SARGENT 351 Door Closers with PS/PSH Arms
Specifications
- Adjustable size: 1 thru 6
- Non-handed closers
- Recommended door closing time : 6 seconds for doors opened to 90 degrees
Product Usage Instructions
Determine Door Opening Degree:
Determine the maximum degree of door opening or hold open required.
Door and Frame Preparation:
Drill and tap the door and frame for #12-24 machine screws. Use self-
tapping screws provided or predrill with a 3/32 drill.
Installation Steps:
Follow these steps for installing the door closer:
- Install stop with a 1/4 hex wrench to match the hand of the door.
- Mount foot bracket to the door stop.
- Attach the pre-assembled arm to the stop or door.
Final Adjustment and Regulation:
Adjust the door closer using a 1/8 Hex (Allen) wrench as needed for closing
and latching speeds. Follow these guidelines:
- Closing and latching speeds: Turn valves clockwise to slow down or counterclockwise to speed up door movement.
- Backcheck: Turn the valve clockwise to increase or counterclockwise to decrease the intensity of backcheck action.
- Delayed Action Feature: Turn the valve clockwise to slow down or counterclockwise to speed up door movement within the delayed action range.
FAQ
What should I do if adjustments are ineffective?
If adjustments are ineffective, check indexing from step 4 to ensure proper
functioning of the door closer.
For assistance, contact SARGENT at 800-727-5477 or www.sargentlock.com
INSTALLATION INSTRUCTION
- Determine maximum degree of door opening or hold open (PSH) required. Drill and tap door and frame for #12-24 machine screws. When using self-tapping screws provided, predrill with 3/32″ drill.
DeGRee of DooR oPenInG aT “HoLD oPen” ■
| 85°| 90°| 95°| 100°| 105°| 110°
DIM. “A”| 10-9/16″| 9-7/8″| 9-3/16″| 8-5/8″| 8-1/8″| 7-5/8″
DIM. “B”| 11-5/16″| 10-5/8″| 9-15/16″| 9-3/8″| 8-7/8″| 8-3/8″
Dimensions for given degree based on 4-1/2″ butts. If 3-1/2″ or 6″ hinge is
used, hold open angle will change by less than 1/2°.
Dead stop occurs 3° beyond hold open.
IMPORTANT NOTICE PRE-DRILL 3/32″ HOLES FOR SELFTAPPING SCREWS OR TAP
12-24 FOR MACHINE SCREWS
-
Install door closer to door with spring adjustment nut away from hinge.
NOTE: 351 closer bodies are non-handed. It is important that the closer body is installed with “RH” symbol at top for right hand doors, “LH” symbol at top for left hand doors. -
Install stop with 1/4″ hex wrench to match hand of door. Turn stop counterclockwise until seated very tight.
Mount foot bracket to door stop.
Alternate: Pre-assemble arm prior to attaching to stop
- Rotate bottom spindle 45° with wrench
A ssemble main arm with index mark positioned as shown
Secure with screw and washer
Alternate Method: Attach pre-assembled arm
- Open door and install pivot as shown
Use screw to secure pivot and arms
Accessories
-
OPTIONAL: Use mortise nuts (#4TB when through-bolting is required
-
125 VF Bracket for flush frame and door condition
-
351-D Drop Bracket
Used with narrow top rails -
581-2 Spacer
Used with blade stops -
125 V Bracket for narrow frame condition
Final Adjustment and Regulating Procedures
-
Minimum recommended door closing time is 6 seconds for doors opened to 90 degrees.
-
Use 1/8″ Hex (Allen) wrench to adjust valves as needed.*
-
Closing and latching speeds:
-
Turn valves clockwise to slow down or counterclockwise to speed up door movement.
-
Backcheck:
To regulate the intensity of backcheck action turn valve clockwise to increase or counterclockwise to decrease checking.
CAUTION: SET VALVE FOR SLIGHT CUSHIONING EFFECT. CLOSER CAN BE DAMAGED IF THE CHECKING ACTION IS TOO ABRUPT. NEVER USE THE BACKCHECK AS A DOOR STOP. ALWAYS USE A DOOR STOP TO STOP THE DOOR. -
Delayed Action Feature (optional feature on some models):
“Delayed Action” provides slow door closing through the delayed action range. Turn valve clockwise to slow down or counterclockwise to speed up door movement.
-
-
Adjust power to allow door to close and latch.
Adjusting door to close due to high draft conditions may exceed ADA standards. Consult local ordinances when fire doors are involved.
-
Install cover as shown.
-
To adjust holder arm (PSH only)
All PSH arms are set in hold open at the factory. To inactivate, turn the adjusting nut approximately 1-1/2 turns counter-clockwise. -
NOTES:
-
Reinforce metal doors and frames per ANSI A250-8 and SDl-100 Standards, 12 gauge recommended
-
For thin rail doors, use 351-D plate. See data sheet A6745
-
Left hand door shown. Right hand opposite
-
Dimensions “A” and “B” are based on a 4-1/2″ butt hinge. If a 3-1/2″ or 6″ butt hinge is used, the hold open angle will change by less than 1/2°
-
Dead stop occurs approximately 3° beyond hold open
-
If door closer body interferes with light kit, use 351-B plate.
-
See data sheet A6746 for plate dimensions only
-
When soffit is less than 3″ use 125V bracket
References