I) | 500 ohms |
---|---|
Load resistance RL min. (Analog V) | 1 kOhm |
No-load current Io max. at Ue | 100 mA |
Operating voltage Ub | 15…30 VDC |
Rated insulation voltage Ui | 75 V DC |
Rated operating current Ie | 100 mA |
Rated operating voltage Ue DC | 24 V |
Ready delay tv max. | 300 ms |
Ripple max. (% of Ue) | 10% |
Environmental conditions
Ambient temperature | 5…55 °C |
---|---|
EN 60068-2-27, Shock | Half-sinus, 30 g , 11 ms, 3×6 |
EN 60068-2-6, Vibration | 10…55 Hz, amplitude 1 mm, 3×30 min |
IP rating | IP54 |
Functional safety
MTTF (40 °C) | 30 a |
---|
Interface
Analog output | 2x Analog, voltage/Analog, current 0…10 V/4…20 mA |
---|---|
Switching output | 3x PNP/NPN normally open (NO) |
Material
Housing material | Aluminium, Anodized |
---|---|
Housing material, surface protection | Anodized |
Material sensing surface | Glass |
Surface protection | Anodized |
Mechanical data
Mounting part | Screw M4 |
---|
Optical features
Ambient light max. | 5000 Lux |
---|---|
Average power Po max. | 90 µW |
Beam characteristic | Collimated light strip, width 54 |
mm
Laser class per IEC 60825-1| 1
Light type| Laser red light
Principle of optical operation| Through-beam sensor
Pulse frequency| 0.01…1 kHz
Pulse power Pp max.| 0.2 mW
Smallest part typ.| Wire Ø 0.3 mm at R0 ≤ 0.25m
Wire Ø 0.5 mm at R0 ≤ 1m
Wire Ø 1.0 mm at R0 ≤ 2m
Special optical feature| CCD technology
Wave length| 650 nm
Range/Distance
Accuracy| ±30 µm (R0≤0.25m)
60 µm (R0≤1m)
100 µm (R0≤2m)
---|---
Active length AL 1| 50 mm
Range| 0…2 m
Rated operating distance Sn| 2 m
Repeat accuracy| 15 µm (R0 ≤ 0.25 m)
20 µm (R0 ≤ 1 m)
70 µm (R0 ≤ 2 m)
Resolution| ≤ 0.01 mm
Remarks
For additional information, refer to user’s guide.
Do not press key using a pointed tool.
Reference object (target): Steel cylinder diameter 8.0 mm.
For more information about MTTF and B10d see MTTF / B10d Certificate
Indication of the MTTF- / B10d value does not represent a binding composition
and/or life expectancy assurance; these are simply experiential values with no
warranty implications. These declared values also do not extend the expiration
period for defect claims or affect it in any way.
Connector Drawings
Wiring Diagrams
Help Views
- Object mode digital outputs
- Measuring mode analog out1
- Measured value analog out1
- Scroll / increase value
- LED 2 – Object detected
- Menu, confirm selection
- Discard selection, back
- LED 1 – Operating voltage
- Scroll / Reduce value
- Vis. meas. field – blank.
- Measured value analog out2
- Measuring mode analog out2
- Vis. meas. field – object
- Vis. meas. field – autobl.
- No. of identified object
Opto Symbols
Warning Symbols
LASER CLASS 1 per IEC 60825-1
Internet
www.balluff.com
eCl@ss 9.1: 27-27-08-01
Subject to change without notice: 269897
ETIM 6.0:
BLA000A_0.72_2023-12-20
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>