ELKAY LZSTL8WSSP-PF Bottle Filling Station and Versatile Bi Level ADA Cooler Installation Guide
- July 26, 2024
- ELKAY
Table of Contents
- ELKAY LZSTL8WSSP-PF Bottle Filling Station and Versatile Bi Level ADA
- STANDARD ROUGH-IN FOR LEFT-HAND HIGH, BOTTLE FILLER LOW MODELS
- ALTERNATE ROUGH-IN FOR RIGHT-HAND HIGH, BOTTLE FILLER LOW MODELS –
- ALTERNATE ROUGH-IN FOR LEFT-HAND LOW, BOTTLE FILLER HIGH MODELS
- ALTERNATE ROUGH-IN FOR RIGHT-HAND LOW, BOTTLE FILLER HIGH MODELS –
- INSTRUCTIONS FOR REMOVING WRAPPER
- HANGER BRACKETS INSTALLATION
- FINAL INSTALLATION (FILTER)
- INSTRUCTIONS FOR REPLACING FILTERS
- INSTRUCTIONS TO ACCESS PROGRAMMING BUTTON
- CONFIGURATION INSTRUCTIONS
- Enhanced EZH2O Error Codes
- PLUMBING DIAGRAMS VERSATILE BI-LEVEL
- Versatile Wrapper and Trim Kit Installation Instructions
- Versatile Wrapper and Trim Kit Installation Instructions continued. . .
- 115V Refrigerated Wiring Diagram with Alpha/Numeric Display
- Service Instructions
- Programming Instruction
- Pictured is unit only without bottle filler.
- FCC COMPLIANCE STATEMENT
- INDUSTRY CANADA STATEMENT
- Frequently Asked Questions (FAQ)
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ELKAY LZSTL8WSSP-PF Bottle Filling Station and Versatile Bi Level ADA
Cooler
INSTALLATION & USE MANUAL
LZ ™ Series Bottle Filling Stations & Coolers
*Versatile cooler design allows units to be installed either left-hand high and right-hand low or left-low and right high.
Basin change may be required. See desired rough-in to help determine if the
basin change is necessary.
Important: The refrigerated coolers must be hung on the right side.
WARNING: Cancer and Reproductive Harm –
www.P65Warnings.ca.gov
STANDARD ROUGH-IN FOR LEFT-HAND HIGH, BOTTLE FILLER LOW MODELS
ALTERNATE ROUGH-IN FOR RIGHT-HAND HIGH, BOTTLE FILLER LOW MODELS –
REQUIRES BASIN ASSY CHANGE
ALTERNATE ROUGH-IN FOR LEFT-HAND LOW, BOTTLE FILLER HIGH MODELS
ALTERNATE ROUGH-IN FOR RIGHT-HAND LOW, BOTTLE FILLER HIGH MODELS –
REQUIRES BASIN ASSY CHANGE
INSTRUCTIONS FOR REMOVING WRAPPER
CAUTION: WRAPPER DROPS AND SWINGS WHEN SECURITY SCREWS ARE REMOVED.
CAUTION: DO NOT LEAN ON WRAPPER.
CAUTION: DO NOT USE POWER TOOL TO TIGHTEN. DO NOT OVERTIGHTEN.
NOTE:
1. Ensure that there are no plumbing or external objects below the wrapper in
the specified dimension.
The specified (3.27’’) minimum distance is required for the wrapper to swing
out (see Fig D(iv)).
2. Removing the wrapper from the pivoting bracket when servicing the unit is
recommended. The wrapper may be left in place for quick serviceability (see
Fig D(iii)).
3. When re-attaching wrapper, ensure each side of wrapper is engaged to
pivoting bracket (see Fig D(v)).
4. Once the wrapper is in place, rotate wrapper up and under the shroud.
Ensure thru holes on wrapper are aligned with plastic bushing threads on the
frame prior to engaging security screws. Ensure screw is angled relative to
the ground and perpendicular to wrapper surface prior to engagement. Hand
tighten prior to using hand tool to avoid cross-threading.
5. Four plastic bushings are located in the cross brace of the frame. The
lower two bushings align with wrapper holes and the top two bushings are
extras in case of replacement (see Fig D(iii)).
NOTE:
The highlighted portion in red color is acceptable plumbing rough-in for
installation.
NOTE:
To mitigate the wrapper rotation interferences, zip tie lines (plumbing and
electrical) running between the cooler units to the waste line (PVC pipe).
HANGER BRACKETS INSTALLATION
- Remove hanger bracket fastened to back of coolers by removing one (1) screw.
- Determine your mounting configuration from the figures shown on pages 2 –
- Refrigeration unit must be on right hand side.
IMPORTANT NOTE: If the Bottle Filler is to be mounted on the left hand cooler, a basin assembly change will be needed.
Determine your configuration by referring to the Configuration Instructions on page 10 prior to continuing.
- Mount the hanger bracket as shown in Figures 1 – 4 (Pages 2 – 5).
NOTE: Hanger Bracket MUST be supported securely. Add fixture support carrier if wall will not provide adequate support. Anchor hanger securely to wall using all six (6) 1/4 in. dia. mounting holes.
IMPORTANT: 5-7/8 in. (150 mm) dimension from wall to centerline of trap must be maintained for proper fit.
- Connect the supply water to the filter 3/8” copper inlet tube.
10)Connect the waterline from the outlet of the filter to the inlet of the evaporator in the refrigerated cooler by inserting it into the quick connector.
11)Connect the waterline from the solenoid in the non-refrigerated cooler to the open 1/4” inch tee fitting in the refrigerated cooler.
12)Find your cooler configuration on page 11 and connect the drain assembly together.
13)Install trap.
IMPORTANT: If it is necessary to cut the drain, loosen the screw at the black rubber boot and remove tube, check for leaks after re-assembly.
-
Remove two (2) mounting screws with 5/32” Allen wrench holding Bottle Filler to wall mounting plate (See Fig. 8). Note do not discard mounting screws, they will be needed to secure Bottle Filler to wall mounting plate.
-
Remove wall mounting plate from Bottle Filler (See Fig. 8 ). Place wall mounting plate against wall on top of basin. Center the wall mounting plate side to side with the basin. Mark the six (6) mounting holes with a pencil (See Fig. 1, Pg. 2). Place tape over wiring harness connection on top of cooler to prevent debris from falling into Connection(See Fig. 6, Pg. 7).
-
Remove wall mounting plate from wall. NOTE: Mounting plate MUST be supported securely. Add fixture support carrier if wall will not provide adequate support.
-
Install wall mounting plate to wall using six (6) 7/16” obround mounting holes (mounting bolts not included) (See Fig. 7, Pg. 7). Use appropriate fasteners for your wall type.
-
Install gasket on bottom of Bottle Filler with gasket support bracket & (2) screws. (See Fig. 8).
-
Route 3/8” tubing through the opening in the bottle filler gasket and plug into bulkhead fitting in basin. Route the wiring harness through the gasket and plug into the connector on the top of the basin. Water line should be cut to length prior to attaching to bulkhead fitting.
-
Place Bottle Filler on the four (4) hooks on the mounting plate installed on wall.
FINAL INSTALLATION (FILTER)
- Remove filter from carton, remove protective cap, attach filter to filter head by firmly inserting into head and rotating filter clockwise. Ensure that front facing label can be read when filter is installed. (See Fig. 12)
- Turn water supply on and inspect for leaks. In both cooler and Bottle Filler. Fix all leaks before continuing.
- Once cooler and bottle filter have been inspected for leaks and any leaks corrected, plug cooler into wall.
- Reinstall two mounting screws from first step above. Caution do not over tighten screws.
- Once power is applied to the cooler the GREEN LED light will illuminate on the bottle filler showing good filter status along with the LCD Bottle Counter.
- Verify proper dispensing by placing cup, hand, or any opaque object in front of sensor area and verify that the water dispenses. Note: the first initial dispenses might have air in line which may cause a sputter and hazy appearance. Run water and flush filter to purge air and fine carbon particles from filter before use. This will be eliminated when all air is purged from the line.
- Once unit tests out, install Lower Panels back on water coolers. (See pages 12-13 for versatile wrapper installation).
