KOHLER Rite-Temp K-P8304-SWX Valve Body and Cartridge Kit Owner’s Manual
- July 12, 2024
- Kohler
Table of Contents
KOHLER Rite-Temp K-P8304-SWX Valve Body and Cartridge Kit
Features
- Project pack: Supplied 12 per case
- Includes valve body, pressure balance cartridge, rough-in guide, and mudguard
- 1/2″ (12.7 mm) sweat only inlets and outlets
- 5 gpm (18.9 l/min) maximum flow rate at 45 psi
- Single lever design cycles from off through cold to hot
- Anti-scald protection
- One-piece cartridge design simplifies installation and maintenance
- Adjustable high-temperature limit stop to control maximum water temperature
- Requires valve trim to complete installation (sold separately)
- Pressure-balancing diaphragm technology maintains outlet temperature within +/-3°F during water pressure fluctuations
Material
- The forged dezincification-resistant brass body provides long-term reliability and resistance to aggressive water conditions
Installation
- Designed for use in standard, back-to-back, and thin wall installations
- The valve body features integral mounting locations and symmetrical valve inlets to simplify installation
- The cartridge is reversible for installations where hot and cold supplies are reversed
- Rough-in guide designed for both standard and thin wall installations
- Installed valve rough-in can be flushed and pressure-tested to 150 psi max (air or water) without cartridge by using a test cap (sold separately)
Optional Products/Accessories
- K-10350 Deep rough-in kit
- K-10351 Test cap for K-8300 Series valve bodies
Codes/Standards
ASME A112.18.1/CSA B125.1 ASSE 1016/ASME A112.1016/CSA B125.16 IAPMO
Certification
KOHLER® Faucet Lifetime Limited Warranty
See website for detailed warranty information.
DIMENSION
Technical Information
All product dimensions are nominal.
Shower Valve
- Pressure:
- Maximum (Static) Pressure:
- Minimum (Operating) Pressure:
- 45 psi (3.1 bar)
- 125 psi (8.6 bar)
- 20 psi (1.4 bar)
Notes
Install this product according to the installation guide. Avoid cross-flow
conditions. Do not install a shut-off device on either valve outlet. Cap the
shower outlet if the deck-mounted spout, diverter, or hand shower is connected
to the spout outlet. Install straight pipe or tube drop of 7″ (178 mm) to 18″
(457 mm) with single elbow between the valve and wall-mount spout. For
finished walls greater than 3/4″ (19 mm) and less than 1-1/2″ (38 mm), install
support(s) 2″ (51 mm) from the stud face. For finished walls greater than
1-1/2″ (38 mm), install support(s) 3″ (76 mm) from the face of the finished
wall.
1-800-4KOHLER (1-800-456-4537) Kohler Co. reserves the right to make revisions without notice to product specifications. For the most current Specification Sheet, go to www.kohler.com USA or www.kohler.ca Canada 6-15-2024 20:55 – US