SIEMENS RTLS4030T Industrial Identification and Locating Transponder Instruction Manual
- July 27, 2024
- SIEMENS
Table of Contents
SIMATIC RTLS
Localization systems
SIMATIC RTLS4030T
Operating Instructions
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your
personal safety, as well as to prevent damage to property. The notices
referring to your personal safety are highlighted in the manual by a safety
alert symbol, notices referring only to property damage have no safety alert
symbol. These notices shown below are graded according to the degree of
danger.
DANGER
indicates that death or severe personal injury will result if proper
precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper
precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not
taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by
personnel qualified for the specific task in accordance with the relevant
documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are
capable of identifying risks and avoiding potential hazards when working with
these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the
catalog and in the relevant technical documentation. If products and
components from other manufacturers are used, these must be recommended or
approved by Siemens. Proper transport, storage, installation, assembly,
commissioning, operation and maintenance are required to ensure that the
products operate safely and without any problems. The permissible ambient
conditions must be complied with. The information in the relevant
documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The
remaining trademarks in this publication may be trademarks whose use by third
parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with
the hardware and software described. Since variance cannot be precluded
entirely, we cannot guarantee full consistency. However, the information in
this publication is reviewed regularly and any necessary corrections are
included in subsequent editions.
Introduction
Purpose of the operating instructions
These operating instructions support you when installing and connecting the
SIMATIC RTLS4030T transponder.
The configuration and the integration of the transponders in a network are not
described in these operating instructions.
Scope of validity of the operating instructions
These operating instructions apply to the following transponders:
- RTLS4030T (CE; article number: 6GT2700-3DA03)
- RTLS4030T (FCC/NOM/ANATEL; article number: 6GT2700-3DA13)
- RTLS4030T (CMIIT; article number: 6GT2700-3DA23)
- RTLS4030T (ISED; article number: 6GT2700-3DA33)
Further documentation
You can find the complete documentation for all SIMATIC RTLS products at the
following address: Link:
(https://support.industry.siemens.com/cs/us/en/ps/25277)
Trademarks
The following and possibly other names not identified by the registered
trademark sign® are registered trademarks of Siemens AG: SIMATIC RTLS
Industry Online Support
In addition to the product documentation, the comprehensive online information
platform of Siemens Industry Online Support offers support at the following
Internet address: (https://support.industry.siemens.com/cs/start?lc=en-US)
Apart from news, there you will also find:
- Project information: Manuals, FAQs, downloads, application examples etc.
- Contacts, Technical Forum
- The option submitting a support query: (https://support.industry.siemens.com/My/us/en/)
- Our service offer:
Right across our products and systems, we provide numerous services that
support you in every phase of the life of your machine or system – from
planning and implementation to commissioning, through to maintenance and
modernization.
You will find contact information on the Internet at the following address:
(https://www.automation.siemens.com/aspa_app/?ci=yes&lang=en)
SITRAIN – Training for Industry
The training offer includes more than 300 courses on basic topics, extended
knowledge and special knowledge as well as advanced training for individual
sectors – available at more than 130 locations. Courses can also be organized
individually and held locally at your location.
You will find detailed information on the training curriculum and how to
contact our customer consultants at the following Internet address:
(https://new.siemens.com/global/en/products/services/industry/sitrain/personal.html)
RTLS Technology and Practice (ID-RTLS-TP)
Training and certification
After completing the RTLS certification training, you will be able to plan and
implement small and medium-sized RTLS projects and provide efficient and
multifaceted support in large projects. Your RTLS basics will be strengthened
and, building upon them, you will receive new tools of the trade in order to
offer customers the optimal solution for them. The complete project sequence
is taken as a reference and important steps, resources and work results for
each phase are presented. Comprehensive practical exercises in connection with
troubleshooting techniques and a great deal of input from industrial projects
allow you to internalize a confident approach to working with different types
of localization projects. With the training documents, you also receive
extensive reference material for your daily work.
