Specifications

  • Inlet Water Temperature: 2.0 – 3.0
  • Inlet Connections: 3/4 BSP
  • Outlet: 1.0 – 4.0
  • Pressure BAR: 0 – 5.0
  • Maximum Static Pressure: 10.0 bar
  • Pack Contents: M24 Recessed Flow Straightener, x1 Naxos Tap, x2 Washer, x2 Backnut, x2 Plinth, x2 Washer, x1 Outlet Key

Installation Instructions

  • All products manufactured and supplied by Bristan are safe to use provided that they are installed, operated, and receive regular maintenance by the instructions.
  • Isolation valves must be fitted to the inlet water supplies to ensure ease of future maintenance.
  • Before installing, flush the water supply thoroughly to remove any swarf or solder.
  • Ensure full access is available for future maintenance/servicing purposes.
  • Do not modify the product as it will invalidate the guarantee.
  • Align the plinths with the tap body and ensure rubber plinth seals are in place.
  • Feed the threaded tails through tap holes.
  • Secure the taps to the bath using a box spanner to tighten the metal backnuts underneath ensuring the washer is correctly positioned.
  • Connect the hot and cold water supplies to the threaded tails.

Bristan products should be cleaned with warm water, and mild pH-neutral liquid soap, and polished with a soft cloth. Rinse off residues from soap, toothpaste, shampoos, and shower gels immediately after use to prevent blemishes.

FAQ

  • Q: Where can I find spare parts for my tap?
  • A: To replace any spare parts for your tap, you can scan the QR Code or visit www.bristan.com and search for your product.

Please leave these instructions with the end user Naxos Bath Filler | NAX BF C (D2)

Specifications

BRISTAN-NAX-BF-C-D2-Naxos-Bath-Filler-FIG-1

Pack Contents

BRISTAN-NAX-BF-C-D2-Naxos-Bath-Filler-FIG-2

Operation

BRISTAN-NAX-BF-C-D2-Naxos-Bath-Filler-FIG-3

Tools Required for Installation/ Maintenance

BRISTAN-NAX-BF-C-D2-Naxos-Bath-Filler-FIG-4

Prior to Installation

  • All products manufactured and supplied by Bristan are safe to use provided that they are installed, operated, and receive regular maintenance per these instructions.
  • This product needs to be installed under, and meet the requirements of The Water Supply (Water
  • Fittings) Regulations (Northern Ireland) 2009 and The Water Supply (Water Fittings) (Scotland) Byelaws 2014.
  • For full Installation Requirements & Notes (IRN) please visit www.wrasapprovals.co.uk/approvals-directory. Isolation valves must be fitted to the inlet water supplies to ensure ease of future maintenance.
  • Before installing this product the water supply must be thoroughly flushed in order to remove any swarf, solder, etc.
  • Full access must be made available for future maintenance/servicing purposes.
  • This product must not be modified in any way as this will invalidate the guarantee.

Spare Parts

  • To replace any spare parts for your tap, why not scan the QR Code or visit www.bristan.com and search for your product.

Important
The images shown are for illustrative purposes only.
The tap you have purchased may look different from those pictured in this booklet but will follow the same installation steps.

Your contents page will be specific to your product
If you find your product or any of its components differ from those shown on the contents page, please contact our customer support.

Installation

  • Feed the tap body through the plinths and ensure rubber plinth seals are in place
  • Once aligned, feed the threaded tails through tap holes

BRISTAN-NAX-BF-C-D2-Naxos-Bath-Filler-FIG-6

  • Some plinths will need to be aligned with a pre-attached grub screw in the tap
  • Align the hole on the plinth with the exposed grub screw and ensure the rubber seal is correctly in place before attaching washer and back nut

BRISTAN-NAX-BF-C-D2-Naxos-Bath-Filler-FIG-7

  • To secure the taps to the bath, use a box spanner to tighten the metal back nuts underneath ensuring the washer is correctly positioned in between the back nuts and the bath

BRISTAN-NAX-BF-C-D2-Naxos-Bath-Filler-FIG-8

  • Connect the hot and cold water supplies to the threaded tails

BRISTAN-NAX-BF-C-D2-Naxos-Bath-Filler-FIG-9

General Cleaning

  • Bristan products are made from premium materials, with hand-polished, electroplated, PVD or EPD finishes.
  • Your taps or shower should be regularly cleaned with warm water, a mild pH-neutral liquid soap, and polished with a soft cloth. Any residues from soap, toothpaste, shampoos, and shower gels can cause blemishes if not rinsed off straight after use.
  • Household bleaches and cleaners contain harsh chemicals and may damage the surface finish. Avoid using abrasive cloths, scouring pads, scrub sponges, steel wool, or anything similar.

Maintenance – Valve Replacement

PLEASE NOTE – Taps shown in these instructions are for illustration purposes only. All taps can be maintained using these instructions.

NOTE: Grub screw and cap can also be located at the front of the handle depending on your tap.

  • Remove the handles depending on the style of your tap, including any spline adaptors if used.
  • Unscrew the handle and washer to remove the handles.

BRISTAN-NAX-BF-C-D2-Naxos-Bath-Filler-FIG-10

  • Remove the shrouds, screws, and spline adaptors if your model has them.
  • When replacing, ensure the valve is fully closed with the handle parallel to the spout.

BRISTAN-NAX-BF-C-D2-Naxos-Bath-Filler-FIG-11

  • Remove the valve using the tool required for your tap. Check any seals and O-rings for damage. Replace the valve if necessary.

BRISTAN-NAX-BF-C-D2-Naxos-Bath-Filler-FIG-12

  • Take care when removing/replacing your long stemmed valve, as the finish could be damaged or scratched.

BRISTAN-NAX-BF-C-D2-Naxos-Bath-Filler-FIG-13

Maintenance – Clean/ Replace Outlet

  • Using an adjustable spanner, unscrew gently to remove the outlet

BRISTAN-NAX-BF-C-D2-Naxos-Bath-Filler-FIG-14

  • If provided, insert the key tool into the outlet and twist to release it

BRISTAN-NAX-BF-C-D2-Naxos-Bath-Filler-FIG-15

  • Using a coin, insert into the slot on the outlet and twist to release it

BRISTAN-NAX-BF-C-D2-Naxos-Bath-Filler-FIG-16

  • Check all loose parts for any damage, then soak using a suitable solution to de-scale

BRISTAN-NAX-BF-C-D2-Naxos-Bath-Filler-FIG-17

  • Reverse the steps to replace the outlet

BRISTAN-NAX-BF-C-D2-Naxos-Bath-Filler-FIG-18

Troubleshooting

Symptom Cause Remedy
No flow or low flow rate Partially closed isolation valve. Open isolation

valve.
The head of water is below the minimum distance required.| Refer to the specification for the minimum distance required.
Hot or cold water being drawn off elsewhere causing pressure changes or instantaneous boiler temperature changes.| Do not use other water outlets when using the taps.
Airlock or partial blockage in the supply pipework.| Flush through pipework to ensure the removal of debris and any airlocks.
Water dripping from taps| This is normal for a short time after using the taps.| This is caused by residual water tension, the build up of water in the tap body.
If water continues to drip, possibly due to the ceramic disc valves| Remove valves and clean them, refer to the ‘Maintenance’ section before starting any maintenance.
Taps do not turn on| Closed isolation valve.| Open isolation valve.
The mains water supply was turned off.| Turn on the mains water supply.

Guarantee

Our Guarantee

  • At Bristan, we want to make things as easy as possible for our customers. That’s why we offer solid guarantees on all our products, effective from the date of purchase, to give you peace of mind.
  • To start your free guarantee simply scan the QR code and register your product.
  • Alternatively, visit www.bristan.com/register.
  • For any other queries, please call our Customer Service on 0330 026 6273 where our expert team of advisors will be able to offer you any help and advice.
  • For full guarantee terms and conditions visit www.bristan.com/service-centre/guarantees.

BRISTAN-NAX-BF-C-D2-Naxos-Bath-Filler-FIG-20

Contact Us

  • Bristan Group Ltd.
  • UK: Bristan Group, B78 1SG.
  • EU: Masco Europe S.à.r.l.
  • 14 Rue Strachen
  • 6933 Mensdorf