rako RMS-800 Wireless Inline Non Dimming Switch Module Instruction Manual

July 16, 2024
rako

rako RMS-800 Wireless Inline Non-Dimming Switch Module

Specifications

  • Product: RMS-800
  • Capacity : 800VA
  • Compatibility : Non-dimmable loads such as lighting, fans, pumps, contactors
  • Minimum Load: 1VA
  • Installation: To be carried out by a competent electrician

Product Usage Instructions

Installation

  1. Installation should only be carried out by a competent electrician.
  2. Mount the RMS-800 modules in well-ventilated, dry areas away from enclosed metal casings.
  3. Mount the modules vertically with terminals at the bottom or horizontally.
  4. Ensure the cable clamp is fitted tightly to secure the cables.

Setup

  1. Remove the cover and cable clamp from the RMS-800.
  2. Insert the supply IN conductors as well as the load OUT conductors.
  3. Replace the cable clamp, ensuring the cables fit securely.
  4. Replace the cover.

Programming

  1. Power up the RMS-800 and test it with the setup button.
  2. Once tested, the device is ready to be programmed using the Wireless Module Setup Guide.

FAQ

  • What is the recommended load for the RMS-800?
  • The RMS-800 is suitable for non-dimmable loads ranging from 1VA to a maximum of 800VA.
  • How can I improve wireless reception for the RMS-800?
  • If experiencing bad wireless reception, consider installing a wireless repeater (WRB-100) to extend the range.

For more information relating to the RMS-800, see the Wireless Module Application Sheet, Wireless RAK Application Sheet, and Wireless Device LED Diagnostics . For programming a wireless system, include the device in this manual: Wireless Module Programming Guide

What is the RMS-800?

The RMS-800 is a wireless switching module suitable for use with non-dimmable loads such as:

  • Non-dimmable lighting
  • Fans
  • Pumps
  • Contactors

RMS800 modules can be controlled by any Rako device that transmits wireless RAKOM messages.

Loadings

Minimum Maximum
1VA 800VA

NB Inrush currents must be taken into account when calculating the load for the RMS-800

Installation

WARNING

Installation should only be carried out by a competent electrician.

  • RMS-800 modules should be mounted in areas that are adequately ventilated, dry, and outside of any enclosed metal casings that may interfere with the wireless signal.
  • Modules should be mounted vertically, with the terminals at the bottom, or horizontally.
  • While the modules are designed to be maintenance-free, they should be mounted i n an accessible location should investigation or re-addressing of the units be necessary.
  • Ensure that the cable clamp is fitted tightly to secure the cables.

rako-RMS-800-WAireless-Inline-Non-Dimming-Switch-Module
-FIG-1Initial Checks

  • When power is initially connected to the module, the load should power up to full brightness.
  • The clear button can be used as a manual on/off switch to test the circuit.
  • The internal LED behind the clear button will flicker when the module receives any Rako wireless message and is a useful diagnostic indicator.
  • This function becomes inactive after 20 minutes to avoid a nuisance light spill but can be re-activated by pressing the clear button.
  • Should the module not respond to any of the above, further investigation must be made before proceeding further.

Programming the RMS-800

Once the RMS-800 has powered up and has been tested working with the setup button, the device is ready to be programmed. For instructions on how to program the RMS-800, see the Wireless Module Setup Guide

Thank you for choosing Rako Controls; we hope that you are pleased with your system. Should you require further assistance, please contact us via our website, www.rakocontrols.com, or by calling our customer support helpline on 01634 226666.

Appendix 1: LED Diagnostics

rako-RMS-800-Wireless-Inline-Non-Dimming-Switch-Module
-FIG-2

Should the module not respond to any of the above, check the supply voltage.