HVACQuick AH2-AF-HC Hydronic Coil Module Owner’s Manual

July 14, 2024
Hvacquick

HVACQuick AH2-AF-HC Hydronic Coil Module

HVACQuick-AH2-AF-HC-Hydronic-Coil-Module-product

Product Information

Specifications

  • Model: AH2-AF-HC
  • Type: 4-Ton Hydronic Coil Module
  • Press. Drop @550 CFM: 0.10 inch W.C.
  • Press. Drop @750 CFM: 0.13 inch W.C.
  • Press. Drop @1000 CFM: 0.19 inch W.C.
  • Press. Drop @1200 CFM: 0.26 inch W.C.
  • Press. Drop @1600 CFM: 0.38 inch W.C.

Product Usage Instructions:

Installation

  1. Ensure the area where the Hydronic Coil Module will be installed is clear and accessible.
  2. Follow the manufacturer’s guidelines for connecting the module to the existing system.
  3. Securely fasten the module in place using appropriate tools and hardware.

Operation

  1. Turn on the system and adjust the airflow to the desired CFM level based on the provided Press. Drop values.
  2. Monitor the performance of the module regularly to ensure optimal functioning.
  3. Refer to the user manual for any troubleshooting or maintenance requirements.

Maintenance

  1. Regularly inspect the Hydronic Coil Module for any signs of damage or wear.
  2. Clean or replace filters as recommended by the manufacturer to maintain efficiency.
  3. Schedule professional maintenance checks to keep the module in top condition.

FAQ

  • Q: How often should I replace the filters?
    A: It is recommended to replace the filters every 3-6 months, depending on usage and environmental conditions.

  • Q: What should I do if I notice a decrease in performance?
    A: Check for any obstructions or blockages in the module, ensure proper airflow, and consider scheduling a maintenance check.

AH2-AF-HC
AH2 – 4Ton Hydronic Coil Module

Features

  • The AH2 A-Frame Hydronic Coil Module is part of a series of modules that can be combined to form a custom multi-functional Air-Handler.
  • This Modular approach allows for an adaptive installation as each module can be rotated, minimizing installation cost by adapting to installation needs.
  • The AH2-AF-HC is constructed out of Aluminum, (63 lbs) and includes mounting screws on every corner.
  • The Coil Box is capable of 56000 BTUH* and is designed for glycol and/or water systems.
  • The AH2-Hydronic Coil Module** provides four 0.5” O.D. connections with feed indicator labels.
  • Includes 2 Front Panel Static Ports to measure the coil’s differential pressure giving an indication of the airflow***.
  • Replaceable coils with a screw-on Access Panel.
  • Round and Square Custom Intake and Exhaust Duct adapters are available; Call HVACQuick.com @ 888-855-7229 or team@hvacquick.com.

HVACQuick-AH2-AF-HC-Hydronic-Coil-Module- \(2\)HVACQuick-AH2-AF-HC-Hydronic-Coil-Module-01

Units are in inches, The Pressure Drop over the Coil is approximate as every installation and environment varies.

  • The actual BTUH can vary with the medium and or mix rate used. The 56000 BTUH given here is therefore an approximation.
  • The Hydronic Coil Module does not have a drain pan and so is only capable of heating cycles.
  • The provided Front Panel Static Ports can be connected to an analog or digital manometer to provide indication of the pressure drop over the Coil which gives an indication of the Actual Air Flow over the coil. ALWAYS heat the 1/8” tubing before installing or removing tubing.

NOTE: remove the door and the caps sealing the front ports to use the 1/8” tube barbs underneath, reinstall the door with the tubing through the holes.

© AirScape AH2-AF-HC, February 2024, All Rights Reserved.