Link: (https://www.sitrain-learning.siemens.com/EN/en/rw35251/Industrielle-
IdentifikationRTLS-Technologie-und-Praxis)
Security information
Siemens provides products and solutions with industrial security functions
that support the secure operation of plants, systems, machines, and networks.
In order to protect plants, systems, machines and networks against cyber
threats, it is necessary to implement – and continuously maintain – a
holistic, state-of-the-art industrial security concept. Siemens’ products and
solutions form one element of such a concept.
Customers are responsible for preventing unauthorized access to their plants,
systems, machines and networks. These systems, machines and components should
only be connected to the enterprise network or the Internet if and only to the
extent necessary and
with appropriate security measures (firewalls and/or network segmentation) in
place.
You can find more information on protective measures in the area of industrial
security by visiting:
(http://www.siemens.com/industrialsecurity).
Siemens’ products and solutions undergo continuous development to make them
more secure. Siemens strongly recommends performing product updates as soon as
they are available and using only the latest product versions. Use of product
versions that are no longer supported, and failure to apply latest updates may
increase customer’s exposure to cyber threats.
To ensure that you are always informed about product updates, subscribe to the
Siemens Industrial Security RSS feed at: (https://www.siemens.com/cert)
Note on firmware/software support
Check regularly for new firmware/software versions or security updates and
apply them. After the release of a new version, previous versions are no
longer supported and are not maintained.
Security recommendations
General
Note the following security recommendations to prevent unauthorized access:
- Keep the firmware up to date. Check regularly for security updates for the device. You can find information on this at the Industrial Security (https://new.siemens.com/global/en/company/topic-areas/future-ofmanufacturing/industrial-security.html) website.
- Inform yourself regularly about security recommendations published by Siemens ProductCERT (https://new.siemens.com/global/en/products/services/cert.html).
- Evaluate your plant as a whole in terms of security. Use a cell protection concept with suitable products.
- This product requires an additional security concept to prevent unauthorized access.
- Transponder and infrastructure can be configured for radio channels according to IEEE 802.15.4-2015. You will find details in the section “Technical specifications”.
- Ensure that the radio frequencies are not used for other purposes and are not affected by other interfering signals. This should be ensured within the operating range of the localization system.
- Interference in the frequency band used can impair the system and, in extreme cases, lead to localization failure.
Physical access
- Restrict physical access to the device to qualified personnel.
- Disable unused physical interfaces of the device. Unused interfaces could be used to gain access to the operating site.
Recycling and disposal
The products are low in harmful substances, can be recycled and meet the
requirements of the Directive 2012/19/EU for disposal of waste electrical and
electronic equipment (WEEE).
Do not dispose of the products at public disposal sites.
For environmentally compliant recycling and disposal of your electronic waste,
please contact a company certified for the disposal of electronic waste or
your Siemens representative.
Note the different national regulations.
Device description
2.1 Characteristics
SIMATIC RTLS4030T| Characteristics|
---|---|---
| Design| ① Status indicators (LED)
② Battery compartment
General| The transponder is the mobile device for localization in the RTLS
localization
system. It sends position data to gateways which transmit the data to the
Locating Manager server.
2.2 Order data RTLS4030T
Table 2- 1 Order data RTLS4030T
| Article number
---|---
SIMATIC RTLS4030T
including 1 x battery CR123A| CE| 6GT2700-3DA03
FCC, NOM, ANATEL| 6GT2700-3DA13
CMIIT| 6GT2700-3DA23
ISED| 6GT2700-3DA33
2.3 LED status indicator
The operating states of the transponder are indicated by the LED. These can
assume the states from and briefly light up .
LED | Meaning |
---|---|
Red LED is off when the transponder is in operation | |
Red LED lights up once for 1.5 seconds at system startup | |
Flashes red (user LEDs flash) if you trigger flashing via the Locating |
Manager. You can configure the duration and frequency of flashing via the Locating Manager.
2.4 Dimension drawing
Installation & Operation
3.1 Notes on installation
Note
Before you install the transponders, read this section carefully to ensure
problem-free installation and commissioning.
The transponders can only be used in conjunction with the RTLS localization
system. The radio address of the transponder can be obtained from the data
matrix code printed on the transponder.
