Product Information

Specifications

  • Product Name: LIFT Master 8
  • Manual Language: English, Spanish
  • Operating   Conditions: Temperature, Humidity
  • Technical Parameters: Operating voltage, Power consumption

Product Usage Instructions

Safety Precautions

Before using the product, ensure you have read and understood all the instructions provided in the manual to prevent any physical injury or property damage.

Prohibition

Identify the symbols used in the manual to understand the level of danger associated with the product. Follow all safety and operation instructions before operating the controller.

Operating Instructions

After ensuring all safety precautions are met, follow these steps to operate the hoist.

  1. Open the main power switch and activate the urgent stop function.
  2. Set the general control knob to position 1.
  3. Check the upward and downward phase sequence of each hoist by following the specified methods.

Inspection and Maintenance

Do not expose the controller to wet environments. Perform regular inspections and maintenance to ensure proper functioning.

Frequently Asked Questions

Q: Can the product be used underwater?

A: The product is not suitable for underwater operations. Avoid long-term exposure to dampness, rain, or underwater conditions.

Q: What should be done after operating the hoist?

A: Make sure all switches are turned off after completing the operation to prevent any accidents or damage.

 The Markings

  • Please read and understand all contents of this manual before using this product, and then carry out installation, operation, or maintenance. Otherwise, it may lead to serious physical injury or casualties and property losses.

Definition of identification

  • The design of the HGK series controller is suitable to control the electric hoist. This manual uses the following symbols to identify the degree or level of danger.

Danger

  • It refers to a very dangerous and urgent dangerous state, which may lead to death or serious personal injury and serious property loss.

Warning

  • It refers to the warning of potentially dangerous conditions in the process of use, which may lead to serious physical injury, property loss, and death.

Attention

  • It refers to the potentially dangerous state. If it is unavoidable, it may cause slight or moderate personal injury and property damage.
  • According to the above situation, the “attention” prompt may also lead to serious injury or death.
  • Therefore, no matter what kind of prompt, the safety operation should be put in the first place, and the manual should be put in a convenient place for the operator to reference.

Prohibition

General Rules

  • Incorrect use or negligent maintenance of the controller may lead to dangerous conditions, such as derailment during operation.
  • Before installation, operation, or maintenance, carefully read and abide by the safety and operation instructions and all notes in this manual.
  • If the product relates to any other equipment and fails to reflect the performance of the product, our company will not be responsible for the failure and illegal operation.
  • If the product is used for non-design purposes, please contact your distributor or our company in advance to confirm.

Before operation

Attention

  • This manual is formulated for the operators of the controller. Before operation, the operators must fully understand all the safety and operation instructions in this manual.

After Operation

  • After the operation, make sure all the switches turned off.

Inspection and Maintenance

  • Do not put the controller in a wet environment.

Technical Information

  • Operating conditions and environment lot^+sot Temperature
  • Humidity: less than or equal to 1OO%RH, the product is not for underwater operations, and cannot be used for long-term dampness, rain, and underwater.
  • Material: No special material.

Parameters

Safe operation

Please ensure that the interior wiring sequence for the extension line of the hoist is consistent (keep the grounding wire unchanged, and the L1L2L3 color sequence consistent at the two ends of the line).

  1. Open the main power switch, and keep the status of urgent stop and pop-up.
  2. Turn the general control knob to “1”.
  3. Gradually check whether the upwards and downward phase sequence of each hoist is consistent respectively.

The methods are as follows:

  1. Turn the “Inch” and “Relay” knobs to “Inch”.
  2. Turn the No. 1 hoist rotary switch to “ ” (up), and then press the start button, and check whether the operation is normal.
  3. Check whether the upwards and downwards moving direction of all hoists is the same as per the same method gradually.
  4. Independently regulate a hoist as per the same method above.

For synchronous lifting, please ensure the consistency of the phase sequence of the hoists, with the method as follows:

  1. Up Turn the rotary switches of all hoists to “ ” (up), select “Inch” or Relay” and press the Start key (Inch requires pressing the Start key all the time and releasing the Start key to stop Inch; for Relay, press the Start key to enable the hoist to start to move and turn “Inch” and “Relay” rotary knobs to the middle positions to stop “Relay”) successively.
  2. Down: Turn the rotary switches of all hoists to “ ” (down), select “Inch”or “Relay” and select Stop at the designated position.
  3. Down: When the phase sequences of all hoists to go up are consistent, if the general rotary knob can be directly turned from “1” to “2”, long press the Start key under “Inch” mode and go down directly under “Relay” mode and select Stop at the designated position.
  4. When all hoists are displayed as Up, but move down, please inspect whether the phase sequence of the general incoming power line in the aviation plug is correct (only reverse any two of three live wires).
  5. If only one hoist moves in the direction opposite to others, the phase sequence of the extension wire of this hoist is incorrect. Please inspect and reverse the phase sequence.

Precautions

  • In case of emergencies, please press the emergency stop key.
  • After the hoisting operation completes, please turn all rotary switches to the middle, and shut down the main power switch.
  • Before use, please read the instruction manual carefully, and carry out hoist operation after adjustment, to avoid danger.

Warranty

5 Warranty One year

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals