NERIUS YSYK Metal Multi Head Clamp Lamp User Manual

July 26, 2024
NERIUS

NERIUS YSYK Metal Multi Head Clamp Lamp

Product Information

Specifications

  • Input Voltage: 100-240V
  • Plug Options: EU plug/UK plug/CN plug: 220-240V
  • Input Power: Max 24W
  • Color Temperature: 2700K-6500K
  • Sensing Distance: 3-8 meters
  • Materials: Aluminum+ABS+PC
  • Input Port: DC5.5*2.1
  • Stepless Brightness: 5%-100%
  • Working Humidity: 0%-85% RH
  • Working Temperature: -10°C to +40°C

Product Usage Instructions

Installation Instructions

  1. Fix the Clamp on the desktop.
  2. Align the lamp column and insert it into the base, tighten and secure the hand screws.
  3. Insert and fix the raised part of the tube in the same direction as the round hole of the support rod.
  4. Adjust the appropriate angle and tighten the fixing screws.

Product Functions

  • Touch Control
  • Remote Control
  • Memory Function: Remembers color temperature and brightness settings when turned off.
  • Pairing: Press and hold the remote within 20 seconds of powering on to pair or unpair.

Remote Controller Instructions

  • Night Mode
  • Brightness + Color Temperature + Timed Shutdown Mode
  • Reading Mode
  • Work Mode

Additional Notes

FCC Statement: The device meets general RF exposure requirements for portable use without restriction.

Product Specification

  • Input Voltage:100-240V
  • EU plug/UK plug/CN plug: 220-240V
  • Input Power: Max 24W
  • Color Temperature:2700K-6500K
  • Sensing Distance: 3-8 meters
  • Materials: Aluminum+ABS+PC
  • Input Port: DC5.5*2.1
  • Stepless Brightness:5%-100%
  • Working Humidity:0%~85% RH
  • Working Temperature:-10℃~+40℃

Accessories

  • Lamp head * 1
  • Adapter * 1
  • Hand tightened screw * 1
  • Lamp body * 1
  • Instructions *1
  • Clamp base * 1
  • Remote control * 1

Notes

  1. Waterproof Caution: This product is not waterproof. Avoid use in humid environments.
  2. Heat Source Caution: Avoid installing this product near heat sources such as air conditioner outlets, heating outlets, or humidifiers, as drastic temperature changes can occur. The working temperature range for the product is -10°C to 40°C.
  3. Disassembly Warning: Do not attempt to disassemble this product as it may cause damage to internal parts.

Product Size

Three headlights + Bimetallic uranium design
Lamp head metal uranium can swing up and down 170°,
And lamp pillar metal uranium can swing up and down 200°. And the left and right lamp heads can be uniformly rotated 270°. The lamp body can be rotated 360°.

Product Functions

Function 1: Touch Control

  1.  Short press“ ”: Press“ ”once to cycle through(lamp and auxiliary lamp simultaneously on → main lamp only on → auxiliary lamp only on → off). When turning on or off, it’s a gradual transition, not instant.
  2.  Single press“ ”: Default maximum brightness when turned on. Short press to decrease brightness by one level (no response when already at minimum brightness), total of five levels. Long press for continuous brightness decrease.
  3.  Single press“ ”: Short press to increase brightness by one level (no response when already at maximum brightness), total of five levels. Long press for continuous brightness increase.
  4.  Single press“ ”: Short press to toggle color temperature, total of five levels. Long press for continuous color temperature adjustment.

Function 2: Remote Control

Function 3: Memory Function

Regardless of power status, the color temperature and brightness when turned off will be remembered when turned back on. (Applies to both remote and button modes).

Function 4: Pairing

Pairing: Within 20 seconds of lamp powering on, press and hold remote “ ” for 3 seconds to pair. Successful pairing is confirmed by a single flash on the lamp head. Unpairing: After 20 seconds of lamp powering on, press and hold remote “ ” for 3 seconds to unpair. Successful unpairing is confirmed by four flashes on the lamp head. Any remote can control the lamp after unpairing.

Product Schematic

FCC Statement

  1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
  2. This device may not cause harmful interference.
  3. This device must accept any interference received, including interference that may cause undesired operation.
  4. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Note: This equipment has been tested and found to comply with the limits for a class B digital device, under Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.

If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.
  • The device has been evaluated to meet general RF exposure requirements.
  • The device can be used in portable exposure conditions without restriction.

FAQ

Q: How do I pair the remote with the lamp?

A: Press and hold the remote within 20 seconds of powering on to pair. Successful pairing is confirmed by a single flash on the lamp head.

Q: Can I control the lamp without the remote?

A: Yes, you can control the lamp using touch controls even without the remote.

Read User Manual Online (PDF format)