- When re-attaching wrapper, push wrapper up and under the shroud. Make sure wrapper and bushing holes are aligned prior to inserting screw. Units are now ready for use.
INSTRUCTIONS FOR REPLACING FILTERS
- Refer Fig D(i) to D(iv), Pg. 6 for wrapper removing instructions.
- Turn off water supply; dispense water to relieve pressure.
- Remove power by unplugging cooler.
- Turn used filter counterclockwise 1/4 turn to remove from filter head.
- Remove cap from new filter and use to seal used filter.
- Insert new filter into existing filter head and turn fully clockwise. Make sure you can read the label on the front of the filter once it is installed. (See Fig. 12).
- Plug in unit to restore power.
- Turn on water supply and run water and flush filter to purge air and fine carbon particles from filter before use. Visit elkay.com/filtration for additional details. Also run water through bottle filler until all air is removed and water flow is clear.
Note: Filter status light will automatically reset once new filter is installed.
INSTRUCTIONS TO ACCESS PROGRAMMING BUTTON
- Remove lower cover on refrigerated unit by removing (2) screws.
- Button is located in lower right corner of unit (See Fig. 13).
CONFIGURATION INSTRUCTIONS
INSTRUCTIONS TO MOVE THE BOTTLE FILLER & BASIN TO THE LEFT SIDE (NON- REFRIGERATED) FOR ALTERNATE MOUNTING VERSATILE BI-LEVEL
Enhanced EZH2O Error Codes
Error Code | Error Description | Corrective Action |
---|---|---|
Please clear Bottle Filler | • Remove obstruction |
• Clean lens on IR sensor
• Unplug unit for at least 30 seconds and restart
• If error repeats, replace IR sensor
E013| Missing or Incompatible Filter| • Check that filter is installed
correctly (label facing forward, round blue tag facing NFC Board)
• Unplug unit for at least 30 seconds and restart
• Replace filter
• Replace filter head assembly with repair kit
• If error repeats, contact certified service professional
E013| Missing/Unplugged NFC| • Unplug unit for at least 30 seconds and
restart
& E014| Board| • Verify cable connector is plugged into NFC board on filter
head assembly
• Replace filter head assembly with repair kit
| | • If error repeats, contact certified service professional
PLUMBING DIAGRAMS VERSATILE BI-LEVEL
Versatile Wrapper and Trim Kit Installation Instructions
Versatile Wrapper and Trim Kit Installation Instructions continued. . .
Instrucciones de instalación versátiles de la envoltura y del juego de
molduras continuadas. . .
Instructions d’installation du kit d’emballage et de garniture polyvalentes
(suite). . .
115V Refrigerated Wiring Diagram with Alpha/Numeric Display
Service Instructions
Programming Instruction
Pictured is unit only without bottle filler.
Note: Danger! Electrical shock hazard. Disconnect power before servicing unit.
ATTENTION:
If the product serial number is before 190424189, please refer to archived
documents section of Elkay.com for the most accurate
parts list. (www.elkay.com/archived-documents)
FCC COMPLIANCE STATEMENT
CAUTION: Changes or modifications not expressly approved could void your authority to use this equipment This device complies with Part 15 of the FCC Rules. Operation to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation
INDUSTRY CANADA STATEMENT
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816
PARA PIEZAS, CONTACTE A SU DISTRIBUIDOR LOCAL O LLAME AL 1.800.834.4816
POUR OBTENIR DES PIÈCES, CONTACTEZ VOTRE DISTRIBUTEUR LOCAL OU COMPOSEZ LE
1.800.834.4816
Frequently Asked Questions (FAQ)
Q: Can the cooler be installed in any orientation?
A: No, the cooler must be installed following specific left-hand high or left- hand low configurations as mentioned in the manual.
Q: Is a basin change necessary for installation?
A: A basin change may be required depending on the desired rough-in. Refer to the manual for more details.
References
- Berl's Commercial Supply | Restroom Accessories & Fixtures | Drinking Fountains
- P65Warnings.ca.gov
- Patents | Zurn Industries LLC's products
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>