DJPower WP-2 Bubble Fogger User Manual
- June 10, 2024
- DJPOWER
Table of Contents
WP-2 Bubble Fogger
User Manual Bubble Fogger WP-2
USER MANUAL
**** Safety Instructions
- This device is only for use in closed rooms (not outdoors).
- The warranty claim expires if the device is modified by the user.
- The device may only be repaired by trained specialists.
- Only use fuses of the same type and only original parts as spare parts.
- To prevent fire and electric shock, protect the device from rain and moisture..
1.1. Hinweise für den sicheren und einwandfreien Gebrauch
Beware of heat and extreme temperatures!
Do not place the device in a location subject to extreme temperatures. Only
operate the device in an ambient temperature between 0°C (32°F) – 40°C
(104°F). Do not expose the device to direct sunlight or heat sources.
Protect the device from moisture, water and dust!
When setting up the device, avoid locations with high humidity or excessive
dust. Do not place liquids on or near the system.
Always place the device on solid ground!
Place the device on a solid surface to avoid vibrations.
Do not use chemical agents for cleaning!
Use a clean, dry cloth to remove dust. Metal parts can be cleaned with a
slightly damp cloth. Before cleaning the device, always pull out the mains
plug!
If the device does not work properly!
If problems arise, unplug the power cord. The user should not attempt to
service the device on his own. All repairs and service must be performed by a
qualified technician.
Be careful with the power cord!
Never pull the mains cable to disconnect the device from the power supply, but
hold the plug housing in your hand. If you do not use the device for a long
period of time, pull out the mains plug
CAUTION!
The warranty claim expires in the event of damage caused by nonobservance of
the instructions. The manufacturer and importer assumes no liability
whatsoever for consequential damage. Only qualified specialists may establish
the correct electrical connection. All electrical and mechanical connections
must be installed in accordance with European safety standards
1.1. Intended use of the device
This device is a device that was developed for professional use on stages, in
discotheques, theatres, etc. The device is only approved for connection to a
maximum of 230V, 50/60 Hz AC voltage and is only intended for indoor use.
Regular breaks in use increase the service life of your device.
Avoid physical shock or any form of violence when installing or starting up
the device.
Make sure that cables are not lying around freely. This would endanger your
own safety and the safety of third parties.
The device must not be operated or stored in an environment in which splashing
water, rain or moisture is to be expected. Moisture or high humidity can
reduce the insulation of the device and lead to fatal electric shocks.
When using fog machines, it must be ensured that the fog saturation of the
room must allow a good visibility of at least 10 m.
Do not operate the device during thunderstorms. Overvoltage could destroy the
device. In the event of a thunderstorm, completely disconnect the device from
the mains by pulling out the mains plug.
Surrounding objects or surfaces must not be touched by the housing.
Make sure that when assembling and dismantling the device, the area below the
assembly site is cordoned off. This also applies to the performance of service
work.
Familiarize yourself with the functions of the device before putting it into
operation. Do not allow the device to be operated by persons who have no
experience in it. The most common cause of malfunctions is improper operation
of the device.
Keep the device away from children and never operate it unsupervised.
Never aim the nozzle at people and keep 50cm away from the nozzle.
ATTENTION! The emitted mist is very hot.
Keep a minimum distance of 50cm to other objects.
Use only the recommended high quality water-based fluid from your dealer.
Other fluids can cause damage. Do not use flammable additives such as oil,
gas, perfumes, etc. in your fluid.
Never point the nozzle at an open flame or flammable objects.
Make sure to fill up the fluid in time. Running the machine without fluid can
damage the pump and heater block. Unplug the power cord when topping up the
fluid.
Never drink the fog fluid. If it did happen, contact a doctor immediately. If
the fluid comes into contact with the eyes and mucous membranes, rinse the
areas immediately with water.
Only operate the device in a horizontal position.
Never use solvents or aggressive cleaning agents to clean the device.
Instead, use a soft, slightly damp cloth.
When transporting the device, please use the original packaging or the
accessories provided to prevent transport damage.
Unauthorized changes to the device are prohibited for safety reasons!
1.2. Any use of the device that deviates from the use described in these
operating instructions can lead to damage to the device. In this case,
the warranty claim expires. In addition, it should be noted that any other use
is associated with dangers and can lead to short circuits, fire, electric
shock and falls, for example.
Overhead mounting
Risk of death!
During installation, the provisions of BGV C1 (formerly VBG 70) and EN
60598-2-17 must be observed! The installation is to be carried out exclusively
by authorized specialist personnel.
The suspension devices of the device must be constructed and dimensioned in
such a way that they can carry ten times the payload for one hour without
causing permanent damaging deformation.
The installation must always be carried out with the help of a second,
independent suspension. This can, for example, be a suitable safety net. The
secondary suspension must be designed and installed in such a way that in the
event of a failure of the main suspension, no part of the installation can
fall.
During assembly, conversion and dismantling, staying unnecessarily in the area
of movement areas, on lighting bridges, under high workplaces or in other
hazardous areas is prohibited.
The commercial user has the following responsibilities for safety-related and
mechanical equipment:
- Check by an expert before the first start-up or after decisive changes before the start-up again.
- Review in the scope of the acceptance test at least every four years by an expert.
- Inspection by an expert at least once a year
How to proceed with overhead attachment:
Ideally, the device should be installed outside of the area where people are.
IMPORTANT! A high level of experience is required for overhead mounting.
This includes knowledge of working load calculations, knowledge of the
installation material used and knowledge of safety inspections of the material
used and the equipment, but the experience required is not limited to this
alone. Under no circumstances should you attempt the installation yourself
unless you are suitably qualified. Instead, hire a professional installer.
Please note that improper installation may result in personal injury and/or
property damage.
The device must not be installed within the reach of persons.
If the device is to be suspended from the ceiling or from high supports, work
must be carried out with truss systems. The device must never be installed in
such a way that it can swing freely in space.
Please note: Devices can cause serious injuries if they fall! If you have
doubts about the safety of a possible form of installation, then do NOT
install the device!
Before mounting the device, ensure that the mounting surface is capable of
supporting at least ten times the point load of the device’s own weight. Mount
the device with the mounting bracket on a truss system using suitable lifting
gear.
When installing overhead, ensure that the device is always secured with a
safety rope that can carry twelve times the weight of the device. Only safety
arrester ropes with screw links are to be used. Hang the safety catch rope in
the catch rope hole in the mounting bracket or on the device. Route the rope
over the truss or other secure attachment point. Hook the end into the screw
link and tighten the locking nut securely.
The maximum fall distance of 20 cm must not be exceeded!
A safety arrester rope that has been subjected to the stress of a fall or that
has been damaged must no longer be used as a safety arrester rope. Adjust the
angle of inclination using the mounting bracket and tighten the locking
screws.
Connection
2.1.1. Electrical Connection
Connect the device to the mains using the supplied power cable! The protective
earth must always be connected!
Cable (EU) | Cable (US) | Pin | International |
---|---|---|---|
Brown | Black | Live | L |
Blue | White | Neutral | N |
Green/ Yellow | Green | Earth | **** |
2.1.2. DMX connection
Make sure you always use shielded cables. 3pin or 5pin XLR cables are suitable
for this.
2.1.3. DMX connection with terminator
For installations where the DMX signal has to bridge a large distance or where
the device is to be operated in an environment with increased electromagnetic
radiation, such as a discotheque, we recommend using a DMX terminator. This
prevents the digital control signal from being corrupted by electrical noise.
The DMX terminator is simply an XLR connector with a 120Ω resistor between
pins 2 and 3, which is then plugged into the XLR output jack of the last
fixture in the chain.
Introduction
Thank you for purchasing the Bubble Fog Machine WP-2.
We recommend reading this user manual before using the device. Please follow
the instructions in this user manual. This is the only way to ensure safe
operation, proper use and a long service life for the device.
The Bubble Fog WP-2 is an effect machine with patented DJ Power technology,
which can create fog-filled soap bubbles. The WP-2 is designed in such a way
that unused soap bubble fluid is returned to the appropriate tank and
therefore cannot drip onto the floor.
DJ Power’s WP-2 is suitable for larger stages, halls or bars.
3.1. Features
- Jet design, produces many bubbles with mist.
- Efficient heating system for even fog output
- Separate mist and bubble tanks.
- Unused bubble fluid is returned to the tank.
- Integrated LED bar with 6x8W RGBY/ 15° beam angle
- 1.3 liter bubble fluid/ 1.3 liter hazer fluid tank (lasts approx. 90 minutes at maximum output)
- Operation via DMX, remote control or manual
- Built-in control LCD
- Please only use DJPower fog and bubble fluids.
3.2. Lieferumfang
– 1x WP-2
– 1x power cable
– 1x W-2 wireless controller
– 1x Quicklock hook
– Operation manual
3.3. Product description
First time setup
ATTENTION!
Before using the device for the first time, remove all packaging materials.
