ELKAY EMABFTL, LMABFTL Wall Mount Water Coolers Installation Guide

July 26, 2024
ELKAY

ELKAY EMABFTL, LMABFTL Wall Mount Water Coolers

Specifications

  • Model Numbers: EMABFDTLD, EMABFDTLRD, EMABFTLDDD, EMABFTLRDDD, EMABFTL81E, EMABFTLR81E, LMABFDTLD, LMABFTLDDD, LMABFTL8*1E
  • Product Type : Wall Mount Water Coolers
  • Patent: Zurn-elkay.com/patents

Product Usage Instructions

Installation:

  1. Refer to the provided manual for detailed installation instructions.
  2. Ensure the water cooler is securely mounted on the wall using the hanger brackets.
  3. Connect the water supply following ADA requirements.

Usage:

  1. Locate the push bar mechanism as shown in Fig. 6 of the manual.
  2. Push the bar to dispense water from the cooler.
  3. Ensure proper maintenance and cleaning of the water cooler for optimal performance.

WARNING : Cancer and Reproductive Harm – www.P65Warnings.ca.gov

Note : Danger! Electric shock hazard. Disconnect power before servicing the unit.

Uses HFC-134A refrigerant

NOTE : Non-refrigerated units do not include all electrical and refrigeration components shown above. Other components and rough-in are the same as shown.

EMABFTL8

*ADA REQUIREMENT

LEGEND

  1. RECOMMENDED WATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8 O.D. UNPLATED COPPER TUBE. POSICION DE ABASTECIMIENTO DE AGUA RECOMENDADA. VALVULA CERRADA (NO AMUEBLADO) PARA ACEPTAR 3/8″ O.D. TUBO DE COBRE NO PLATEADO.
  2. RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4″ O.D. DRAIN
  3. 1-1/4 TRAP NOT FURNISHED**
  4. ELECTRICAL SUPPLY (3) WIRE RECESSED BOX
  5. INSURE PROPER VENTILATION BY MAINTAINING 6″ (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.

LEGEND

  1. RECOMMENDED WATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8 O.D. UNPLATED COPPER TUBE.
  2. RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4″ O.D. DRAIN
  3. 1-1/4 TRAP NOT FURNISHED**
  4. ELECTRICAL SUPPLY (3) WIRE RECESSED BOX
  5. INSURE PROPER VENTILATION BY MAINTAINING 6″ (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
  6. 7/16 BOLT HOLES FOR FASTENING THE UNIT TO WALL

IMPORTANT
ALL SERVICES ARE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON HANGER BRACKETS & TRAP

INSTALLATION

  1. Remove the hanger bracket fastened to back of the cooler by removing one 1) screw.
  2. Mount the hanger bracket and trap as shown in Figure 2.
    • NOTE : Hanger Bracket MUST be supported securely. Add a fixture support carrier if wall will not provide adequate support.
    • IMPORTANT :
    • 4 3/4 in. (121mm) dimension from wall to center- line of trap must be maintained for proper fit.
    • Anchor hanger securely to wall using all five (5) 5/16″ dia. mounting holes.
  3. Install straight valve for 3/8″ O.D. tube.

INSTALLATION OF COOLER

  1. Hang the cooler on the hanger bracket. Be certain the hanger bracket is engaged properly in the slots on the cooler back as shown in Fig. 4.
  2. Loosen the two (2) screws holding the lower front panel at the bottom of the cooler base and two (2) screws at the top. Remove the front panel and set aside.
  3. Connect water inlet line Note 4 of General Instructions.
  4. Remove the slip nut and gasket from the trap and install them on the cooler waste line making sure that the end of the waste line fits into the trap. Assemble the slip nut and gasket to the trap and tighten securely.

STARTUP

Also, See General Instructions

  1. Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, adjust the screw, accessible by removing front push panel (Item 7, Fig. 6). CW adjustment will raise stream and CCW adjustment will lower the stream. For best adjustment, the stream should hit the basin approximately 6-1/2″ (165mm) from the bubbler.
  2. Replace the front panel and secure by retightening four (4) screws.
  3. If a taste, odor or sediment problem is prevalent, try installing our water filter module.

