Package contents
DIMENSIONS
SPECIFICATION
- Nominal supply voltage: 12 V
- Tension tolerance: +/- 30%
- Min. feeding tension: 8 V
- Maximum supply voltage: 16 V
- Power of nominal supply voltage: 36 W
- Auto-resettable Fuse:
- Current protection intervention: 5 A
- Wire section: 17 AWG – 1 mm²
- Min. electric input: 0,2 A +/- 10%
- Max. electric input: 3,0 A +/- 10%
- Operating temperature: -10°C / +70°C
- Storage temperature: -20°C / +80°C
Check that nothing has been damaged or deformed during transport.
In the event of doubts or questions concerning the installation, use or
limitations of the product, contact the dealer. We recommend that the
installation is carried out by qualifi ed personnel and in compliance with
current local regulations.
Installation instructions
-
Decide where the roofl ight should be installed and make a square hole of 39cm.
The roofl ight can be installed on roofs with thickness between 30 and 85mm. -
Do not forget to arrange the electrical connection directly from the battery (only 12Vdc – NOT 220V).
-
Seal the lower part of the external frame with a minimum width of 30 mm by following the appropriate rails. Recommended sealant: SIKALASTOMER-710 / THEROSTAT II / DEKALIN 1512.
-
Place the external frame in the opening hole making sure that the hinges are facing the front of the vehicle.
-
Fasten the external frame with 20 self tapping screws (Ø4.2x30mm UNI EN ISO 7049). Carefully siliconate all the perimeter of the external frame, fi ll any spaces between the roof and the frame and all the heads of the 20 screws.
-
Connect the input cables of the electric motor.
-
Fasten the internal frame with 8 self tapping screws (Ø3.5x15mm UNI EN ISO 7049). Remove the protective plastic applied to the cover (do not expose the product to sunlight for too long to avoid to make this operation diffi cult).
Instructions for use
Caution! Do not reverse polarity and position of wiring.
Ensure that the power supply has been disconnected before carrying out any kind of operation, then reconnect.
- Polar Control function
- Fan ignition air inlet
- Fan ignition air outlet
- Regulation fan speed
POLAR CONTROL
-
The Polar Control function automatically activates the ventilation depending on the set ΔT and on the outdoor temperature.
-
The room temperature will be displayed by switching on the Polar Control function; by adjusting the key and the requested ΔT, the fan will rotate until reaching the temperature set value.
-
The switching on and off of the the Polar Control causes the RESET of the displayed room temperature. To limit the consumption of energy, we recommend to set the
-
Polar Control to the minimum ΔT-1°C once reached a comfortable room temperature.
-
Notes: the cooling capacity of the fan depends on the difference between outdoor temperature and the room temperature
-
ΔT = difference between the room temperature and the required temperature.
-
Polar Control off
-
Lowest cooling
-
Maximum cooling
In case of problems please contact your local dealer indicating the data on the nameplate. Consult our website for spare parts drawing.
- Fiamma declines all responsibility for any personal injury and damage to property due to incorrect assembly or use of the product; it is suggested to keep the instructions inside the vehicle.
- The assembly of the product must be carried out according to the assembly instructions: the product must not be modifi ed in any way.
- Before proceeding with assembly, check that the roof thickness is compatible with the product.
- Before choosing the place where to assembly the roofl ight, check that:
- the product doesn’t interfere with adjacent accessories (luggage racks, cables, reinforcements in the roof, cabinets inside the passenger compartment).
- the internal and external surface of the roof is fl at.
- Periodically check the tightness of all the screws in the roofl ight, especially after the fi rst kilometres from the installation and always before and after long trips. If the opening-closing device hardens, lubricate the lid opening device with a few drops of grease. It is forbidden to walk on the product cover.
Before starting the vehicle, check that the roofl ight is properly closed. Periodically check that the cover is intact. Don’t open the roofl ight when the vehicle is travelling. Don’t open the roofl ight in case of strong wind or rain. Remove snow or ice from the roofl ight. Always comply with speed limits and the Highway Code. The speed should always be suitable to traffi c conditions and transported load.
CARE AND MAINTENANCE
For the internal and external cleaning of the roofl ight, always use only neutral, non-aggressive detergents. For cleaning the Crystal cover use an acrylic glass cleaner with a soft cloth so as not to scratch the surface. Never use aggressive products such as glass cleaners, all-purpose cleaners, abrasives or dish-washing detergents. Also, never use alcohol-containing detergents, solvents or any corrosive liquid. The mosquito net can be cleaned with water and a neutral detergent.
Accessories
Declaration of Conformity (DoC)
Warranty Fiamma
In case of defects with regards to materials and manufacturing, the customer
is entitled
to the warranty in accordance with local laws and regulations of the country
in which the product was purchased.
Fiamma S.p.A. – Italy
Via San Rocco, 56
21010 Cardano al Campo (VA)
All rights reserved.
Fiamma S.p.A.
reserves the right to modify at any time, without notice, prices, materials,
specifi cations and models or to cease production of any model.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>