Sunco DL_SMDR56-13W-27K_5K 6 LED Retrofit Selectable Smooth Downlight User Manual

July 16, 2024
SUNCO

Sunco DL_SMDR56-13W-27K_5K 6 LED Retrofit Selectable Smooth Downlight

Product Details

  • Voltage: Compatible with standard voltage
  • Wattage: 13W
  • Wattage Equivalency: Equivalent to a 75W incandescent bulb
  • Beam Angle: Wide beam angle for uniform lighting
  • Weight: Lightweight and easy to install
  • Housing Material: Durable construction
  • Dimmable: Compatible with various dimmer brands
  • Model: DL_SMDR56-13W-27K_5K

User Manual
6″ LED Retrofit Selectable Smooth Downlight
SKU: DL_SMDR56-13W-27K_5K

support@sunco.com 844-334-9938

Whats in the Box

Retrofit Downlight

Before You Start

Safety Information

To reduce the risk of fire, electric shock, or physical injury:

  • Turn off circuit breaker before installing this fixture.
  • This product should be installed by a person familiar with the construction and operation of the product the hazards involved. Safety eyeglasses and gloves are recommended.
  • Abide by related regional and local laws or regulations.
  • Proper grounding is required to ensure safety.
  • Do not alter, relocate, or remove wiring during installation.
  • Do not make or alter any open holes in wiring enclosure or electrical components during installation.
  • Check for shipping damage before insatalling. If the product is damaged, do not use it.
  • Keep fixture away from corrosive substances.
  • Suitable for damp locations at temperature ranging from 4°F to 104°F. Not for use where directly exposed to water.
  • Clean the fixture regularly to ensure proper operation. Do not clean with harsh solvents.
  • Use safety precautions and abide by regional and local laws or regulations.
  • This product is not compatible with 3rd party sensors.
  • This product is not compatible with photo controls.
  • This product is not compatible with occupancy sensors.
  • This product is not compatible with timing devices.

WARNING:
Cancer & Reproductive Harm- www.P65Warnings.ca.gov

This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference that may cause undesired operation. Please review all instructions carefully prior to installation.

Quickstart Guide

Installation Guide

  • STEP 1
    a. Turn off circuit breaker before installation.
    b. Locate the housing.
    NOTE: Remove previous fixture. Fixture may be hot so allow time to cool after turning off power.

  • STEP 2
    Secure the clip springs firmly within the retrofit connector.
    (Caution: Avoid excessive force when holding down the spring. If the spring is not locked, attempt to resolve the issue by turning it over.)

  • STEP 3
    Determine the type of connector available.
    TP24 Connector(1) -E26 Base(2)

  • STEP 4
    a. Connect the appropriate adapter to make connection in the housing.
    NOTE: the wires may come lose from the connectors soensure they are attached.
    b. Tuck all wires into the can.

  • STEP 5
    a. On back of retrofit fixture, slide the CCT Selection Switch to choose from five color temperatures. Try each CCT to determine best fit.
    b. Turn off light switch after selecting your choice and continue install.

  • STEP 6

    • a. Line up trim ring with opening.
    • b. Push downlight into can until secure. Compression clips will hold retrofit light in place. Push up springs into can clips.
    • c. Turn on circuit breaker and test light.

Product Details

Recommended Dimmers

Brand Model
LUTRON MACL-153M-WH
LUTRON DVCL-153P-WH
LUTRON PD-6WCL-WH-P
LUTRON AYCL-153P-WH
LUTRON P-PKG1WB-WH
LUTRON SCL-153P-WH
Cloudy Bay CBLD001WH
GE 93120079

Scan for the full compatible dimmer list

Specifications

Voltage 120V Average Lifetime 50000 hrs
Wattage 13W Lumens 965LM
Wattage Equivalency 120W Moisture Rating Damp
Beam Angle 90° CRI 80+
Weight 0.3lbs Usage Indoor
Housing Material PC IC Rated Yes
Dimmable Yes Warranty 7 Years

Common Troubleshooting

  • Feeling in the dark about an issue with your product? No worries! Our troubleshooting section is here to shed some light and provide you with easy-to-follow solutions for any problem.
  • If you still need some assistance, please feel free to contact us with any questions. Our team of lighting experts are happy to help brighten your day.

Light Distribution Angle

  • Lighting distribution angle refers to the spread of light emitted from a light source. It is an important factor to consider when selecting a fixture or bulb, as it affects the way it will illuminate an area. There are two main types of lighting distribution angles:
    A symmetric lighting distribution emits light evenly in all directions, creating a cone-shaped pattern that provides a pool of light. This type of lighting is ideal for general lighting and illuminating large areas. Common applications for symmetric lighting include general area illumination, security lighting, and perimeter lighting. Symmetric lighting is also used to a certain degree in up-lighting.

  • An asymmetric lighting distribution angle, also known
    as beam angle, creates a pattern that focuses light in a specific direction. This type of lighting is ideal for task lighting as it reduces glare and light spill in other areas. Common applications include task lighting in spaces such as landscape settings, retail stores, museums,
    and much more.

  • It is important to note that the lighting distribution angle can also be affected by other factors such as the reflector design of the light source, the type of lens used, and the distance between the light source and the surface being illuminated.

support@sunco.com
844-334-9938

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals