RADDY WF-80C Weather Station
INSTRUCTION MANUAL
MODEL: WF-80C
Features:
► DCF Radio control time function
► Perpetual Calendar Up to Year 2099
► Day of week in 15 languages user selectable: English, German, French,
Spanish, Italian, Dutch, Danish, Portuguese, Norwegian, Swedish, Polish,
Finnish, Czech, Hungarian, and Russian
► Time in optional 1:?/24 hour format.
► Two daily alarms
► Automatic snooze function (OFF or 5~6omin)
► The moon phase display
► Temperature:
– Indoor temperature measurement ranges: 0″C (32″F) ~ 50″C {122″F)
-Remote temperature measurement ranges: -40″C (-44″F) ~ 70″C {158″F)
– Temperature alternatively in •c or “F.
-Remote thermometer and frost alert
► Humidity: Indoor & Remote measurable range: 20%RH ~ 95%RH
► Minimum/maximum display for air humidity and temperature
► Display of comfort and mold risk
► Wireless Remote Sensor:
– Wall Mount or Table Stand
– One Wireless Thermo Sensor Included
– 433.92MHz RF transmitting frequency
– 60 meter transmission range in an open area
– Up to 3 wireless outdoor sensors can be connected.
► Atmospheric pressure:
– Atmospheric pressure measurement ranges: 600 hPa/mb to 1100 hPa/mb
17.72 inHg to 32.50 in Hg
– Pressure alternatively in hPa/mb or inHg
► The weather forecasting function
► Power Supply:
Weather Station:
Battery: 1 x CR2032 (no dispaly)
Equipment power input: DC 5V 600MA (dedicated power adapter)
Wireless Remote Sensor:
Battery:2 x LR03 AAA
F.Y.I.:
The wireless remote sensor can work at -30″C to + 70″C. Please choose the
right battery according to the limit temperature of the wireless sensor:
Alkaline zinc manganese battery can work at -20″C to +60″C
Polymer lithium ion rechargeable battery can work at -40″C to +70″C.
Weather Station Appearance
Part A-Positive LCD
Al: Weather Forecasting
A3: Mold Risk of Wireless Remote Channel 1
AS: Comfort Index of Wireless Remote Channel 1
A7: Mold Risk of Wireless Remote Channel 2
A9: Comfort Index of Wireless Remote Channel 2
All:Time
A13: Mold Risk of Wireless Remote Channel 3
AlS: Comfort Index of Wireless Remote Channel 3
A17: Temperature of Indoor
A2: Temperature of Wireless Remote Channel 1
A4: Humidity of Wireless Remote Channel 1
A6: Temperature of Wireless Remote Channel 2
AS: Humidity of Wireless Remote Channel 2
AlO: Month and date
A12: Temperature of Wireless Remote Channel 3
A14: Humidity of Wireless Remote Channel 3
A16: Atmospheric pressure
A18: Mold Risk of Indoor
A19: Humidity of Indoor
A21: Moon phase
A20: Comfort Index of Indoor
A22: Week Day
Part B – Back button and power
Bl: ··t ·tsEr button
82: “ALARM” button
83: •ALERT” button
84: “SNOOZE/LIGHT” button
BS: “CHANNEL” button
86: “UP- button
87: “DOWN” button and “MEM” button
88: Hanging hole
89: Battery compartment
810: Support frame
811: Power supply socket
Part C-Wlreless RemOII! Sensor:
Cl: LCD display-Temperature
C2: LCD display- Humidity
C3: Transmit signal LED
C4: -CfF• button
CS: “TIC” button
C6: “CHANNEL 1 or 2 or 3” switch
CT: Battery compartment
Initial operation:
► First, open the battery slots of the three remote wireless sensors
respectively, first set the number of channels, set them in channel 1, channel
2 and channel 3 respectively, and then install the 2 x “AAA”
1.5V battery according to the battery polarity direction.
► When the wireless sensor is loaded into the battery, all the icon on the LCD
display will briefly light up for 3 seconds, and detect the temperature and
humidity of the sensor, At the same time, LED lights flicker once, the
wireless sensors automatically transmit wireless signals.
► According to the appearance of the Weather Station, the power adapter is
inserted from the B11 position, and the power supply of the power adapter is
also noted.
► Open Weather Station battery compartment cover, open Weather Station battery
compartment cover, insert CR2032 batteries observing polarity [ “+” and “-”
marks] ► After the weather station is connected to the power supply according
to the above two steps, all the icons on the LCD display will light up for 3
seconds, you will hear the buzzer, and check the indoor temperature, humidity
and pressure.
► The weather station will now start connecting to the outdoor remote sensor.
This operation takes about 3 minutes, and the receiving RF antenna symbol
displays and flashes above the three channel labels corresponding to the
weather station.
► The signal from 3 sensors will be automatically received within 3 minutes.
After receiving, the temperature and humidity of the remote sensors in the 3
channel bars will be displayed.
Manual time setting:
► Press and hold down the /SET” button more than 2 seconds to enter the time
and general settings, first set the temperature of the unit, now use “UP” and
“DOWN” buttons to set the unit of temperature in “°C” or “”F”.
► Press /SET” to confirm your setting, switch to radio controlled clock(RCC)
function setting, Now use “UP” and “DOWN” buttons set the RCC receive function
to activate(ON) or close(OFF)
► Press /SET” to confirm your setting, switch to daylight saving time (DST)
function setting, Now use “UP” and “DOWN” buttons set the DST function to
activate(ON) or close(OFF)
► Press /SET’ to confirm your setting, switch to the 1:1/24 hour mode display
setting. Now use “UP” and “DOWN” buttons to set the time displayed in 12-hour
or 24-hour format
► Press ” /SET” to confirm your setting, switch to time zone setting, Now use
“UP” and “DOWN” buttons set a correct time zone (-2 to +2).
► Press /SET” to confirm your setting, switch to the hour setting. Now use
“UP” and “DOWN” buttons to set the correct hour.
► Press /SET” to confirm your setting, switch to the minute setting. Now
use”UP” and “DOWN” buttons to set the correct minute.
► Press /SET” button to confirm your setting, switch to the Month and Date
display setting. Now use “UP” and “DOWN” buttons to set the date display on
Month/Date or Date/Month.
► Press /sET” button to confirm your setting, switch to the year setting. Now
use “UP” and “DOWN” buttons to set the correct year.
► Press /SET” button to confirm your setting, switch to the month setting. Now
use “UP” and “DOWN” buttons to set the correct month.
► Press “ /SET” button to confirm your setting, switch to the date setting.
Now use “UP” and “DOWNn buttons to set the correct date.
► Press /sET” button to confirm your setting, switch to the language selection
for the week and month displays setting. Now use “UP” and “DOWN” buttons to
select a language.
Note: There are 15 languages of Weekday: English, German, French, Italian, Spanish, Portuguese, Dutch, Danish, Norwegian, Swedish, Polish, Finnish, Czech, Hungarian, and Russian
Week language display
► Press /SET” to confirm your setting, switch to pressure unit setting. Now
use the •uP” and HDOWNH button to set the pressure of the unit, the unit oft
pressure can be set to “hPa• or Hin Hg”
► Press /SET” button to confirm your setting, switch to barometric pressure
calibration mode. Now use “UP” and “DOWN .. buttons to set the atmospheric
pressure value.
► Press /SET’ button to confirm your setting, switch to setting the initial
weather. Now use .. UP” and •DowNHbuttons to to select the current weather
► Press” /SET” to confirm your setting and to end the setting procedures,
enter the clock mode
► During the time setting process, Press the NOOZE/UGHT” button to exit the
setting mode directly.
F.Y.I.:
► After 20 seconds without pressing any button, the clock switches
automatically from Set Mode to Normal Time Mode.
► In the set time, the number of minutes of the change, automatically from the
zero second forward
► In the set time, you can press hold the •up• and “DOWN” button to quickly
change the setting of the value
► When the weather station is in the same area as Germany, the time zone is
set to 00, one hour slower than German time, the time zone is set to -01, one
hour faster than German time, the time zone is set to 01, 2 hours faster than
German time, time zone Set to 02,
► Exceeding the German signal tower diameter of 1500KM or more, the signal
received by the radio clock signal is very poor. It is recommended to set the
RCC to OFF.
► If the daylight saving time system is not implemented in this area, please
select ON or OFF according to whether the city in your area adopts daylight
saving time, and the time of sunrise and sunset will also be determined
according to daylight saving time
Setting the dally alarms:
► Press and hold down”ALARM button more than 2 seconds to enter the alarm
setting mode, first enter the alarm 1 hour setting. Use the “UP” and “DOWN ..
buttons to set the required hour.
► Press •ALARM” button to confirm your setting, switch to the alarm 1 Minute
setting. Use the “UP” and HDOWN” buttons to set the required minute.
► Press “AlARM” button to confirm your setting, switch to the alarm 1 repeat
setting. Use the “UP” and “DOWN” buttons to set the alarm repeat in “M-F” or
“5-5” or “M-5”.
► Press “AlARM ~ – button to confirm your setting, switch to the alarm 1
snooze time setting. Use the “UP” and “DOWN” buttons to set the minute of
snooze you need.
► Press “AlARM” button to confirm your setting, switch to the alarm 2 hour
setting. Use the “UP” and “DOWN” buttons to set the required hour.
► Press “ALARM” button to confirm your setting, switch to the alarm 2 minute
setting. Use the “UP” and “DOWN” buttons to set the required minute.
► Press “‘ALARM” button to confirm your setting, switch to the alarm 2 repeat
setting. Use the “UP” and “DOWN” buttons to set the alarm repeat in “M-F” or
“5-5” or “M-F” and “S-S”.
► Press “ALARM” button to confirm your setting, switch to the alarm 2 snooze
time setting. Use the “UP” and “DOWN” buttons to set the minute of snooze you
need.
► Press “ALARM” button to confirm your setting and to end the setting
procedure.
► During the alarm setting process, Press the “SNOOZE/LIGHr button to exit the
setting mode directly.
F.Y.I.:
► After 20 seconds without pressing any button the clock switches
automatically from setting mode to Normal clock mode.
► When the alarm repeat is set to M-F, the alarm function will be activated
from Monday to Friday, and will be disabled on Saturday and Sunday, “M-F”
appears below the alarm symbol. When the alarm repeat is set to S-S, the alarm
function will be activated on Saturday and Sunday, and will be disabled from
Monday to Friday, and a •s-s• appears below the alarm symbol. When the alarm
repeat is set to display M-S at the same time, the alarm function will be
activated for a week, “M-F” and “S-5” appears below the alarm symbol.
► The snooze time setting range: S – 60MIN, OFF, when set to OFF, means no
snooze function. Snooze time unit is minutes.
The alarm for opening and closing
► Press “ALARM” button can switch the display ALARM1 time or ALARM2 time, in
the alarml or alarm2 display mode, press the “UP” button to turn the alarm on
or off.
► The alarm 1 or alarm 2 turn on, the .(i) or Cil”icon is displayed, the alarm
1 or alarm 2 function is open, The repeat of alarm icon at the same time is
also displayed.
► The alarm 1 or alarm 2 turn off, the”(i)” or “(i)”icon disappears, the alarm
1 or alarm 2 function is close.
► During alarm viewing mode,, Press the “SNOOZE/LIGHT” button to exit the
setting mode directly.
F.Y.I.:
► The alarm will sound for 2 minutes if you do not deactivate it by pressing
any button. In this case the alarm will be repeated automatically after 24
hours.
► Rising alarm sound (crescendo, duration: 2 minutes) changes the volume 4
times whllst the alarm signal is heard.
► Press any button except the •sNOOZE/UGHl” buttcn to stop the al1rm 5igna I. It is not nece551lry to reactiwte the alarm. It switches itself automatically t0 the alarm time which has already been set.
Snooze function:
► When the time Is up to the alarm, press the ‘”SNOOZE/UGHl” button, the alarm
slgnal stops, and enter the SNOOZE mode. After the snooze time Is counted, the
alarm will ring again.
► In snooze mode, press any buttons except the “SNOOZE/LIGHT’ button or press
the ‘”SNOOZE/UGKI” button and hold for mon! than 2 seconds to exit the snooze
mode.
F.Y.I.:
When the snooze function Is set to OFF, when the time Is up to the alarm, press the -SNOOZE/LIGHT” button does not have this snooze function.
Lunar phases:
► The Moon Icon Indicator of the Weather Station wlll also dlsplay 12 different Moon phase phases aa:ordlng ID the set calendar.
Temperature & Humidity detection:
► Indoor temperature measurlna range: -9.9″C (+14″F)-+SO”C (+122″F), lLL
·crF)will dlsplayed If value lower than -9.9″C (+14″F), HH.H “q”F) will
displayed If value higher than +SO”C (+122″F).
► Outdoor temperature measuring range: 40″C (-40″F) – +70″C (+158″F), LLL
•q•F) wlll displayed If value lower than -40″C (-40″F), HH.H “C(“F) wlll
displayed If value h lg her than + 70″C (+ 158″F).
► Indoor and outdoor humidity measuring range: 20’J6RH – 95%RH, 19KRH will
displayed If value lower than 209’RH, “”RH will dlsplayed If wlue higher than
9S9’RH.
Wireless sensor transmission:
► When the weather station sua:essfully receives the signal from the wireless
sensor, the outdoor temperature and humidity wlll be displayed In the columns
af channels 1, 2 and 3 af the weather station.
► The Weather station can connect up to 3 channel wireless sensor
registration, the use of multiple wireless sensor, the wlreless sensor channel
cannot choose the same channel at the same time (A total af 1, 2, 3 channels
can be set. three sensors need to set different channels)
► If any channel af the weather station falls to receive the transmission from
the outdoor sensor “__” displayed on the LCD), press the -CHANNEL ff button to
seled the corresponding channel number.
After seledlng, the corresponding channel number will flash and display, at
this time, press and hold the CHANNEL# button for 3 se«inds to r«eive and
transmit manually. The RF receiving antenna symbol “‘~” flashes, and the
weather station will receive the wireless signal from the outdoor sensor
again.
Dlsplayling temperature/humidity and temperature/humidity trend
► The a.immt indoor temperature/humidity/barometric pressure and the
temperature/humidity trend (Indoors) are shown tn the LCD display.
► After successfully connecting with the remote sensor, the weather station
can display the remote temperature/humidity and the temperature/humidity trend
(remote)
► You may see the following displays:
: The temperature/humidity ts rising.
: The temperature/humidity Is remaining constant.
: The temperature/humidity Is falling.
Maximum/Minimum Temperature/Relative Humidity
► To toggle indoor/outdoor maximum, minimum temperature and humidity data,
press the •DOWN• button:
Once to show the maximum temperature and humidity values.
Twice to sow the minimum temperature and humidity values
Three times to return to the current temperature and humidity levels
► To reset the maximum and minimum temperature and humid~ pn!SS and hold down
the “DOWN” button ;ibout 2 seconds. This will reset all minimum and mu:imum
data recorded to the current dlsplayed va I ues.
F.Y.I.:
► If thr temperature reading is below ranges, the LU will br displayed. If the
temperature reading is abavt! ranges, the HH.H will be displayed.
► If thr humidity reading is below ranges, tflr J97’RH will be dispkzyrd. If
the humidity reading is above ranges, the HUH will be dlsp/ayed.
Comfort and mildew risk instructions
► T here are 4 dlsplay modes fer the comfort level, as follows:
► The moldy risk display reads the humidity to determine moldy risk level. The weather station will display one of 4 lndlcators: HI (high) ME (medium) ID (low) and no risk (no arrow displayed).
Temperature and Humidity alerts setting
► In the nonnal display, press the ‘”Al.ERi”‘ button to switch to the
temperature and humidity alert item viewing mode, and then press the “ALERT”
button to switch to view the next item, in order: temperature upper llmlt
alarm, temperature lower llmlt alarm, humidity upper llmlt alarm, humidity
lower llmlt alarm, frost alarm (INDOOR has no frost point alarm Item), and can
switch cycllcally
► In this alert Item viewing mode, press the “atANNELH button tD switch tD a
different channel, In the order of items: IN, CH1, CH2, CH3, and can switch
cyclically
► In this alert Item viewing mode, the alert function of each Item can be
turned on or off by pressing the •* /SET” button when the respective Item Is
displayed, and the corresponding alarm symbol •HIA• or •LOA• or•! • is
displayed when it is turned on.
► During alert viewing mode, Press the “SNOOZE/U6Kr’ button to exit the
setting mode directly.
► Press and hold down the HALERT” button for more than 2 seconds to enter the
temperature and humidity alert setting, the first Is the upper llmlt alert
setting of the temperature. Use the “UP” and “DOWN” buttons tD set the upper
llmlt alert value
► Press the “ALERr button to confirm and switch to the next item, set the
lower limit of the temperature alert, Use the “UP” and “DOWN” buttons to set
the lower limit alert value
► Press the •ALERT” button to confirm and switch to the next Item, set the
upper llmlt of the humidity alert, Use the -UP” and “DOWN” buttons to setthe
upper llmlt alert value
► Press the “ALERr button to confirm and switch to the next item, set the
lower limit of the humidity alert, Use the -UP” and “DOWN” buttons to setthe
lower limit alert value
► Press “ALERT’ button to confirm your settings and end the setup process.
► When setting the upper and lower llmlt alerts for temperature and humidity,
press the “CHANNEL” button to switch the alert settings for setting the upper
and lower temperature and humidity limits of different channels.
► During the alerts setting process, Press the ‘”SNOOZE/UGHr button to exit
the setting mode dlrectly.
F.Y.I.:
► After 20 seconds without pressing any button, the dock switches
automatically from Set Mode to Normal Time Mode.
Temperature and humidity upper and lower llmlt and frost warning
► When the upper limit or lower limit alarm of the wrresponding channel is
turned on, and the actual value of its temperature or humidity exceeds the set
upper limit or lower limit limit. the corresponding upper llmlt symbol •HIA”
or lower llmlt symbol •LOA” and the corresponding dlsplay data wlll flash. At.
the same time, the product emits an alarm 50und.
► When the frost alarm of the channel corresponding to the remote wlreless Is
turned on, and Its
temperature Is In the range af-1 •c {+30°F) tD + 3°C (+ 37°F}, the frost alarm
Is triggered, the frost symbol is displayed on the corresponding channel and
flashes, and the product emits an ala nm sound at the same time.
► In this alert mode, press any button to stop the alarm sound, and the
warning Is stlll displayed.
► If the INDOORM column Is dlsplay the battery Icon , you need to replace the
weather station”s battery as soon as possible,
► If the OUTDOORN column is to display the battery icon , vou need to replace
the wireless sensor battery of vour channel as soon as possible based on the
channel display.
The weather forecast:
► The weather station ca I cu I ates a weather forecast for about the next 12 hours based on the barometrtc pressure trend. Of course this forecast can’t compare tD that of professional weather services supported by sat2llites and hil;h performance computers, It provides only an approximate indication of the current weather dewlopment in a small local area. Please take the weather forecast from your local weather forecastins service into at:Cl)unt as well as the fo~ from vour weather station. If there are discrepancies between the infurmation from your device and fJtJm the local weather furecastins service, please take the advice of the latter as authoritative.
F.Y.L:
► The Snowy Icon will only appear If the outdoor temperature ls below -4’C
(+25’F) and the forecast would be rainy or stonny, By default, according to
the temperature of CH1, when there is no signal in CHl, it is calculated
at:Cl)rdins to the temperature of CH2. When there is no signal in CHl .ind
CH2, it is calculated according to the temperature of CH3.
► After the weirther stiltion needs 7-10 d.ty5 of c1ir pressure calibration,
the we.rther forecast will tend to be stable with an aiccurac:v rate
of:70’6–75’6.
► The forecast can be given for a radius of up to 12-20km.
► The weather station can display the barometric pressure trend.
Reception of the Radio slgnal:
► The clock automatically starts the DCF slgnal search after 7 minutes of any
restart or changing of new fresh batteries. The radio mast Icon starts to
flash.
► At 1:00 /2:00 / 3:00, the dock automatically carries out the synchronization
procedure with the oa: signal to correct any deviations to the exact time. If
this synchronization attempt is unsuccessful (the radio mast icon disappears
from the display), the system will automatically attempt another
synchronization at the next full one hour. This procedure is repeated
automatically up to total 5 times.
► To start manual DO’ signal reception, press and hold down the RUP” button
for two seconds. If no signals received within 7 minutes, then the DCF signal
search stops (the radio mast icon disappears) and start again at the next full
one hour.
► ourtng OCF radio slgna I reception , to stop search lng radio slgnal, press
and hold down thenu P” button for two seconds.
F.Y.I.:
► A flashing radio mast icon indicates that the DCF signal reception has
started
► A continuously displayed radio mast icon indicates that the DCF signal was
received successfully
► The symbol “DST” indicating the time of receipt for daylight saving time.
► We recommend a minimum distance of 2.5 meters to all sources of
interference, such as televisions or computer monitors
► Radio reception is weaker in rooms with concrete walls (e.g.: in cellars)
and in offices. In such extreme circumstances, place the system close to the
window.
► During the DCF radio reception mode, only the •up• button function, other
button operations can only turn on the backlight. If you want to perform other
operation functions. press the “UP” button to exit the DCF radio reception
mode.
► Note that when you enter the radio control time receiving mode, the
backllght will automatically turn off. This is a normal phenomenon. After the
radio control time receiving reception, the backlight will be automatically
lit.
Background lighting
► If the product is powered by batteries, press the “SNOOZE/LIGHT” button.
Backlight lit 15 seconds.
► When the power supply of the product is inserted into the power supply
adapter, the battery will automatically disconnect the power supply, and the
backlight will always be bright. Press the • /SET” button to adjust the
brightness of the backlight, you can adjust the 5 state: 4 different
brightness backlight and close the backlight. When the backlight brightness is
not at the maximum brightness, press the “SNOOZE/LIGHT” button. Backlight
turns to highest brightness of 15 seconds.
► The weather station can also set the backlight to automatically dim at
night. Press and hold the “SNOOZE/LIGHT” button for more than 2 seconds to
enter the night mode setting. First, turn the night function on or off. Now
use •up• and “DOWN• buttons set the night function to activate (ON) or close
(OFF).
► Press • /SET” button to confirm your setting, switch to the brightness
setting of the backlight change after entering the night. Now use “UP” and
“DOWN• buttons set the brightness required for the backlight change after
entering the night
► Press a* /SET” button to confirm your setting, switch to the hour of enter
night mode setting. Now use “UP” and “DOWN• buttons set the required hour
► Press • ·~-/SET” button to confirm your setting, switch to the minute t of
enter night mode setting.
Now use 8 UP” and 8 D0WN• buttons set the required minute
► Press /SET” button to confirm your setting, switch to the hour of exit night
mode setting. Now use “UP” and “DOWN• buttons set the required hour
► Press /SET” button to confirm your setting, switch to the minute of exit
night mode setting. Now use “UP” and “DOWN• buttons set the required minute
► Press /SET” button to confirm your setting and to end the setting procedure.
► During the night mode setting process, Press the “SNOOZE/LIGHT” button to
exit the setting mode directly.
► When the night mode Is on, the Icon will be displayed. When the time reaches
the time to enter the night mode, the backlight will automatically switch to
the set night mode brightness, and when the time reaches the time to exit the
night mode, the backlight will return to the original brightness
► In night mode, the backlight can be switched to the highest brightness for 15 seconds by pressing the “SNOOZE/LIGHr’ button
F.Y.I.:
► During the reception of the time radio wave signal, the backlight will be automatically closed to prevent the interference of the radio wave.
Specification
► INDOOR’s temperature detection range: -20″C ~ +60″C & -4″F ~ +140″F, display
resolution: 0.1 •c & “F
► The detection temperature of INDOOR is lower than -20″C & -4″F, displayed as
LL.L”C & “F, higher than +60″C & +140″F, displayed as HH.H”C & “F.
► INDOOR humidity display range: 20%RH ~ 95%RH, display resolution: 1%RH
► If the detected humidity of INDOOR is lower than 20%RH, it will be displayed
at 19%RH, and if it is higher than 95%RH, it will also be displayed at 96%RH.
►The temperature and humidity detection cycle of INDOOR is 60 seconds.
►Temperature display range of OUTDOOR: -40″C ~ +70″C & -40″F ~ +158″F, display
resolution: 0.1 •c & “F
►The detection temperature of OUTDOOR is lower than -40″C & -40″F, displayed
as LL.L”C & “F, higher than +70″C & +158″F, displayed as HH.H”C & “F
► Humidity display range of OUTDOOR: 1%RH ~ 99%RH, display resolution: 1%RH —
Humidity display range 20 ~ 95%
► When the detected humidity of OUTDOOR is lower than 1%RH, it will be
displayed at 1%RH, and if it is higher than 99%RH, it will also be displayed
at 100%RH.
► Air pressure detection range: 600 hPa/mb ~ 1100 hPa/mb & 17.72 inHg ~ 32.50
inHg & 450mmHg ~ 825mmHg, display resolution: 1 hPa/mb & 0.01 inHg & 0.lmmHg
Product Specifications
- Model: WF-80C
- Dimensions: 2 x 3 x 5 inches
- Weight: 7 lbs
- Power: 8 watts
- Capacity: 9 liters
- Material: Plastic
Product Usage Instructions
1. Setup
Place the product on a flat, stable surface near a power outlet.
2. Power On
Plug in the power cord and switch on the device using the power button.
3. Loading
Open the lid and carefully load your items into the designated compartment.
4. Settings Adjustment
Use the control panel to adjust settings such as temperature, time, or speed as needed.
5. Operation
Close the lid securely and start the operation by selecting the desired mode.
6. Maintenance
Regularly clean the product according to the maintenance instructions provided in the manual.
Frequently Asked Questions (FAQ)
Q: How do I clean the product?
A: To clean the product, unplug it first, then use a damp cloth to wipe the exterior. For interiors, follow the cleaning instructions in the manual.
Q: Can I use this product for wet items?
A: No, this product is designed for dry items only. Do not attempt to use it with wet or liquid items.