SupplyHouse TSC060G4R0A001S Blower Control Panel Instruction Manual

July 8, 2024
SupplyHouse

TOP LEVEL FOR TSC060G4R0A001S
Parts List Number :TSCUP9
Model Number :TSC060G4R0A001S

REV A

PACKAGED COOLING / HEAT PUMP               75011213

The sections that appear on this illustration are for all options.
Sections and options will appear in the Parts List if ordered with the unit.

  1. Cabinet
  2. Blower
  3. Fan
  4. Controls
  5. Through the Base
  6. Refrigeration
  7. Heat
  8. Indoor
  9. Air Handling

This is a typical illustration. The unit in the field may not appear exactly as shown.

Part No.

| Reference No.| Quantity| Description
---|---|---|---
75011208|

2

| | BLOWER

75011210

|

3

| | FAN

75011226

|

4

| | CONTROL PANEL

75010620

|

6

| | OUTDOOR AIR SENSOR

75011206

|

6

| | REFRIGERATION – COMPRESSOR, INDOOR/OUTDOOR COILS, FILTERS

OPTIONS

|

10

| | OPTIONAL FIELD INSTALLED ACCESSORIES

75011255

|

11

| | MODEL NUMBER DESCRIPTION, DIGITS 1-17

75011256

|

11

| | MODEL NUMBER DESCRIPTION, DIGITS 18-31

75011257

|

11

| | MODEL NUMBER NOTES

BLOWER
Parts List Number :TSCUP9
Model Number -TSCO60G4R0A001S

REV A

BLOWER

75011208

This is a typical illustration. The unit in the field may not appear exactly as shown.

Part No.

| Reference No.| Quantity| Description
---|---|---|---
SCR01623| *|

17

| SCREW; SHEET METAL, 10-16 UNC X 1/2, HIGH TORQUE, INDENT HEX-WASHER HEAD

BRK03657

| 2|

4

| BRACKET; MOTOR ARM, INCLUDES GROMMET. (CONTAINS A QTY OF 4 BRACKETS)

NUT00355

| 2|

4

| NUT; HEX, LOCK, 5/16IN.-18

NUT00446

| 3|

1

| NUT; 0.31-18, HEX FLANGE-LOCK

BRK03232

| 4|

1

| BRACKET; MOTOR MOUNTING, 17.6 LENGTH (4 LEG)

WHL02168

| 5|

1

| WHEEL; FAN, 11.87 DIA X 11.93 W, .50 BORE, CCW, CONCAVE. INCLUDES 5/16-18 X 1/2 INCH SQH CUP PT SET SCREW.

ORF01304

| 6|

1

| ORIFICE; INLET RING, 10.38 ID

BUS00485

| 7|

1

| BUSHING; .62 MTG W/MAX .44 ID

HUS03676

| 8|

1

| HOUSING; BLOWER, 11 X 11

BRK04715

| 9|

1

| BRACKET; INDOOR FAN, 22.00L X 0.90W X 0.50H

BRK04716

| 10|

1

| BRACKET; FAN ACCESS PANEL, 17.13L X 3.16W X 1.0H

PNL33591

| 11|

1

| PANEL; HEAT WRAPPER, 42.23L X 19.00W X 19.25H, 14.63 X 12.18 OPENING

FAN
Parts List Number :TSCUP9
Model Number :TSC060G4R0A001S

REV A

FAN

75011210

This is a typical illustration. The unit in the field may not appear exactly as shown.

Part No.

| Reference No.| Quantity| Description
---|---|---|---
FAN05568| 1|

1

| PROPELLER; OD FAN – 22 INCH 3 BLADES

MOT17291

| 2|

1

| MOTOR; 3 PHASE 0.4 HP 460

GRL01332

| 3|

1

| GRILLE; FAN, 26.65 MTG HOLE DIAMETER

IRT00017

| 4|

4

| INSERT; BUMPER-STOP, 0.468 OD X 0.81 LG, BLACK RUBBER

NUT00845

| 5|

4

| NUT; FLANGE NIBBED

SCR01623

| 6|

4

| SCREW; SHEET METAL, 10-16 UNC X 1/2, HIGH TORQUE, INDENT HEX-WASHER HEAD

CONTROL PANEL
Parts List Number :TSCUP9
Model Number :TSC060G4R0A001S

REV A

CONTROL PANEL

75011226

The parts that appear on this illustration are for all options.
Parts will appear in the Parts List if ordered with the unit.

This is a typical illustration. The unit in the field may not appear exactly as shown.

Part No.

| Reference No.| Quantity| Description
---|---|---|---
WIR03230| *|

1

| WIRE; HARNESS, CRANKCASE HEATER, W/CTL

WIR08183

| 1|

1

| WIRE; HARNESS, POWER, CONTROLS TO IDM

RLY03065

| 2|

1

| RELAY; DPDT, 5 AMPS AT 120/277 VAC, 24 VAC COIL, 750 RMS, COIL CLASS F

CTR01826

| 6|

1

| CONTACTOR; 3 POLE, 30 FLA, 24 VAC COIL, WITH LUGS

CON00077

| 7|

1

| CONNECTOR, ELECTRIC GROUND, 14-2 AWG SOLDERLESS

CNT01405

| 8|

1

| CONTROL; TEMP, OPEN 65F, CLOSE 55F, SPST

CNT05176

| 9|

1

| CONTROL; MONITOR, 3-PHASE LINE, UNIVERSAL 180-632 VAC, PHASE AND LOSS REVERSAL

TRR00826

| 10|

1

| TRANSFORMER; 75 VA, 460-575V PRI, 24V SEC

CAT00043

| 11|

2

| CATCH; MAGNETIC SNAP-IN

TER01680

| 13|

1

| TERMINAL STRIP; .25IN. FASTON

MOD02668

| 14|

1

| MODULE; RELIATEL REFRIG DUAL CIRCUIT COOL/HP

BLK00940

| 15|

1

| BLOCK; 6 TERMINALS (LVTB)

WIR08174

| 16|

1

| WIRE; HARNESS, CONTROLS. INCLUDES BLK00940, SEN02929, TER01680 & WIR08179

OUTDOOR AIR SENSOR
Parts List Number :TSCUP9
Model Number :TSC060G4R0A001S

REV A

OUTDOOR AIR SENSOR                                       75010620

TYPICAL ILLUSTRATION

Part No.

| Reference No.| Quantity| Description
---|---|---|---
SCR01623| *|

4

| SCREW; SHEET METAL, 10-16 UNC X 1/2, HIGH TORQUE, INDENT HEX-WASHER HEAD

SEN00275

| 1|

1

| SENSOR; THERMISTOR PROBE, -40 DEG C TO 65 DEG C, 12 INCH STRIPPED LEADS

GRM00039

| 2|

1

| GROMMET; RUBBER .25 ID X .05 GRV MLD

BRK04441

| 3|

1

| BRACKET; OUTDOOR AIR SENSOR

REFRIGERATION – COMPRESSOR, INDOOR/OUTDOOR COILS, FILTERS
Parts List Number :TSCUP9
Model Number :TSC060G4R0A001S

REV A

REFRIGERATION

75011206

This is a typical illustration. The unit in the field may not appear exactly as shown.

Part No.

| Reference No.| Quantity| Description
---|---|---|---
BOF02425| *|

1

| BLOCKOFF; ID COIL TOP

BOF02426

| *|

1

| BLOCKOFF; ID COIL – BOTTOM

HTR03436

| *|

1

| HEATER; CRANKCASE 6.5 DIA, 40W, 575V, 45 INCH LEADS (32W AT 460V)

TOL05032

| *|

1

| TOOL; FILTER REMOVAL

WIR03227

| *|

1

| WIRE; PLUG, 30 IN LENGTH, FOR 230/60/3 OR 460/60/3 OR 575/60/3 SCROLL COMPRESSOR (RD,BL,BK WIRES)

BRK03274

| 1|

4

| BRACKET; BASE SUPPORT MOUNT, 10.3 LENGTH (FORKLIFT BRACKET)

PLT04187

| 2|

1

| PLATE; COMPRESSOR MOUNTING, 17.0 X 11.0

ISR00007

| 3|

4

| ISOLATOR; VIBRATION

NUT00355

| 3|

4

| NUT; HEX, LOCK, 5/16IN.-18

COM10211

| 4|

1

| COMPRESSOR; SCROLL; ALLIANCE; SXA049B4BPA, 4 TON, 460V/60/3, STUB TUBE, R-410A

COR00006

| 5|

1

| CORE; VALVE PORT, .79 LENGTH, .206-36 UNS 2A THD

VAL01483

| 5|

1

| VALVE; BODY, .44-20 THD X .25 ODS, STRAIGHT, BRASS, LESS CORE

ANG01323

| 6|

1

| ANGLE; TOGGLE LOCK, 41.93 X 1.80

DHY01511

| 7|

1

| DRIER; FILTER, LIQUID LINE, 5/16 ODM INLET X 5/16 ODF OUTLET, 8 CU INCH

RAL00873

| 10|

1

| RAIL; BASE, 69.8 X 44.2 (3 SIDES,U SHAPED)

RAL00874

| 11|

1

| RAIL; END, 44.0 LENGTH

COL25999

| 13|

1

| COIL; ASSEMBLY; INDOOR COIL, MC

VAL12335

| 14|

1

| VALVE; EXPANSION; TR6 5T

PAN03947

| 15|

1

| PAN; DRAIN, CONDENSATE REMOVAL, 39.47 L, ATTACHES TO BOTTOM OF THE ID COIL

CAP00072

| 16|

1

| CAP; VALVE, SEAL, .25 FFL

SET00819

| 16|

1

| SEAT; SADDLE MOUNT ASSEMBLY

STM00803

| 16|

1

| STEM; SADDLE MOUNT, VALVE CORE, BRASS, .344 DIA X 1.29 SCHRAEDER TYPE FITTING (TO INCLUDE 5 PIECES)

SWT03623

| 17|

1

| SWITCH; LOW PRESSURE CUTOUT, 250 OPEN, ACTUATION PRESSURE 55 +/- 5, RESET PRESSURE 35 +/- 5

WIR04406

| 17|

1

| WIRE; HARNESS, LOW PRESSURE SWITCH, 42 IN LENGTH, BLUE WIRES, CIR 1

THT02805

| 18|

1

| THERMOSTAT; WITH CLIP, .5/.625 TUBE, 38 IN, BLACK WIRES, SPST, 230F OPEN, 180F CLOSE

CAP00072

| 19|

1

| CAP; VALVE, SEAL, .25 FFL

SET00819

| 19|

1

| SEAT; SADDLE MOUNT ASSEMBLY

STM00803

| 19|

1

| STEM; SADDLE MOUNT, VALVE CORE, BRASS, .344 DIA X 1.29 SCHRAEDER TYPE FITTING (TO INCLUDE 5 PIECES)

SWT03398

| 20|

1

| SWITCH; HIGH PRESSURE, BRAZED, OPENS AT 650 PSIG, CLOSES AT 550 PSIG, 36 INCH WHITE LEADS

OPTIONAL FIELD INSTALLED ACCESSORIES

Parts List Number :TSCUP9
Model Number :TSC060G4R0A001S

Part No.