- After checking that the device is intact and complete, please place it on a flat surface.
- Fill the tanks with fluid! Please only use the recommended fluids, otherwise the device may be damaged and the guarantee will be void.
- Make sure that there is always enough fluid in the tanks.
- Connect the device to the mains.
- The device starts to heat up. This process takes about 3 minutes, during which time “Warming up” is shown on the display.
- The heating process is complete. “Ready TO Work” appears on the display.
4.1. Control
It is operated via the display, the remote control or via DMX.
MENU | Calling up the menu structure to make individual settings. |
---|---|
UP / TIMER | Select a menu item or increase a value. |
Activate the timer.
DOWN /VOLUME| Select a menu item or decrease a value. Start manual ejection.
ENTER / STOP| Confirm the selection or the setting made. Stop manual ejection.
4.1.1. Menu
Menü| Value|
Function
---|---|---
**Interval Set| 5 – 200s| Here you can set the interval for the timer
function.
****Duration Set| ** 5 – 200s| Here you can set the ejection duration
for the timer function.
**Timer Out| ** 1 – 100%| Here you can set the output quantity for
the timer function.
**Volume Out| ** 1 – 100%| Here you can set the output quantity
for manual fog output.
DMX512 ADD| **** 1 – 512| Setting the DMX address.
4.1.2. DMX Table
If the device is controlled with a DMX signal, the display shows the set DMX
address.
Kanal | Value | Range | Function | |
---|---|---|---|---|
1 | Bubble Output | 0 | 10 | No function |
11 | 255 | Bubble ON | ||
2 | Nebel Output | 0 | 10 | No function |
11 | 255 | Fog ON | ||
3 | Fan Output | 0 | 10 | No function |
11 | 255 | Fan ON | ||
4 | Clean Up (selfclean) | 0 | 10 | No function |
11 | 255 | Cleaning ON | ||
5 | LED Dimmer | 0 | 10 | No function |
11 | 255 | dimmer function | ||
6 | LED RED | 0 | 10 | LED OFF |
--- | --- | --- | --- | --- |
11 | 255 | dimmer function | ||
7 | LED GREEN | 0 | 10 | LED OFF |
11 | 255 | dimmer function | ||
8 | LED BLUE | 0 | 10 | LED OFF |
11 | 255 | dimmer function | ||
9 | LED AMBER | 0 | 10 | LED OFF |
11 | 255 | dimmer function | ||
10 | LED MIXING COLOR | 0 | 10 | LED OFF |
11 | 255 | dimmer function | ||
11 | LED STROBE | 0 | 10 | STROBE OFF |
11 | 255 | Strobe Speed |
Technical data
Tension | AC 220V-240V; 50/60Hz |
---|---|
Power consumption max. | 650W |
Fuse | 5A/250V |
Warm-up time | About 3 minutes |
LEDs | 6x 8W RGBA/ 15° beam angle |
Tank volume | 1.3 liters (bubble tank) |
1.3 liters (Haze Tank)
Output volume| 128 m³/min
Max Ejection Height| 4m
Max Eject Distance| 3.5m
Hazer fluid consumption| Approx. 1L/h
Bubble fluid consumption| Approx. 1.3L/h
Required fluid| PRO-P(118050) + PRO-C (119308)
DMX 512| Yes
Number of DMX channels| 12
Remote control| Yes
Current in| P con
XLR in/out| 3-pin/5-pin
Weight net| 14.5kg
Weight gross| 17kg
Dimensions| 426x317x394mm
Dimensions packaging| 535x435x500mm
5.1. Cleaning and maintenance
To avoid clogging of the machine, the machine should be cleaned after 40 hours
of use.
For this purpose, 35% vinegar is mixed with 65% distilled water and the
machine is triggered 10-15 times.
The cleaning process should be done as follows:
- Disconnect the machine from the power supply
- Empty the tank with the bubble fluid
- Pour the vinegar and distilled water mixture into the Bubble Fluid Tank
- Connect the machine to the electricity
- Install the machine in a well-ventilated place
- Let the machine run for 5-10 minutes and make sure that the pump does not run dry
- Remove dust and fluid residue from the ventilation to prevent the machine from overheating
- Clean the machine housing with a damp cloth
- The machine should be used at least once a month
Importer:
B&K LUMITEC
2 rue Alfred Kastler
Zone Industrielle
67850 Herrlisheim – France
+33 (0) 3.88.96.80.90
+33 (0) 3.88.96.48.46
hello@bklumitec.com
www.bklumitec.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>