Kenmore 580.72087200 Through the Wall Air Conditioner Owner’s Manual
- July 27, 2024
- Kenmore
Table of Contents
Kenmore 580.72087200 Through the Wall Air Conditioner
Specifications
- Model Numbers: 580.72087200, 580.72107200, 580.72127200
- Brand: Kenmore
- Manufacturer: Sears, Roebuck and Co.
- Country of Origin: United States
Product Usage Instructions
SAFETY
IMPORTANT SAFETY INSTRUCTIONS
The safety instructions below will tell you how to use your room air
conditioner to avoid harm to yourself or damage to your ROOM AIR CONDITIONER.
WARNING: FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance. Read product labels for flammability
and other warnings.
WARNING: PREVENT ACCIDENTS
To reduce the risk of fire, electrical shock, or injury to persons when using
your air conditioner, follow basic precautions, including the following:
-
Be sure the electrical service is adequate for the model you have chosen.
-
If the air conditioner is to be installed in a window, you will probably want to clean both sides of the glass first If the window is a triple-track type with a screen panel included, you may want to remove the screen completely before installation.
-
Be sure the air conditioner has been securely and correctly installed according to the instructions in this manual.
-
Save this manual and installation instructions for possible future use in removing or reinstalling this unit
-
Use gloves when handling the air conditioner.
-
Be careful to avoid cuts from sharp metal fins on front and rear coils.
WARNING: ELECTRICAL INFORMATION
The complete electrical rating of your new room air conditioner is stated on
the serial plate. Refer to the rating when checking the electrical
requirements.
- Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
- Your air conditioner must be plugged into a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle.
- Do not run air conditioner with packing sheet of the back of the sleeve, and packing corner and blue tape of the air conditioner. This could result in mechanical damage within the air conditioner.
- Do not use an extension cord or an adapter plug.
WARNING: Avoid fire hazard or electric shock. Do not use an extension cord or an adapter plug. Do not remove any prong from the power cord.
ENERGY SAVING IDEAS
- The capacity of the room air conditioner must fit the room size for efficient and satisfactory operation.
- Install the room air conditioner on the shady side of your home. A window that faces north is best because it is shaded most of the day.
- Do not block air flow inside with blinds, curtains, or furniture; or outside with shrubs, enclosures, or other buildings.
- Close the floor and wall registers and the fireplace damper so cool air does not escape up the chimney and into the duct work.
- Keep blinds and drapes in other windows closed during the sunniest part of the day.
- Clean the air filter as recommended in the MAINTENANCE section of this manual.
- Proper insulation and weather stripping in your home will help keep warm air out and cool air in.
- External house shading with trees, plants or awnings will help reduce the air conditioner’s work load.
- Operate heat producing appliances such as ranges, washers, dryers, and dishwashers during the coolest part of the day.
ELECTRICAL REQUIREMENTS
OBSERVE ALL LOCAL CODES AND ORDINANCES. DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE THE POWER SUPPLY CORD GROUND PRONG. ELECTRICAL GROUND IS REQUIRED ON
THIS APPLIANCE. A 208/230-volt and 115-volt 60 Hz, AC only, 15A fused and
properly grounded electrical supply is required. A time delay fuse or time
delay circuit breaker is recommended. Use a dedicated circuit, serving only
this appliance.
DO NOT USE AN EXTENSION CORD.
RECOMMENDED GROUNDING METHOD
For your personal safety, this appliance must be grounded. This appliance has
a power supply cord with a 3-prong grounding plug. To minimize possible shock
hazard, the cord must be plugged into a mating grounding type wall receptacle
and grounded in accordance with the National Electrical Code (ANSI/NFPA 70)
latest edition and all local codes and ordinances. If a mating wall receptacle
is not available, it is the personal responsibility and obligation of the
customer to have a properly grounded 3-prong wall receptacle installed by a
qualified electrician.
WARNING:
- Electrical Shock Hazard
- Plug into a grounded 3 prong outlet.
