Product Specifications:
- Model: 758.144533
- Capacity: 13 Gallon
- Type: Whole House Humidifier
- Output: 13 Gallons
- Technology: Innovative Twin Fan Technology
Product Usage Instructions:
General Safety Instructions:
It is important to follow the safety instructions provided to
ensure safe operation of the humidifier. Here are some key safety
guidelines:
- Read all instructions carefully.
- Keep the humidifier clean.
- Avoid putting foreign objects inside the humidifier.
- Never use the humidifier with any part missing or damaged.
- Avoid touching controls with wet hands.
Assembly:
Before using the humidifier, make sure to assemble it properly
by following the assembly instructions provided in the manual.
Ensure all parts are securely in place before operating the
unit.
Humidifier Operations:
To operate the humidifier:
-
Plug the humidifier directly into a 120V, A.C. electrical
outlet. Avoid using extension cords. -
Keep the electric cord away from traffic areas and potential
hazards like heat sources. -
Always unplug the humidifier before moving, cleaning, or
servicing it. -
Follow the manufacturer’s recommendations for filling the
humidifier with water.
FAQ:
How often should I clean the humidifier?
It is recommended to clean the humidifier regularly, at least
once a week, to prevent mold and bacteria buildup.
Can I use essential oils in this humidifier?
Avoid using essential oils or any other additives in the
humidifier as they can damage the unit and void the warranty.
What should I do if the humidifier stops working?
If the humidifier stops working within the warranty period,
contact Sears for repair or replacement options as per the warranty
terms.
“`
This Owner’s Manual is provided and hosted by Appliance Factory Parts.
Kenmore 144533 Owner’s Manual
Shop genuine replacement parts for Kenmore 144533
Find Your Kenmore Humidifier Parts – Select From 496 Models ——– Manual
continues below ——–
f/_ Save This Manual for Future Reference
owner’s manual
Model No.
758.144533
13 Gallon
COMFOR
FOR YOUR S_AFETY
READ ALL INSTRUCTIONS
CAREFULLY
WHOLE HOUSE HUMIDIFIER
13 Gallon Output
Innovative Twin Fan Technology
· Operating Instructions · Parts List
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
Part No. SP6167
Printed in Canada
FULL ONE YEAR WARRANTY ON HUMIDIFIER
If within one (1) year from the date of purchase, this humidifier fails due to a defect in material or wQrkmanship, Sears will repair it, free of charge. If within two (2) years from the date of purchase, the motor fails due to defect in material or workmanship, Sears will repair it free of charge.
This warranty service is available by simply returning the humidifier to the nearest Sears Service Center/Department throughout the United States.
This warranty applies only while this product is used in the United States.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Sears, Roebuck and Co., 13/8t7 WA, Hoffman Estates, IL 60179
_1
GENERAL SAFETY INSTRUCTIONS
Safety Signal Words
DANGER: means if the safety information is not followed someone will be
seriously
injured or killed.
humidifier is not in service.
4. Keep the humidifier clean. 5. Do not put foreign objects inside the
humidifier.
WARNING: means if the safety information is not followed someone could be
seriously injured or killed.
CAUTION: means if the safety informa-
6. Never use your humidifier while any pa is missing or damaged in any
rnanne,_
7. To reduce the risk of electrical hzard …….
0:damage,.t.humidiSer..ot.t, ijl:?
tion is not followed someone may be seri-
or tip humidifier while unit is running,i, i
ously injured.
-8:’To”reduce’the’risk” of’datl”Pa_’tO
1. To reducethe risk offire or shock hazard,
humidifier,unpluQ humidifier, wher_’,:f
plug humidifier directly into a 120V, A.C. “…….. w’_a’fE_se”-“oalr”s””=.my,_’r,”when ”
electrical outlet. Do not use extension
the humidif._,L_Jt,i’ilv. _- ] -,,-.-..,-.
cords.
2. Keep the electric cord out of traffic areas. To reduce the risk of fire
haz-
9. To reduce the risk of accidental …… -cal_shock’;,’do’notloucITt_d
controls with wet hands.
elctri, or ‘ , ,”
ard, never put the electric cord under 10. Note the warning label shown below ·
rugs, near heat registers, radiators,
..—and on-the humidifier: ………….
stoves or heaters.
3. Always unplug the humidifier before moving it, removing the housing
section, before cleaning, or whenever the
WARNING: To reduce the risk of firs, electric shock, or injury always unplug before filling, servicing or cleaning.
II
Table’of Contents
Warranty Information ……………………….. 2
General Safety Instructions ………………. 2 To Save a Service Call ……………………… 2
Know Your Humidifier ………………………. 3
Humidifier Operations ………………………. 4
Assembly ………………………………………..
4
Location Instructions ……………………… 4-5
Electrical Hook-Up …………………………… 5
Water Fill ……………………………………..
5-6
Operating Humidifier Controls …………… 7 Using Your Humidifier ………………………. 8 Operating Tips for Best Performance…. 8 Replacement and Care of Filters …… 9-10 Cleaning of Humidifier ………………. 11-12 Trouble Shooting ……………………………. 13 Repair Parts …………………………….. 14-15
To Save a Service Call
Check following if your humidifier will not operate_ 1. Is power cord attached to outlet? 2. Is there electrical power to outlet?
3. Is airflow control in operating position? 4. Is humidity control set high enough? 5. Is the cabinet setting on a level surface?
Know Your Humidifier
Fill Light
Controls
Operating Light
Bottles
Filter Support
Filters Replacement Filter 42-t4911
Description
Gallon Output/24 Hrs. Capacity of Bottles Sq. Ft. Coverage Run Time Fan Speeds
Filters
Fill Light Water Level Indicator Auto Humidistat Controls
Operating Light U.L Listed AHAM Certified Volts Hertz Amps Watts
Control Panel Cover & Pivoting Lid Removed for Clarity
758.144533
13 2-3/8 Gallons 2700 48 Hours Variable
4 Yes Yes Yes Rotary Yes Yes Yes 120 A.C. 60
2.88 165
Each
Humidifier Operations
Your new Sears humidifier is designed to satisfy home humidity requirements
through the principle of evaporation of water into the air.
Humidified Air is Then Released
Through the Top
After water is added to the bottles, the fil-
ters begin to soak up the water and become totally saturated in approximately
30 minutes. Air is drawn in from
the rear of the humidifier, then passes through the filters by means of two
circulation fans. As air passes through the filters, moisture is absorbed into
the air and
then released through the top of the humidifier. This moist air is released in
the
Dry Air Enters ..:-; –:..”. Through the
Rear
form of vapor. No water droplets will enter the home. All evaporation into the
air takes place in the humidifier, which means that the residue left by
evaporating water is not passed into the home, but remains in the filter.
CAUTION: Use only 42-14900 EPA Registered Bacteriostat available from SEARS
Retail store. Under no circumstances should you use water treatment products
designed for Roto belt or Ultrasonic humidifiers.
Assembly
CAUTION: .Keep your humidifier clean. While humidifiers do not cause
colds, some studies suggest that dirty humidifiers can cause cold-like
symptoms in some people. To reduce the risk of this, we recommend you clean
your humidifier weekly with Humidifier Cleaner 42-14713 and use Bacteriostat
42-14900. These are
available at your local Sears store.
Your new Sears Kenmore humidifier is
instructions of this owner’s manual for
completely assembled for you to use. Remove the packaging material from inside your humidifier and follow the
proper usage. The packaging material is located under the fan assembly. Remove the packaging material and discard.
Location Instructions
WARNING: For your own safety, do not use humidifier if any parts are damaged or missing.
Icabinet) may not sense the water and the fill light will be on and the unit will not energize, if this happens, the unit will
Step I Place humidifier on a fiat level _urface in
need to be leveled in order for the humidifier to be energized.
area of house where most humidity is needed, or one which would likely result in moist air being circulated throughout the house such as near a cold air return.
NOTE: It may be necessary to purchase leveling coasters from your local hardware store. The coasters should be positioned under the front two casters of the humidifier.
P.lacing the unit level is very important if the humidifier is located on
carpeting.
NOTE: The 13 gallon humidifier contains water bottles, the weight of the
bottles in the front of the cabinet may sink the casters deeper in the carpet.
This will keep the wate_evel forward in the cabinet. The
Moist air (humidity) produced will disperse into the whole house, but area
closest to
unit will have the highest humidity. If the unit is positioned close to a
window, con-
densation may form on the window pane. If this is not appropriate the unit
should be repositioned in another location.
water level float (located at the rear of the
4
Location Instructions (continued)
NOTE: Due to release of cool, moist air from humidifier, it is best to direct
air away from home thermostat and hot air registers. It is best to position
humidifier next to an inside wall. Hot air registers and cold air from outside
walls can affect the efficiencies of the controls. Unit should not be placed
where warm air from a hot air register blows directly on unit.
Step 2 The humidifier should be positioned with the back (cord exit side), at
least 2 inches away from the wall. Air needs to enter through louvers in the
rear panel in order for the humidifier to operate at peak efficiency.
At Least 2″ From Wall
Electrical Hook-Up
Locate nearest 120V A.C. wall socket in the location desired, preferably on
inside wall. Plug in the electrical cord.
or shock hazard, humidifier should I bDeoARpnlNoutIgNgGues:de Teionxttoernedsaiuoc1ne20VtchoAerd.Csr.i.skouotflefti.re
Water Fill
WARNING: To reduce the risk Of shock, always unplug humidifier before filling, cleaning, or servicing.
Pivoting Lid Removed for Clarity
W’A]_I_ING: To reduce the risk of fire
or shock hazard, do not_pour or spill water into control or motor area. Close
the control cover. If controls
get wet, let them dry completely and have unit checked by authorized service
personnel before plugging in.
This humidifier is designed to be used with the two water bottles that are
located
under the pivoting lid. Op_the pivoting lid of the humidifier. Remove the
water bottles, lift them straight up and out of the cabinet.
5
Water Fill (continued)
Notice the water bottles are designed as right and left hand units. Position
them in the correct location so the humidifier can function properly. The
water bottles should rest in the front of the cabinet. Each “E-Z-Fill Side-
Cap” must be facing the rear of the unit.
Each water bottle is designed with an “E-Z-Fill Side-Cap” that is easily
removable. Remove the “E-Z-Fill Side-Cap” on the side of the water bottle by
twisting counterclockwise.
Rear of Humidifier
“E-Z-Fill Side-Cap” Should Always Face Rear
Turn Counterclockwise to Remove Cap
Place the opening of the water bottle under a water faucet (the bottle should
fit under a four-inch clearance faucet). Fill with recommended mixture of cold
water and Sears Bacteriostat #42-14900 only. Solid debris could make the valve
leak.
Install the “E-Z-Fill Side-Cap” by twisting clockwise. Hand tighten only.
Check for possible leaks by performing the following: 1. Grasp bottle handle
and hold the bottle
upright over a sink. 2. Press up on valve cap plunger for about
one second to let out a little water.
3. Release the plunger. 4. Listen for air bubbles. Look for leaks
around =E-Z-Fill Side-Cap”. 5. If you ear air bubbles or see leaks,
retighten “E-Z-Fill Side-Cap” and repeat steps 1-4. Wipe off excess water from
the bottle. Position the water bottle back into the unit. Grasp the water
bottle handle, and lower into the cabinet until the bottle sits on pads at
bottom of cabinet. The “E-Z-Fill Side-Cap” must be facing the rear of the
cabinet. When positioned properly, the plunger will open and water will flow
into the cabinet. The water level will automati-
cally re at approximately 1/2″ until the bottles are empty. The unit is now
ready for operation.
‘ Valve Cap Plunger
Pivoting Lid Removed ) / for Clari_
°
6
Operating Humidifier Controls
The operating controls of your Kenmore Quiet Comfort Whole House humidifier
are located on the top center of the humidifier. The controls are found under
the smoked cover, located between the air circulating fans. Lift the control
cover by placing your finger in the round cutout and lifting. The cover will
stay open. Now you can clearly see the control area. Familiarize yourself with
the controls and reference the dia-
gram of the control area for the correct naming used in this manual.
Fan Control
Your Kenmore Quiet Comfort Whole House humidifier allows a choice to be
made for single or dual fan control. The slide switch allows one or two fans
to be
used. Slide the switch to the “1” position to operate one fan and the “2°
position to operate both fans. The benefits of two fans and two control
settings to the customer are summed up in the name, “QUIET COMFORT WHOLE HOUSE
HUMIDIFIER”. The “FAN” slide
To Operate the Controls Humidity Control:
Adjust the amount of humidity depending on your needs. The humidifier will
turn on and off as required to maintain level of humidity selected. MEDIUM
setting is recommended, but there are times when low or high amount of
humidity may be preferred. For constant operation of humiditier, MAX allows
for the maximum amount of humidity to be evaporated into the air continuously.
IMPORTANT: Water damage may result if condensation starts to form on windows
switch, positioned in the #1 position will operate the humidifier with one fan
only in any speed position and provides reduced output at a lower noise level.
The “FAN” slide switch positioned in the #2 setting will operate the
humidifier with both fans and provides greater output than the single fan
settings. Maximum output is provided by the humidifier in the #2 position with
the speed control set at high. This allows an infinite number of fan/speed
settings, to determine the noise level and out _ut level that best suits you.
QuietComfort13
or walls. Humidity Control setting should
be lowered until condensation no longer
forms.
HUMIDITYM_
Power Light
MAX
When the unit is turned on, the power light
will come on. It will stay on until the unit is turned off or unplugged.
Fill ‘t:i lht
When the unit has a small amount of
OFF SPEED
water left in it, the fill light will come on
LOW
and the unit will automatically shut off.
Speed Control
The unit is adjusted from “OFF” to high to low with a variable speed control. The higher the air flow speed, the more water is evaporated and released into the air. Low speed is the quietest and is provided for conditions that may not require as.l_jh an evaporation rate.
POWER FANS
7
Using Your Humidifier
Step 1 Be sure unit is full of water and plugged in.
Step 2 Set the Fan selection switch to “2”. This will allow both fans to
operate if the humidistat senses humidity is needed.
Step 3 Set speed control to low.
Step 4 Set Humidity Control to medium position.
NOTE: Humidifier should operate with humidity control on the recommended
MEDIUM setting. If it does not, the humidity is at a relatively high level. To
test the unit under this condition, turn Humidity Control all the way to MAX
and unit should begin to operate. After unit has been tested, set Humidity
Control to MEDIUM or desired level.
Step 5
If humidifier stops running, the humidity level is at the normal requirements
for that setting or it is adjusting to the home conditions. The table below
shows approximate relative humidity percentages which correspond to the
various settings of the Humidity Control.
When Outdoor Temperature is:
Recommended Indoor Relative
Humidity is:
-10°F 0°F 10°F
20°F & above
20% 25% 30%
35%
Allow 24 hours for humidifier to adjust.
If humidity level in home is sufficient, the humidifier will only operate with
Humidity Control set on maximum.
IMPORTANT: Water damage may result if condensation starts to form on windows
or walls. Humidity Control setting should be lowered until condensation no
longer forms.
HUMIDITY MIN
MAX
Operating Tips for Best Performance
1. Position the humidifier at least 2 inches
from-a_y_vall and away from any heat registers.
2. Do not restrict airflow from entering or exiting the humidifier.
3. Use Sears recommended bacteriostat
42-14900 to retard bacteria growth that may cause odors and may be harmful to
your health.
4. Regular cleaning as instructed in “Cleaning of Humidifier” section of this
manual is recommended.
5. Replacement of the evaporative wicking filter at least once per
humidification season or more depending on water conditions in your area.
8
Replacement and Care of Filters
shock or injury from moving parts, always unplug humidifier J
WbeAfoRrNeINGre:movTiongreduocrerepthlaecinrgisk aonf y parts.
CAUTION: To help retard bacteria growth and keep maximum efficiency, the
filters should be replaced at least once a season, or more often under hard
water conditions. Use Sears recommended
replacement filter.
All filters may be rinsed in clear water only. Take care not to damage paper.
To replace the evaporative wicking filters in your Kenmore Quiet Comfort Whole
House humidifier, follow the instructions below. 1. Unplug humidifier, and
proceed to
clean. Before removing the filters, we recommend moving the humidifier to an
area where floor coverings are not susceptible to water damage, i.e. kitchen
or bath areas. 2. Open the pivoting lid and remove water bottles and set
aside. Grasp the fan assembly front center and rear center. Lift off and set
aside on a clean fiat surface. The filter assemblies are now accessible..
3. Lift filter housings out of cabinet and place where you may work on them
comfortably. With a soft, absorbent
clo_ remove any remaining water or loose mineral deposits not trapped in the
filter from the humidifier cabinet.
4. To open filter housing for easy access to filters: a. Deflect the two
spring tabs on top of filter housing. Lift top cover off of the filter housing
and set aside. b. Remove the two filters and dispose of properly. Clean
internal parts of humidifier per the “Cleaning of Humidifier” section of your
owner’s manual.
Spring Tabs
9
Replacement and Care of Filters (continued)
c. Install new tilters in the tilter housing track with the glue beads of the
wicking pad to the inside of the filter housing.
d. Return the top cover of the filter housing by installing the cover over the
fixed tabs on the rear of the
lower tilter housing and pivoting the cover down over the top of the filters.
Snap the cover over the two spring tabs. e. Replace the tilter housing in the
cabinet. Note: There is a left and a
right tilter housing. There is also a front and back orientation. To position
the filter housings correctly:
· Make sure the two indents in the cylinder section of the top covers are
positioned towards the center of the cabinet.
· Be sure that the spring tabs of fil-
ter housings are towards front of cabinet.
· Align the lower portion of the filter assembly over the six ribs located at
the bottom rear of the humiditier cabinet.
fo Position fan assembly onto the cabinet. Make sure the fan venturi (lowest
cylinder section below the fan) is placed inside the tilter housing.
g. Replace water bottles. h. Close the pivoting lid on the fan
assembly. i. The unit is ready for use or to be
“stored away for next season. NOTE: For correct operation of the filter
housing assembly, tilters n_ust be fully contained inside the flange of the
top cover.
Spring Tabs
Fixed Tabs
Filter
Front of Humidifier
Top Cover
Rear of
Indents Towards Center
Cabinet
Flat Portion of Filter Housing Towards Back of Cabinet
Indents Toward Center of Cabinet Step 4.e.
1o
Cleaning of Humidifier
CAUTION: To reduce the risk of
injury, fire or damage to humidifier, use only cleaners specifically
recommended for humidifiers. Never
use flammable, combustible or poisonous materials to clean your humidifier. To
reduce the risk of
scalds and damage to humidifier, never put hot water in humidifier.
CAUTION: Local water purity may vary from area to area and under certain
conditions water impurities and airborne bacteria may promote the growth of
microorganisms in the reservoir of a humidifier.
To retard bacteria growth that may cause odors and be harmful to your health,
use only Sears replacement filters. We also recommend using a EPA approved
bacteriostat, 42-14900 and humidifier cleaner 42-14713, available at your
local Sears store.
Step 2
To Remove Parts
a. Raise pivoting lid, remove the fan assembly which contains the motors and
fans, and set aside. (See Repair Parts list.)
b. Remove the water bottles from the cab-
inet and remove the filter housings (see “Repair Parts” list for
identification).
c. Lift the filter housing assemblies out of the cabinet and set to the side.
Before removing the internal parts of the humidifier cabinet, we recommend
moving the humidifier to an area where floor coverings are not susceptible to
water damage, i.e., kitchen or bath area.
d. Remove the water level float from the humidifier cabinet. The cabinet
should
be empty and the water reservoir is ready for cleaning. The water reservoir
consists of the lower areas of the humidifier cabinet where the float filters
NOTE: If it is necessary to use approved bacteriostat, follow the directions
correctly. The bottles of the whole house humidifier will hold 2-3/8 gallons
of water each. Step 1
To make cleaning easier, the water reservoir should be empty and completely
dried out. To accomplish this, use the following method: a. Allow the
humidifier to run until the
autor0_atic shutoff turns the humidifier “OFF”.
are during normal operation time.
e. Empty Cabinet.
f. Proceed to °Bi-Weekly Maintenance” or “End of Season Maintenance”.
g. Remove old filters and dispose of properly. Continue to clean cabinet and
internal parts as described on next page.
Step 3 Install new filters (purchase the correct evaporative wicking filter
pads 42-14911 for your humidifier) into the location where the old filters
were positioned. Install the
b. Unplug humidifier
WARNING: If humidifier is not unplugged, fan could start after housing is
removed.
c. Follow instructions in step 2 below “To Remove Pads”.
d. After removing the parts, dry out the bottom of the humidifier cabinet.
filter housings with the new filters into the correct location. Position the
fan assembly
II on top of the cabinet and return the humidifier to the desired location for
use.
Refill humidifier bottles with fresh cool water and return them to the
cabinet. Plug the unit into a 120 volt A.C. power outlet and set the controls
per the “Operating Humidifier Controls” section of this manual.
e. Proceed to “Bi-Weekly Maintenance” or “End_of Season Maintenance”.
11
Cleaning of Humidifier (continued)
Bi-Weekly Maintenance
Removing Scale
1. Fill the water reservoir with one 8 oz. cup of undiluted white vinegar.
Let solution stay 20 minutes.
2. Clean all interior surfaces with soft brush. Dampen soft cloth with
undiluted white vinegar and wipe out the water reservoir to remove scale.
3. Rinse thoroughly with clean warm water to remove scale and cleaning
solution before disinfecting the water reservoir.
4. Dust the fan assembly and outside surfaces with a soft cloth only.
Disinfecting
and Base
Water Reservoir
2. Empty water reservoir after 20 minutes. Rinse with water until bleach
smell is gone. Allow unit to dry out completely.
3. Water bottles should be cleaned in same manner.
End of Season Maintenance
1, Follow bi-weekly maintenance instructions at end of humidification season
or when humidifier will not be used for at least one week or more.
2. Remove and throw away filters.
3. Let humidifier dry completely before storing. Do not store with water
inside cabinet or water bottles.
4. Store in cool, dry location. 5. Install new filters in clean humidifier
before next season begins.
1. Fill water reservoir with 1 teaspoon chlorine bleach in 1 gallon water. Let solution stay 20 minutes, swishing every few minutes. Wet all surfaces normally exposed to water.
12
Troubleshooting
Trouble
Probable Cause
Remedy
Unit will not run.
· Humidity level is too high · No power
Unit will not shut off. · Float is not free
· Raise humidistat setting · Check 120 volt power source
· Free float from obstruction
Unit will not dry out completely
I Bottles continue to empty.
· Water is present in the system
· High humidity or low temperature resulting in slow evaporation
· This is normal. A small amount of water remains in the cabinet.
· Allow unit to continue operation.
· Air is entering water reservoirs.
· Check “E-Z-Fill Side-Caps” to ensure tightness.
· Check for leak in water bottles.
· Are gaskets for “E-Z-Fill SideCaps” in place (see repair parts list).
Unit is not emptying.
· Dirty filter · Reservoir cap plunger
missing post in bottom of cabinet.
Unit runs and shuts ! · Humidity level is too high off before bottles are
empty
· Unit is not setup on a level
surface (Float will not sense water at the rear of the cabinet.
· Change to a fresh new filter. · Check orientation of bottle.
Reposition so that reservoir cap plunger is depressed by post in bottom of
cabinet.
· Raise humidistat setting (if possible)
· Position unit level (Some carpet padding may allow unit to set lower in the
front than the
rear with the additional weight of water bottles in the front of the cabinet.
Install coasters under front casters.
CAUTION: Use only 42-14900 EPA Registered Bactedostat available from Sears
Retail store.
Use of other water treatment products may damage the filter elements. Under no
circumstances should you use water treatment products designed for Roto belt
or Ultrasonic humidifiers.
13
,lb.
Parts List For Sears Humidifiers Model No. 758.144533
Key
t;
No.
Part No.
Ddscription
1 823884
Cover Dust
2 823730 3 823724-1 4 826544-1
Lid Stationary Lid Pivoting Knob
5 824117-1
Cap
6 826546
Label Control
7 826400
Cover Control
8 823910
Switch Slide
9 824691-2
Switch Variable Speed w/Off
10 825858
Light
ol
11 13805-02
Humidistat
12 823728
Switch Micro
13 826401
Enclosure Electronics
14 824101-1
Retainer Float
15 823712
Float Water Level
16 824690 17 824689
“E-Z-Fill Side-Cap” Bottle Left
18 824688 19 819024
Bottle Right Seal Valve
20 826011
Seal Cap
*Standard Hardware Item – May be purchased locally
Key
No,
Part No.
21 822419-2 22 819026 23 819027 24 823710-2 25 823726 26 STD601107 27 822120 28 823849 29 42-14911 , 30 823977 31 825918 32 823735 33 822405-7 34 822406-1 35 816069-2 36 822405-5 37 823714 38 825919 — SP6167
De
Cap Spring Valv Stem Valve Cabinet Rail Kick
- Scr, Pan Hd Caster Twin
Support Fil t Filter Evapo
Support Fil Gasket Foa
Support Mo Motor Fan Scr Pan Hd Motor Support Filte Cord w/Plug Owners Man
t Stock item – May be secured thr Department of most SearF retail sto
Forthe repair or replacementpartsyou need Call7 am – 7 pmo7 days a week
1-800-366-PART
(1-800-366-7278)
For in-homemajor brandrepairservice (;all 24 hoursa day, 7 daysa week
1-800-4-REPAIR
(1-800-473-7247)
Forthe locationof a
Sears RepairService Centerin yourarea Call 24 hoursa day, 7 daysa week
1-800-488-1222
For informationon purchasinga Sears MaintenanceAgreementor to inquire
about an existingAgreement Call 9 am – 5 pro, Monday-Saturday
1-800-827-6655
SEARS
The model label.
America’s Repair Specialists
number will be found
on the Humidifier
identification
When requesting service or ordering parts, always provide the following information:
· Product Type · Part Number
· Model Number · Part Description
© 19″_J_Emerson Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
Part No. SP6167
Form No SP6167
Printed in Canada 6/98
References
- Repair Your Grill: Shop Replacement Parts for 24,880 Models
- Kenmore Humidifier Parts - Select From 496 Models
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>