Honeywell EWM350 Electric Warm Mist Humidifier Instruction Manual

July 31, 2024
Honeywell

EWM350 Electric Warm Mist Humidifier

“`html

Product Information

Specifications

  • Brand: HONEYWELL
  • Model: EWM350
  • Type: Portable Electric Warm Mist Germ-FreeTM Humidifier
  • Manufacturer: Slant/Fin Corp.
  • Address: 40 Garvies Point Road, Glen Cove, NY 11542

Product Usage Instructions

Important Safeguards

  1. Do not operate the humidifier without the water tanks.

  2. Always use clean, cool tap water to fill the water tanks.

  3. Avoid using an extension cord to prevent the risk of fire or
    shock.

  4. Avoid handling the unit with wet hands.

  5. Do not tilt, move, or attempt to empty the unit while it is in
    operation.

Cleaning and Maintenance

Weekly cleaning is recommended to prevent mineral scale buildup
and ensure efficient operation. Refer to page 6 of the manual for
detailed cleaning instructions.

Control Panel

The power switch has LO and HI positions for adjusting vapor
production rates. The OFF position cuts power to the unit for
maintenance or moving purposes.

UV Bulb Replacement

If the REPLACE UV BULB light is on, replace the UV germicidal
bulb with a 3.5W bulb. The bulb typically lasts 1-2 years of normal
use.

Refill/Clean Indicator

After filling the water tank, reposition it on the base. Clean
the tank and reservoirs regularly to maintain efficiency and
prevent mineral buildup.

FAQ

How often should I clean the humidifier?

Weekly cleaning is recommended for optimal performance.

Can I use any type of water to fill the tanks?

It is recommended to use clean, cool tap water to fill the water
tanks.

What should I do if the UV bulb replacement light comes

on?

Replace the UV germicidal bulb with a 3.5W bulb as instructed in
the manual.

“`

This Owner’s Manual is provided and hosted by Appliance Factory Parts.
HONEYWELL EWM350 Owner’s Manual
Shop genuine replacement parts for HONEYWELL EWM350
Find Your HONEYWELL Humidifier Parts – Select From 153 Models ——– Manual continues below ——–

®
Portable Electric Warm M Germ-FreeTM Model GF-30

Slant/Fin Corp., 40 Garvies Point Road, Glen Cove, NY 11542
®

GF-350 Shown
· Instructions for Operatio · Limited Warranty
READ AND SAVE THE
Printed in CHINA 8/99 Imprimé à CHINA 8/99 Impreso en CHINA 8/99

READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE
ATTEMPTING TO OPERATE YOUR HUMIDIFIER. FOLLOWING
THESE SIMPLE GUIDELINES FOR USE AND CARE WILL HELP
ENSURE YEARS OF DEPENDABLE AND EFFICIENT SERVICE.
IMPORTANT SAFEGUARDS
CAUTION: BECAUSE HIGH TEMPERATURE IS GENERATED IN THIS HUMIDIFIER, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED ESPECIALLY WHEN CHILDREN ARE PRESENT.
WHEN USING ELECTRICAL APPLIANCES, THESE BASIC SAFETY PRECAUTIONS MUST BE FOLLOWED: 1. DO NOT operate the humidifier without the water tanks. 2. ALWAYS use clean, cool tap water to fill the water tanks. 3. To avoid risk of fire or shock, DO NOT use an extension cord. 4. DO NOT handle the unit with wet hands. 5. NEVER tilt, move, or attempt to empty the unit while it is operat-
ing or plugged in. Shut off, unplug and remove water tanks before moving unit. 6. DO NOT place the unit close to heated areas, such as near stoves, heaters or in direct sunlight. 7. DO NOT operate OUTDOORS. This humidifier is intended for indoor use only. 8. DO NOT let water get into the air inlets on the bottom of the enclosure or on the cord or plug. 9. DO NOT store or use gasoline or other flammable vapors and liquids near the humidifier. 10. ALWAYS make sure the water tank caps and gaskets are firmly in place. 11. DO NOT touch hot surfaces. 12. ALWAYS turn the humidifier off when the water tanks are empty or when the unit is not in use. If you turn your unit off for extended periods, ALWAYS disconnect the power cord and empty the water tanks and base. 13. ALWAYS place the unit on a firm flat, level, water resistant surface and arrange the power cord so that the product is unlikely to be upset. 14. DO NOT clean the product or service the UV germicidal bulb without disconnecting the power cord. 15. Before connecting to electric power outlet, check your electrical power supply. It must be 120 volts A.C. (alternating current). The outlet may be 15 amp or 20 amp. The circuit must be of adequate size and must be protected by fuse or circuit breaker.
2