- Do not remove ground prong.
- Do not use an adapter.
- Do not use an extension cord.
- Failure to follow these instructions can result in death, fire, or electrical shock.
Installation:
Before starting the installation, ensure you have reviewed the installation
requirements detailed in the manual.
- Procedure A: Follow steps 1 to 7 for proper installation.
- Procedure B: Refer to steps 1 to 9 for an alternative installation method.
- Procedure C: Detailed steps from 1 to 11 for another installation approach.
INSTALLATION REQUIREMEN TS
If you use an existing wall sleeve, you should measure its dimensions. Install
the new air conditioner according to these installation instructions to
achieve the best performance. All wall sleeves used to mount the new air
conditioner must be in good structural condition and have a rear grille to
securely attach the new air conditioner. (FIG. 1) With the Kenmore folding
sleeve, you can maintain the best performance of the new air conditioner.
ELECTRICAL SERVICE
Check your available electrical service. The power supply available must be
the same as that shown on the unit nameplate (found on left side of cabinet).
All models are equipped with a 3-prong service plug to provide proper service
and safe positive grounding. Do not change plug in any way. Do not use an
adapter plug. If your present wall outlet does not match your plug, call a
qualified electrician to make the necessary corrections. SAVE CARTON for
storage and his OWNER’S MANUAL for future reference. The carton is the best
way to store unit during winter or when not in use.
INSTALLATION HARDWARE
CAUTION
To avoid risk of personal injury, property damage, or product damage due to
the weight of this device and sharp edges that may be exposed
- Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit.
- To prevent injury or strain, use proper lifting and carrying techniques when moving unit.
- Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit over an extended period of time.
- Handle air conditioner with care. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp metal fins of front and rear coils.
- Make sure air conditioner does not fall during installation.
REQUIRED TOOLS:
- Tight Fitting gloves
- Standard screwdriver
- Phillips screwdriver
- Pliers
- Sharp knife
- 3/8-inch open end wrench or adjustable wrench
- 1 /4-inch hex socket and ratchet
- Tape measure
- Electric drill
- 1 /4-inch drill bit
CAUTION
We strongly recommend the removal of the old wall sleeve and the installation
of a new Kenmore folding Wall Sleeve. If you decide to keep the existing wall
sleeve, you have to redirect the louvers at the back of the wall sleeve
illustration. The use of pliers is recommended. If you DO NOT redirect, you
run the risk of poor performance or product failure. This is not covered under
the terms of the Kenmore warranty.
- Pick a location which will allow the conditioned air to blow into the area you want. Good installation with special attention to the proper position of the unit will lessen the chance that service will be needed.
- Assemble the folding sleeve for this unit according to the instructions provided.
ITEMS IN INSTALLATION HARDWARE
You may not need all parts in the kit. Discard unused parts
ITEM (inches) | Qty. |
---|---|
Plastic grille | 26314 X 16112 |
Horizontal Insulation Strips | 131s X 513 X 273115 |
13;g X 13/s X 273115 | 1 |
Around Insulation Strips | 1313 X 314 X 611/2 |
13;gx 13;8x611;2 | 1 |
Sunnort Block | 1314 X 13;3 X 45115 |
Baffle | 14x4112x118 |
Shim | 13x1x3;4 |
Trim Frame | |
Washer Screw | |
Nuts(Plastic) |
HOW TO INSTALL
- Identify the existing wall sleeve before installing the unit from the listed below.
Brand| Wall Sleeve Dimensions (inches)
---|---
Width| Height| Depth
White-Westinghouse|
15-1/4
| 16, 17-1/2
or 22
Frigidaire
Carrier (52F series)
| 25-1/2
General Electric
/Hotpoint
| 26| 15-5/8| 16-7/8
Whirlpool| 25-7/8| 16-1/2| 17-1/8
or 23
Fedders/Emerson| 27| 16-3/4| 16-3/4
or 19-3/4
Sears/Kenmore| 25-7/8| 15-17/32| 16-23/32
Emerson/Fedders| 26-3/4| 15-3/4| 15
Carrier (51S Series)| 25-3/4| 16-7/8| 18-5/8
Friedrich| 27| 16-3/4| 16-3/4
NOTE: All wall sleeves used to mount the new Air Conditioner must be in sound structural condition and have a rear grille that securely attaches to sleeve, or rear flange that serves as a stop for the Air Conditioner,
- Remove old air conditioner from existing wall li:II sleeve.
- Clean the interior of an existing sleeve. (Do not disturb seals.)
- Wall sleeve must be securely fastened in wall Ii.I before installing the air conditioner. Use the nails or screws through sleeve into wall, if needed. Repaint sleeve if needed.
- Prepare the wall sleeve for installation of the unit. If you plan to use your existing wall sleeve, and it is not Kenmore, use procedure B or C below.
Procedure| Brand| Depth(inches)
---|---|---
A| Sears/Kenmore| 16-23/32
B
| White-Westinghouse Frigidaire Carrier (52F series)| 16, 17-1/2
or 22
General Electric
/Hotpoint
| 16-7/8
Whirlpool| 17-1/8 or 23
Carrier (51S series)| 18-5/8
C
| Fedders/Emerson| 16-3/4
or 19-3/4
Emerson/Fedders| 15
Friedrich| 16-3/4
6. Install new unit into wall sleeve.
CAUTION: When installation is completed, replacement unit MUST have a rearward slope as shown.
PROCEDURE A
- If you are using a new Kenmore folding sleeve with your unit, skip to step 3. Otherwise, install the plastic grille from the kit. Cut the plastic grille to 25-1 /2″ wide and 15-1 /4″ high. Place the plastic grille to the inside of the wall sleeve at the rear flange.
- Fasten the 4 washer screws to secure the grille to the wall sleeve. If you need plastic nuts to mount plastic grille to the inside of the wall sleeve, there are plastic nuts in the installation kit. The nuts are installed from the inside of the sleeve and are pressed into the square holes of the rear flanges.
- Remove the backing from the Horizontal Insulation strip 1318 x 318 x 273116 and attach that to the inside bottom of the sleeve as shown below. Remove the backing from the Around Insulation strip 1318 x 314 x 61112 and attach that to the inside front of the sleeve as shown below.
- Install the new unit into the wall sleeve.
- To assemble trim, snap the tab of each piece into the slot of the other piece as shown below. Slide trim over the front of the air conditioner until trim is flush with sleeve as shown below.
CAUTION
- Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit.
- When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils.
- Make sure air conditioner does not fall during removal.
PROCEDURE B
- Redirect the ° louvers at the back of the wall sleeve to 60 angle as shown in the FIG 7. The use of pliers is recommended.
- If the wall sleeve already has a rear grille, skip to step 4. If the wall sleeve does not have a rear grille or louvered panel, install the plastic grille from the kit Cut the plastic grille to 25-1 /2″ wide and 15-1/4″ high. Place the plastic grille to the inside of the wall sleeve at the rear flange.
- Fasten the 4 washer screws to secure the grille to the wall sleeve. If you need plastic nuts to mount plastic grille to the inside of the wall sleeve, there are plastic nuts in the installation kit The nuts are installed from the inside of the sleeve and are pressed into the square holes of the rear flanges.
- Remove the backing from the Horizontal Insulation strip 1318 x 5is x 273116 and attach that to the inside bottom of the sleeve as shown below. Remove the backing from the Around Insulation strip 1% x 314 x 61112 and attach that to the inside front of the sleeve as shown below.
- If the depth of your existing wall sleeve is less than or equal to 18″, skip to step 7. Otherwise, cut the baffles and the support blocks according to length “A” in the table below.
- Remove the backing from the support blocks and attach them to the inside of the wall sleeve as shown FIG 8. Slide the baffle into slots of the support blocks.
- Install the new unit into the wall sleeve.
- To assemble trim, snap the tab of each piece. into the slot of the other piece as shown below. Slide trim over the front of the air conditioner until trim is flush with sleeve as shown below.
CAUTION
- Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit.
- When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils.
- Make sure air conditioner does not fall during removal.
PROCEDURE C
- Redirect the ° louvers at the back of the wall sleeve to 60 angle as shown in the FIG 14. The use of pliers is recommended.
- If the wall sleeve already has a rear grille, skip to step 4. If the wall sleeve does not have a rear grille or louvered panel, install the plastic grille from the kit. Cut the plastic grille to 26-1 /2″ wide and 15-1/2″ high. Place the plastic grille to the inside of the wall sleeve at the rear flange.
- Fasten the 4 washer screws to secure the grille to the wall sleeve. If you need plastic nuts to mount plastic grille to the inside of the wall sleeve, there are plastic nuts in the installation kit. The nuts are installed from the inside of the sleeve and are pressed into the square holes of the rear flanges.
- Remove the backing from the Horizontal Insulation strip 1318 x Ha x 273116 and attach that to the inside bottom of the sleeve as shown below. Remove the backing from the Around Insulation strip 13;g x Ha x 61112 and attach that to the inside front of the sleeve as shown below.
- If the depth of your existing sleeve is less than or equal to 18″, skip to step 7. Otherwise, cut the baffles and the support blocks according to Length “A” in the table below.
- Remove the backing from the support blocks and attach them to the inside of the wall sleeve as shown FIG 19. Slide the baffle into slots of the support blocks
- Remove the backing from the 13″ shim strips and attach them as shown below in Fig. 21. The higher portion of shim is to be placed in front of the rib on the base of wall sleeve.
- Install the new unit into the wall sleeve
- To assemble trim, snap the tab of each piece into the slot of the other piece as shown below. Slide trim over the front of the air conditioner until trim is flush with sleeve as shown below.
CAUTION
- Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit.
- When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils.
- Make sure air conditioner does not fall during removal.
Operation:
Learn about the functioning and operation of your air conditioner:
- How and Why: Understand the operation principles.
- Normal Sounds: Familiarize yourself with common operational sounds.
- Capacity and Running Time: Know the cooling capacity and recommended running time.
HOW AND WHY
Your room air conditioner provides the following functions to make hot weather
living more comfortable:
- Cools and circulates room air.
- Lowers humidity by removing excess moisture.
- Filters out summertime dust, dirt, and some airborne impurities.
The air conditioner performs these functions by drawing room air through a filter which traps dust and dirt particles. The air then passes over a cooling coil which refrigerates the air and removes excess moisture. The same air is then returned to the room- cooler, drier, and cleaner. Moisture removed from the room air is carried to the outside and evaporated. Your air conditioner is designed to be easy to operate and to provide plenty of cooling power.
NORMAL SOUNDS FIG, 23
Aside from the regular fan motor and compressor sounds coming from your air
conditioner, you will once in a while hear a pinging sound. This is the result
of moisture being picked up from the air in the room and thrown against the
air conditioner’s fan. This is normal and should not be cause for concern.
Also, do not be alarmed if you hear a slight hissing or gurgling sound coming
from your air conditioner after it is off. These are normal coolant noises.
CAPACITY AND RUNNING TIME
Proper unit size is important in deciding the desired comfort for the area you
want to cool. The proper size is determined by the number of square feet in
the area to be cooled. Whenever the heat or humidity load is above normal the
air conditioner must run longer and more often to keep the desired temperature
you have selected. Under heavy heat load conditions the air conditioner may
need to run constantly to keep the temperature you want At times using the MED
FAN setting to circulate the room air may make it comfortable even though you
do not have the air conditioner set to cool the air. This will decrease your
cost of use.
FEATURES
THE UNIT
- CABINET
- HORIZONTAL AIR DEFLECTOR (Vertical Louver)
- VERTICAL AIR DEFLECTOR (Horizontal Louver)
- AIR DISCHARGE
- FRONT GRILLE
- INLET GRILLE (Air Intake)
- AIR FILTER
- VENT CONTROL
USING THE AIR CONDITIONER
To reduce the risk of fire, electric shock, or injury to persons, read the
important SAFETY instructions section before operating this appliance.
To begin operating the air conditioner after installation, follow these steps:
- Plug in the air conditioner. (To prevent electrical hazards, do not use an extension cord or an adapter plug.)
- Set the TEMP control to the coolest setting.
- Set the MODE control at the highest COOL level.
- Adjust the louvers for comfortable air flow.
- Once the room has cooled, adjust the TEMP and MODE control to the setting you find most comfortable.
NOTE : If the air conditioner is turned off, wait 3 minutes before restarting. This allows pressure inside the compressor to equalize. Failure to wait 3 minutes before restarting may cause inefficient operation. If you move the TEMP control to a warmer, then immediately back to a cooler setting, the unit will shut off. Wait 3 minutes before restarting. Refer to the AIR CONDITIONER FEATURES section for other settings.
VENT CONTROL
The Vent Control allows the air conditioner to either recirculate inside air
(CLOSE) or exhaust air to the outside (OPEN). (FIG. 25)
- The CLOSE position is used when maximum cooling is desired. It may also be used for air recirculation without cooling when the air conditioner is set in the FAN position.
- The OPEN position removes stale air from the room and exhausts it to the outside. Fresh air is drawn into the room through your home’s normal air passages.
- The OPEN or CLOSE position can be used with any fan selection.
CONTROLS
- FOR NORMAL COOLING
1. Turn the Operation Knob to the High Cool from the Low Cool setting.
2. Set the Thermostat control to the desired temperature mark 5 (the mid-point is a good starting position). If the room temperature is not satisfactory after a reasonable time, adjust the control to a cooler or warmer setting, as appropriate.
- FOR MAXIMUM COOLING
1. Turn the Operation Knob to the High Cool setting.
2. Set the Thermostat control to the largest 9 temperature mark.
- FOR QUIETER OPERATION
1. Turn the Operation Knob to the Low Cool setting.
2. Set the Thermostat control as needed.
- ENERGY SAVER (optional)
- On: Both the fan and the compressor turn on and turn off together while operation knob is set to the Cool position. You can get the more economical operation.
- Off: The fan runs constantly while operation knob is set to the Cool position. You can access the Energy Saver switch when you open the inlet grille.
HORIZONTAL AIR-DIRECTION ADJUSTMENT
- The horizontal air direction is adjusted by moving vertical louver.
- The vertical louver control levers are located in the right and left side of the air discharge.
VERTICAL AIR-DIRECTION ADJUSTMENT
- The vertical air direction is adjusted by moving the horizontal louvers.
Maintenance:
Maintain your air conditioner for optimal performance:
- Air Filter Cleaning: Regularly clean the air filter for efficient airflow.
- Air Conditioner Cleaning: Keep the unit clean for better air quality.
- Front Grille Maintenance: Learn how to remove and replace the front grille.
AIR FILTER CLEANING
The Air Filter will become dirty as it removes dust from the inside air. It
should be washed at least every 2 weeks. If the Air Filter remains full of
dust, the air flow will decrease and the cooling capacity will be reduced,
possibly damaging the unit.
- Pull the inlet grille forward and pull out the air filter. (FIG. 28)
- Wash the Air Filter under the faucet with warm water. Be sure to shake off all the water before replacing the filter. (FIG. 29)
AIR CONDITIONER CLEANING
Clean the front grille and inlet grille by wiping with a cloth dampened in a
mild detergent solution. The cabinet may be washed with mild soap or detergent
and lukewarm water, then polished with liquid appliance wax. To ensure
continued peak efficiency, the condenser coils (outdoor side of the unit)
should be checked periodically and cleaned if they become clogged with soot or
dirt from the atmosphere. Brush or vacuum exterior coils to remove debris from
fins.
HOW TO REMOVE THE FRONT GRILLE
- Open the inlet grille.
- Remove the screw securing the Front Grille.
- Push the grille up from the bottom and pull the top of the grille away from the case to lift the top tabs out of their slots.
HOW TO REPLACE THE FRONT GRILLE
Attach the front grille to the cabinet by inserting the tabs on the grille
into the slots on the front of the cabinet. Push the grille in until it snaps
into place.
T roubleshooting:
If you encounter issues, refer to the troubleshooting section before seeking
service.
BEFORE CALLING FOR SERVICE
Check the following list to be sure a service call is really necessary. A
quick reference to this manual may help you avoid an unneeded service call.
THE AIR CONDITIONER WILL NOT OPERATE
Wall plug disconnected. | Push plug firmly into wall outlet |
---|---|
House fuse blown or circuit breaker tripped. | Replace fuse with time delay |
rvoe or reset circuit breaker
Power is OFF.| Push the power button.
Unit was turned off and then on too quickly.| Set unit off and wait 3 minutes
before restarting.
TEMP Control set warmer than room temperature.| Set TEMP Control to a lower
number
AIR FROM UNIT DOES NOT FEEL COLD ENOUGH.
FAN SPEED set at LOW | Push FAN SPEED button to set at HL |
---|---|
TEMP Control set too warm. | Set TEMP Control to a lower temperature. |
Room temperature below 70°F (21°C). | Cooling may not occur until room |
temperature rises above 70°F (21°C).
Temperature sensing tube touching evaporator coil, located behind front
grille.| Straighten tube away from evaporator coil.
THE AIR CONDITIONER COOLING, BUT ROOM IS TOO WARM – ICE FORMING ON COOLING COIL BEHIND INLET GRILLE.
Outdoor temperature below 70°F (21°C).| To defrost the coil, set the MODE to
FAN, FAN speed to High.
---|---
Air filter may be dirty.| Clean air filter Refer to Maintenance section of
owner’s manual.
TEMP Control set too low.| To defrost the coil, set the MODE to Cool, Fan
speed to high, and the Temp control to a higher temperature.
THE AIR CONDITIONER COOLING, BUT ROOM IS TOO WARM
Dirty air filter – air restricted.| Clean air filter Refer to Maintenance
section of owner’s manual.
---|---
TEMP Control set too warm.| Set TEMP Control to a lower temperature.
Front of unit is blocked by drapes, blinds, furniture, etc. Air distribution
is restricted.| Clear blockage in front of unit
Doors, windows, registers, etc. open. Cold air escapes.| Close doors, windows,
registers, etc.
Unit recently turned on in hot room.| Allow additional time to remove stored
heat from walls, ceiling, floor, and furniture.
THE AIR CONDITIONER TURNS ON AND OFF RAPIDLY.
- Outside temperature is extremely hot: Set FAN SPEED on HI to bring air past cooling coils faster
NOISE WHEN UNIT IS COOLING.
- Sound of fan hitting water – from the moisture removal system. This is normal when humidity is high. Close doors, windows, and registers.
- Window vibration – poor installation. Refer to installation instructions or check with installer
WATER DRIPPING INSIDE ROOM WHEN UNIT IS COOLING.
- The air conditioner is improperly installed.: Tilt air conditioner slightly to the outside to allow water drainage. Refer to installation instructions or check with installer
WATER DRIPPING OUTSIDE WHEN UNIT IS COOLING.
-
* The unit is removing large quantities of moisture from humid room.: This is normal during excessively humid days.
Master Protection Agreements
Congratulations on making a smart purchase. Your new Kenmore® product is
designed and manufactured for years of dependable operation. But like all
products, it may require preventive maintenance or repair from time to time.
That’s when having a Master Protection Agreement can save you money and
aggravation.
Purchase a Maser Protection Agreement now and protect yourself from unexpected
hassle and expense.
The Master Protection Agreement also helps extend the life of your new
product. Here’s what’s included in the Agreement:
- Expert service by our 12,000 professional repair specialists
- 0 Unlimited service and no charge for parts and labor on all covered repairs
- 0 “No-lemon” guarantee – replacement of your covered product if four or more product failures occur within twelve months
- 0 Product replacement if your covered product can’t be fixed
- 0 Annual Preventive Maintenance Check at your request – no extra charge
- 0 Fast help by phone – phone support from a Sears technician on products requiring in-home repair, plus convenient repair scheduling
- 0 Power surge protection against electrical damage due to power fluctuations
- Rental reimbursement if repair of your covered product takes longer than promised
Once you purchase the Agreement, a simple phone call is all that it takes for you to schedule service. You can call anytime day or night, or schedule a service appointment online. Sears has over 12,000 professional repair specialists, who have access to over 4.5 million quality parts and accessories. That’s the kind of professionalism you can count on to help prolong the life of your new purchase for years to come. Purchase your Master
Protection Agreement today!
Some limitations and exclusions apply. For prices and additional information
call 1-800-827-6655.
Sears Installation Service
For Sears professional installation of home appliances, garage door openers,
water heaters, and other major home items, in the U.S.A. call 1-800-4-MY-HOME®
Get it fixed, at your home or ours!
Your Home
For repair- in your home-of all major brand appliances, lawn and garden
equipment, or heating and cooling systems, no matter who made it, no matter
who sold it! For the replacement parts, accessories and owner’s manuals that
you need to do-it-yourself.
For Sears professional installation of home appliances and items like garage door openers and water heaters.
1-800-4-MY-HOME®
(1-800-469-4663)
Call anytime, day or night (U.S.A. and Canada)
www.sears.com
www.sears.ca
Our Home
For repair of carry-in items like vacuums, lawn equipment, and electronics,
call or go on-line for the location of your nearest
Sears Parts & Repair Center.
1-800-488-1222
Call anytime, day or night (U.S.A. only)
www.sears.com
To purchase a protection agreement (U.S.A.) or maintenance agreement (Canada) on a product serviced by Sears:
- 1-800-827-6655 (U.S.A.)
- 1-800-361-6665 (Canada)
WARRANTY
FULL ONE YEAR WARRANTY ON THROUGH-THE-WALL AIR CONDITIONER
For one year from the date of purchase, when this air conditioner is operated
and maintained for normal room cooling according to instructions in this
owner’s manual, Sears will repair this air conditioner, free of charge, if
defective in material or workmanship.
WARRANTY SERVICE IS AVAILABLE BY CONTACTING SEARS SERVICE AT
1-800-4-MY-HOME®. This warranty applies only while this product is in use in
the United States. This warranty gives you specific legal rights, and you may
also have other rights which vary from state to state.
Sears, Roebuck and Co., D/817WA, Hoffman Estates, IL 60179 U.S.A.
Au Canada pour service en franc;ais:
1-800-LE-FOYERMC
( 1-800-533-6937)
www.sears.ca
® Registered Trademark
TM Trademark
SM Service Mark of Sears, Roebuck and Co.
Part No.: 3828A20039Y
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
www.sears.com
FAQ
Q: Can I use an extension cord with this air conditioner?
A: To avoid fire hazard or electric shock, it is recommended not to use an
extension cord or adapter plug with this unit.
Q: Where can I find genuine replacement parts for the Kenmore
580.72087200?
A: Genuine replacement parts can be found on the Appliance Factory Parts
website. Ensure to select the appropriate part for your model number.
References
- Repair Your Grill: Shop Replacement Parts for 24,880 Models
- Kenmore Air Conditioner Parts - Select From 262 Models
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>