| Reference No.| Quantity| Description
---|---|---|---
BAYGARD137A| *|

1

| ACCY; PRECEDENT HAIL GUARD

BAYHTRE406C

| *|

1

| 6.0 KW/460/3/60 HEATER

BAYHTRE412C

| *|

1

| 12.0 KW/460/3/60 HEATER

BAYHTRE418C

| *|

1

| 17.4 KW/460/3/60 HEATER

BAYHTRE423C

| *|

1

| HEATER; 23.0 KW/460/3/60 HEATER

BAYLMSW001A

| *|

1

| POWER EXHAUST LIMIT SWITCH

BAYLOAM120A

| *|

1

| KIT; EVAPORATOR DEFROST, CLIP-ON, RELIATEL

BAYPWRX071A

| *|

1

| POWER EXHAUST, 460V, FOR 3-5 TON T/W/YSC, D/T/W/YHC, T/YZC

BAYRTEM001A

| *|

1

| RELIATEL ECONOMIZER LOGIC MODULE

BAYTUBE105A

| *|

1

| KIT; DISCHARGE AIR SENSING, ELECTRIC HEAT, F CAB

BRD03177

| *|

1

| RELIATEL COMMUNICATION INTERFACE; COMM3 & 4 PACKAGE UNITS (BAYICSI003AD) RTCI – FIELD KIT

CRB00170

| *|

1

| CURB; ADAPTA CURB (BAYQACB009AA), TRANSITIONS BAYCURB021B, 78.125 X 43.875

CRB00171

| *|

1

| CURB; ADAPTA CURB (BAYQACB010AA), TRANSITIONS BAYCURB022B, 77.625 X 46.875

CRB00175

| *|

1

| CURB; ROOFCURB (BAYCURB042AB)

DMP02175

| *|

1

| DAMPER; 0-50% MANUAL OUTSIDE AIR DAMPER (BAYDMPR053BA)

DMP02839

| *|

1

| DAMPER; BAROMETRIC RELIEF (BAYBARM010AB)

DMP02956

| *|

1

| DAMPER; RELIATEL, 0-50 PERCENT MOTORIZED OUTSIDE AIR DAMPER (BAYDMPR051A)

ECN00122

| *|

1

| ECONOMIZER; RELIATEL, 0-100% DRY BULB (BAYECON085A)

KIT09433

| *|

1

| KIT; ACCESSORY, OPTIONS BOARD (BAYABRD001CA)

KIT09500

| *|

1

| LCIR W/ SHORT HARNESS 3-10 TON PACKAGE UNITS (HARNESS = WIR03458) LCI-R SHORT KIT

KIT13704

| *|

1

| KIT; FAN FAILURE SWITCH (BAYDFPS004AB). (OPTIONS BOARD KIT09433-BAYABRD001CA MUST BE INSTALLED IN THE UNIT FOR THIS ACCESSORY TO OPERATE).

KIT13711

| *|

1

| KIT; VENTILATION OVERIDE (BAYVNOR001BB) (OPTIONS BOARD KIT09433-BAYABRD001CA MUST BE INSTALLED IN THE UNIT FOR THIS ACCESSORY TO OPERATE).

KIT15159

| *|

1

| KIT; CO2 SENSING (BAYCO2K001B)

KIT15160

| *|

1

| KIT; CO2 DEMAND-CONTROLLED VENTILATION DUCT SENSOR (BAYCO2K003B)

KIT15161

| *|

1

| KIT; REFERENCE ENTHALPY (BAYENTH005A)

KIT15162

| *|

1

| KIT; COMPARATIVE ENTHALPY (BAYENTH006B)

KIT15864

| *|

1

| KIT; BACNET COMMUNICATION INTERFACE, RELIATEL (BCI-R KIT FIELD INSTALLATION KIT) (BABCIR001A)

PLT04561

| *|

1

| PLATE; WALL COVER PLATE ASSEMBLY (BAYMTPL110A)

SEN00278

| *|

1

| SENSOR; THERMISTOR PROBE, -40 DEG C TO 65 DEG, STRIPPED LEADS (BAYSENS016AA)

SEN00435

| *|

1

| SENSOR; ZONE LEVEL 4 (BAYSENS017BB) REMOTE ROOM SENSOR

SEN00496

| *|

1

| SENSOR; ZONE LEVEL 4 (TRANE). (BAYSENS014CA) ROOM SENSOR W/ TEMP. ADJUSTMENT WITH OVERRIDE AND CANCEL BUTTONS

SEN01447

| *|

1

| SENSOR; ZONE, ROOM SENSOR W/TEMP. ADJUSTMENT WITH OVERRIDE AND CANCEL BUTTONS, 10K, DIAL, OCCUPIED (BAYSENS074AA)

SEN01448

| *|

1

| SENSOR; ZONE, REMOTE ROOM SENSOR, 10K (BAYSENS077AA)

SEN01450

| *|

1

| SENSOR; ZONE, ROOM SENSOR W/ OVERRIDE AND CANCEL BUTTONS, 10K, OCCUPIED (BAYSENS073AA)

SEN01513

| *|

1

| SENSOR; ZONE; DUAL SETPOINT MANUAL OR AUTO CHANGOVER, TWO SET FAN SYSTEM (BAYSENS108AA)

SEN01515

| *|

1

| SENSOR;ZONE SINGLE SETPOINT MANUAL CHANGEOVER, SET FAN SYSTEM, COOL/OFF/HEAT (BAYSENS106A)

SEN01522

| *|

1

| SENSOR; ZONE, DUAL SETPOINT MANUAL OR AUTO CHANGEOVER W/SYSTEM FUNCTION LIGHTS TWO SET FAN SYSTEM, LED (BAYSENS110A)

SEN01577

| *|

1

| SENSOR; PROGRAMMABLE ZONE, AUTOMATIC OR MANUAL CHANGEOVER W/ SYSTEM LIGHTS TRANE (BAYSENS119AA)

SEN01579

| *|

1

| SENSOR; CO2 SENSING KIT; WALL MOUNTED (ASYSTAT712B)

SEN01580

| *|

1

| SENSOR; CO2 SENSING KIT; DUCT MOUNTED (ASYSTAT714B)

SEN01665

| *|

1

| SENSOR; DUAL SETPOINT, W/FAN CONTROL – AUTO/HIGH (BAYSENS135A)

THT00839

| *|

1

| THERMOSTAT; REMOTE POTENTIOMETER, 60-90 DEG F (BAYSTAT023AA)

THT02239

| *|

1

| THERMOSTAT; HIGH TEMPERATURE (BAYFRST001AA)

TOL00099

| *|

1

| TOOL; RESISTANCE DECADE BOX

MODEL NUMBER NOTES
Parts List Number :TSCUP9
Model Number :TSC060G4R0A001S

REV A

MODEL NUMBER NOTES                                     75011257

Precedent Cooling and Gas/Electric

Example Model Number:

Model Number Notes.

(1) Manual outside air damper will ship factory supplied within the unit, but must be field installed

(2) Economizer with Barometric Relief is for downflow configured units only. Order Economizer without Barometric Relief for horizontal configuration. Barometric Relief for horizontal configured units must be ordered as a field installed accessory.

(3) Not available with Electromechanical controls.

(4) Epoxy coil and epoxy with hailguard option not available for units with microchannel Coils.

(5) Through the base electric required when ordering disconnect/circuit breaker options.

(6) Includes gas piping and shutoff (field assembly required). Digits 18=B,C applicable to Digit 1, Y models only.

(7) Requires use of Disconnect or Circuit Breaker.

(8) Standard metering devices are TXVs.

(9) High pressure control is standard on all units

(10) Frostat™ cannot be field installed in electromechanical units. Frostat ™ is standard an Y/TSC033 to 063G electromechanical units.

(11) Not available with high temperature duct sensor accessory.

(12) The return air smoke detector may not fit up or work properly on the Precedent units when used in conjunction with 3rd party accessories such as bolt on heat wheels, economizers and power exhaust. Do not order the return air smoke detectors when using this type of accessory.

(13) Return air smoke detector cannot be ordered with Novar controls.

(14) The Clogged Filter Switch, Fan Failure Switch and Discharge Air Sensing Tube are standard when ordering Novar controls.

(15) The Clogged Filter Switch, Fan Failure Switch and Discharge Air Sensing Tube are ordering Novar controls.

(16) Novar sensor utilized with 21=(4) Novar 3051 controls without zone sensor.

(17) Demand Control Ventilation Option includes wiring only. The CO2 sensor is a field-installed only option.

MODEL NUMBER DESCRIPTION, DIGITS 18-31
Parts List Number :TSCUP9
Model Number :TSC060G4R0A001S

REV A

MODEL NUMBER DESCRIPTION                       75011256

Precedent Cooling and Gas/Electric

Example Model Number

Digit 18 – Through the Base Provisions
0 = No Through-the-Base Provisions
A = Through-the-Base Electric (5)
B = Through-the-Base Gas Piping (6)
C = Through-the-Base Electric and Gas Piping (6)

Digit 19 – Disconnect/Circuit Breaker
0 = No Disconnect/No Circuit Breaker
1 = Unit Mounted Non-Fused Disconnect (5)
2 = Unit Mounted Circuit Breaker (5)

Digit 20 – Convenience Outlet
0 = Convenience Outlet
A = Unpowered Convenience Outlet
B = Powered Convenience Outlet (7)

Digit 21 – Communications Options (3)
0 = No Communications Interface
1 = Trane® Communications Interface
2 = LonTalk® Communications Interface
3 = Novar 2024 Controls
4 = Novar 3051 Controls without Zone Sensor
5 = Novar 3051 Controls Interface with DCV
6 = BACnet® Communications Interface
7 = Wireless Building Automation Control Network Communications Interface

Digit 22 – Refrigeration System Option
0 = Standard Refrigeration System (8)

Digit 23 – Refrigeration Controls
0 = Without Refrigeration Controls (9)
1 = Frostat ™ (10)
2 = Crankcase Heater
3 = Frostat ™ (10) and Crankcase Heater

Digit 24 – Smoke Detector (11)
0 = No Smoke Detector
A= Return Air Smoke Detector (12,13)
B = Supply Air Smoke Detector
C = Supply and Return Air Smoke Detectors (12,13)
D = Plenum Smoke Detector

Digit 25 – System Monitoring Controls (14)
0 = No Monitoring System
1 = Clogged Filter Switch
2 = Fan Failure Switch
3 = Discharge Air Sensing Tube
4 = Clogged Filter Switch and Fan Failure Switch
5 = Clogged Filter Switch and Discharge Air Sensing Tube
6 = Fan Failure Switch and Discharge Air Sensing Tube
7 = Clogged Filter Switch, Fan Failure Switch and Discharge Air Sensing Tube
8 = Novar Return Air Sensor (NOVAR 2024) (15)
9 = Novar Zone Temp Sensor (NOVAR 3051) (16)
A = Condensate Drain Pan Overflow Switch
B = Clogged Filter Switch and Condensate Drain Pan Overflow Switch
C = Fan Failure Switch and Condensate Drain Pan Overflow Switch
D = Discharge Air Sensing and Condensate Drain Pan Overflow Switch
E = Clogged Filter Switch, Fan Failure Switch, and Condensate Drain Pan Overflow Switch
F = Clogged Filter Switch, Discharge Air Sensing, and Condensate Drain Pan Overflow Switch
G = Fan Failure Switch, Discharge Air Sensing and Condensate Drain Pan Overflow Switch
H = Clogged Filter Switch, Fan Failure Switch, Discharge Air Sensing, and Condensate Drain Pan Overflow Switch

Digit 26 – System Monitoring Controls
0 = No Monitoring Controls
A = Demand Control Ventilation (CO 2) (17)
B = Low Leak Economizer with FDD (Fault Detection & Diagnostics)
C = FDD (Fault Detection & Diagnostics) with DCV (Demand Control Ventilation)

Digits 27 – Unit Hardware Enhancements
0 = No Enhancements
1 = Stainless Steel Drain Pan

Digit 31 – Advanced Unit Controls
0 = Standard Unit Controls
1 = Human Interface

MODEL NUMBER DESCRIPTION, DIGITS 1-17
Parts List Number :TSCUP9
Model Number :TSC060G4R0A001S

REV A

MODEL NUMBER DESCRIPTION                        75011255

Precedent Cooling and Gas/Electric

Example Model Number:

Digit 1 – Unit Type
T = DX Cooling
Y = DX Cooling, Gas Heat

Digit 2 – Efficiency
S = Standard Efficiency

Digit 3 – Airflow
C = Convertible

Digits 4,5,6 – Nominal Gross Cooling Capacity (MBh)
033 = 3 Ton (13 SEER)
036 = 3 Ton
043 = 4 Ton (13 SEER)
048 = 4 Ton
060 = 5 Ton
063 = 5 Ton (13 SEER)

Digit 7 – Major Design Sequence
G = Microchannel Type Evaporator and Condenser Coils

Digit 8 – Voltage Selection
3 = 208-230/60/3
4 = 460/60/3
W = 575/60/3

Digit 9 – Unit Controls
E = Electromechanical
R = ReliaTel™ Microprocessor

Digit 10 – Heating Capacity
0 = No Electric Heat
B = 6 kW (3 phase)
E = 12 kW (3 phase)
G = 18 kW (3 phase)
J = 23 W (3 phase)
L = Low Heat
M = Medium Heat
H = High Heat
X = Low Heat, Stainless Steel Heat Exchanger
Y = Medium Heat, Stainless Steel Heat Exchanger
Z = High Heat, Stainless Steel Heat Exchanger

Digit 11 – Minor Design Sequence
A = First Sequence

Digits 12, 13 – Service Sequence
** = Factory Assigned

Digit 14 – Fresh Air Selection
0 = No Fresh Air
A = Manual Outside Air Damper 0-50% (1)
B = Motorized Outside Air Damper 0-50%
C = Economizer, Dry Bulb 0-100% without Barometric Relief (2)
D = Economizer, Dry Bulb 0-100% with Barometric Relief (2)
E = Economizer, Reference Enthalpy 0-100% without Barometric Relief (2,3)
F = Economizer, Reference Enthalpy 0-100% with Barometric Relief (2,3)
G = Economizer, Comparative Enthalpy 0-100% without Barometric Relief (2,3)
H = Economizer, Comparative Enthalpy 0-100% with Barometric Relief (2,3)
K = Low Leak Economizer with Barometric Relief
M = Low Leak Economizer with Reference Enthalpy with Barometric Relief
P = Low Leak Economizer with Comparative Enthalpy with Barometric Relief

Digits 15 – Supply Fan/Drive Type/Motor
0 = Multi Speed Direct Drive Motor
1 = Oversized Motor

Digit 16 – Hinged Service Access/Filters
0 = Standard Panels/Standard Filters
A = Hinged Access Panels/Standard Filters
B = Standard Panels/2″ MERV 8 Filters
C = Hinged Access Panels/2″ MERV8Filters
D = Standard Panels/2″ MERV 13 Filters
E = Hinged Access Panels/2″ MERV 13 Filters

Digit 17 – Condenser Coil Protection (4)
0 = Standard Coil
1 = Standard Coil with Hail Guard
4 = CompleteCoat Condenser Coil
5 = CompleteCoat Condenser Coil with Hail Guard

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals