Raddy PT-3 Wi-Fi Pool Thermometer Instruction Manual
- July 27, 2024
- RADDY
Table of Contents
- Raddy PT-3 Wi-Fi Pool Thermometer
- Product Information
- Product Usage Instructions
- Technical Data and Features
- Feature Introduction
- Initial operation
- Download Tuya Smart App
- Outdoor sensor transmission
- Manual time setting
- Setting the daily alarms
- Snooze Function
- FAQ
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Raddy PT-3 Wi-Fi Pool Thermometer
Product Information
Specifications:
- Time format : 12/24 hour
- Automatic calibration of network time service
- Daily Alarm with snooze function
- Indoor and outdoor humidity measurable range: 20%RH to 95%RH
- Temperature measurement ranges
- Wireless Outdoor Sensor: 3 Channels selectable
- Data transmission frequency: 433 MHz
- Wireless range : max. 60 m (open area)
- Batteries : 2 x LR03, 1.5 V (size AAA, pool temperature sensor)
- Batteries : 4 x LR6, 1.5 V (size AA, temperature and humidity sensor)
Product Usage Instructions
Initial Operation:
Before closing the battery door, ensure gaskets are properly seated to avoid
water leakage and damage. Use a wrench to lock the lid securely and align the
key hole. Insert the key and turn 90 degrees to lock.
Pairing Mode:
- To pair the remote sensor, close the lid and add a tether. If pairing fails, press and hold the CH button for 2 seconds to re-enter pairing mode. After successful pairing, place the remote sensor in the swimming pool to detect water temperature.
- When using wrenches, ensure the arrow symbol faces upwards. Tighten the small wrench with the lower cover and match the big wrench tightly with the upper cover, especially aligning the arrow positions.
- Properly match the two wrenches at 90 degrees for easy opening. Twist the wrenches in the indicated direction to open the battery compartment covers of the wireless remote sensors.
Technical Data and Features
MAIN:
- Time in optional 12/24 hour format.
- Automatic calibration of network time service
- Daily Alarm with snooze function
- Indoor and outdoor humidity measurable range: 20%RH to 95%RH
- temperature measurement ranges::
- Indoor :-9.9°C to 50°C or(14.2°F to 122°F)
- utdoor :-40°C to 70°C or(-40°F to 158°F)
- Temperature alternatively in °C or °F.
- Maximum / Minimum indoor and outdoor (2 channel) temperature and humidity record and query
- Wireless remote monitoring of 2 channel wireless temperature and humidity sensor and 1 channel wireless pool temperature sensor
- Comfort level display of pool temperature
- Display the maximum, minimum and real-time temperature of swimming pool temperature on the same screen
- Connects directly to wifi network, connect to Tuya Smart System
- Power Supply:
- Battery : Built-in rechargeable lithium battery (1200mAh)
- Equipment power input : DC5V is greater than 500mA (Type-C interface)
Wireless Outdoor Sensor:
- 3 Channels selectable
- Data transmission frequency : 433 MHz
- Wireless range : max. 60 m (open area)
- Batteries : 2 x LR03, 1.5 V (size AAA, pool temperature sensor)
- Batteries : 4 x LR6, 1.5 V (size AA, temperature and humidity sensor)
Feature Introduction
Part A – Positive LCD
- A1: Time
- A2: Indoor temperature
- A3: Indoor humidity
- A4: Channel 1 temperature
- A5: Channel 1 humidity
- A6: Channel 2 temperature
- A7: Channel 2 humidity
- A8: Comfort level display of pool temperature
- A9: Channel 3 Pool Thermometer
- A10: Maximum value of pool thermometer for channel 3
- A11: Minimum value of pool thermometer for channel 3
Part B – Back Button and Power
- B1 : “SNOOZE/LIGHT” button
- B2 : “SET/MODE”
- B3 : “-” button
- B4 : “MEM” button
- B5 : “ALARM” button
- B6 : “+” button
- B7 : Power ON/OFF button
- B8 : Reset button
- B9 : Power supply socket –TYPE-C
- B10 : Hanging hole
- B11 : Support frame
Part C –Wireless Remote Sensor:
- C1 : LCD display – Temperature
- C2 : LCD display – Humidity
- C3 : Transmit signal LED
- C4 : “°C/°F” button
- C5 : “TX” button
- C6 : Battery compartment
Part D –Wireless Water Temperature Sensor:
- A : Channel switch
- B : Low battery indicator
- C : Temperature signal emission indicator
- D : Temperature value
- E : LED indicator for signal transmitting
- F : Transmitting antenna
- G : Unlocking key
- H : Channel selection switch
- I : °C/°F selection switch
- J : Waterproof rubber ring
Initial operation
-
This now, twist the unlocking key of the remote sensor 90 degrees and remove it, twist the main body of the sensor by removing the upper lid and lower lid with wrench(included) , choose the temperature unit and channel you need, open the battery cover, insert 2 x AA batteries【note of observing polarity “+” and “–“ marks】, as shown in below image.
-
The temperature unit °C/°F can be selected by turning the switch “I”, and the channel can be selected by turning the switch “H”
-
Before closing the battery door, make sure both gaskets are properly seated in their traces as shown in below image. Failure to properly seal the floating thermometer will result in water leakage and damage.
-
To close the lid, twist the upper lid and lower lid with wrench until it is firmly locked and the key hole is aligned. Insert the key and turn 90 degrees to lock the lid, as shown in below image.
-
After close the lid, a tether can be added into the key hole.
-
This pairing mode only takes 3 minutes, if the pairing fails after more than 3 minutes, you need to press and hold the “CH” button for 2 seconds to re-enter 3 minutes pairing mode.
-
After successful pairing, the remote sensor can be put into the swimming pool to detect its water temperature.
-
When using the wrenches, the side with the arrow symbol should face upwards.
-
The small wrench and the lower cover must be fixed in a tight direction.
-
The big wrench and the upper cover must match tightly, especially the arrow positioning.
-
Make sure that the two wrenches are properly matched to 90 degrees, so that it can be opened easily.
-
Grasp the small wrench with your left hand and the large wrench with your right hand, and twist the wrench with force in the direction indicated by the arrow on the wrench.
-
Open the battery compartment covers of two wireless remote temperature and humidity sensors, Insert 2 x AA batteries observing polarity [ “+” and “–” marks]
-
When the wireless sensor is loaded into the battery, all the icon on the LCD display will briefly light up for 3 seconds, and detect the temperature and humidity of the sensor, At the same time, LED lights flicker once, the wireless sensors automatically transmit wireless signals.
-
Preparation before starting the host:
Download Tuya Smart App
- According to the brand of the phone, search for Yuya through the IOS APP Store or Android’s Google play, find the APP with the icon below, and download the APP.
- After the APP download is complete, open the APP to register an account and complete the login
According to the illustration, insert the power adapter into the power input interface of B9, the display screen of the main unit will show all the graphics and a BEEP sound prompt will be issued. After 3 seconds, it will switch to the WIFI pairing mode and display “AP 01” .
Note : You can also press and hold the button for 3 seconds according to the prompt, and the product will automatically start. If the same product is started manually, it will also automatically enter AP mode, If it is not normal, the battery may be dead. Please connect the DC power supply to charge the battery
If the startup is not normal, please press the “RESET” button to reset.
- At this time, the APP will automatically prompt whether to join the device, click ADD.
- Then follow the APP prompts,
- step 2 : set the WIFI name and password,
- step 3: pairing process, click NEXT,
- step 4: click Done, switch to the main interface of step 5, indicating that the pairing is complete. Note : The paired WIFI hotspot must be 2.4GHz, this product only supports 2.4GHz wireless network
- If the main unit does not automatically enter the AP mode when it is powered on for the first time, it can be entered by pressing the “+” button for more than 3 seconds, and the display after entering is the same as the display automatically entering the AP mode
- When the pairing is completed, the main unit will automatically convert to the conventional display interface, and at the same time, it will automatically provide the time, and the time will be changed to the current time.
- The icon is displayed, which means the network time, and at the same time, it starts to search for the signal of the remote wireless sensor. The icon flashes, and the time is about 3 minutes. At this time, if the outdoor wireless sensor is running normally, the main unit will start to search for the signal of the remote wireless sensor in about 1-2 minutes. When a signal is received inside, the outdoor temperature will be shown on the main unit’s display.
- There are two types of WIFI connection methods for the main unit. When using an external power supply, WIFI will always establish a connection, and data will be uploaded to the cloud server from time to time. When powered by an internal lithium battery, WIFI uploads data every hour.
- When using internal battery power, pressing the “SET/MODE” button can manually turn on WIFI for 5 minutes. During this time, data can be uploaded from time to time. At the same time, the main unit can be set for units, backlight brightness, and other settings through the APP
Outdoor sensor transmission
- The main unit can connect up to 2 channel wireless temperature and humidity sensor and 1 channel wireless pool temperature sensor registration, Each sensor has been fixed with its corresponding channel, please use it according to the purpose of the sensor
- The main unit will automatically connect to the wireless sensor. If there is a channel that is not connected (the temperature and humidity values display -), first press the “-” button to select the corresponding channel (the channel icon flashes), and then press and hold the “-” button for more than 3 seconds to enter the registration mode. This time is kept for 3 minutes, and if there is a pairing signal from the wireless sensor within 3 minutes, it indicates that the automatic pairing is successful, The temperature or humidity data of the sensor will be displayed.
F.Y.I.:
- When there is no wireless sensor signal transmission on the channel, the temperature or humidity on the wireless sensor bar of the main unit are displayed – -,
- If the battery icon is displayed under the wireless sensor bar of the main unit, you need to replace the wireless sensor battery of your channel as soon as possible based on the channel display.
Manual time setting
- Press and hold down the “SET/MODE” button for 2 seconds, the 12/24 hour mode display starts to flash. Now use the “+” and “-” buttons to set the correct 12/24 hour mode.
- Press “SET/MODE” to confirm your setting, the Hour display starts to flash. Now use“+” and “-” buttons to set the correct hour.
- Press “SET/MODE” to confirm your setting, the Minute displays starts to flash. Now use “+” and “-” buttons to set the correct minute.
- Press “SET/MODE” to confirm your setting and to end the setting procedures, enter the clock mode.
F.Y.I.:
- After 20 seconds without pressing any button, the clock switches automatically from Set Mode to Normal Time Mode.
- When the WIFI connection is successful, the time will be automatically updated to the network time, the symbol will display, at the time of setting, and there is no need to set the time.
Setting the daily alarms
- Press once “ALARM” button, the display conversion to alarm activation mode. In this mode, press the “ALARM” button again to activate the alarm function, at the same time, the sound of “BI” sounded, while the alarm icon is displayed which means alarm has been activated. And then press “ALARM” button again, you can turn off the alarm function, the alarm icon does not shows.
- Press and hold down “ALARM” button for 2 seconds until Alarm Time hour display starts to flash. Use the“+” and “-” buttons to set the required hour.
- Press “ALARM” button to confirm your setting, the Minute display starts to flash. Use the “+” and “-” buttons to set the required minute.
- Press “ALARM” button to confirm your setting, the snooze time of the Alarm starts to flash. Use the “+” and “-” buttons to set the minute of snooze you need.
- Press “ALARM” button to confirm your setting and to end the setting procedure
F.Y.I.:
- After 20 seconds without pressing any button the clock switches automatically from setting mode to Normal clock mode.
- The alarm will sound for 2 minutes if you do not deactivate it by pressing any button. In this case the alarm will be repeated automatically after 24 hours.
- Rising alarm sound (crescendo, duration: 2 minutes) changes the volume 4 times whilst the alarm signal is heard.
- The snooze time setting range : 5 ~ 60MIN, OFF, when set to OFF, means no snooze function. Snooze time
Switching off the alarm signal
While the alarm is sounding, press any button except the “SNOOZE/LIGHT”
button or press hold the “SNOOZE/LIGHT” button for 3 seconds to stop the alarm
signal.
Snooze Function
- While the alarm is sounding, press the “SNOOZE/LIGHT” button once to activate the snooze function. The alarm signal sounds again after already been set.
- In snooze mode, press any button except the “SNOOZE/LIGHT” button or press hold the “SNOOZE/LIGHT” button for 3 seconds to exit the snooze mode.
F.Y.I.:
When the snooze function is set to OFF, while the alarm is sounding, pressing
“SNOOZE/LIGHT” does not have this snooze function.
Maximum/Minimum Temperature/Humidity
- To toggle indoor/outdoor maximum, minimum temperature and humidity data, press the “MEM” button: Once to show the maximum temperature and humidity values. Twice to sow the minimum temperature and humidity values Three times to return to the current temperature and humidity levels
- To reset the maximum and minimum temperature and humidity, press and hold down the “MEM” button about 2 seconds. This will reset all minimum and maximum data recorded to the current displayed values.
F.Y.I.:
If the temperature reading is below ranges, the LL.L will be displayed. If the
temperature reading is above ranges, the HH.H will be displayed.
Battery charging and power-on and power-off
- When the main unit is in the shutdown state, Press and hold the “ ” button on the side for more than 3 seconds to turn on the product. Similarly, in the startup state, press and hold the “ ” button for more than 3 seconds to turn off the machine
- The built-in battery of the main unit has a power display. The display of four cells indicates that the battery is fully charged, and the display of one cell indicates that the battery is low.
- If only the battery frame is displayed and blinks, it means that the battery power is exhausted, and the product will automatically shut down and enter the standby state. At this time, the external power supply must be connected for charging. The main unit will only display the battery label when charging when it is off.
- When the main unit is connected to the external power supply, it will automatically charge the built-in lithium battery, and the battery icon will automatically change the animation display to indicate that it is charging. When it is fully charged, the battery icon will automatically display the full charge status of four cells.
Background lighting
- If the product is powered by batteries, Press the “SNZ/LIGHT” button. Backlight lit 15 seconds.
- When the power supply of the product is inserted into the power supply adapter, the battery will automatically disconnect the power supply, and the backlight will always be bright.
Press the “SET/MODE” button to adjust the brightness of the backlight, you can adjust the 4 state: 3 different brightness backlight and close the backlight. Users can choose according to the personal preferences of different brightness backlight or turn off the backlight. When the backlight is in the dark brightness or closed state, you can Press the “SNOOZE/LIGHT” button to lighten the maximum brightness of backlight for 15 seconds.
APP interface description
- After the pairing is completed, the APP will automatically jump to the main interface, the product will automatically update the network time, and report the indoor temperature and humidity, and the temperature of the three outdoor channels. The APP interface will refresh the data.
- The APP can view the historical record of the reported data. Click the record icon at the bottom left to enter the historical record interface. Click the setting icon at the bottom right to make various settings. The product will change in real time according to the settings.
FAQ
1. How do I change the time format?
To change the time format, navigate to the settings using the SET/MODE
button and adjust the time format to your preference.
2. What should I do if the outdoor sensor range is limited?
If the wireless range is limited, try repositioning the main unit and outdoor
sensor for better signal reception. Ensure there are no obstructions between
the units.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>