Install the transponder in such a way that it has a direct line-of-sight
connection to the gateways (360° panorama view). Any type of material can
impact wireless localization.
Wireless localization through metal is not possible. In this case,
localization via wireless reflections can occur, which results in inaccurate
determination of the location.
Check the transponder for damage before installation. The specified operating
temperature ranges must be observed.
The transponder contains one lithium battery.
CAUTION
Fires and burns
Improper handling of batteries can lead result in fires and burns.
The enclosure of the transponder must not be squashed, punctured or exposed to
other mechanical influences. It may only be opened to change batteries.
Never expose the transponder to fire, temperatures above 50 °C or direct
sunlight for an extended period of time.
In dry environments, the transponder battery must be replaced.
Reflections and interferences
The antenna fields are weakened by absorbing materials and reflected by
conducting materials. When electromagnetic fields are reflected or there are
other radio sources, this will result in interferences. These circumstances
will result in incorrect measurements; however, these can be largely detected
and corrected with the appropriate software (e.g. SIMATIC RTLS Locating
Manager). We still recommend that you prevent these influences. Especially
objects that cannot be penetrated by radio waves can cause localization
errors.
Note
Metal surfaces reflect radio waves more than any other types of surfaces.
Water, on the other hand, attenuates radio waves. You should therefore
evaluate your working environment and integration for these influences.
Coexistence and de-sensing
To prevent interfering with each other, radio applications will use different
frequency bands. Use of these frequency bands is subject to state regulation.
Because a frequency range is considered a finite good, technologies were
developed over the years that enable a coexistence of different radio
applications in the same frequency band. These technologies are also used by
SIMATIC RTLS. However, interferences can still be caused by other radio
devices. Arrangements are being made here, too, so that these interferences do
not impact the operation of the RTLS localization system. To keep
interferences to a minimum, the RTLS infrastructure components must not be
installed in the close vicinity of other radio applications. Strong senders in
close vicinity can interfere with the reception, even when they are located in
neighboring frequency bands (de-sensing). This is true, for example, for the
2.4 GHz ISM band and PULSE in the UWB channel 5.
Assembling the transponder prior to starting up
Proceed as follows to assemble the transponder prior to starting up:
- Insert the battery in the battery compartment according to the polarity direction.
- Close the enclosure by first placing the top part into the bottom enclosure and letting it engage on the bottom.
CAUTION
Remove the battery before returning the transponder
Remove the battery before returning the transponder. Batteries must not be
returned.
Battery change
CAUTION
Use approved batteries
Insertion of non-approved or damaged batteries may result in damage to the
transponder or its surroundings. Only use batteries approved by the
manufacturer, see section “Technical specifications (Page 15)”. Before
inserting a battery, make sure that it is not damaged.
Proceed as follows to replace the battery in the transponder:
- Open the enclosure at the designated recess on the left-hand side in an upwards direction using a suitable tool.
- Remove the battery to be replaced and wait 30 seconds before inserting the new battery while maintaining the polarity direction.
- Close the enclosure again until you hear it click into place.
3.2 Cleaning and maintenance
The enclosure may only be opened to change batteries.
The transponder may only be repaired or opened for other types of work by an
authorized maintenance company.
Improper opening or repair of the transponder may result in serious risks for
the user.
Opening the transponder without permission renders the warranty of the Siemens
AG null and void.
Do not clean the enclosure with liquids or abrasive, caustic or flammable
cleaning products.