PUSH BAR MECHANISM

Water Valve Mechanism – ADJUSTMENT PROCEDURE:

  • Turn the adjustment screw (Item 19) “Counter-Clockwise” until the water flow from the bubbler starts.
  • Turn the adjustment screw “Clockwise” until water flow stops, THEN turn an additional 1/2 turn.

NOTE:

  • Adjustments stated above are viewed from underneath unit (bottom side of dispenser panel Item 1)
  • If continuous flow occurs at the end of the compressor cycle, turn the cold control (Item 25) counterclockwise 1/4 turn.

LEGEND

  1. Note : Water flow direction
  2. Adjust this screw to eliminate mechanism “Free Play” or continuous flow from bubbler conditions. (See ADJUSTMENT PROCEDURE)
  3. Stream height adjustment (see note #8)

COLOR TABLE

PARTS LIST

ITEM NO PART NO DESCRIPTION
1 22897C Panel – Bottom Dispenser
2 98537C Kit – Blocks/Bumpers/Rivets
3 0000000872 Kit – Push Bars/Nuts
4 98789C Kit – Front & Side Push Bar Brackets/
    Screws
5 See Color Tbl Panel – Right Side
6 See Color Tbl Panel – Left Side
7 See Color Tbl Panel – Front Push
8 1000001602 Kit – Elbow – 5/16″x1/4″ (3 Pack)
9 98856C Kit – Drain/Plug/Strainer/Elbow/Gasket/
    Nut
10 98777C Kit- Compr Mtg Hdwe/Grommets/Clips/
    Studs
11 70864C Screw – #8 x 5/8” Lg. Torx/Slot
*12 36322C Compressor Serv. Pak 115V
13 0000000238 Kit – Elect/Relay/Overload/Cover
14 98531C Kit – Regulator/Holder/Nut
15 23003C Bracket – Regulator Mounting
16 See Color Tbl Panel – Right Rear
17 See Color Tbl Panel – Left Rear
18 See Color Tbl Panel – Front Lower (Not Shown)
19 70935C Screw – Shoulder x 1/2″ Lg.
20 45929C Tube – Drain
21 36208C Power Cord
22 98775C Kit – Fan Motor Assy/Blade/Mtr/Shroud/
    Screws/Nut
23 98778C Kit – Heat Exchanger/Drier
24 98917C Basin Replacement – Stainless Steel
    (with Drain Tube)
25 98773C Kit – Cold Control/Screws
26 98724C Evaporator Replacement Assembly
27 56092C Tubing – Poly (Cut To Length)
28 98899C Kit – Hardware/Screws/Clips
29 55996C Strainer (See “General Instructions”)
30 96453C Kit – Bubbler Replacement
31 97446C Vandal-Resistant Bubbler Assembly
32 55931C Cover-Dispenser Bottom
33 98776C Kit – Condenser/Drier
34 66703C Drier
35 See Color Tbl Panel – Right Rear TL
36 See Color Tbl Panel – Right Rear TLR
37 See Color Tbl Panel – Left Rear TL
38 See Color Tbl Panel – Left Rear TLR
39 1000004447 Kit – Drain Tube Assy
40 1000001994 Kit – Tee 1/4″ (3 Pack)
NS 28551C Hanger Bracket (Not Shown)

*REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE : All correspondence pertaining to any of the above water coolers or orders for repair parts MUST include Model No. and Serial No. of cooler, name and part number of replacement part.

PRINTED IN U.S.A.

FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816

REPAIR SERVICE INFORMATION TOLL-FREE NUMBER 1.800.260.6640

ELKAY MANUFACTURING COMPANY • 1333 BUTTERFIELD ROAD • DOWNERS GROVE, IL 60515 • 630.574.8484 • www.elkay.com

Q: What should I do if the water cooler is not dispensing water?
A: Check if the water supply is connected correctly and if there are any blockages in the system. Refer to the troubleshooting section of the manual for further assistance.

Q: How often should I clean the water cooler?
A: It is recommended to clean the water cooler at least once a month to prevent any buildup of contaminants and ensure hygienic water dispensing.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

ELKAY User Manuals

Related Manuals