16. This item has a polarized plug. A in a polarized electrical receptac plug does not fit fully in the outle not fit, contact a qualified electri
17. DO NOT attempt to remove STE OR MINERAL ABSORPTION PA minutes after the humidifier is tu unplugged. Serious injury may r PAD, STEAM DIFFUSER AND S removed for cleaning and mainte DO NOT place hands or face dir while unit is in operation.
18. Place unit in an area where it is 19. Before using the unit, check the p 20. This humidifier requires daily an 21. Refer to CLEANING AND MAIN
NEVER clean humidifier in any by this manual.
SAVE THESE IN
GF-350 Shown

WEEKLY CLEANING AND MAINTENANCE ADVISORY
At least weekly cleaning is recommended, when the unit has been in use. Regular cleaning prevents mineral scale buildup in the hot water reservoir. It also helps prevent buildup of bacteria, molds or other microorganisms in the tank or system. This ensures that your humidifier will operate at maximum efficiency. (See page 6 for full cleaning instructions.)
GF-350 Shown
HOW YOUR
SLANT/FIN
WARM MIST
HUMIDIFIER WORKS
The model GF-300 and GF-350 humidifier uses a two-step approach to eliminate potentially harmful microorganisms from the water before they are spread with the mist into the air. The first step uses a UV germicidal bulb, located inside the base of the humidifier, that shines on the water through a special glass tube as it passes from the cold water reservoirs to the hot water reservoir. The second step is the boiling action that takes place in the hot water reservoir just before the mist is distributed to the air in the room. These two methods limit the likelihood of harmful microorganisms getting into the atmosphere and being breathed by you, your family and pets.

CONTROL PANEL
POWER SWITCH —
LO AND HI POSITIONS
When the switch is turned to the “LO” or “HI” setting and the unit is plugged in, the power is on. With the unit running in the LO setting, it will be producing vapor at a lower rate than when running in the HI setting.

GF-350 Shown

OFF POSITION – This cuts power to unit and should be used (in addition to unplugging unit) before moving, performing maintenance, etc.
REPLACE UV BULB If the “REPLACE UV BULB” signal light is illuminated during normal use, the 4 bulb must be replaced with the same special 3.5W bulb. See the enclosed order

form. The UV germicidal bulb will operate a 2,000 hours (typically 1 to 2 years of norma may operate longer than 2,000 hours but a humidifier operating at maximum efficiency micidal bulb be replaced after 2,000 hours
REFILL/CLEAN INDICATOR – When il ing. See the section “Filling the Water Tank after full tank is placed on base, reposition only one water tank.) Each time you fill tan and cold water reservoirs, clean them acco if minerals or film are present.
RELATIVE HUMIDITY CONTROL – Th erate humidity is desired, the control shoul “LO”; and if higher humidity is desired, cloc
NOTE: When you unpack your humidifier, y on some surfaces. This is normal as every Carefully unpack humidifier and remove all
OPERATING INSTRUCTIONS 1. Fill the water tanks according to the ins
humidifier base. 2. Plug the power cord firmly and complet 3. Turn the switch to either the LO or HI p
humidifier to take a few minutes to war 4. When the water tanks are empty, (after
time), the “REFILL/CLEAN WHEN LIT” heating. Refer to the “FILLING THE WA 5. Whenever the water falls below the leve heating element will shut off and stop h cator will light. 6. The unit will operate as long as there is operate with either one or both tanks.
FILLING THE WATER TANKS 1. Before filling the water tanks, turn the P
and unplug unit. Refer to CLEANING IN 2. Remove water tanks from base, turn ea
tank cap by turning counterclockwise. Replace the tank cap by turning clockw 3. Carefully pick up tank, since it will be h 4. Place water tanks on base. Make sure the humidifier will not work correctly.
USING THE MEDICATION CUP In order to add a medicated vapor to the “m 1. Turn the POWER switch to the “OFF” po
to cool. 2. Carefully add liquid medication to medic
than half full.

3. Carefully place medicine cup on top of steam diffuser 4. Turn the POWER switch to either the LO or HI position. 5. After use, remove the cup from the unit and clean any residue from the cup
with warm water.
WARNING: DO NOT use any liquid medication other than those specifically recommended for use with a steam vaporizer or warm mist humidifier. DO NOT pour medication directly into the steam diffuser openings nor add it to the water in the tank or tray.
MINERAL ABSORPTION PAD INSTRUCTIONS Warm mist humidifiers do not spread fine mineral dust into the air that you breathe nor on your furniture, the way that other type humidifiers do. The mineral dust remains trapped in the humidifier hot water reservoir. Use of mineral absorption pads will play a major role in capturing and removing minerals from hot water reservoir, and preventing a stubborn mineral buildup.
1. Before starting humidifier, place mineral absorption pad in the hot water reservoir. After the humidifier has been operating, the water will become HOT, and CAUTION should be exercised when handling mineral absorption pad. It is best to allow humidifier water to cool down, and to use tongs or long tweezers when handling pad.
2. The useful life of the mineral absorption pad will vary, depending on the mineral content of the water used. In areas of moderate mineral content water supply, the mineral absorption pad should be changed after approximately (3) weeks of continuous use. If the water is “Hard Water”, the pad should be changed more frequently. The best way to tell when the pad should be changed is to examine it AFTER the water has cooled down, to see if it is still soft and pliable. When the pad is near the end of its life, it becomes stiff and hard and should be replaced with a new pad. Another sign to change pad is when scale begins to buildup on interior of hot water reservoir.
CLEANING AND MAINTENANCE Water contains minerals and other particles. During operation most of these minerals will remain in the water reservoir. Gradual buildup of deposits will coat the hot water reservoir and reduce its efficiency. The importance of routine cleaning and care cannot be over- emphasized. Hard water contains more minerals and other particles.
CLEANING INSTRUCTIONS Failure to perform the necessary cleaning steps will damage unit. 1. Before cleaning, set CONTROLS to “OFF” position and unplug unit. 2. Remove water tanks from humidifier base, and drain water from tanks. 3. Allow at least 15 minutes after shutting unit “OFF” before moving base.
6

Rotate steam diffuser counterclockwi tabs in base, and lift up. Rotate steam with tabs in base and lift out. Remove reservoir using tweezers or tongs to the cleaning procedure is completed, drain water from humidifier base, gra draining water into the sink. BE CAR WATER FALL INTO CONTROLS OR
any manner other than indicated. WA running faucet. Turn the base upside by turning it counterclockwise. Clean mulated inside the fitting from which replace this cap tightly by hand. Pour water reservoir and check for leaks fr 4. Pour about 1 cup of white vinegar int for only 20 to 30 minutes. 5. Hold the base of the humidifier over t the vinegar. Fill the cold and hot wat remove all traces of the vinegar. Rem water reservoir and from the two me two metal wires) using a small brush buildup is due to water hardness. Th maintenance will be needed. Empty its side. If minerals remain in the met stainless steel blade in the steam do cup and used to scrape off the miner blade on any plastic parts. DO NOT ALLOW WATER TO ENTER BASE OR ANY OTHER OPENINGS, 6. Disinfect the water tanks using a solu chlorine bleach in 1 gallon of water. swishing every few minutes to wet all rinse thoroughly until all of the bleach fresh, cool water and replace them o 7. NEVER use any metal or hard object cause scratching of the plastic parts. part of the hot water reservoir. A me part only. Stainless steel metal scrap less steel metal boiler cup only. NEV cleaner, furniture polish, paint thinner any part of the humidifier. 8. Each day the reservoirs and tanks sh with fresh tap water. 9. To clean exterior surfaces, use a solu wrung-out damp cloth. Rinse and wri surfaces again. Finally, wipe with a d
before plugging the electrical cord int

10. After base is totally cleaned and dried, replace mineral absorption pad. Place steam dome on base by aligning its slots with tabs in base. (You may have to reposition steam dome to other set of tabs, because it will only fit one way.) Rotate steam dome clockwise until it locks. You may want to place scraper in slot in top of steam dome to store scraper when not in use. Place steam diffuser on base so that the slots in steam diffuser line up with tabs on the base. Rotate steam diffuser clockwise until it locks in place.
11. Plug in the unit and resume normal use.
CHANGING THE UV GERMICIDAL BULB
1. If the “REPLACE UV BULB” indicator illuminates during normal use, it is time to change the UV germicidal bulb, which is a special 3.5W bulb.
2. Turn the POWER switch to the “OFF” position, unplug it and allow it to cool.
3. Remove the water tanks from the base of the humidifier. Remove steam diffuser and steam dome by rotating them counterclockwise and lift up.
4. Place the base of the humidifier over the sink and tilt the unit to remove any remaining water.
5. Carefully turn the base of the humidifier over and place it upside down on a flat level surface. You will see a door at front of unit that is closed with two Phillips head screws.
6. Using a Phillips head screwdriver, carefully turn the screws counterclockwise until the screws separate from the door.
7. Open the door, by pulling forward. The UV germicidal light bulb will be visible. Pull the door out the minimum amount to have access to unscrew bulb from socket.
8. Take a replacement 3.5W UV germicidal bulb that you purchased from Slant/Fin Corporation or another supplier and change the bulb. To prolong the life of the bulb, limit your direct contact with the glass of the bulb by using a cloth or tissue to screw it into place.
9. When the new bulb is in place, close the door and replace the screws by using your Phillips head screwdriver and rotating them clockwise until they are just tight. DO NOT OVER TIGHTEN.
10. Turn the unit upright, place the water tanks on top of the base of the humidifier, plug the unit in, and turn the POWER switch to either the LO or HI position. The “REPLACE UV BULB” indicator should no longer be lit.
IMPORTANT NOTE: Even though you will not receive maximum germicidal effects, you can still use your GF-300 and GF-350 humidifier until the replacement bulb arrives.
8

STORAGE TIPS If you do not plan to use your humidifier during the summer months, it is importa help prevent problems from developing 1. Clean your humidifier as instructed i
Maintenance”. 2. Make sure all water is emptied from
reservoirs. 3. Dry your unit thoroughly. 4. Leave the tank caps off to expose th 5. Pack your humidifier in its original ca
SERVICE DO NOT attempt to repair this humidifie the warranty, contact Slant/Fin by teleph Number. Have other repairs professiona
GLOW It is normal to see the humidifier glow w glow results from the internal illuminatio ultraviolet light, even at this harmless lev into the room.
TROUBLESHOOTING

TROUBLE Unit does not mist
Water leaks from unit Moist air output low Refill/Clean indicator light on

POSSIBLE CAUS
Unit is not plugged Power failure Water tanks empty Power switch not tu Unit not reset after Water tank not prop located on base uni Humidity level set is using distilled or tre which does not con ions
Drain cap, drain cap tank cap or tank cap gasket is missing or positioned
Mineral buildup in h r eser vo i r
Water level is below level probes Water level probes are covered with film Mineral buildup in h r eser vo i r

LIMITED WARRANTY

IMPORTANT NOTICE PLEASE CLEAN THIS GERM-FREE HUMIDIFIER AT LEAST ONCE A WEEK BY FOLLOWING THE CLEANING INSTRUCTIONS IN THE OWNER’S MANUAL. FAILURE TO REGULARLY CLEAN THIS GERM-FREE HUMIDIFIER WILL RESULT IN A BUILDUP OF MINERAL DEPOSITS WHICH WILL CAUSE THE UNIT TO CEASE TO OPERATE. IF THE UNIT FAILS TO FUNCTION BECAUSE IT HAS NOT BEEN CLEANED, THIS WILL VOID THE WARRANTY.
To the original purchaser or gift recipient of this humidifier.
1. If your Slant/Fin humidifier fails in normal use because of a manufacturing defect within 90 days from the date of original purchase, Slant/Fin will repair the humidifier at no charge for parts, labor or shipment back to you (see instructions for returning unit below).
2. After the first 90 days, if a component part fails because of a manufacturing defect, Slant/Fin will repair or replace that component part up to 3 years from purchase date. There will be no charge for the component part or shipment back to you, but Slant/Fin reserves the right to charge for installation labor.
3. This warranty does not cover any product which in Slant/Fin’s judgment has been (1) damaged as a result of accident, misuse or abuse (2) used for a purpose for which it was not designed, or (3) repaired or altered in any way that adversely affected its performance or reliability. This warranty does not cover scratches and wear of surfaces.
4. UV bulb replacement is a normal maintenance procedure and is therefore not covered under this warranty unless the bulb is found to be defective.
5. For repairs, return humidifier to address shown below with dated sales receipt. The cost of shipment to Slant/Fin must be paid by the consumer. Return to: Consumer Service Dept., Slant/Fin Corporation, 40 Garvies Point Road, Glen Cove, NY 11542. In Canada: Slant/Fin LTD/LTEE, 6450 Northam Drive, Mississauga, Ontario L4V 1H9.
6. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
7. Slant/Fin makes no express warranties other than the warranties contained herein. Slant/Fin’s sole obligation in the event of a breach of any implied warranty (including, but not limited to, implied warranties of merchantability and fitness for a particular purpose) is limited to repair or replacement, and all such warranties are limited in duration to the time periods after the date of original purchase as stated above. The warranty does not cover claims for incidental or consequential damages resulting from a breach of any express or implied warranty or any other reason including damages due to accident, abuse, lack of responsible care, the affixing of any unauthorized attachment, loss of parts, or use at a voltage other than specified.
CUSTOMER SERVICE #: 1-800-775-4552
10

®
Humidificateur électrique po bruines tièdes Germ-FreeMD
GF-350
· Instructions sur le fonct et le nettoyage
· Garantie limitée LIRE ET CONSERVER

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Honeywell User Manuals

Related Manuals