Technical specifications
Table 4- 1 Technical specifications of the RTLS4030T transponder
6GT2700-3DA03, 6GT2700-3DA13
6GT2700-3DA23, 6GT2700-3DA33
Product name | SIMATIC RTLS4030T |
---|---|
PULSE radio frequencies (localization) | |
Wireless method | IEEE 802.15.4-2015 UWB HRP PHY |
Transmission speed | 850 Kbps |
Operating frequency rated value | 3993.6 MHz (UWB channel 2; CE, FCC, NOM, |
ANATEL)
6489.6 MHz (UWB channel 5; CE, NOM, ANATEL, CMIIT)
Bandwidth| 499.2 MHz
Frequency range| 3100 MHz … 4800 MHz (CE, FCC, NOM, ANATEL)
6000 MHz … 7000 MHz (CE, NOM, ANATEL, CMIIT)
Transmit power| 0.037 mW (-41.3 dBm/MHz)
Range| Maximum 30 m
Accuracy of the localization (typical)| 0.1 m
Antennas| Built-in UWB antenna
PHASE radio frequencies (communication and optional localization)|
Wireless method| IEEE 802.15.4
Transmission speed| 1 Mbit/s
Operating frequency rated value| 2400 … 2480 MHz ISM band
Bandwidth| 2 MHz; data transmission on 802.15.4; channels configurable
Frequency range| 2400 MHz … 2483.5 MHz
Transmit power| Maximum 4 dBm (configurable)
Range| Maximum 50 m
Accuracy of the localization (typical)| 3 m
Antennas| Built-in 2.4 GHz antenna
Supply voltage|
Supply voltage| Battery CR123A: 3 V Lithium rechargeable
Brand: VARTA (1550 mAh) or Panasonic (1400 mAh)
Service life (at 20 ℃)| Standby: 1 year
Operation: 100 % UWB localization with 1 second: 6 months
Permitted ambient conditions|
Ambient temperature
• During write/read access
• Outside write/read access
• During storage| • -10 … +50 °C
• -10 … +50 °C
• -10 … +50 °C
Design, dimensions, weights and connectors|
Dimensions (L x W x H)| 89 x 29 x 30 mm
Weight| 90 g (incl. battery)
Degree of protection| IP54
Fastening method| 2 screws M2.5 or cable ties
Enclosure| Plastic enclosure
Color| Anthracite
Approvals
Note
The specified approvals apply only when the corresponding mark is printed on
the product.
You can check which of the following approvals have been granted for your
product by the markings on the type plate.
You can find the current EU Declaration of Conformity for these products on
the Internet at Siemens Industry Online Support. Link:
(https://support.industry.siemens.com/cs/products?dtp=Certificate&mfn=ps&pnid=14970&lc
=en-
US)
The products described in this document meet the requirements of the following
EU directives:
-
RoHS Directive 2011/65/EU
Directive of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment, official journal of the EU L174, 1 July 2011, pages 88-110 -
Radio Equipment Directive 2014/53/EU (RED)
Directive of the European Parliament and of the Council of 16 April 2014 on the harmonization of the laws of the member states relating to placing radio equipment on the market; official journal of the EU L153, 22 May 2014, pages 62-106
UK Declaration of Conformity
The UK declaration of conformity is available to all responsible authorities
at:
Siemens Aktiengesellschaft
Process Industries and Drives Division,
Process Automation
DE-76181 Karlsruhe
Germany
Importer UK:
Siemens plc,
Manchester M20 2UR
You can find the current UK Declaration of Conformity for these products on
the Internet pages under Siemens Industry Online Support
(https://support.industry.siemens.com/cs/en/en/view/109801531).
The SIMATIC RTLS products described in this document meet the requirements of the following directives/regulation:
- Radio Equipment Regulations: SI 2017/1206 Radio Equipment Regulations 2017, and related amendments
- RoHS Regulations: SI 2012/3032 Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012, and related amendments
RoHS directive (restriction of the use of certain hazardous substances)
The products described in these operating instructions meet the requirements
of the EU directive 2011/65/EU on the restriction of the use of certain
hazardous substances in electrical and electronic equipment.
Applied standard:
- IEC 63000
Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances
The products described in this document meet the requirements of the applied standards:
Article 3 (1) a) Protection of health and safety
-
EN 62368-1
Equipment for audio/video, information and communication technology – Part 1: Safety requirements -
EN 62311
Assessment of electronic and electrical equipment related to human exposure restrictions in electromagnetic fields (0 Hz – 300 GHz)
The products described in these operating instructions meet the requirements of EU directive 2014/30/EU “Electromagnetic Compatibility” according to the designated standards for the following areas of application.
Article 3 (1) b) EMC
-
ETSI EN 301 489-1
Electromagnetic compatibility and radio spectrum matters (ERM) – Electromagnetic compatibility for radio equipment and services – Part 1: Common technical requirements -
ETSI EN 301 489-17
Electromagnetic compatibility and radio spectrum matters (ERM) – Electromagnetic compatibility for radio equipment and services – Part 17: Specific conditions for broadband data transmission systems -
ETSI EN 301 489-33
Electromagnetic compatibility and radio spectrum matters (ERM) – Electromagnetic compatibility for radio equipment and services – Part 33: Special conditions for ultra-wideband (UWB) devices -
EN 55011
Industrial, scientific and medical equipment – Radio-frequency disturbance characteristics – Limits and methods of measurement -
EN 55032 Class A, Class B
Electromagnetic compatibility of multimedia equipment – Emission requirements -
EN 55035
Electromagnetic compatibility of multimedia equipment – Immunity requirements -
EN 61000-6-1
Electromagnetic compatibility (EMC) – Part 6-1: Generic standards – Immunity for residential, commercial and light-industrial environments -
EN 61000-6-2
Electromagnetic compatibility (EMC) – Part 6-2: Generic standards – Immunity for industrial environments -
EN 61000-6-3
Electromagnetic compatibility (EMC) – Part 6-3: Generic standards – Emission standard for residential, commercial and light-industrial environments -
EN 61000-6-4
Electromagnetic compatibility (EMC) – Part 6-4: Generic standards – Emission standard for industrial environments
Article 3 (2) Efficient use of the radio spectrum
-
ETSI EN 300 328
Wideband transmission systems; Data transmission equipment operating in the 2.4 GHz ISM band and using wide band modulation techniques. Harmonized standard covering the essential requirements of article 3.2 of the EU Directive 2014/53/EU -
ETSI EN 302 065-2
Short Range Devices (SRD) using ultra-wideband technology (UWB); Harmonized standard covering the essential requirements of article 3.2 of the Directive 2014/53/EU; Part 2: Requirements for UWB location tracking
FCC information
Siemens SIMATIC RTLS4030T (MLFB 6GT2700-3DA13); FCC ID SCF6032701
This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Caution
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Note
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the
interference at his own expense.
RF Exposure guidance
In order to comply with FCC RF Exposure requirements, this device must be
installed to provide at least 20 cm separation from the human body at all
times.
NOTICE
FCC Regulations §15.521 Technical Requirements Applicable for All UWB Devices.
(a) UWB devices may not be employed for the operation of toys. Operation
onboard an aircraft, a ship or a satellite is prohibited.
ISED information
Siemens SIMATIC RTLS4030T (MLFB 6GT2700-3DA33); IC ID 267X-4030T02 NOTICE
(RSS-Gen Issue 5)
This device complies with license-exempt transmitter(s)/receiver(s) that
comply with Innovation, Science and Economic Development Canada’s licence-
exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) This device must
accept any interference received, including interference that may cause
undesired operation.
Radiation Exposure Statement (RSS-102)
This equipment complies with Canada radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20 cm between the radiator and your body.
EAC (Eurasian Conformity)
Eurasian Economic Union of Republic of Armenia, the Republic of Belarus, the
Republic of Kazakhstan, the Kyrgyz Republic and the Russian
FederationDeclaration of conformity according to the technical regulations of
the customs union (TR CU)
Siemens AG
Digital Industries
Postfach 48 48
90026 NÜRNBERG
GERMANY
C79000-G8976-C520-08
Ⓟ 01/2024 Subject to change
Copyright © Siemens AG 2024.
All rights reserved
SIMATIC RTLS4030T
Operating Instructions, 01/2024, C79000-G8976-C520-08
References
- Industrial Cybersecurity - Siemens Global
- CERT Services - Siemens Global
- Industrial Training - SITRAIN - Siemens Global
- SIOS
- SIOS
- SIOS
- Contact Database - Siemens AG
- CERT Services - Siemens Global
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>