General information

JAMARA e.K. is not liable for any damage caused to the product itself or through this, provided this is due to improper operation or handling errors. The Customer alone bears the full responsibility for the proper use and handling, including without limitation, the assembly, the charging process, the use and choice of the operation area. Please refer to the operating and user instructions, it contains important information and warnings.

Certificate of Conformity
Hereby JAMARA e.K. declares that the product „Charger X-Peak 80 BAL V2, No. 153059“ complies with Directive 2014/30/EU, 2014/35/EU and 2011/65/EU.
The full text of the EU Declaration of Conformity is available at the following Internet address: www.jamara-shop.com/Conformity

Read the complete instructions and security instructions carefully before using the model.
Caution! Please fully and carefully read warnings/ safety instructions. These are for our own security and can avoid accidents/injuries.

Technical data:

Input| AC 100 – 240 V; 50 Hz; 0,84 – 0,35 A; 84 W
DC 11 – 18,0 V; 5 – 7,2 – 4,55 A; 80 W
---|---
Output| LiIon/LiPo/LiFePo: 1 – 6
NiCd/NiMH: 1 – 15
Pb 2V ~ 20 V
Charging current| max. 80 W, 0,1 ~ 6,0 A
Discharge current| max. 10 W, 0,1 ~ 2,0 A
Balance current| 300 mAh/cell
Dimensions| 136 x 113 x 63 mm
Weight| 639 g

Highlights:

  • Dual Power Built-in AC Adapter 230V and 11 – 18V
  • Internal independent lithium battery balancer
  • Individually balanced battery discharge
  • Fast and storage model for various type of battery
  • Maximum safety
  • Automatic charging current limit
  • Input power monitoring
  • Capacity limit
  • Proscessing time limit
  • Load capacity display
  • Supports Lithium, NiMh, NiCd and Lead battery packs
  • 5 memory locations
  • Active fan

Box content:

  • Charger
  • Charging lead: BEC, Tamiya, LiPo high-current plug, Crocodile clips, Balancer board 12 V for power supply, Supply cable, Power cable
  • Instructions

Special features

Internal independent lithium battery balancer
The Charger has an integrated balancer connection for the included Balander board (up to 6-cell lithium). It isn‘t necessary to connect an external balancer for balance charging.
Balancing individual cells battery charging/discharging
During the process of discharging, the charger can monitor and balance each cell of the battery individually. Error message will be indicated and the process will be ended automatically if the voltage of any single one cell is abnormal.
Adaptable to various type of lithium battery
Charger is adaptable to various types of Lithium batteries, such as Li-ion, LiPo and LiFe series of batteries.
Fast and storage mode of lithium battery
Purposes to charge different battery types, „fast“ charge reduce the duration of charging, whereas „store“ state can control the final voltage of your battery, so as to store fo a long time and protect useful time of the battery.
Maximum safety
Delta-peak sensitivity: the automatic charge termination program based on the principle of the Deltapeak voltage detection.
When the battery‘s voltage exceeds the threshold, the process will be terminated automatically.
Automatic charging current limit
You can set up the upper limit of the charging current when charging your NiCd or NiMh battery. It is useful for the NiMh battery of low impendance and capacity in the „Auto“ charging mode.
Capacity limit
The charging capacity is always calculated as the charging current multiplied by time. If the charging capacity exceeds the limit, the process will be terminated automatically when you set the maximum value.
**Temperatur monitoring with programmable cut-off ***
The battery‘s internal chemical reaction will cause the temperature of the battery to rise. If the temperature limit is reached, the process will be terminated.

