85e0528 Ice Bath Chiller User Manual
- June 14, 2024
- ICE BATH CHILLER
Table of Contents
85e0528 Ice Bath Chiller User Manual
INSTRUCTION
Smart Life
**Tuya Smart
**
Note: At present, Tuya can only support 2.4G WiFi signal. Therefore, before connecting the phone to the chiller, please confirm that the WiFi used by your phone is in the 2.4G frequency band. It will not be able to connect to the chiller, If it is in the 5G frequency band.
CAUTIONS:
- Do not turn the chiller upside down.
- Do not use without filter element installed
- Make sure there is more 50cm free space around the chiller
- Working Temperature: 1 C~45 C
- Storage Temperature: -20 C~55 C
- Storage Relative Humidity: 20%~85%
(Make sure that there is no water in the internal pipeline of the chiller)
Product Overview
Accessories (SY-08-HC/SY-06-OC)
-
Plastic Wrench
-
Fiter Elements
-
Water Pipes
-
Quick Conectors
-
Rubber Seals
-
Warning Label
-
Warning Label
-
User Manual
SPECIFICATIONS
Model No.| SY-06-HC (cooling heating)
SY-06-OC (cooling)| SY-08-HC (cooling heating)
SY-08-OC (cooling)| SY-10-HC (cooling heating)
SY-10-0C (cooling)| SY-20-HC (cooling heating)
SY-20-OC (cooling )|
---|---|---|---|---|---
Power Supply| AC100-127V AC220-240V AC100-127V
AC220-240V AC100-127V **AC220-240V*
AC100-127V AC220-240V60Hz 50/60Hz
60Hz 50/60Hz 60Hz
50/60Hz 60Hz 50/60Hz|
640W 610W 725W 710W
1170W 1150W 1690W
1950W|
Input Power
Compressor Power| 505W 480W 630W
605W 945W 900W 1450W
1760W|
Cooling Capacity| 1520W 1450W 1790W
1770W 3050W 2900W
3790W 5750W|
Heating Function| Optional|
Cooling Function| Yes|
Refrigerant| R410A|
Water Temp.| 3-42°C / 42-3°C|
Disinfection| Built-in ozone disinfection device|
Circulation Pump| Built-in Self-priming System|
Water Filter| Installed External|
WIFI Remote Control| APP in Android & IOS system|
Transport Wheels| Yes|
Carry Handle| Yes|
Quick Connectors| Yes|
AC Plug| US, UK, EU, AU, SA, TH, IT|
Net Weight| 30kgs| 35kgs| 40kgs| I 45kgs|
Dimension| L43 W33 H48cm| I L47W35H53cm| I L54 W40H55cm|
Certification| CE|
Water Volume&
Cooling Time
(23oC to SoC)
For reference only| 50L51.5H 50L51.9H 50L50.8H
50151.2H
200L52.8H 200L53.1H
2001_52.5H 200L52.0H 100L53.1H 100L53.5H 100L51.7H
100L52.1H
500126.5H 5001.26.9H
5001_24.6H 500L24.1H 200125.2H 200125.6H 200123.9H
200124.2H|
Above data based on testing in closed insulated barrel, 30°C room temperature|
Main Features| Excellent design with low noise| Overloading protection|
Built-in self-priming circulating Pump| With Anti-freeze System|
Water and electricity separating system.| Overheating Protection|
Leakage Protection System for Electricity| Max. Cooling Capacity in Specified
Spaces|
Built-in OZONE disinfection device, and external water filter| Suitable For
Indoor and Outdoor|
WIFI Connection Remote Control by 105 & Android System| Excellent value,
priced to be as affordable as possible|
Easy to Install including hoses with quick connectors| High-definition 7″ LCD
touch panel with adjustable brightness|
Automatic on/off and Constant Temperature System| The detailed fault prompt
function helps you to solve the fault quickly|
Touch Panel Introduction
Status Icons
The corresponding icon will only light up when the current function is turned on.
- Turn on/off
- Press to enter the second screen
- Press 3-5s to lock or unlock
- Press + or – to set the Tempe
- It will be displayed when there is a failure
- Displays the current water flow
Remarks: will only light up for chillers with heating function when
heating.
Touch Panel Introduction
- Adjust the Ozone working time interval: 0 min (close) and max to 5 min
- Adjust the screen brightness: min 10%, max 100%
- Adjust the screen sleep time: 0 min (close), max 5 min
- Adjust the screen lock time: 0 min (close), max 5 min
- Click return button to enter the first interface
- Long press to enter the WiFi function ( connect Tuya or Smart Life)
- Click the help Icon to scan the QR code for technical support
- Temperature unit switching(℃/℉)
- Adjust the button sound: ON/OFF
- Power-on automatic operation ON/OFF
WIFI Description
-
Turn on the chiller.
-
Click the settings key.
-
Press WiFi key for 3-5 seconds until the WiFi blinks.
-
Open the Tuya Smart App on your phone.
-
Select add device
. -
Turn on your phone’s WiFi connection and enter password.
-
Succeeded in adding a link, Enter the App control panel.
Tuya Smart Interface Introductions
- Turn on/off(Turn ON/OFF the chiller)
- Locking (Touch panel lock/unlock)
- Temperature unit switching (C/F)
- Water Flow
- Set TimeSwitch Timer
- Touch screen prompt sound (ON/OFF)
- Power-on automatic operation ON/OFF
- Water Switch1
- Water Switch2
- Adjust the Ozone working time interval: 0 min (close) and max to 5 min
- Temperature adjustment (3-42°C/37-107°F) |
- Current Temperature
Precautions
- Do not block the fan outlet of the room. Otherwise, it will reduce the heating and cooling effect and waste power
- It is forbidden that the equipment is not clean. Regularly check and clean the equipment and filtering device
- It is forbidden to touch the fan during the operation of the equipment to avoid hurting fingers
- Pay attention to whether the rated voltage of the product is consistent with the power supply voltage of the home
- During the operation of the equipment, it is not allowed to touch the switch with hands, let alone