  • This function is available by connecting optional temperatur probe (Ord. No. 153057), which is not included in our package.
    Processing time limit
    You can also limit the maximum process time to avoid any possible defect.
    Input power monitoring
    To portect the car battery used as DC input power from being damaged, its voltage keeps being monitored. If it drops below the lower limit, the process will be ended automatically.
    Data store/load
    The maximum five batteries‘ data can be stored for users‘ convenience. You can keep the data pertaining to program setting of the battery of continuous charging or discharging. Users can call out these data at any time without any special program setting.
    Cyclic charging / discharging
    1 to 5 cyclic and continuous process of charge>discharge or discharge>charge is operable for battery refreshing and Balancing to simulate the battery‘s activity.
    Connections and Controls

    1. 230 V AC Input
    2. 11 – 18 V DC Input
    3. Temperature sensor socket (sensor not included)
    4. Output charge lead – red = plus (+) | black = minus (-)
    5. Balancer lead sockets (1 – 6)
    6. LED screen
    7. Batt. Type = Scroll through the Main Menu Stop any charge processes
    8. Status = After values See the status of individual cells in balance charge mode
    9. Start / Enter button = Resume or start charge processes. Confirm an action.

Using your charger for the first time
The X-Peak 80 BAL V2 is fitted with 2 power inputs which gives you the choice of powering the unit from the household mains supply (220 V AC) or via 12 V DC. The 12 V DC can be either a vehicle battery or a stabilised transformer (11 – 18V).
Connect the charger to an input of your choice, if using 12 V pay particular attention to the polarity.
The red crocodile clip must be connected to the plus pole (+) and the black clip to the minus pole (-).
After connection the charger will display „Charge Discharge“ whilst a self test is conducted. If an error is encountered, for example if the input voltage is outside the allowed range of 11-15 V, a message will be displayed and the buzzer will sound. Disconnect the power supply and rectify the fault.

Important notes!

  • Never connect both power inputs simultaneously as this will destroy the charger!

  • Make sure to use the correct charging programme (Lithium, NiMh, Lead etc.) for the respective battery! Attempting to charge a battery with a non-compatible charging programme can cause serious damage to the battery and charger. There is a risk of fire
    or explosion! If you are not sure which charging programme to use for your battery, please contact the manufacturer of the battery or contact our customer service.

  • The charger is capable of unbalanced charging of multi-cell lithium batteries under controlled conditions when the appropriate charging programme is selected. Unbalanced charging of multi-cell lithium batteries is at your own risk. We strongly advise  against this and recommend that multi-cell lithium batteries are always charged balanced. Unbalanced charging can lead to cell voltage drift which can cause the battery to age more quickly and in the worst case can severely damage the battery. There is a risk of fire or explosion!

Battery packs to be charged or discharged are attached to the charger via 2 colour coded banana sockets using a good quality charging cable. Make sure that the plus (+) pole of the battery is connected to the red socket on the charger and that the minus (-) pole
of the battery is connected to the black socket of the charger.
When charging or discharging Lithium packs, always use the balancer function of the charger. This will not only provide protection for your cells, but also ensure maximum efficiency and long life.
To do so, you must connect both the charging cable and the balancer plug/socket. Not doing this will result in the individual cells not being protected and you will not be able to monitor the individual cell voltage in the display.

Having connected the charger to a power supply, the last settings used will be displayed. If you are going to charge/discharge the same pack, no settings need to be changed. The last used mode will be displayed.
If a different pack is to be charged/discharged the setting must be changed, starting with the battery type. To do this, press the ‘Batt.Typ/Stop’ button until the correct battery type flashes in the display.
This menu option is an endless loop.
The displayed battery type is confirmed by pressing the ‚Start/Enter‘ button. If you wish, each key press is confirmed by a brief acoustic signal.
Pressing the ’Start/Enter’ button allows the user to access the various parameters which can be changed, for example the charging current. The ’Status ’ buttons are used to change the values.
Once a battery pack has been connected, the selected operation can be started by pressing the ’Start/Enter’ button for 3 seconds. Providing that the battery is not damaged and correctly connected, the selected
operation will begin. If a problem is encountered, a warning bleep will sound and a warning message displayed. When operationing the charger will display the relevant information.
The following program flow chart shows the complete menu structure of the X-Peak 80 BAL V2:

Warning
As default this charger will be set to typical user settings when it is connected to a 12 V battery for the first time. The screen displays the following information in sequence and the user can change the parameter on each screen.
If you need to alter the parameter value in the program, press „Start/Enter“ key to make it blink then change the value with „ Status -“ or „Status + “ key. The value will be stored by pressing „Start/Enter“ key once

Specification of the parameters

The screen shows the nominal voltage of Lithium battery.There are three kinds of Lithium battery:
LiFe = 3,3 V; LiIo = 3,6 V; LiPo = 3,7 V
This is very important so you have to check the battery carefully and set it up correctly. If it is different from correct value the battery can explode during charge process.

To avoid from erroneous setting by users. The X-Peak 80 BAL V2 detects the cell count of Lithium battery automatically at the beginning of charge or discharge process. But deeply discharged battery can be perceived incorrectly. To avoid this error, the time can bye set to verify the cell count by the processor. Normally, 15 seconds are enough to detect the cell count correctly. You need to extend the time term limit for the battery of large capacity. But the charge or discharge process can may come to an end within the time term because of the time limit decided by the wrong count if you set too long time limit for the battery of small capacity. This may cause fatal error. You have to extend the time term if the processor detect the cell count incorrctly at the beginning of charge or discharge process. Otherwise, default value is recommended to use.
This shows the trigger voltage for automatic charge termination of NiMH and NiCd battery. The valid value ranges from 5 to 20 mV per cell. Setting the trigger voltage higher brings a danger of overcharging; whereas setting it lower brings a possibility of premature termination. Please refer to the techincal specification of the battery. (NiCd default: 12 mV, NiMH default: 7 mV).

On the left side of the charger is a 3-pin port used as a connection for a temperature sensor (not included). If the screen displays temperature, you can use the optional temperature probe to connect to the surface of the battery. The USB function is not available for this charger.
The maximum temperature of the battery can be set during the charge process. The process will be terminated automatically to protect battery once the temperature of battery reaches this values.
This feature is accomplished through temperature probe (optional, not supplied).

Attention!
Plug the temperature sensor cable (not supplied) only as shown. Plug the cable not reverse polarity. Your charger or the temperature sensor can be damaged.
The battery become warm after cyclec of charge/discharge process. The program will insert a time delay after each charge/discharge process to allow the battery enough time to cool down before beginning next cyle of charge/ discharge process. The valid value ranges from 1 to 60 minutes.

When the charge process starts, the integral safety timer starts to run simultaneously. If error detected or the termination circuit can not detect whether the battery is fully charged or not, this unit is programmed to prevent overcharging. Please refer to the below  statement to calculate the timer you set.
This program provides maximum capacity protection function. If the Delta peak voltage can not be detected or the saftey timer times out, the charge process will stopp automatically, when the battery reaches the user-set maximum charge capacity.
The beep to confirm userts operation sounds every time a button is pressed.
The beep or melody sounds at various times during operation to confirm different mode change.
These functions can be switched on or off.
This funktion monitors the voltage of the input battery used to power this charger.
If the voltage is lower than user-set value, the program will end forcibly to protect the input battery.

Safety Timer Calculations
When charging NiCd or NiMH batteries, divide the battery‘s rated capacity (mAh) by the charge current (A). And divide the result by 11.9.
For example:

  • 1.000 mAh Capacity / 1,2 A Current / Safety timer setting, divided by 11,9 = 70 minutes
  • 2.000 mAh Capacity / 2,0 A Current / Safety timer setting, divided by 11,9 = 84 minutes
  • 3.300 mAh Capacity / 3,3 A Current / Safety timer setting, divided by 11,9 = 92 minutes

Charging of lithium battery

The left side of the first line shows the type of battery you choose. The value on the left of the second line of the charger is current user set. After setting the current and voltage, press START/ENTER key for more than 3 seconds to start the process.(charge current: 0.1-5.0A,voltage:1-5V).
This displays the number of cells you set up and the processsor detects. „R“ shows the number of cells detected by the charger and “S“ is the number of cells set by you at the previous screen. If both numbers are identical you can start charging by press START/ENTER button. If not,press BATT TYPE/STOP button to go back to previous screen to carefully check the number of cells of the battery pack before going ahead.

This screen shows the real-time status during charge process.
Press BATT TYPE/STOP key once to stop the charge process.

  1. Number of cell
  2. Charging time
  3. Charging current
  4. Battery voltage
  5. Charged capacity

Charging Lithium battery in the Balance mode
This function is for balancing the voltage of Lithium-polymer battery cells while charging. In the balance mode, the battery needs to have a balance lead to connect to the individual port at the right side of the charger. And you need to connect the battery‘s output plug to the output of charger.
Charging in this mode is different from the normal modes, because the built-in processor monitors voltage of individual cell and control input current fed into each cell to normalize the voltage.

The value on the left side of the second lines sets the charge current. The value on the right side of the second lines sets the battery pack‘s voltage.After setting current and voltage, press START/ENTER for more than 3 seconds to start the process.
This displays the number of cells you set up and the processor detects. “R“ shows the number of cells detected by the charger and “S“ is the number of cells set by you at the previous screen. If both numbers are identical you can start charging by press START/ENTER button. If not, press BATT TYPE/STOP button to go back to previous screen to carefully check the number of cells of the battery pack before going ahead.

This screen shows the real-time status during charge process. Press BATT TYPE/STOP key once to stop the charge process.

  1. Number of cell
  2. Charging time
  3. Charging current
  4. Supplied capacity
  5. Current voltage battery

Individual cell connection diagram
The illustration opposite shows the configuration of the balancer connector. The charger is provided with a balancer port after Jamara connector system (XH). Your battery should be provided with a different norm, use suitable adapters from our range.

Fast charging of Lithium battery
Charging current will become lower when it progress to the end of charging.A specific CV process will be reduced to end the charging process earlier.In fact,the charging current will goes to 1/5 when the charging process comes to 1/10.Charging capacity will be a little smaller than normal charging,but charging time will be shortened accordingly.
You can set up the charging current and voltage of the battery pack Press START/ENTER key to display voltage confirmation.Then press START/ENTER key again to confirm and begin to charge.
This screen shows the real-time status of“fast charging“.Press BATT TYPE/STOP key once to stop the charge process

  1. Number of cell
  2. Elapsed time
  3. Charge current
  4. Supplied capacity
  5. Current voltage battery

Storage control of Lithium battery
This function is for charging/discharging batteries which are not used at once.
This program is designed for charging or discharging of batteries of specific original state.They are classified by types: 3.75 V LiIo, 3.85 V LiPo and 3.3 V LiFe. The program will begin to discharge if the original state of the battery exceeds the voltage level of storage.
At this screen,you can set up the current and voltage of the battery pack.
Charging and discharging will make the batteries come to the voltage level of“storage“state.
This screen shows the real-time status charging.Press BATT TYPE/STOP key once to stop the charge process.

  1. Number of cell
  2. Elapsed time
  3. Charge or discharge current
  4. Supplied capacity
  5. Current voltage battery

Discharging of Lithium battery
The value of discharge current on the left can not exceed 1C,and the value on the right can not be under the voltage recommended by the manufacturer to avoid deep discharging.Press START/ ENTER for more than 3 seconds to start charging.
This shows the real-time status of discharging,you can press BATT TYPE/STOP key to stop discharging.

  1. Number of cell
  2. Elapsed time
  3. Discharging current
  4. Battery voltage
  5. Discharged capacity

Voltage balancing and monitoring in the discharge process
The processor monitors voltage of each cell when the battery packs are during its “storage“ and „discharging“ process. To achieve this feature,plug each battery to the charger individually. If voltage of any cell is abnormal,B6 will show error message and terminate the program forcibly. So if there is battery damage or disconnection, you can see the error message and press Status to know which cell is damaged.
The processor detects voltage of one cell is too low. The 4th cell was damaged.
The value of voltage may be zero if disconnection occurs.

Charging of NiCd/NiMH battery
This program is for charging and discharging of NiCd/NiMH batteries associated with R/C models applications.You can press START/ENTER key to make it blink and then Status to change the parameter value.Press START/ENTER key to store the value.
This program charge the battery using the current you set up.In the „auto“state,you should set up the upper limit of the charge current to avoid damage by excessive feeding current.Some batteries of low resistance and capacity can lead to higher current in the“auto“charging mode. But in the manual mode,it will charge with the current you set. You can make it blink in the current field and press Status at the same time to switch mode.
The screen shows the real-time status. Press BATT TYPE/STOP key to end the program.The sound will emitted to indicates the end of program.

  1. Battery type
  2. Elapsed time
  3. Charge current
  4. Battery voltage
  5. Charged capacity

Discharge of NiCd/NiMH battery
Set charge current on the left and the final voltage on the right. Range of the charge current is 0.1-1.0A;range of final voltage is 0.1-25.0V. Press START/ ENTER key for more than 3 seconds to start the program.
The screen indicates the discharging state.You can press START/ENTER key to alter discharge current.Press START/ENTER again to store the value. Press BATT TYPE/STOP key to stop discharging. The emitted sound alerts the end of discharging

  1. Battery type
  2. Elapsed time
  3. Discharge current
  4. Battery voltage
  5. Discharged capacity

Charge/discharge and discharge/charge cycle of NiCd/NiMH battery
You can set up sequence on the left and the number of cycles on the right.
You can balance,refresh and bread-in the battery with this function.You can set a temporary cool-off procedure in the use‘s setting. Range of the cycle number is 1-5.
Press BATT TYPE/STOP key to stop program,you can press START/ ENTER key to alter charge current.The sound indicates the end of program.
When it approaches to the end,you can see the capacity of the battery being charged or discharged.You can press Status key to display result of each cycle.

  1. Number of cell
  2. Elapsed time
  3. Charge or discharge current
  4. Battery voltage
  5. Charge or discharge capacity

Charging of the Pb battery
This program is only suitable for charging Pb (lead-acid) battery with nominal voltage from 2 to 20 V. Pb (lead-acid) battery is completely different from NiCd/ NiMh battery. These batteries can only deliver current lower in comparison to their capacity. The same restriction applies to the charging process. Consequently, the optimum charge current can only be 1/10 of the capacity. Pb battery can not be used for fast-charging, please follow the instructions provided by the battery manufacturer.
You can press START/ENTER key to make it blink and alter the value of parameters using  Status , press START/ENTER key to store the value.
Set up the charge current on the left and nominal voltage on the right Range of current is 0.1 – 5.0 A, the voltage should match the battery being charged.
Press START/ENTER key for more than 3 seconds to start charging.
The screen displays the real-time discharging status.Press START/ ENTER key to alter discharge current.Press START/ENTER key again to store the parameter value you set.Press BATT TYPE/STOP key to end the program.

  1. Battery type
  2. Elapsed time
  3. Charge current
  4. Battery voltage
  5. Charged capacity

Discharging of the Pb battery
Set up the charge current on the left and nominal voltage on the right. Range of discharge current is 0.1-5.0A,the voltage should match the battery being charged. Press START/ENTER key for more than 3 seconds to start charging.
The screen displays the real-time discharging status.Press START/ ENTER key to alter discharge current.Press START/ENTER key again to store the parameter value you set.Press BATT TYPE/STOP key to end the program.

  1. Battery type
  2. Elapsed time
  3. Discharge current
  4. Battery voltage
  5. Discharged capacity

Data storage program
For your convenience, X-Peak 80 BAL V2 has a data storage and load program. It can store five battery data representing the respective specifications of batteries. You can call back the data when charging or discharging without setting up the program  again.Press START/ENTER key to make it blink, and use Status  to set up the parameter.

Data storage
Setting of the parameter in the screen will not affect the charge and discharge process. They just present the specification of the battery.
The example is NiMH battery pack,including 12 cells,the capacity is 3000mAh.

Set up the charge current in the manual mode,or current limit in the auto mode.
Press INC and DEC key simultaneously to make the current field blink to switch the charge mode.

  1. Voltage
  2. Data number
  3. Capacity
  4. Type of battery

Set up the discharge current and final Voltage.
Set up the charge/discharge sequence and cycle number.
Saving the data

Load data program
This program is to load the data stored at the“save data“program.Press START/ENTER key to make the data field blink and press INC or DEC for more than 3 seconds to load the data.
Choose the data number you want to call back.The data you want to call back will be displayed.
Loading the data.

Various information in the program
You can inquire variors information on the LCD screen during the charging and discharging process. Press DEC key, the charger will display user‘s setting. You can press INC key to monitor voltage of each cell while the battery is connected with each port of the charger:

It comes to the final voltage when the program ended.
Indication of the max. capacity preset in the presettings.
Display of the max. process time specified in the presettings
3-pin connector is selected to be the USB port.
For this charger the USB function is not available.
The external temperature is displayed when the temperature probe is used.
Present input voltage
Display of the single cell voltages of a lithium battery.
The battery is connected with each port through cable; you can check voltage of each cell in the battery pack. When the cable is connected with the ports on the right of the charger, the program will display voltage of up to 6 batteries.
The battery pack needs an output connector connected with each cell.

Warning and orror information
X-Peak 80 BAL V2 incorporates a variety of functions for the systems to verify processes and the state of the electronics. In case of an error the screen will display the cause of error and emit an audible sound.

Incorrect polarity connected.

Battery connection is interrupted.

Short-circuit of the output termination.

Erroneous selection of voltage of Lithium pack, please check the voltage of the battery pack.

The voltage of the battery pack has been selected incorrectly!

The charger has malfunctioned for some reason. Seek professional advice.

The voltage is lower than which is set. Please check the nubmer of cells in the battery pack.

The voltage is higher than which is set. Please check the number of cells in the battery pack.

Voltage of one cell in the battery pack is too low, please check the voltage of each cell.

Voltage of one cell in the battery pack is too high, please check the voltage of each cell.

Wrong connection of the connector detected; please check the connector and cable.

The internal temperature is too high, please cool down.

The processor cannot control the feeding current, please repair it.

All rights reserved. Copyright JAMARA e.K. 2024
Copying or reproduction in whole or part, only with the expressed permission of JAMARA e.K.

 Accessories

No. 332057
MPX
Charging lead Deluxe
No. 332058
LiPo
Deans Charging lead Deluxe

No. 332051
Tam charging lead with lead gold
No. 091114
BEC charging lead with banana plug

No. 332059
Charging lead XT60

Safety Information

  • Whenever you operate your charger the following safety instructions must be followed.
  • This device is not intended for use by individuals (including children) with reduced physical sensory, mental abilities, lack of experience and / or knowledge, unless they are supervised in how the device is to be used.
  • Children should be supervised to ensure that they do not play with the appliance.
  • Only for indoor use.
  • The charger may get hot in use, position the unit so that the heat can dissipate.
  • Never expose the charger to moisture or direct sun light.
  • After use always disconnect the unit from the mains and unplug any batteries.
  • Never leave the charger unattended when in use, and always operate it on a fire proof surface.
  • Avoid short circuits at all costs. Always observe the correct polarity.
  • Batteries should always be allowed to cool down before you charge or discharge them.
  • Only charge or discharge packs containing cells from the same manufacturer and of the same capacity.
  • Do not connect packs in parallel to charge or discharge them.
  • Always disconnect the pack from any electronic system (ESC etc.) before attempting to charge it.
  • Connect the charging cable to the charger first and then to the battery.
  • Never try to charge/discharge damaged packs or cells.
  • Follow the directions given by the battery manufacturer.
  • The charger may only be used to charge / discharge the types of cells listed in the technical specifications.
  • Do not open the unit. This will void the guarantee and may be dangerous. If the charger is damaged or faulty, return it our service department for repair.

Disposal restrictions
Electrical appliances must not be disposed of in domestic waste and must be disposed of separately.
You are obliged to take out the batteries, if possible, and to dispose of the electrical equipment at the communal collection points. Should personal data be stored on the electrical appliance you must remove them by yourself.

JAMARA e.K.
Am Lauerbühl 5 – DE-88317 Aichstetten
Tel. +49 (0) 75 65/94 12-0 – Fax +49 (0) 75 65/94 12-23
info@jamara.comwww.jamara.com
Service – Tel. +49 (0) 75 65/94 12-777
service@jamara.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals